Variable Resolution X-ray (VRX) CT scanners allow imaging of different sized anatomy at the same proportional level of detail using the same device. For example, the same scanner can be used to image large animals such as dogs, and small ones, like mice, with the same level of anatomical detail. This is achieved by tilting the x-ray detectors so that the projected size of the detecting elements is varied producing reconstructions of smaller fields of view with higher spatial resolution [1], [2]. The resolution of central region of a relatively large field of view can be further enhanced by using two or more detectors with different degrees of tilting [3], [4]. Scanners with such "target" regions are useful for following the evolution of pre-diagnosed lesions or any other situation in which a high resolution is indispensable only for a small region of the patient's anatomy, but a larger field of view is needed to avoid artifacts. A computational model of multi-arm VRX scanners was developed as a fundamental aid in the study and development of these devices [4], [5].This work studies the effect of varying several parameters of the computational model on the quality of the reconstructed image. This will affect the usefulness of the simulator in predicting the quality of the images produced by the scanner being modeled. The parameters studied include the number of X-ray beams per detector cell, the number of energy bins in which the incoming polychromatic beam is divided, and the number of views used in the reconstruction. All these parameters will affect the performance of the simulator both in terms of the time required to perform the computations, and the accuracy of the resulting image. The ideal combination of parameters will allow for faster computation without compromising significantly the resulting quality.
The Variable Resolution X-ray (VRX) technique has been successfully used in a Cone-Beam CT (CBCT) system to increase the spatial resolution of CT images in the transverse plane. This was achieved by tilting the Flat Panel Detector (FPD) to smaller vrx(y) angles in a VRX Cone Beam CT (VRX-CBCT) system. In this paper, the effect on the axial spatial resolution of CT images created by the VRX-CBCT system is examined at different vrx(x) angles, where vrx(x) is the tilting angle of the FPD about its x-axis. An amorphous silicon FPD with a CsI scintillator is coupled with a micro-focus x-ray tube to form a CBCT. The FPD is installed on a rotating frame that allows rotation of up to 90(Omega) about x and y axes of the FPD. There is no rotation about the z-axis (i.e. normal to the imaging surface). Tilting the FPD about its x-axis (i.e. decreasing the vrx(x) angle) reduces both the width of the line-spread function and the sampling distance by a factor of sin vrx(x), thereby increasing the theoretical detector pre-sampling spatial resolution proportionately. This results in thinner CT slices that in turn help increase the axial spatial resolution of the CT images. An in-house phantom is used to measure the MTF of the reconstructed CT images at different vrx(x) angles.
Variable Resolution X-ray (VRX) CT scanners allow imaging of different sized anatomy at the same level of detail using the same device. This is achieved by tilting the x-ray detectors so that the projected size of the detecting elements is varied to produce reconstructions of smaller fields of view with higher spatial resolution. As with regular CT scanners, the images obtained with VRX scanners are affected by different kinds of artifacts of various origins. This work studies some of these artifacts and the impact that the VRX effect has on them. For this, computational models of single-arm single-slice VRX scanners are used to produce images with artifacts commonly found in routine use. These images and artifacts are produced using our VRX CT scanner simulator, which allows us to isolate the system parameters that have a greater effect on the artifacts. A study of the behavior of the artifacts at varying VRX opening angles is presented for scanners implemented using two different detectors. The results show that, although varying the VRX angle will have an effect on the severity of each of the artifacts studied, for some of these artifacts the effect of other factors (such as the distribution of the detector cells and the position of the phantom in the reconstruction grid) is overwhelmingly more significant. This is shown to be the case for streak artifacts produced by thin metallic objects. For some artifacts related to beam hardening, their severity was found to decrease along with the VRX angle. These observations allow us to infer that in regular use the effect of the VRX angle artifacts similar to the ones studied here will not be noticeable as it will be overshadowed by parameters that cannot be easily controlled outside of a computational model.
Variable Resolution X-ray (VRX) CT scanners allow imaging of different sized anatomy at the same level of detail using the same device. This is achieved by tilting the x-ray detectors so that the projected size of the detecting elements is varied producing reconstructions of smaller fields of view with higher spatial resolution.(1) The detector can be divided in two or more separate segments, called arms, which can be placed at different angles, allowing some flexibility for the scanner design. In particular, several arms can be set at different angles creating a target region of considerably higher resolution that can be used to track the evolution of a previously diagnosed condition, while keeping the patient completely inside the field of view (FOV).(2) This work presents newly-developed computer models of single-slice VRX scanners that allow us to study and compare different configurations (that is, various types of detectors arranged in any number of arms arranged in different geometries) in terms of spatial and contrast resolution. In particular, we are interested in comparing the :performance of various geometric configurations that would otherwise be considered equivalent (using the same equipment, imaging FOVs of the same sizes, and having a similar overall scanner size). For this, a VRX simulator was developed, along with mathematical phantoms for spatial resolution and contrast analysis. These tools were used to compare scanner configurations that can be reproduced with materials presently available in our lab.
