The next generation of hard X-ray space telescopes for astrophysics and solar physics requires the development of focal planes with high detection efficiency above 10 keV and enhanced spectroscopic imaging performance. We designed and produced MC2-1K, the first prototype of a new family of fine pitch hybrid detectors. It consists of a 32 x 32 pixel CdTe semiconductor detector point-to-point connected to the spectroscopic channels of a full-custom ASIC. The ASIC named D2R2 was produced in 2019 in the XFAB 0.18 mu m technology and has the same 250 mu m pixel pitch as the detector. We demonstrated a median equivalent charge noise of 54 e-RMS, equivalent to an energy resolution of 654 eV at 31 keV for a CdTe detector. We developed an acquisition system where the signals of D2R2's 32 rows are encoded in parallel by a 32-channel ADC ASIC, OWB-1. The custom daughter board with the hybrid detector is placed in a thermally controlled vacuum chamber for a moderate cooling. This paper will present the characterization tests of the ASIC, the dedicated test set-up and the first spectroscopic measurements of the MC2-1K hybrid detector.
In the framework of a national funded program for nuclear safety, a first prototype of portable gamma camera was built and tested. It integrates a Caliste-HD CdTe-hybrid detector designed for space X-ray astronomy coupled with a new system-on-chip based acquisition system (FPGA and ARM microprocessor) and thermo-electrical coolers for a use at room temperature. The complete gamma part of the camera fits in a volume of 15×15×40cm3 for a mass lower than 1 kg and a power consumption lower than 10 W. Localization and spectro-identification of radionuclides in a contaminated scene were demonstrated during several test campaigns. A new generation of system is under development taking into account feedback experience from in-situ measurements and integrating a new generation of sensor cost-optimized by industrial applications called Caliste-O. Caliste-O holds a 16×16 pixel detector of 14×14mm2 and 2 mm thick with 8 full-custom front-end IDeF-X HD ASICs. Two prototypes were fabricated and tested. The paper will present the results of in-situ measurements with the first gamma camera, the spectroscopic performance of Caliste-O and the design of the second generation of gamma camera which aims for real time imaging and spectro-identification.
Caliste-SO are CdTe hybrid detectors that will be used as spectrometer units in the Spectrometer Telescope for Imaging X-rays (STIX) on-board the Solar Orbiter space mission. Each unit is placed below one collimator of this Fourier telescope to measure one visibility of the image in the 4-150 keV energy range, with a spectral resolution of 1 keV FWHM at 6 keV. The paper presents the scientific requirements, the design, the fabrication and the tests of the Caliste- SO devices before mounting them onto printed circuits boards. Spectral response was characterized on the 98 spacegrade units for various operating parameters. The devices will equip the different instrument validation models, including 32 units for the final instrument flight model to be launched in 2018.
Caliste-SO is a CdTe hybrid detector designed to be used as a spectrometer for a hard X-ray Fourier telescope. The imaging technique was implemented in the Yohkoh satellite in 1991 and the RHESSI satellite in 2002 to achieve arc-second angular resolution images of solar flares with spectroscopic capabilities. The next generation of such instruments will be the Spectrometer Telescope Imaging X-rays (STIX) on-board the Solar Orbiter mission adopted by the European Space Agency in 2011 for launch in 2017. The design and performance of Caliste-SO allows both high spectral resolution and high count rate measurements from 4 to 150keV with limited demands on spacecraft resources such as mass, power and volume (critical for interplanetary missions). The paper reports on the flight production of the Caliste-SO devices for STIX, describing the test facilities built-up in Switzerland and France. It illustrates some results obtained with the first production samples that will be mounted in the STIX engineering model.
Caliste project aims at hybridizing 1cm2 CdTe or CdZnTe pixel detectors with low-noise full custom front-end electronics, in a single component standing in a 1×1×2cm3 volume. Caliste device is 4-side buttable and can be used as elementary detection unit of a large mosaic to form a hard X-ray focal plane of any size and shape. Caliste is especially designed to match astronomical space mission requirements and its design takes into account environmental constraints, radiation environment in particular. This new imaging spectrometer for hard X-rays detection offers high spectral and spatial resolution together with accurate time-tagging capability and low dead time. Caliste concept relies on a 3D hybridization technology that consists in stacking full custom ASICs perpendicular to the detection surface into a single component. This technique simultaneously permits to realize a buttable imager and to enhance performance and uniformity response. Our last prototype is called Caliste 256 and integrates 16×16 pixels array, 580μm pitch and 256 corresponding independent spectroscopy channels. This paper presents Caliste 256 design and properties. We emphasize spectral performance and demonstrate spectral resolution capabilities better than 1keV FWHM at 60keV.
