Introduction: As minimally invasive surgery migrates to a single port operative platform, the need for innovative retracting systems is becoming ever apparent. We evaluated an internal, adjustable retraction device for laparoendoscopic surgery, Versa lifter. Methods: Having received IRB approval we conducted a study using a porcine model. We performed 10 cholecystectomies and 10 gastric retraction procedures assessing multiple factors for the retraction device including ease of use, timing & damage to organs. Results: The VERSA LIFTER was very easy to deploy and retrieve with negligible peritoneal damage and overall a very intuitive system to use. Application and retrieval were completed in 3 minutes on average. Conclusion: The VERSA LIFTER is a very effective, efficient and intuitive system for adjustable internal organ retraction for Laparoendoscopic Single site surgery.
AIM:The aim of this study is to demonstrate the efficacy of wireless capsule endoscopy for preoperative identification of bleeding sources and/or small bowel tumours in surgical patients and to evaluate the feasibility of single-port surgery in the treatment of such pathologies. METHOD:Five patients presenting with obscure gastrointestinal bleeding or/and mild small bowel obstruction were investigated to diagnose and localize the bleeding source or tumour using capsule endoscopy imaging, and, if necessary, with other investigative modalities. All patients were operated on using single-port surgery for small bowel exploration, lesion confirmation, small bowel resection and anastomosis. RESULTS:Small bowel pathology was successfully detected by video capsule endoscopy in three of four patients, and was further substantiated by contrast CT, double-balloon endoscopy or enteroclysis. Complete small bowel exploration, intra-operative identification and oncological resection of the involved segment and anastomosis (intracorporeal and extracorporeal) was successfully performed in all five patients using single-port access without any complication, morbidity or mortality. CONCLUSION:This study demonstrates the feasibility and safety of single-port small bowel resection performed after a high-quality preoperative localization of the tumour.
Background and study aim: Endoluminal fullthickness closure of the rectal wall is critical in emerging procedures including endoscopic submucosal dissection and transrectal natural orifice transluminal endoscopic surgery (NOTES). This study aimed to compare manual suture using the transanal endoscopic operation platform (TEO; Karl Storz, Tuttlingen, Germany) with the end-to-end anastomosis hemorrhoid circular stapler (EEA; Covidien, Dublin, Ireland) for closure of the rectal viscerotomy during transrectal NOTES segmental colectomy.Materials and methods: A total of 12 swine underwent transrectal hybrid NOTES partial colectomies. Animals were divided into two groups according to the viscerotomy closure technique: 1) TEO manual suture; 2) EEA circular stapler closure.Results: Mean (+/-SD) viscerotomy closure time was 67.5+/-59.5 minutes and 31.5+/-19.6 minutes for TEO and EEA, respectively. There was one conversion to laparoscopy in the TEO group and a misfiring in the EEA group that required a TEO salvage suture. There was one positive air-leak test in each group. Peritoneal fluid collected at the end of the procedure tested positive for bacterial contamination in all cases. A mild stenosis was present in 4/6 viscerotomies (67 %) in the TEO group and in 1/6 (17 %) in the EEA group on endoscopic control. Inflammatory changes were mild in 3/5 (60 %) and 4/5 (80 %) viscerotomies in the TEO and EEA groups, respectively, whereas severe inflammation was found in 2/5 (TEO) and 1/5 (EEA).Conclusion: Transrectal viscerotomy closure using the EEA circular stapler technique is feasible, easy to perform, and histologically comparable to suture closure through a TEO platform. It may offer an attractive alternative for NOTES segmental colectomies and endoscopic resections.