Fluoroscopy guided interventions, such as transjugular intrahepatic portosystemic shunt (TIPS) procedures. can result in relatively high radiation doses to patients and staff. The purpose of this study was to evaluate the possible benefit of dedicated fluoroscopy exposure factors in the reduction of doses. Doses to patients and staff were measured during fluoroscopy-guided TIPS procedures in two Dutch university hospitals. Patient doses were calculated from dose-area product (DAF) measurements, entrance beam dimensions and DAP conversion factors. Staff doses were measured outside lead aprons using electronic personal dosemeters. Average patient entrance skin dose (ESD) rate during fluoroscopy was 49 mGy min(-1) (13 cases, average fluoroscopy duration 32 min) in one hospital, and 6 mGy min(-1) (10 cases, average fluoroscopy duration 50 min) in the other. Estimated staff effective dose per procedure was 28 mu Sv average in the first hospital compared with 4 mu Sv average in the other. The use of dedicated fluoroscopy exposure factors, with a relatively high tube voltage and lower tube current resulted in a significant dose reduction for patient and staff in this type of radiological intervention.
Quality control (QC) is becoming increasingly important in relation to the introduction of digital medical imaging systems using X rays. It was, therefore, decided to organise and perform a trial on image quality and physical measurements. The SENTINEL toolkit for QC measurements of fluoroscopy systems containing equipment and instructions for their use in the assessment of dose and image quality circulated among participants in the trial. The participants reported on their results. In the present contribution, the impact of the trial on the selected protocols is presented. The Medical Physics and Bioengineering protocol appeared to be useful for QC, and also for digital systems. The protocol needs an additional section, or an addition to each section, to state compliance with the requirements. The circular cross-sections of the Leeds test objects need adaptation for rectangular flat panel detector (FPD) systems. Only one participant was able to perform the monitor test using MoniQA. This is due to the fact that assistance is required from the suppliers of the X-ray systems. This problem needs to be solved to apply MoniQA in practice.
A personal dosemeter issued for individual monitoring is calibrated in terms of personal dose equivalent, usually H(P)(10). In general it yields a reasonable estimate of effective dose (E) when the exposed person does not wear protective clothing. In interventional cardiology, however, a lead equivalent apron is worn and often a thyroid collar. A correction factor will then be necessary to convert a dosemeter reading to E. To explore this factor an interventional cardiology procedure is simulated based on exposure conditions typical for a modern hospital in the BENELUX area. The dose to the cardiologist is investigated using Monte Carlo simulation of radiation transport. It is concluded that a personal dosemeter may best be worn outside the apron at a central position high on the chest for least dependence on the beam direction. It will overestimate E by roughly a factor of 20 (apron and thyroid collar of 0.25 mm Pb).
Paediatric patients represent a very specific group within the radiology department. Compared to adult patients, they are more sensitive to radiation. As they are sometimes submitted to several radiology procedures, dose and image quality should be well balanced. Nowadays, only a few centres specialize in paediatric imaging, and knowledge of paediatric patient doses is, therefore, very scattered. The effect of the introduction of digital technology on paediatric patient doses remains largely undocumented. Data collected in the present survey illustrate that there is a clear need for standardisation in this domain. The proposal of a European diagnostic reference level (DRL) is quite difficult. Preliminary DRLs, based on typically 5-7 radiology centres per examination are proposed. The 'effective dose' may or may not be a very rigorous parameter, but it still remains useful nowadays to calculate a parameter that summarises the possible radiation-induced detriment to these young patients. However, conversion factors for calculation of the effective dose should be harmonised. Future studies should include an image quality evaluation study, using criteria that account for digital equipment. Data collection would be straightforward and could be performed in a systematic and automatic way if DICOM headers of digital images would include appropriate as well as relevant information for the particular case of paediatric examinations.
Effective dose (E) is a convenient quantity to estimate the stochastic risk of radiation applied to patients in interventional procedures and can be used for optimisation. Relatively long exposure times may cause deterministic effects. Hence it is necessary to know the (maximum local) doses in organs owing to the interventional procedure. In practice, organ doses cannot be measured directly. They are derived by applying a conversion coefficient to a measurable quantity, e.g. dose-area product (DAP) or entrance skin dose. For a number of interventional procedures, dose conversion coefficients (DCCs) can be found in the literature. Various DCCs are stated for nominally equal procedures, e.g. for percutaneous transluminal coronary angioplasty both 0.18 and 0.27 mSv Gy(-1) cm(-2) were reported to convert DAP to effective dose. Dependence of DCC on protocol and equipment parameters, as demonstrated through Monte Carlo simulation in this paper, makes it hazardous to simply adopt a literature value.
