BACKGROUND:Dose prediction has great potential in improving plan quality and efficiency by estimating optimal dose distribution. However, most existing deep learning (DL) based dose prediction models for intensity-modulated radiation therapy (IMRT) have been primarily developed under simplified conditions, such as fixed beam configuration and/or disease site. These constraints limit the generalizability and clinical usability of such models across the diverse scenarios encountered in real-world practice. PURPOSE:We proposed a DL-based universal dose prediction model, named UniDose, designed to accommodate a wide range of disease sites and support diverse clinical scenarios, especially for IMRT treatment plans with arbitrary beam configurations. METHODS:UniDose is built on a customized nnU-Net framework, adapted into an image-to-image mapping network tailored for 3D dose prediction and trained using the Huber loss. The network takes three generalized input channels: a normalized prescription dose map that encodes planning goals for the target, a weighted avoidance mask that consolidates multiple organs at risk (OARs) and body structures into a single channel with clinical relevance-based voxel weights, and a beam trace image that captures beam configuration using a non-modulated, cumulative dose approximation generated via a ray-tracing based algorithm. The model was trained, validated and tested on a heterogeneous dataset of 871 patients encompassing 25 disease sites and a wide spectrum of prescription doses and beam configurations. To assess the deliverability of the predicted dose, we incorporated a reference-based in-house optimization engine into the UniDose framework to generate feasible plans constrained by machine limitations. Model performance was evaluated by comparing predicted doses, optimized doses, and clinical plans using gamma passing rate (GPR) with a 3%/2 mm criteria and 10% lower dose threshold and dose-volume histogram (DVH) metrics. RESULTS:The UniDose predictions achieved an average GPR of 92.36% compared to the optimized doses and demonstrated strong DVH consistency. The average GPR between predicted and clinical doses was 86.13%. DVH comparisons showed that the predictions and the optimized dose achieved improved OAR sparing while maintaining comparable target coverage relative to clinical dose, particularly in prostate, liver, and brain cases. Case studies across six disease sites with variable beam configurations further confirmed that the predicted and optimized doses exhibited similar dose deposition patterns along beam paths, suggesting that the predicted dose is physically feasible and approachable following dose optimization. Additionally, adjusting voxel weights in the avoidance input channel enabled flexible trade-offs between OAR sparing and target coverage, supporting patient-specific treatment planning. CONCLUSIONS:UniDose demonstrates strong potential as a universal DL-based dose prediction framework capable of generalizing across diverse disease sites and beam configurations. By combining a generalized input design, robust network customization, and integration with a reference-guided optimization engine, UniDose generates physically feasible dose predictions and allows efficient user interaction through adjustable input conditions.
BACKGROUND:Currently, proton therapy is the main radiation treatment modality that can treat deeply seated targets at ultra-high dose rates. The safe translation of FLASH RT into clinic requires dedicated dosimeters capable of measurements at sufficiently high spatiotemporal resolution. PURPOSE:The objective of this work is to demonstrate the feasibility of three-dimensional (3D) measurements of dose rate and dose for FLASH pencil beam scanning (PBS) proton therapy. METHODS:A multi-layer strip ionization chamber (MLSIC) device, along with a reconstruction algorithm, was designed and developed to reconstruct dose and dose rate distribution over a 3D volume. Our MLSIC is composed of 66 layers of strip ionization chamber arrays with total water-equivalent thickness (WET) of 19.2 cm along the beam direction. The first two layers, composed of 128 channels with orthogonal direction with respect to each other, provide the (x,y) coordinate. The other 64 layers contain 32 channels with 8 mm lateral spacing. Data readout at a high-speed of 6250 fps allows spot-by-spot measurement. To prove the concept, PBS proton therapy plans were delivered at conventional and FLASH dose rates. Dose and dose rate information were reconstructed in 3D using an in-house reconstruction algorithm. RESULTS:Ion recombination remained under 1% in the majority of cases. 3D dose reconstruction showed agreement with the treatment planning software; the 3D gamma analysis of the reconstructed dose showed 96.2% (5 mm/5%) and 86.8% (3 mm/3%) passing rates with 10% threshold for the conventional dose rate plan, 99.1% (5 mm/5%) and 92.6% (3 mm/3%) passing rates for the FLASH dose rate plan. 3D dose rate distributions were successfully generated using different definitions. CONCLUSIONS:Our MLSIC device allows obtaining 3D dose and dose rate distribution of PBS proton beams at FLASH dose rates with high spatiotemporal resolution.
