Ongoing legalization of cannabis for recreational use contributes to increasing numbers not only of incidents of driving under the influence, but within all forensic fields. In addition, newly emerging cannabinoids such as hexahydrocannabinol (HHC) and the increasing use of cannabidiol (CBD) products have to be addressed. The aims of this study were first to extend laboratory analysis capacity for the "established" cannabinoid triangle 9-tetrahydrocannabinol (THC) and its metabolites 11-OH-THC and THC-COOH in human plasma/blood, and second to develop analytical procedures concerning HHC and CBD. An LC-MS/MS method based on the available (low-end) instrumentation was used. Samples (250 mu l) were prepared by protein precipitation and solid-phase extraction. Chromatographic separation was achieved on a reversed-phase C18 column within 15 min. Detection was performed on a 3200 QTRAP instrument (Sciex) in positive multiple reaction monitoring (MRM) mode. Matrix-matched six-point calibrations were generated applying deuterated internal standards for all analytes except HHC. The method was fully validated according to GTFCh guidelines.Linear ranges were 0.5-25 mu g/l for THC, 11-OH-THC, HHC and CBD, and 2.0-100 mu g/l for THC-COOH, respectively. Limits of detection and limits of quantification were 0.5 and 1.0 mu g/l (THC, 11-OH-THC, HHC, CBD), and 2.0 and 4.0 mu g/l (THC-COOH). Applicability of plasma calibrations to blood samples was demonstrated. Acceptance criteria for intra- and inter-day accuracy, precision, extraction efficiency, and matrix effects were met. No interfering signals were detected for 80 exogenous compounds. The presented method is sensitive, specific, easy to handle, and does not require high-end equipment. Since its implementation and accreditation according to ISO 17025, the method has proven to be fit for purpose not only in driving under the influence of drug cases but also within post-mortem samples. Furthermore, the design of the method allows for an uncomplicated extension to further cannabinoids if required.
Hexahydrocannabinol (HHC), 6,6,9-trimethyl-3-pentyl-6a,7,8,9,10,10a-hexahydrobenzo[c]chromen-1-ol, is a semi-synthetic cannabinoid that has presented challenges to analytical laboratories due to its emergence and spread in the drug market. The lack of information on human pharmacokinetics hinders the development and application of presumptive and confirmatory tests for reliably detecting HHC consumption. To address this knowledge gap, we report the analytical results obtained from systematic forensic toxicological analysis of body-fluid samples collected from three individuals suspected of drug-impaired driving after HHC consumption. Urine and plasma samples were analyzed using non-targeted liquid chromatography-high-resolution tandem mass spectrometry. The results provided evidence that HHC undergoes biotransformation reactions similar to other well-characterized cannabinoids, such as triangle 9-tetrahydrocannabinol or cannabidiol. Notably, HHC itself was only detectable in plasma samples, not in urine samples. The observed Phase I reactions involved oxidation of C11 and the pentyl side chain, leading to corresponding hydroxylated and carboxylic acid species. Additionally, extensive glucuronidation of HHC and its Phase I metabolites was evident.
Germline de novo missense variants of the CACNA1D gene, encoding the pore-forming α1 subunit of Cav1.3 L-type Ca2+ channels (LTCCs), have been found in patients with neurodevelopmental and endocrine dysfunction, but their disease-causing potential is unproven. These variants alter channel gating, enabling enhanced Cav1.3 activity, suggesting Cav1.3 inhibition as a potential therapeutic option. Here we provide proof of the disease-causing nature of such gating-modifying CACNA1D variants using mice (Cav1.3AG) containing the A749G variant reported de novo in a patient with autism spectrum disorder (ASD) and intellectual impairment. In heterozygous mutants, native LTCC currents in adrenal chromaffin cells exhibited gating changes as predicted from heterologous expression. The A749G mutation induced aberrant excitability of dorsomedial striatum–projecting substantia nigra dopamine neurons and medium spiny neurons in the dorsal striatum. The phenotype observed in heterozygous mutants reproduced many of the abnormalities described within the human disease spectrum, including developmental delay, social deficit, and pronounced hyperactivity without major changes in gross neuroanatomy. Despite an approximately 7-fold higher sensitivity of A749G-containing channels to the LTCC inhibitor isradipine, oral pretreatment over 2 days did not rescue the hyperlocomotion. Cav1.3AG mice confirm the pathogenicity of the A749G variant and point toward a pathogenetic role of altered signaling in the dopamine midbrain system.
