The DePFET Sensor with Signal Compression (DSSC) is an ultra-fast, large area X-ray imager presently being developed for the European XFEL. The demanding conditions at XFEL require the qualification of the individual pixel response over the full dynamics with adequate accuracy. We used bunches of mono-energetic protons (n = 1, 2, 3, ... ) as an absolute reference to validate the energy calibration of the DSSC pixel response over the full dynamics, normally achieved by means of electrical pulsing, X-ray reference lines and/or optical injection (e.g. IR laser).
The DePFET Sensor with Signal Compression (DSSC) instrument is a 1 Mpixel camera under development at the European XFEL for the detection of low-energy X-rays (<;6 keV). In this work an experimental study of charge collection effects has been carried out as a function of the deposited charge in order to extract the true time profile of the collected charge cloud in a wide range of experimental conditions. A preliminary set of results is presented and discussed.
In this work we compare different calibration sources and focus on their combination to optimize the calibration of large-format X-ray imagers over a wide range. This activity is carried out in the framework of the DSSC project and the primary aim is the calibration of the DSSC camera. We considered pulsed IR laser, radioactive sources, X-ray tube, electrical injection devices, X-ray synchrotron beam, low-energy protons, LED sources. The relevant features (deposited energy and pulse width) are critically summarized and calibration strategies will be discussed.
Using observations of the INTErnational Gamma-Ray Astrophysics Laboratory (INTEGRAL), we place upper limits on the gamma-ray and hard X-ray prompt emission associated with the gravitational wave event GW150914, which was discovered by the LIGO/Virgo Collaboration. The omnidirectional view of the INTEGRAL/SPI-ACS has allowed us to constrain the fraction of energy emitted in the hard X-ray electromagnetic component for the full high-probability sky region of LIGO triggers. Our upper limits on the hard X-ray fluence at the time of the event range from F-gamma = 2 x 10(-8) erg cm(-2) to F-gamma = 10(-6) erg cm(-2) in the 75 keV-2 MeV energy range for typical spectral models. Our results constrain the ratio of the energy promptly released in gamma-rays in the direction of the observer to the gravitational wave energy E-gamma/E-GW < 10(-6). We discuss the implication of gamma-ray limits for the characteristics of the gravitational wave source, based on the available predictions for prompt electromagnetic emission.
We successfully evaluated the possibility of using a pulsed monoenergetic proton beam as a diagnostic tool for semiconductor detectors' response mapping at high charge densities. In order to ease the setup of the detector under test we explored the opportunity of performing tests with protons in air. We qualified a polyimide film window (Upilex-S, 7.5 μm nominal thickness) as proton extraction window and the energy loss in air as a function of distance. The tests have been carried out in vacuum first, in order to evaluate the energy loss due to the window only, followed by in-air tests aimed at the investigation of the total energy degradation of the extracted proton beam.
The DEPFET Sensor with Signal Compression (DSSC) will be a 2d 1Mpx imaging detector for the European X-ray Free Electron Laser facility (XFEL.EU), that is currently under construction in Hamburg. The DSSC is foreseen as a photon counting detector for soft X-ray radiation from 0.5 keV up to 6 keV. Driven by its scientific requirements, the design goals of the detector system are foremost low noise, a high dynamic range and a high frame rate of up to 4.5 MHz. Signal compression, amplification and digitization will be performed in the focal plane. Utilizing an in-pixel active filtering stage and an 8/9-bit ADC, the detector will provide parallel readout of all pixels. A critical step of calibrating the detector is the determination of the system gain and offset based on peak energies of X-ray calibration line sources such as 55 Fe. This is demanding due to the intrinsically low spectral resolution of the DSSC. The results of studies on the stability and performance of automated procedures for peak fitting in single pixel spectra with a low energy resolution were presented on a poster.
We give a detailed account of the theoretical analysis and the experimental results of an X-ray-diffraction experiment on quantum-state selected and strongly laser-aligned gas-phase ensembles of the prototypical large asymmetric rotor molecule 2,5-diiodobenzonitrile, performed at the Linac Coherent Light Source [Phys. Rev. Lett.112, 083002 (2014)]. This experiment is the first step toward coherent diffractive imaging of structures and structural dynamics of isolated molecules at atomic resolution, i.e., picometers and femtoseconds, using X-ray free-electron lasers.
Unraveling the complex morphology of functional materials like core-shell nanoparticles and its evolution in different environments is still a challenge. Only recently has the single-particle coherent diffraction imaging (CDI), enabled by the ultrabright femtosecond free-electron laser pulses, provided breakthroughs in understanding mesoscopic morphology of nanoparticulate matter. Here, we report the first CDI results for Co@SiO2 core-shell nanoparticles randomly clustered in large airborne aggregates, obtained using the x-ray free-electron laser at the Linac Coherent Light Source. Our experimental results compare favourably with simulated diffraction patterns for clustered Co@SiO2 nanoparticles with similar to 10 nm core diameter and similar to 30 nm shell outer diameter, which confirms the ability to resolve the mesoscale morphology of complex metastable structures. The findings in this first morphological study of core-shell nanomaterials are a solid base for future time-resolved studies of dynamic phenomena in complex nanoparticulate matter using x-ray lasers.