Acceptance testing and quality control of computed tomography (CT) scanners are of great importance. While most procedures and phantoms for testing other parameters are widely accepted, there is still discussion and uncertainty about low-contrast (LC) performance tests that measure the capability of a CT scanner to discriminate low-contrast objects. This work investigated the development of LC phantoms with available, low-cost polystyrene resin materials and some selected additives. We designed and tested phantoms with several different contrast steps by generating contrast in two different ways, one based on 'physical density difference' and the other on 'atomic number difference'. Physical density difference was achieved by adding a small amount of glycerin to the polystyrene resin, both having similar low atomic-number elements but differing in the density of their atoms. Atomic number difference was achieved by adding a small amount of iodobenzene to the resin, both having approximately the same physical density (less than 1% variation in density) but different atomic (i.e., elemental) composition. Prototypes were evaluated using a Philips Tomoscan LX system and varying beam properties. The behavior and validity of the results are discussed.
High-energy (megavoltage) X-ray imaging is widely used in industry (e.g., aerospace, construction, material sciences) as well as in health care (radiation therapy). One of the fundamental problems with megavoltage imaging is poor contrast and spatial resolution in the detected images due to the dominance of Compton scattering at megavoltage X-ray energies. Therefore, although megavoltage X-rays can be used to image highly attenuating objects that cannot be imaged at kilovoltage energies, the former does not provide the high image quality that is associated with the latter. A high contrast and spatial resolution detector for high-energy X-ray fields called the kinestatic charge detector (KCD) is presented here. The KCD is a tri-electrode ion-chamber based on highly pressurized noble gas. The KCD operates in conjunction with a strip-collimated X-ray beam (for high scatter rejection) to scan across the imaging field. Its thick detector design and unique operating principle provides enhanced charge signal integration for high quality imaging (quantum efficiency ∼50%) despite the unfavorable implications of high-energy X-ray interactions on image quality. The proposed design for a large-field prototype KCD includes a cylindrical pressure chamber along with 576 signal-collecting electrodes capable of resolving at 2mm−1. The collecting electrodes are routed out of the chamber through the flat end-cap, thereby optimizing the mechanical strength of the chamber. This article highlights the simplified design of the chamber using minimal components for simple assembly. In addition, fundamental imaging measurements and estimates of ion recombination that were performed on a proof-of-principle test chamber are presented. The imaging performance of the prototype KCD was found to be an order-of-magnitude greater than commercial phosphor screen based flat-panel systems, demonstrating the potential for high-quality megavoltage imaging for a variety of industrial applications.
The detector presampling modulation transfer function (MTF) of a 576-channel variable resolution x-ray (VRX) computed tomography (CT) scanner was evaluated in this study. The scanner employs a VRX detector, which provides increased spatial resolution by matching the scanner's field of view (FOV) to the size of an object being imaged. Because spatial resolution is the parameter the scanner promises to improve, the evaluation of this resolution is important. The scanner's pre-reconstruction spatial resolution, represented by the detector presampling MTF, was evaluated using both modeling (Monte Carlo simulation) and measurement (the moving slit method). The theoretical results show the increase in the cutoff frequency of the detector presampling MTF from 1.39 to 43.38 cycles/mm as the FOV of the VRX CT scanner decreases from 32 to 1 cm. The experimental results are in reasonable agreement with the theoretical data. Some discrepancies between the measured and the modeled detector presampling MTFs can be explained by the limitations of the model. At small FOVs (1-8 cm), the MTF measurements were limited by the size of the focal spot. The obtained results are important for further development of the VRX CT scanner.
A new Cone-Beam CT (CBCT) system is introduced that uses the concept of Variable Resolution X-ray (VRX) detection, which has previously been demonstrated to significantly increase spatial resolution for small objects. An amorphous silicon Flat Panel Detector (FPD) with a CsI scintillator (PaxScan 2020, Varian, Salt Lake City, UT) is coupled with a micro-focus x-ray tube (35 - 80 kVp, 10 - 250 μA) to form a CBCT. The FPD is installed on a rotating arm that can be adjusted to any angle θ, called the VRX angle, between 90° and 0° with respect to the x-ray direction. A VRX angle of 90° for the detector corresponds to a conventional CBCT whereas a VRX angle of 30° means that the detector is tilted 90° - 30° = 60° from its perpendicular position. Tilting the FPD in this manner reduces both the line-spread function width and the sampling distance by a factor of sin(&thgr;), thereby increasing detector spatial resolution proportionately. An in-house phantom is used to measure the MTF of the reconstructed CT images using different VRX angles. An increase by a factor of 1.67 ± 0.007 is observed in the MTF cutoff frequency at 30° compared to 90° in images acquired at 75 kVp. Expected theoretical value for this case is 2.0. The new Cone-Beam Variable Resolution X-ray (CB-VRX) CT system is expected to significantly improve the images acquired from small objects - such as small animals - while exploiting the opportunities offered by a conventional CBCT.