Proton-transfer reaction mass spectrometry (PTR-MS) is a versatile tool for the mass spectrometric analysis of organic molecules in gaseous samples. Due to its operation principle, PTR-MS is a soft ionization technique generating spectral data typically rich in protonated molecule information. Most of the currently reported PTR-MS applications are designed to determine volatile compounds. Herein, we present a redesigned instrumental setup termed “high-temperature (HT)-PTR-MS” with improved capabilities for the analysis of low-volatile compounds. The developed HT-PTR-MS prototype was successfully hyphenated with gas chromatography (GC) to enable qualitative and quantitative analysis of licit and illicit drugs in human blood/plasma samples. Different kinds of spiked and authentic samples were used to evaluate the performance of the GC-HT-PTR-MS in forensic drug testing. Benchmarking against GC-MS with electron ionization demonstrated the improved detection capabilities of GC-HT-PTR-MS in screening applications. On average, one order of magnitude lower limits of detection/identification were reached. Clearly, GC-HT-PTR-MS has the vast potential to complement or even replace established mass spectrometric techniques in forensic drug analysis.
Buprenorphine is a semisynthetic opioid that is often used in opiate maintenance therapy. For this purpose, regular toxicological analyses of urine samples are mandatory. For fast analytical results, analyses are commonly performed by immunoassay, for example, Thermo Scientific™ CEDIA® Buprenorphine or Buprenorphine II assay. One drawback of immunoassay-based methods is the possible cross-reaction with other substances. Several drugs have already been checked for cross-reactivity to CEDIA® Buprenorphine II immunoassay. In contrast, cross-reactivities have not been checked for any food additives. In the present study, a cross-reaction of CEDIA® Buprenorphine II assay to steviol glucuronide was investigated. Steviol glucuronide is a phase II metabolite of the sugar substitute stevia. For our study, 32 urine samples of patients in rehabilitation centers were collected. These samples were tested positive with the CEDIA® Buprenorphine II immunoassay. These findings were suspicious, because it was highly unlikely that the patients in those institutions had access to buprenorphine. The absence or presence of buprenorphine in urine samples was evaluated by a validated gas chromatography-mass spectrometry method. In order to determine the concentration of steviol glucuronide in urine samples, a liquid chromatography-tandem mass spectrometry method has been developed and fully validated according to the respective guidelines of the German Society of Toxicological and Forensic Chemistry. The cross-reactivity of steviol glucuronide in the CEDIA® Buprenorphine II immunoassay was observed at concentrations above 15,000 µg/L. These findings demonstrate that food additives should also be considered as compounds that may reduce the selectivity of immunoassays and emphasize the importance of confirming implausible results by selective analytical methods.
Background Androgen receptor targeted therapies have emerged as an effective tool to manage advanced prostate cancer (PCa). Nevertheless, frequent occurrence of therapy resistance represents a major challenge in the clinical management of patients, also because the molecular mechanisms behind therapy resistance are not yet fully understood. In the present study, we therefore aimed to identify novel targets to intervene with therapy resistance using gene expression analysis of PCa co-culture spheroids where PCa cells are grown in the presence of cancer-associated fibroblasts (CAFs) and which have been previously shown to be a reliable model for antiandrogen resistance. Methods Gene expression changes of co-culture spheroids (LNCaP and DuCaP seeded together with CAFs) were identified by Illumina microarray profiling. Real-time PCR, Western blotting, immunohistochemistry and cell viability assays in 2D and 3D culture were performed to validate the expression of selected targets in vitro and in vivo. Cytokine profiling was conducted to analyze CAF-conditioned medium. Results Gene expression analysis of co-culture spheroids revealed that CAFs induced a significant upregulation of cholesterol and steroid biosynthesis pathways in PCa cells. Cytokine profiling revealed high amounts of pro-inflammatory, pro-migratory and pro-angiogenic factors in the CAF supernatant. In particular, two genes, 3-hydroxy-3-methylglutaryl-Coenzyme A synthase 2 (HMGCS2) and aldo-keto reductase family 1 member C3 (AKR1C3), were significantly upregulated in PCa cells upon co-culture with CAFs. Both enzymes were also significantly increased in human PCa compared to benign tissue with AKR1C3 expression even being associated with Gleason score and metastatic status. Inhibiting HMGCS2 and AKR1C3 resulted in significant growth retardation of co-culture spheroids as well as of various castration and enzalutamide resistant cell lines in 2D and 3D culture, underscoring their putative role in PCa. Importantly, dual targeting of cholesterol and steroid biosynthesis with simvastatin, a commonly prescribed cholesterol synthesis inhibitor, and an inhibitor against AKR1C3 had the strongest growth inhibitory effect. Conclusions From our results we conclude that CAFs induce an upregulation of cholesterol and steroid biosynthesis in PCa cells, driving them into AR targeted therapy resistance. Blocking both pathways with simvastatin and an AKR1C3 inhibitor may therefore be a promising approach to overcome resistances to AR targeted therapies in PCa.