Caliste HD is the last member of the Caliste family of Cd(Zn)Te micro-cameras for space applications. This hybrid component is made of the assembly of one 16 × 16 pixel Cd(Zn)Te detector and eight analog front-end ASIC named IDeF-X HD equipped with 32 spectroscopic channels. The pixels are 625 μm pitch and are surrounded by a 20 μm wide guard ring. The new generation of ASIC has the advantage of having a power consumption 4 times lower as the previous version (0.2 W for the full device) and offers the possibility to extend the dynamic range from 250 keV to 1 MeV. The technology is fully compliant with operation in space (tolerant to radiation, thermal and mechanical constraints). This paper presents the preliminary spectroscopic results obtained with the samples produced so far. At -16°C the sum spectrum built with all single events of the 1 mm-thick Al Schottky detector show an energy resolution of 0.82 keV FWHM at 14 keV and 0.92 keV FWHM at 60 keV. A good uniformity in gain and in noise is measured over the 256 pixels; the low level-threshold is lower than 2 keV for all pixels.
In the frame of the Simbol-X mission of hard X-ray astrophysics, a prototype of micro-camera with 64 pixels called Caliste 64 has been designed and several samples have been tested. The device integrates ultra-low-noise IDeF-X V1.1 ASICs from CEA and a 1cm2 Al Schottky CdTe detector from Acrorad because of its high uniformity and spectroscopic performance. The process of hybridization, mastered by the 3D Plus company, respects space applications standards. The camera is a spectro-imager with time-tagging capability. Each photon interacting in the semiconductor is tagged with a time, a position and an energy. Time resolution is better than 100ns rms for energy deposits greater than 20keV, taking into account electronic noise and technological dispersal of the front-end electronics. The spectrum summed across the 64 pixels results in an energy resolution of 664eV fwhm at 13.94keV and 842eV fwhm at 59.54keV, when the detector is cooled down to −10°C and biased at −500V.
In the frame of the hard X-ray Simbol-X observatory, a joint CNES-ASI space mission to be flown in 2014, a prototype of miniature Cd(Zn)Te camera equipped with 64 pixels has been designed. The device, called Caliste 64, is a spectro-imager with high resolution event timetagging capability. Caliste 64 integrates a Cd(Zn)Te semiconductor detector with segmented electrode and its front-end electronics made of 64 independent analog readout channels. This 1 × 1 × 2 cm3 camera, able to detect photons in the range from 2 keV up to 250 keV, is an elementary detection unit juxtaposable on its four sides. Consequently, large detector array can be made assembling a mosaic of Caliste 64 units. Electronics readout module is achieved by stacking four IDeF-X V1.1 ASICs, perpendicular to the detection plane. We achieved good noise performances, with a mean Equivalent Noise Charge of ~65 electrons rms over the 64 channels. For the first prototypes, we chose Pt//CdTe//Al/Ti/Au Schottky detectors because of their very low dark current and excellent spectroscopic performances. Recently a Caliste 64 prototype has been also equipped with a 2 mm thick Au//CdZnTe//Au detector. This paper presents the performances of these four prototypes and demonstrates spectral performances better than 1 keV fwhm at 59.54 keV when the samples are moderately cooled down to -10°C.
In the frame of the hard X-ray simbol-X observatory, a joint CNES-ASI space mission to be flown in 2013, a prototype of miniature camera equipped with 64 pixels has been designed. The device, called CALISTE 64, is a spectro- imager with high resolution event time-tagging capability. CALISTE 64 integrates a CdTe semiconductor detector with segmented electrode and its front-end electronics made of 64 independent analogue readout channels. This 10times10times18 mm3 camera, able to detect photons in the range from 2 keV up to 250 keV, is an elementary detection unit juxtaposable on its four sides. Consequently, large detector array can be made assembling a mosaic of CALISTE 64 units. Electronics readout module is achieved by stacking four IDeF-X V1.1 ASICs in a 3D-module, perpendicular to the detection plane. We achieved good noise performances, with an equivalent noise charge better than 60 electrons rms in average. We choose CdTe detectors equipped with aluminum Schottky barrier contacts because of their very low dark current and excellent spectroscopic performances. The first integrated CALISTE 64 camera was realized and tested. The device operates properly and all the 64 pixels show good spectra. When the crystal is cooled down to -10degC and biased at -400 V, the resulting sum spectrum shows a spectral resolution of 697 eV FWHM at 13.9 keV and 808 eV FWHM at 59.54 keV. This paper presents the CALISTE 64 design and preliminary performance test results.