In most countries of the European Union legislation requires individual determination and registration of the dose to radiological workers exposed to ionising radiation to check whether dose limits are exceeded. To assess stochastic risk, ideally effective dose (E) should be known. In practice, personal dose equivalent [Hp(10)] is used as it can be measured with a personal dosemeter. The dosemeter reading may provide a reasonable assessment of Hp(10), but it may deviate strongly from E, in particular in radiology procedures for medical diagnosis or intervention when protective clothing like lead-equivalent apron and thyroid collar is worn. In the literature various correction factors and algorithms to convert readings of single or dual dosemeters to an estimate of E can be found. An illustrative example of a cardiac catheterisation procedure, in which dose calculations are made by Monte Carlo simulation of radiation transport, shows that such corrections may still yield considerable overestimation.
Radiation risk has to be justified and optimised. This study discusses the radiation risk of uterine artery embolisation (UAE) for the treatment of fibroids. A total of 70 consecutive UAE dosimetry parameters were assessed. Using Monte Carlo simulation, organ and effective doses and dose conversion coefficients (DCCs) (mSv Gy cm(-2)) were calculated. During UAE optimisation, avoidance of oblique views and use of last-image-hold (LIH) documentation instead of digital subtraction angiography (DSA) were investigated. Mean dose-area product (DAP) was 37.1 Gy cm(2) (median 23.7 Gy cm(2)) and mean fluoroscopy time was 18.4 min (median 16.6 min). Dose values decreased as the study progressed: mean DAP for patients 1-21, 68.5 Gy cm(2); patients 22-43, 35.7 Gy cm(2); and patients 44-69, 13.0 Gy cm(2). Average DCC for DSA image procedures was 0.572, yielding a mean effective dose of 29.6 mSv (median 17.1 mSv). For LIH-only procedures, an average DCC of 0.813 was estimated [using mean effective dose: 10.6 mSv (median 8.1 mSv)].
The goal of this study was estimation of patient effective dose from uterine artery embolization of leiomyomata. Parameters and data relevant to patient dose were recorded for 33 consecutive procedures. Using Monte Carlo simulation of radiation transport, organ and effective doses were calculated in detail for a subset of five procedures, to estimate the effective dose for all procedures. Mean dose area product was 59.9, median 23.4, and range 8.8-317.5 Gycm(2). Mean absorbed ovarian dose was calculated as 51 mGy in the five procedures. Using the dose conversion factor estimated from the Monte Carlo simulation for all procedures a mean estimated effective dose of 34 mSv (median 13 mSv, range 5-182 mSv) results, with a tendency to lower values regarding the succession of the procedures. Patients' radiation exposure level is up to twice of that of an abdominal CT examination. Angiographic equipment related dose-reducing features and radiographic technique essentially influence organ doses and effective dose. Consistent application of dose-reducing techniques and awareness of radiation exposure justifies uterine artery embolization as a therapeutic option for the treatment of uterine fibroids.
The Ninth Symposium on Neutron Dosimetry has been expanded to cover not only neutron radiation but heavy charged particle dosimetry as well. The applications are found in such fields as radiation protection, aircrew dosimetry, medicine, nuclear power and accelerator health physics. Scientists from many countries from around the world presented their work, and described the latest developments in techniques and instrumentation.
Monte Carlo (MC) simulation of radiation transport is applied to an anthropomorphic mathematical (ADAM) or Zubal's voxel phantom, representing a male adult. The purpose is to compare absorbed energy in various organs (liver, kidneys, lungs, pancreas, spleen, adrenals and heart) in the simplified (mathematical) and more realistic (voxel) anatomy. A broad beam of monodirectional and monoenergetic photons (20 keV to 10 MeV), perpendicular to the longitudinal body axis, is incident on the front (AP) or the back (PA) of the phantom. Two MC codes, MCNP-4C and MCNPX-2.1.5, are used for the calculations. Specific absorbed fraction as a function of energy reflects the shielding of an organ by other organs. Comparison of the results for the two phantoms enables an evaluation of the applicability and the limitations of ADAM with respect to radiological protection. The cases studied indicate no urgent need to replace the (commonly used) mathematical phantom by a more sophisticated voxel phantom.