Buprenorphine is a commonly used opioid in pain therapy as well as in opiate maintenance therapy. Immunoassays are quick and cost-effective methods for the necessary toxicological urine analysis of maintenance therapy patients. In this study a novel enzymatic immunoassay, the Thermo Fisher Scientific CEDIA Buprenorphine II assay (Bup2) was evaluated for the detection of buprenorphine, norbuprenorphine and their conjugated metabolites in human urine samples. The Bup2 assay has a cut-off of 10 ng/mL with ±25% controls, whereas the existing CEDIA Buprenorphine assay (Bup1) has a cut-off of 5 ng/mL and ±40% controls. Both assays were analyzed on a Thermo Scientific Indiko Plus benchtop analyzer. Seven-day precision studies of Bup2 assay demonstrated excellent precision of 7.2-10.6%. No crossover between control samples and the cut-off level were observed. Urine samples of 120 patients undergoing opiate maintenance therapy were collected. Immunoassay results of Bup1 and Bup2 were confirmed by gas chromatography mass spectrometry (GC/MS) for buprenorphine and norbuprenorphine as well as for their glucuronides. Comparison showed a specificity of 0.99 between the Bup2 assay and GC/MS, whereas the Bup1 assay had a specificity 0.70 due to 21 false positive samples. The reason is a known cross-reactivity of the Bup1 assay to opiate compounds. The Bup2 assay revealed one false positive result close to the cut-off value; no specific candidate possibly causing a cross-reaction was detected by GC/MS and liquid chromatography tandem mass-spectrometry (LC/MS/MS) methods. The data presented demonstrate an excellent correlation of the Bup2 assay to GC/MS, showing improved specificity and sensitivity when compared to the Bup1 assay. Thus, the Bup2 assay is highly suitable for urine testing, even for opiate maintenance patients receiving high doses of morphine.
Tryptophan (TRP) catabolism via the kynurenine pathway is considered to represent a major link between inflammation and various diseases, including neurodegenerative disorders, depression, schizophrenia, multiple sclerosis, cardiovascular disease, and cancer. The kynurenine pathway and levels of TRP and its metabolites kynurenine (KYN), kynurenic acid (KYNA) and quinolinic acid (QUIN) are well regulated under physiological conditions but may be altered as part of the activated immune response. A simple, sensitive, and specific liquid chromatography‐time of flight mass spectrometry method was developed for determining levels of the four compounds in human plasma samples. The workflow involves protein precipitation with acetonitrile, chromatographic separation on a Phenomenex Luna NH2 column by applying a linear 6 min gradient of 50–5% acetonitrile in aqueous ammonium acetate solution (5 mM, pH 9.5), and mass spectrometric detection with high‐resolution tandem mass spectrometry. Charcoal‐treated plasma served as surrogate matrix for external standard calibration. Stable‐isotope‐labeled analogues were used as internal standards. The calibration ranges were 0.5–50 μg/ml for TRP, 20–1000 ng/mL for KYN und QUIN, and 1–50 ng/mL for KYNA. Validation proved fitness of the developed workflow for the intended purpose. The established method was applied to the quantification of the four targets in 100 authentic plasma samples.