The Kinestatic Charge Detector (KCD) technique of projection radiography shows promise when used for dual-energy imaging, which may be performed either by taking two separate exposures at different kVp settings (the dual-kVp method) or by taking a single exposure with the KCD segmented into a front and back region (the split-detector method), as the higher energy photons will be preferentially absorbed in the back region.Using computer simulations, we have optimized the dual-energy performance of a segmented KCD using the split-detector method for chest radiography. Theoretical optimization of imaging parameters and determination of contrast resolution were performed by minimizing pixel variances of the basis materials. The expected contrast resolution of the aluminum and plexiglas basis material images was found to be acceptable for purposes of clinical diagnosis. A detector medium of krypton produced better results than xenon at the same density, and the optimal kVp setting was in the range of 120-150 kVp. Preliminary dual-energy images were taken with a small field-of-view split-detector imaging KCD system. The experimentally obtained aluminum and plexiglas basis material pixel variances agree with the theoretical results.
The feasibility of using a Kinestatic Charge Detector (KCD) for dual-energy chest radiography is investigated. A KCD is a gas ionization chamber used with a scanning slot-beam geometry. Dual-energy imaging involves acquisition of two images with different mean photon energies which can then be reconstructed using a suitable algorithm to form images of two basis materials, such as bone and soft-tissue. With a KCD, dual-energy imaging may be performed either by taking two separate exposures at different kVp settings ( the dual-kVp method) or by taking a single exposure with the KCD segmented into a front and back region ( the split-detector method), as the higher energy photons will be preferentially absorbed in the back region.We have investigated the feasibility of a dual-energy KCD using computer simulations for both dual-kVp and split-detector systems. The theoretically determined contrast resolutions for aluminum and plexiglas were found to be sufficient for clinical diagnosis; however, electronic noise was found to be a major limiting factor. The dual-kVp method was found to yield significant improvements over the split-detector method at high material thicknesses.
Efforts to improve the spatial resolution of CT scanners have focused mainly on reducing the source and detector element sizes, ignoring losses from the size of the secondary-ionization charge "clouds" created by the detected x-ray photons, i.e., the "physics limit." This paper focuses on implementing a technique called "projective compression." which allows further reduction in effective cell size while overcoming the physics limit as well. Projective compression signifies detector geometries in which the apparent cell size is smaller than the physical cell size, allowing large resolution boosts. A realization of this technique has been developed with a dual-arm "variable-resolution x-ray" (VRX) detector. Accurate values of the geometrical parameters are needed to convert VRX outputs to formats ready for optimal image reconstruction by standard CT techniques. The required calibrating data are obtained by scanning a rotating pin and fitting a theoretical parametric curve (using a multi-parameter minimization algorithm) to the resulting pin sinogram. Excellent fits are obtained for both detector-arm sections with an average (maximum) fit deviation of ~0.05 (0.1) detector cell width. Fit convergence and sensitivity to starting conditions are considered. Pre- and post-optimization reconstructions of the alignment pin and a biological subject reconstruction after calibration are shown.
This article discusses the design and analysis of a portal imaging system based on a thick transparent scintillator. A theoretical analysis using Monte Carlo simulation was performed to calculate the x-ray quantum detection efficiency (QDE), signal to noise ratio (SNR) and the zero frequency detective quantum efficiency [DQE(0)] of the system. A prototype electronic portal imaging device (EPID) was built, using a 12.7 mm thick, 20.32 cm diameter, Csl(Tl) scintillator, coupled to a liquid nitrogen cooled CCD TV camera. The system geometry of the prototype EPID was optimized to achieve high spatial resolution. The experimental evaluation of the prototype EPID involved the determination of contrast resolution, depth of focus, light scatter and mirror glare. Images of humanoid and contrast detail phantoms were acquired using the prototype EPID and were compared with those obtained using conventional and high contrast portal film and a commercial EPID. A theoretical analysis was also carried out for a proposed full field of view system using a large area, thinned CCD camera and a 12.7 mm thick CsI(TI) crystal. Results indicate that this proposed design could achieve DQE(0) levels up to 11%, due to its order of magnitude higher QDE compared to phosphor screen-metal plate based EPID designs, as well as significantly higher light collection compared to conventional TV camera based systems.
An adaptive median filter algorithm to remove impulse noise in x-ray images and speckle in ultrasound images is presented. The ordinary median filter tends to distort or lose fine details in an image. Also, a significant amount of the original information in the image is altered. The proposed algorithm considers the local variability over the entire image to ensure that the fine details are preserved and more than 90 percent of the original information is retained. The robustness of the algorithm is demonstrated by applying it to images from different modalities like diagnostic x-ray, CT, portal imaging and ultrasound.