The simulation of PIXE (Particle Induced X-ray Emission) is discussed in the context of general-purpose Monte Carlo systems for particle transport. Dedicated PIXE codes are mainly concerned with the application of the technique to elemental analysis, but they lack the capability of dealing with complex experimental configurations. General-purpose Monte Carlo codes provide powerful tools to model the experimental environment in great detail, but so far they have provided limited functionality for PIXE simulation. This paper reviews recent developments that have endowed the Geant4 simulation toolkit with advanced capabilities for PIXE simulation, and related efforts for quantitative validation of cross sections and other physical parameters relevant to PIXE simulation.
Diffractive imaging with free-electron lasers allows structure determination from ensembles of weakly scattering identical nanoparticles. The ultra-short, ultra-bright X-ray pulses provide snapshots of the randomly oriented particles frozen in time, and terminate before the onset of structural damage. As signal strength diminishes for small particles, the synthesis of a three-dimensional diffraction volume requires simultaneous involvement of all data. Here we report the first application of a three-dimensional spatial frequency correlation analysis to carry out this synthesis from noisy single-particle femtosecond X-ray diffraction patterns of nearly identical samples in random and unknown orientations, collected at the Linac Coherent Light Source. Our demonstration uses unsupported test particles created via aerosol self-assembly, and composed of two polystyrene spheres of equal diameter. The correlation analysis avoids the need for orientation determination entirely. This method may be applied to the structural determination of biological macromolecules in solution.
The plasma dynamics of single mesoscopic Xe particles irradiated with intense femtosecond x-ray pulses exceeding 10(16) W/cm2 from the Linac Coherent Light Source free-electron laser are investigated. Simultaneous recording of diffraction patterns and ion spectra allows eliminating the influence of the laser focal volume intensity and particle size distribution. The data show that for clusters illuminated with intense x-ray pulses, highly charged ionization fragments in a narrow distribution are created and that the nanoplasma recombination is efficiently suppressed.
The resolution of single-shot coherent diffractive imaging at X-ray free-electron laser facilities is limited by the low signal-to-noise level of diffraction data at high scattering angles. The iterative reconstruction methods, which phase a continuous diffraction pattern to produce an image, must be able to extract information from these weak signals to obtain the best quality images. Here we show how to modify iterative reconstruction methods to improve tolerance to noise. The method is demonstrated with the hybrid input-output method on both simulated data and single-shot diffraction patterns taken at the Linac Coherent Light Source.
Nature 486, 513–517 (2012); doi:10.1038/nature11222 In this Letter, author M. S. Hunter was incorrectly listed as M. M. Hunter; this has been corrected online in the PDF and HTML of the original paper.
The DSSC (DEPFET Sensor with Signal Compression) is a new instrument with non-linear compression of the input signal in the sensor and with parallel signal processing (filtering, linear amplification, and digitization) for all pixels. The DSSC will serve as 2d imaging detector at the European X-ray Free Electron Laser (XFEL.EU) currently under construction in Hamburg, Germany. The DSSC design goal is to achieve at the same time single photon detection and high dynamic range of about 10(4) photons, both for photon energies down to 0.5 keV and read-out speeds up to 4.5 MHz. Realization of this goal requires an accurate calibration of the non-linear system response (NLSR) over the full dynamic range of the detector. We present our strategy for calibrating the NLSR, for each of the 1024 x 1024 DSSC pixels, in the laboratory. The feasibility of our calibration strategy is demonstrated experimentally by calibrating the NLSR of a DSSC prototype set-up consisting of a prototype DEPFET sensor with non-linear signal compression connected to a prototype read-out ASIC.
We present validation measurements for the Geant4 radioactive decay simulation following a self-consistent approach. The validation is based 011 gamma spectroscopy measurements with HPGe and Nal detectors. In addition we present a re-designed radioactive decay simulation for Geant4, with extended functionality, such as support for long term activation, and programmed to modern coding standards.
Ongoing investigations for the improvement of Geant4 accuracy and computational performance resulting by refactoring and reengineering parts of the code are discussed. Issues in refactoring that are specific to the domain of physics simulation are identified and their impact is elucidated. Preliminary quantitative results are reported.
The assessment of the reliability of Monte Carlo simulations is discussed, with emphasis on uncertainty quantification and the related impact on experimental results.Methods and techniques to account for epistemic uncertainties, i.e. for intrinsic knowledge gaps in physics modeling, are discussed with the support of applications to concrete experimental scenarios.Ongoing projects regarding the investigation of epistemic uncertainties in the Geant4 simulation toolkit are reported.
The emergence of femtosecond diffractive imaging with X-ray lasers has enabled pioneering structural studies of isolated particles, such as viruses, at nanometer length scales.However, the issue of missing low frequency data significantly limits the potential of X-ray lasers to reveal sub-nanometer details of micrometer-sized samples.We have developed a new technique of dark-field coherent diffractive imaging to simultaneously overcome the missing data issue and enable us to harness the unique contrast mechanisms available in dark-field microscopy.Images of airborne particulate matter (soot) up to two microns in length were obtained using single-shot diffraction patterns obtained at the Linac Coherent Light Source, four times the size of objects previously imaged in similar experiments.This technique opens the door to femtosecond diffractive imaging of a wide range of micrometer-sized materials that exhibit irreproducible complexity down to the nanoscale, including airborne particulate matter, small cells, bacteria and gold-labeled biological samples.
We describe the results obtained with Target of Opportunity observations of the galactic sources SGR 1627–41 and 1E 1547–5408. These two transients show several similarities supporting the interpretation of Anomalous X-ray Pulsars and Soft Gamma-ray Repeaters as a single class of strongly magnetized neutron stars.