Systematic toxicological analysis (STA) is an important step in medicolegal investigations of death, poisoning, and drug use. The primary goal is the detection and confirmation of potentially toxic compounds in evidence. This article describes a workflow using nontargeted liquid chromatography-tandem mass spectrometry (LC-MS/ MS) for reliable compound identification. Tandem mass spectrometry was performed on a low-resolution quadrupole-quadrupole-linear ion trap instrument. Acquired spectra were submitted to an automated library search, and positive matches were verified by expert reviewing. After validation, the nontargeted LC-MS/MS technique was integrated in the STA service provided by our laboratory.
Ca2+-influx through L-type Ca2+-channels (LTCCs) is associated with activity-related stressful oscillations of Ca2+ levels within dopaminergic (DA) neurons in the substantia nigra (SN), which may contribute to their selective degeneration in Parkinson's disease (PD). LTCC blockers were neuroprotective in mouse neurotoxin models of PD, and isradipine is currently undergoing testing in a phase III clinical trial in early PD. We report no evidence for neuroprotection by in vivo pretreatment with therapeutically relevant isradipine plasma levels, or Cav1.3 LTCC deficiency in 6-OHDA-treated male mice. To explain this finding, we investigated the pharmacological properties of human LTCCs during SN DA-like and arterial smooth muscle (aSM)-like activity patterns using whole-cell patch-clamp recordings in HEK293 cells (Cav1.2 α1-subunit, long and short Cav1.3 α1-subunit splice variants; β3/α2δ1). During SN DA-like pacemaking, only Cav1.3 variants conducted Ca2+ current (ICa) at subthreshold potentials between action potentials. SN DA-like burst activity increased integrated ICa during (Cav1.2 plus Cav1.3) and after (Cav1.3) the burst. Isradipine inhibition was splice variant and isoform dependent, with a 5- to 11-fold lower sensitivity to Cav1.3 variants during SN DA-like pacemaking compared with Cav1.2 during aSM-like activity. Supratherapeutic isradipine concentrations reduced the pacemaker precision of adult mouse SN DA neurons but did not affect their somatic Ca2+ oscillations. Our data predict that Cav1.2 and Cav1.3 splice variants contribute differentially to Ca2+ load in SN DA neurons, with prominent Cav1.3-mediated ICa between action potentials and after bursts. The failure of therapeutically relevant isradipine levels to protect SN DA neurons can be explained by weaker state-dependent inhibition of SN DA LTCCs compared with aSM Cav1.2.SIGNIFICANCE STATEMENT The high vulnerability of dopamine (DA) neurons in the substantia nigra (SN) to neurodegenerative stressors causes Parkinson's disease (PD). Ca2+ influx through voltage-gated L-type Ca2+ channels (LTCCs), in particular Cav1.3, appears to contribute to this vulnerability, and the LTCC inhibitor isradipine is currently being tested as a neuroprotective agent for PD in a phase III clinical trial. However, in our study isradipine plasma concentrations approved for therapy were not neuroprotective in a PD mouse model. We provide an explanation for this observation by demonstrating that during SN DA-like neuronal activity LTCCs are less sensitive to isradipine than Cav1.2 LTCCs in resistance blood vessels (mediating dose-limiting vasodilating effects) and even at supratherapeutic concentrations isradipine fails to reduce somatic Ca2+ oscillations of SN DA neurons.
We present here the self-assembly of a green-emitting metallo-supramolecular rhomboid into a rigid, highly-ordered 3D multi-chromophoric network through the mediation of a tetra-anionic violet-blue molecular emitter. Control was obtained on the spatial topology, the electronic energy landscape and the fluorescence polarization of the interacting dipoles.
The health benefit through the control of lipid levels in hyperlipidaemic individuals is evident from a large number of studies. The pharmacological options to achieve this goal shall be as specific and personalized as the reasons for and co-factors of hyperlipidaemia. It was the goal of this study to reveal the impact of leoligin on cholesterol levels and to define its mechanism of action. Oral application of leoligin in ApoE-/- mice led to significantly reduced total serum cholesterol levels and a reduction in postprandial blood glucose peak levels. In the absence of biochemical signs of toxicity, leoligin treatment resulted in reduced weight gain in mice. The effects of leoligin on serum cholesterol levels may be due to a direct inhibition of 3-hydroxy-3-methyl-glutaryl-CoA reductase (HMGCR) by a unique, non-statin-like binding mode. Postprandial serum glucose peaks may be reduced by a mild peroxisome proliferator-activated receptor-gamma (PPAR-γ) agonistic activity of leoligin. No effect on atherosclerotic plaque size was observed. As a non-toxic, cholesterol-, peak glucose-, and weight gain-lowering compound, leoligin continues to fulfil characteristics of a potential agent for the treatment of cardiovascular disease (CVD). The counterregulatory overexpression of hepatic HMGCR in leoligin treated animals possibly explains the missing permanent anti-atherosclerotic effect.