Effective dose is an important quantity in relation to assessment of radiation risk. Organ and effective doses to paediatric patients undergoing diagnostic and therapeutic heart catheterization procedures can be assessed by combining relatively simple measurements, e.g. of dose-area product (DAP), and calculated dose conversion factors (DCF). This also holds for the radiation dose to the hospital staff, e.g. the cardiologist. Monte Carlo (MC) simulation of radiation transport in mathematical anthropomorphic phantoms is used to obtain the DCFs, which strongly depend on beam quality and geometrical parameters. The performance of a dedicated fast MC code (PCXMC) for patient dosimetry is compared with that of a more elaborate general purpose MC code (MCNP). Resulting organ doses sometimes may differ considerably, partly due to phantom differences. While MCNP uses separate male and female mathematical phantoms, PCXMC uses a hermaphrodite. However, both codes yield effective doses that agree rather well, so PCXMC can be used for convenience. The MCNP code is used to calculate the effective dose to the cardiologist exposed to radiation scattered from the patient. Without protective clothing, effective dose per procedure to the cardiologist is at least two orders of magnitude lower than that to the patient. The effectiveness of various types and thickness of protective clothing has been evaluated for one view of one cardiac catheterization. The results of the calculations do not contradict experimental studies from the literature. MC simulation may serve as a useful tool to improve the accuracy of estimating occupational effective dose from personal dose monitors.
Patient radiation dose in angiography of the renal arteries was assessed and optimized after installing new radiological equipment. In three separate studies (n=50, 25 and 20) patient exposure was monitored in detail. For the first study default factory settings were used, for the second the number of digital subtraction angiography (DSA) images was halved and the X-ray beam filtering during fluoroscopy was increased, and for the third study filtering during DSA was increased as well. Standard projections were derived and used in Monte Carlo simulations to derive dose conversion coefficients to calculate effective dose from the dose-area product (DAP). Dose conversion coefficients were also calculated for CT angiography (CTA). Using default factory settings on the new angiography system, DAP, number of images and effective dose were much higher than on the replaced unit. For the studies given above, DAP was reduced from 144 Gy cm(2) to 65 Gy cm(2) to 32 Gy cm(2), and effective dose from 22 mSv to 11 mSv to 9.1 mSv, respectively. Effective dose due to CTA was 5.2 mSv. It is concluded that modern angiography systems, resulting in high customer satisfaction, may readily cause much higher patient exposure than older systems. These doses may also be much higher than necessary. Optimization before putting such systems into use is absolutely essential. Internationally accepted recommendations for image quality and technique factors in angiography would be of great help.
A new and relatively simple method is presented to distribute total dose-area product (DAP) over a number of projections that model exposure during double contrast barium enema (DCBE) examinations. In addition, hitherto unavailable entrance and effective doses to the physician performing the DCBE examination have been determined. DAP, fluoroscopy time, number of images as well as some patient data were collected for 150 DCBE examinations. For a subset of 50 examinations, the distribution of DAP over 12 hypothetical but representative projections was estimated by measuring the entrance dose in the centre of each of these projections during the complete procedure. Effective dose to the patient was obtained using DAP to effective dose conversion coefficients calculated for each of the 12 projections. Exposure of the worker was quantified by measuring the entrance dose at the forehead, neck, arms, right hand and legs. The sex-averaged effective dose to the patient per examination was 6.4+/-2.1 mSv (mean+/-SD; n=50) and the corresponding DAP was 44+/-22 Gy cm(2). The effective dose to the worker per examination was 0.52 microGy (n=50), whereas the highest entrance dose of 30+/-25 microGy was found for the right arm. The proposed method for deriving the distribution of total DAP over a set of representative projections is much less time consuming than visual observation of patient exposure, whilst accuracy seems acceptable. Entrance and effective doses per examination for workers in DCBE examinations are very low. For a normal workload, doses remain far below the legally established dose limits.
This study aims at accurate quantification of x-ray exposure and effective dose to the patient in abdominal arteriography. Using an automatic monitoring system, all relevant exposure parameters were determined during 172 abdominal arteriographies. Common projections were extracted for a 'normal' reference group of procedures and used in Monte Carlo calculations of dose-area product to organ dose conversion coefficients. Dose-area product, organ doses and effective dose were quantified for intravenous and intra-arterial procedures. The large data sets describing exposure could be condensed to a set of 28 common views. New coefficients to convert dose area product to organ equivalent dose and effective dose were calculated for nine views contributing approximately 80% to the total dose-area product. The average dose-area product was 32 Gy cm2 in intravenous procedures and 47 Gy cm2 in intra-arterial procedures. The corresponding average effective doses to the patient were 4 mSv and 6 mSv respectively (range 2-12 mSv, actual value depending on procedure type and gender). It is concluded that automatic monitoring of x ray exposure parameters, complemented by the calculation of Monte Carlo organ dose conversion coefficients, is a feasible and promising approach to accurate dosimetry of complex arteriographic procedures.
