Decay heat released from radioactive waste residing in a future geological disposal facility (GDF) poses many challenges, including long-term geological integrity and high temperature gradients in the rock. This paper presents a novel technique to remove decay heat from a GDF, by utilising a 1 km U-loop closed-loop geothermal system. A lower-strength sedimentary rock (LSSR) environment was adopted using the T2WellECO2N/TOUGH2 software suite to represent a notional UK high-heat producing waste (HHPW) disposal programme. Within the LSSR environment, three source terms were assessed representative of: pressurised water reactor (PWR), advanced gas-cooled reactor (AGR), and European pressurized reactor (EPR) types. These were assessed for static (no wellbore flow) and dynamic (wellbore activated) scenarios. Sensitivity analyses for the latter involved varying fixed mass flow rate and source term distance from the wellbore lateral to predict excess decay heat removal and end lateral temperatures. An initial software comparison was made against code developed in MATLAB and the OpenGeoSys (OGS) software, to assess a dynamic 10-year setup for 30 fuel canisters. The comparison revealed relative errors of 7.8 % (MATLAB) and 2.3 % (OGS) for end lateral temperatures after 10 years against T2Well. The sensitivity analyses revealed that at 1.2 m below the wellbore, inclusion of the 1 km single lateral closed-loop geothermal system (CLGS) saw a temperature reduction of 26.6 degrees C (PWR), 22.8 degrees C (AGR) and 32.6 degrees C (EPR) from the rock after 11 years. Reducing peak temperatures of the source term could improve overall safety of the GDF by mitigating unwanted processes.
Decarbonisation of heat is essential to meeting net zero carbon targets; however, fluctuating renewable resources, such as wind or solar, may not meet peak periods of demand. Therefore, methods of underground thermal energy storage can aid in storing heat in low demand periods to be exploited when required. Borehole thermal energy storage (BTES) is an important technology in storing surplus heat and the efficiency of such systems can be strongly influenced by groundwater flow. In this paper, the effect of groundwater flow on a single deep borehole heat exchanger (DBHEs) was modelled using OpenGeoSys (OGS) software to test the impact of varying regional Darcy velocities on the performance of heat extraction and BTES. It is anticipated that infrastructure such as ex-geothermal exploration or oil and gas development wells approaching the end of life could be repurposed. These systems may encounter fluid flow in the subsurface and the impact of this on single well deep BTES has not previously been investigated. Higher groundwater velocities can increase the performance of a DBHE operating to extract heat only for a heating season of 6 months. This is due to the reduced cooling of rocks in proximity to the DBHE as groundwater flow replenishes heat which has been removed from the rock volume around the borehole (this can also be equivalently thought of as “coolth” being transported away from the DBHE in a thermal plume). When testing varying Darcy velocities with other parameters for a DBHE of 920 m length in rock of thermal conductivity 2.55 W/(m·K), it was observed that rocks with larger Darcy velocity (1e-6 m/s) can increase the thermal output by up to 28 kW in comparison to when there is no groundwater flow. In contrast, groundwater flow inhibits single well deep BTES as it depletes the thermal store, reducing storage efficiency by up to 13% in comparison to models with no advective heat transfer in the subsurface. The highest Darcy velocity of 1e-6 m/s was shown to most influence heat extraction and BTES; however, the likelihood of this occurring regionally, and at depth of around or over 1 km is unlikely. This study also tested varying temporal resolutions of charge and cyclicity. Shorter charge periods allow a greater recovery of heat (c. 34% heat injected recovered for 1 month charge, as opposed to <17% for 6 months charge).
Accurate nuclear data are essential in the evaluation of decay heat from spent nuclear fuel (SNF). The accuracy of such data was assessed using an approach that compares values reported in different evaluated libraries and determines whether discrepancies reflect inaccuracies in primary data. A short list of 43 isotopes which are most significant to SNF decay heat calculations over 1–100 k years was produced by combining generic reactor inventory code with decay heat analysis for undifferentiated SNF. Decay properties (half-lives and decay energies) and neutron interactions (cross section and fission yields) were compared from 6 evaluated libraries. Fission product (FP) discrepancies identified are 90Sr half-life, where inclusion of a single measurement significantly reduces the evaluated value; 95mNb beta energy, where DDEP evaluation omits the decay to the 95Mo ground state; 99Tc beta energy, where evaluations differ by approximately 10% with a variety of shape factors used; 126Sb/126mSb beta (JEF2.2/3.1.1/3.3) and electron energies (JEFF3.1.1), where intensity differences are reported; and 137Cs beta energy, where ENDF/B-VIII.0 and JEF3.3 evaluations use incorrect shape factors. For actinides, the major discrepancies identified were 237Np alpha energy (JEF2.2/3.1.1) and 225Ac electron energies (ENDF/B-VIII.0) but overall show less discrepancies during long-term disposal (0.1–100 ky) compared to FP’s during interim storage (1–100 years). Further assessments of the 90Sr half-life and the best shape factor for the 99Tc beta decay are needed to improve future decay heat analyses, which are important for designing future stores and evaluating schemes for possible heat recovery.
Geothermal energy is a reliable and mature energy source, but it represents less than 1% of the total renewable energy mix. While the enhanced geothermal system (EGS) concept faces technical validation challenges and suffers from public acceptance issues, the development of unconventional deep-well designs can help to improve their efficiency and reliability. Modelling single-EGS-well designs is key to assessing their long-term thermal performances, particularly in unconventional geological settings. Numerical results obtained with the T2WELL/EOS1 code have been validated with available experimental data from a deep borehole heat exchanger (DBHE), where a temperature of 358 ∘C has been measured at a depth of 1962 m. Based on a calibrated model, the thermal performances of two enhanced thermal conductive DBHEs with graphite were compared for high geothermal gradients. The analysis highlights the potential recovery of a variable fraction of vapour. Graphite used along the well appears to be the most suitable solution to enhance the thermal output by 5 to 8% when compared to conventional wells. The theoretical implementation of such well in the Newberry volcano field was investigated with a single and doublet DBHE. The findings provide a robust methodology to assess alternative engineering solutions to current geothermal practices.
Alternative (unconventional) deep geothermal designs are needed to provide a secure and efficient geothermal energy supply. An in-depth sensitivity analysis was investigated considering a deep borehole closed-loop heat exchanger (DBHE) to overcome the current limitations of deep EGS. A T2Well/EOS1 model previously calibrated on an experimental DBHE in Hawaii was adapted to the current NWG 55-29 well at the Newberry volcano site in Central Oregon. A sensitivity analysis was carried out, including parameters such as the working fluid mass flow rate, the casing and cement thermal properties, and the wellbore radii dimensions. The results conclude the highest energy flow rate to be 1.5 MW, after an annulus radii increase and an imposed mass flow rate of 5 kg/s. At 3 kg/s, the DBHE yielded an energy flow rate a factor of 3.5 lower than the NWG 55-29 conventional design. Despite this loss, the sensitivity analysis allows an assessment of the key thermodynamics within the wellbore and provides a valuable insight into how heat is lost/gained throughout the system. This analysis was performed under the assumption of subcritical conditions, and could aid the development of unconventional designs within future EGS work like the Newberry Deep Drilling Project (NDDP). Requirements for further software development are briefly discussed, which would facilitate the modelling of unconventional geothermal wells in supercritical systems to support EGS projects that could extend to deeper depths.
This session will provide ‘an introduction to mitigating solutions’ such as carbon sources and sinks, heat sources and sinks, and reducing our individual carbon footprints.