Forensic toxicology and environmental water analysis share the common interest and responsibility in ensuring comprehensive and reliable confirmation of drugs and pharmaceutical compounds in samples analyzed. Dealing with similar analytes, detection and identification techniques should be exchangeable between scientific disciplines. Herein, we demonstrate the successful adaption of a forensic toxicological screening workflow employing nontargeted LC/MS/MS under data-dependent acquisition control and subsequent database search to water analysis. The main modification involved processing of an increased sample volume with SPE (500 mL vs. 1-10 mL) to reach LODs in the low ng/L range. Tandem mass spectra acquired with a qTOF instrument were submitted to database search. The targeted data mining strategy was found to be sensitive and specific; automated search produced hardly any false results. To demonstrate the applicability of the adapted workflow to complex samples, 14 wastewater effluent samples collected on seven consecutive days at the local wastewater-treatment plant were analyzed. Of the 88,970 fragment ion mass spectra produced, 8.8% of spectra were successfully assigned to one of the 1040 reference compounds included in the database, and this enabled the identification of 51 compounds representing important illegal drugs, members of various pharmaceutical compound classes, and metabolites thereof.
Redox reactions are integral parts of many cellular processes. They are therefore extensively studied in vitro and in vivo. Electrochemistry (EC) represents a purely instrumental approach to characterize direct and indirect effects of redox reactions on bioorganic molecules, such as peptides, proteins, and endogenous and exogenous small molecules as well as nucleic acids. In addition to direct infusion electrospray ionization (ESI)-mass spectrometry (MS), hyphenated techniques such as liquid chromatography-mass spectrometry (LC-MS) are often applied for comprehensive characterization of reaction mixtures generated by EC experiments. EC-LC-MS represents a fast, automatable, and "green" approach that can be used in a variety of "omics" disciplines. This review highlights important trends and recent developments.
We herein present the coordination-driven supramolecular synthesis and photophysics of a [4+4] and a [2+2] assembly, built up by alternately collocated donor-acceptor chromophoric building blocks based, respectively, on the boron dipyrromethane (Bodipy) and perylene bisimide dye (PBI). In these multichromophoric scaffolds, the intensely absorbing/emitting dipoles of the Bodipy subunit are, by construction, cyclically arranged at the corners and aligned perpendicular to the plane formed by the closed polygonal chain comprising the PBI units. Steady-state and fs time-resolved spectroscopy reveal the presence of efficient energy transfer from the vertices (Bodipys) to the edges (PBIs) of the polygons. Fast excitation energy hopping - leading to a rapid excited state equilibrium among the low energy perylene-bisimide chromophores - is revealed by fluorescence anisotropy decays. The dynamics of electronic excitation energy hopping between the PBI subunits was approximated on the basis of a theoretical model within the framework of Förster energy transfer theory. All energy-transfer processes are quantitatively describable with Förster theory. The influence of structural deformations and orientational fluctuations of the dipoles in certain kinetic schemes is discussed.
Electrochemistry (EC) is a mature scientific discipline aimed to study the movement of electrons in an oxidation-reduction reaction. EC covers techniques that use a measurement of potential, charge, or current to determine the concentration or the chemical reactivity of analytes. The electrical signal is directly converted into chemical information. For in-depth characterization of complex electrochemical reactions involving the formation of diverse intermediates, products and byproducts, EC is usually combined with other analytical techniques, and particularly the hyphenation of EC with mass spectrometry (MS) has found broad applicability. The analysis of gases and volatile intermediates and products formed at electrode surfaces is enabled by differential electrochemical mass spectrometry (DEMS). In DEMS an electrochemical cell is sampled with a membrane interface for electron ionization (EI)-MS. The chemical space amenable to EC/MS (i.e., bioorganic molecules including proteins, peptides, nucleic acids, and drugs) was significantly increased by employing electrospray ionization (ESI)-MS. In the simplest setup, the EC of the ESI process is used to analytical advantage. A limitation of this approach is, however, its inability to precisely control the electrochemical potential at the emitter electrode. Thus, particularly for studying mechanistic aspects of electrochemical processes, the hyphenation of discrete electrochemical cells with ESI-MS was found to be more appropriate. The analytical power of EC/ESI-MS can further be increased by integrating liquid chromatography (LC) as an additional dimension of separation. Chromatographic separation was found to be particularly useful to reduce the complexity of the sample submitted either to the EC cell or to ESI-MS. Thus, both EC/LC/ESI-MS and LC/EC/ESI-MS are common.