This study aimed to quantify effective dose (E) for occupationally exposed persons (workers) in diagnostic and interventional arteriography. Using Monte Carlo radiation transport calculations, new air kerma to organ dose conversion coefficients (DCCs) were determined. Taking attenuation by protective clothing into account, E was estimated from the DCCs and entrance doses measured at forehead, neck, thorax, abdomen, upper arms, hands and lower legs of the workers. Average E was calculated for several types of procedures and for three hospitals. For operators, E was between 0.5 and 7 mu Sv per procedure for undercouch X ray tubes and between 0.8 and 22 mu Sv for overcouch tubes. For assistants, E was typically a factor of two lower. Wearing a thyroid collar roughly reduced E by 50%. These values are low, which is due, among other things, to the nearly general use of a mechanical contrast injector and an undercouch X ray tube.
Micturating cystourethrography (MCU) examinations of paediatric patients in a major Dutch children's hospital (JKZ) were evaluated to generate quantitative information on effective dose (E). A standard examination involves three radiographs plus fluoroscopy. Observed total dose-area product (DAP) for 84 children increased, on average, with increasing age class from 0.2 to 2.2 Gy cm2. In 11 cases, separate DAP per view was measured; enabling determination, per view, of organ (CF) and effective (CE) dose conversion factors, i.e. dose per unit of DAP. Monte Carlo simulation of photon transport in male and female mathematical phantoms was applied for newborn, 1 year, 5 year, 10 year and 15-year-old patients, and interpolated for other ages. CE per view decreases with increasing age class, yielding about a factor of 10 difference between the extremes of the range. Female values are usually some 20-30% above male ones. CE for one of the views appeared to be representative for the complete examination and was used to estimate total E for each patient. Averaged per age class, E remains approximately constant at 0.3-0.4 mSv, although a tendency to increase with increasing age exists, for females in particular. Within an age class, individual patients may differ in E by a factor of two up to six. Stomach, lower large intestine, bladder wall, liver and ovaries receive relatively high doses. Compared with published data and DAP measured in a few other Dutch hospitals, the radiation burden of MCU is low at the JKZ. This indicates a good degree of optimization with respect to radiation protection (e.g. modern equipment, increased tube voltage, fast film-screen combination).
The objective of this study was to derive the effective dose to patients from examinations of the upper gastrointestinal (GI) tract at 11 X-ray units in 10 Dutch hospitals. Entrance dose and entrance dose rate were measured at the surface of a homogeneous PMMA phantom and at the entrance surface of the image intensifier. Dose-area products (DAPs) were assessed during examinations of patients. The patients (334 females and 256 males) ages were 18-95 years (average 52 years). Effective dose was assessed from DAP using Monte Carlo computer calculations for male and female mathematical anthropomorphic phantoms. The DAPs measured during the survey showed substantial variations, i.e. an overall average value of 21 Gy cm(2) and a range of average DAP per X-ray unit varying from 7 to 56 Gy cm(2). Variations in the number of images (8-28) and the fluoroscopy time (1.7 min-7.0 min) were also large. A DAP to effective dose conversion factor of 0.32 mSv Gy cm(-2) was derived for upper GI studies. The dose survey yielded an overall average effective dose of 6.7 mSv. At one location an examination involving as many as 28 projections was performed, whilst maintaining a DAP well below 15 Gy cm(2) and an effective dose below 6 mSv. This was achieved using modern equipment (i.e. high frequency generator, digital spot films) with 0.2 mm additional copper filtration and a relatively high tube voltage. For examinations of the upper GI tract, the application of a reference value of 30 Gy cm(2) for the DAP will ensure that, in general, the effective dose to individual patients will not exceed 15 mSv.
For broad antero-posterior beams of monoenergetic (0.1-10 MeV) electrons organ doses per unit fluence were computed through Monte Carlo simulation in a reference male and female adult and a 7 year old girl. Effective doses (E) per unit fluence were calculated for the three phantoms and for an average adult. E increases from about 8x10(-14) to about 1.2 x 10(-10) Sv.cm(2) with increasing electron energy. Uncertainties were (often much) better than 6% for the adults, and 18% for the child. E as calculated for the average adult may be used for both males and females as under- or overestimations stay within 25% from E for the average adult. The child's radiation risk is underestimated for electron energies in the range of 0.6 to 3 MeV. This underestimation up to a factor of about 20 is unacceptable for radiological protection purposes. The present results were compared with literature data on operational quantities associated with radiation hazard from weakly penetrating radiation. Neither directional nor personal dose equivalent appears to be a realistic quantity in this case. Both would yield an unnecessarily large safety factor for radiological protection.