The global metabolic profile of Laurencia crude red algal extracts was addressed by applying high-throughput analytical techniques, namely UHPLC–PDA–HRMS and 2D HSQC NMR. An integrated platform including software tools and databases, such as Xcalibur, ToxID, ACD/Labs and MarinLit, has been developed to mine the complex analytical data towards the accelerated identification of known metabolites and the detection of new natural products at the early stages of phytochemical analysis. In parallel, a searchable 'in-house' Laurencia-focused NMR database incorporating chemical structures, NMR spectroscopic data and reported biological activities has been generated. The screening strategy has been developed as a tool to prioritize the crude extracts to be further subjected to phytochemical analysis by tracing the presence of new natural products among the pool of known compounds. The successful application of this integrated methodology in the crude extract of Laurencia chondrioides led to the rapid detection of two new C15 bromoallene acetogenins (1 and 2), which were subsequently isolated and characterized.
Liquid chromatography-tandem mass spectrometry (LC-MS/MS) has become an indispensable analytical technique in clinical and forensic toxicology for detection and identification of potentially toxic or harmful compounds. Particularly, non-target LC-MS/MS assays enable extensive and universal screening requested in systematic toxicological analysis. An integral part of the identification process is the generation of information-rich product ion spectra which can be searched against libraries of reference mass spectra. Usually, 'data-dependent acquisition' (DDA) strategies are applied for automated data acquisition. In this study, the 'data-independent acquisition' (DIA) method 'Sequential Windowed Acquisition of All Theoretical Fragment Ion Mass Spectra' (SWATH) was combined with LC-MS/MS on a quadrupole-quadrupole-time-of-flight (QqTOF) instrument for acquiring informative high-resolution tandem mass spectra. SWATH performs data-independent fragmentation of all precursor ions entering the mass spectrometer in 21m/z isolation windows. The whole m/z range of interest is covered by continuous stepping of the isolation window. This allows numerous repeat analyses of each window during the elution of a single chromatographic peak and results in a complete fragment ion map of the sample. Compounds and samples typically encountered in forensic casework were used to assess performance characteristics of LC-MS/MS with SWATH. Our experiments clearly revealed that SWATH is a sensitive and specific identification technique. SWATH is capable of identifying more compounds at lower concentration levels than DDA does. The dynamic range of SWATH was estimated to be three orders of magnitude. Furthermore, the >600,000 SWATH spectra matched led to only 408 incorrect calls (false positive rate = 0.06 %). Deconvolution of generated ion maps was found to be essential for unravelling the full identification power of LC-MS/MS with SWATH. With the available software, however, only semi-automated deconvolution was enabled, which rendered data interpretation a laborious and time-consuming process.
Aim: GC/MS is a well established method in our laboratory for systematic toxicological analysis (STA) of human body fluids. Our goal was to develop an untargeted LC/MS/MS assay to complement the existing GC/MS screening assay. Methods: The LC/MS/MS approach developed for untargeted screening analysis used MS/MS under data-dependent acquisition control (DDA) to identify compounds by subsequent library search. Samples were processed by a generic solid-phase extraction method. The eluate was split for parallel GC/MS and LC/MS/MS analysis. Results: By analysing blank samples, spiked samples, certified reference materials, proficiency test samples and authentic casework samples, the performance of the developed LC/MS/MS screening procedure was characterized and compared to GC/MS screening. The experimental results clearly proved that the additional use of LC/MS/MS analysis increased the reliability of STA results. Conclusion: The developed procedure employing parallel GC/MS and LC/MS/MS analysis of processed human body fluids represents a competent approach for comprehensive STA and was successfully integrated in our laboratory services.