Objective. In current clinical practice for quality assurance (QA), intensity modulated proton therapy (IMPT) fields are verified by measuring planar dose distributions at one or a few selected depths in a phantom. A QA device that measures full 3D dose distributions at high spatiotemporal resolution would be highly beneficial for existing as well as emerging proton therapy techniques such as FLASH radiotherapy. Our objective is to demonstrate feasibility of 3D dose measurement for IMPT fields using a dedicated multi-layer strip ionization chamber (MLSIC) device.Approach.Our developed MLSIC comprises a total of 66 layers of strip ion chamber (IC) plates arranged, alternatively, in thexandydirection. The first two layers each has 128 channels in 2 mm spacing, and the following 64 layers each has 32/33 IC strips in 8 mm spacing which are interconnected every eight channels. A total of 768-channel IC signals are integrated and sampled at a speed of 6 kfps. The MLSIC has a total of 19.2 cm water equivalent thickness and is capable of measurement over a 25 × 25 cm2field size. A reconstruction algorithm is developed to reconstruct 3D dose distribution for each spot at all depths by considering a double-Gaussian-Cauchy-Lorentz model. The 3D dose distribution of each beam is obtained by summing all spots. The performance of our MLSIC is evaluated for a clinical pencil beam scanning (PBS) plan.Main results.The dose distributions for each proton spot can be successfully reconstructed from the ionization current measurement of the strip ICs at different depths, which can be further summed up to a 3D dose distribution for the beam. 3D Gamma Index analysis indicates acceptable agreement between the measured and expected dose distributions from simulation, Zebra and MatriXX.Significance.The dedicated MLSIC is the first pseudo-3D QA device that can measure 3D dose distribution in PBS proton fields spot-by-spot.
A novel inverse-geometry CT based on multi-pixel thermionic emission x-ray (MPTEX) sources is under development. Inverse-geometry CT is capable of modulating x-ray flux based on region of interest (ROI) location and thus minimizing x-ray exposure to the patients. The variations of emission currents of the MPTEX source at each projection angle are predetermined based on ROI position and realized by varying filament heating powers. To power and control filament electron emissions, a 50-channel prototype MPTEX control unit was developed based on GaN switching power technology. The filament heating powers of electron sources are controlled individually by a microprocessor while electron emission is turned on and off by switching the bias voltages during inverse-geometry CT scans. The emission current was measured as a function of filament heating voltage. The result shows that magnitude of emission current can be controlled dynamically by varying filament heating voltages. Compared with pulse width modulation, this approach can effectively prolong the lifetime of the filaments by minimizing their working temperature. A simulation of electron emission current sinogram was conducted as well. This work is supoorted by NIH grant R42EB026401.
Active matrix, flat-panel imagers (AMFPIs) suffer from decreased detective quantum efficiency under conditions of low dose per image frame (such as for digital breast tomosynthesis, fluoroscopy and cone-beam CT) due to low signal compared to the additive electronic noise. One way to address this challenge is to introduce a high-gain x-ray converter called particle-in-binder mercuric iodide (PIB HgI2) which exhibits 3-10 times higher x-ray sensitivity compared to that of a-Se and CsI:Tl converters employed in commercial AMFPI systems. However, a remaining challenge for practical implementation of PIB HgI2is the high level of image lag, which is believed to largely originate from the trapping of holes. Towards addressing this challenge, this paper reports a theoretical investigation of the use of a Frisch grid structure embedded in the converter to suppress hole signal-which would be expected to reduce image lag. The grid acts as a third electrode sandwiched between a continuous top electrode and pixelated bottom electrodes having a 100μm pitch. Signal properties of such a detector are investigated as a function of VDR (the ratio of the voltage difference between the electrodes in the region below the grid to that above the grid), grid pitch (the center-to-center distance between two neighboring grid wires) andRGRID(the ratio of grid wire width to grid pitch) for mammographic x-ray energies. The results show that smaller grid pitch suppresses hole signal to a higher degree (up to ∼96%) while a larger gap between grid wires and higher VDR provide minimally impeded electron transport. Examination of the tradeoff between maximizing electron signal and minimizing hole signal indicates that a grid design having a grid pitch of 20μm withRGRIDof 50% and 65% provides hole signal suppression of ∼93% and ∼95% for VDR of 1 and 3, respectively.
PURPOSE:In modern radiotherapy treatment rooms, megavoltage (MV) portal imaging and kilovoltage (kV) cone-beam CT (CBCT) imaging are performed using various active matrix flat-panel imager (AMFPI) designs. To expand the clinical utility of MV and kV imaging, MV AMFPIs incorporating thick, segmented scintillators and, separately, kV imaging using a beam's eye view geometry have been investigated by a number of groups. Motivated by these previous studies, it is of interest to explore to what extent it is possible to preserve the benefits of kV and MV imaging using a single AMFPI design, given the considerably different x ray energy spectra used for kV and MV imaging. In this paper, considerations for the design of such a dual energy imager are explored through examination of the performance of a variety of hypothetical AMFPIs based on x ray converters employing segmented scintillators.METHODS:Contrast, noise, and contrast-to-noise ratio performances were characterized through simulation modeling of CBCT imaging, while modulation transfer function, Swank factor, and signal performance were characterized through simulation modeling of planar imaging. The simulations were based on a previously reported hybrid modeling technique (accounting for both radiation and optical effects), augmented through modeling of electronic additive noise. All designs employed BGO scintillator material with thicknesses ranging from 0.25 to 4 cm and element-to-element pitches ranging from 0.508 to 1.016 mm. A series of studies were performed under both kV and MV imaging conditions to determine the most advantageous imager configuration (involving front or rear x ray illumination and use of a mirror or black reflector), converter design (pitch and thickness), and operating mode (pitch-binning combination).RESULTS:Under the assumptions of the present study, the most advantageous imager design was found to employ rear illumination of the converter in combination with a black reflector, incorporate a BGO converter with a 0.508 mm pitch and a 2 cm thickness, and operate at full resolution for kV imaging and 2 × 2 binning mode for MV imaging. Such a dual energy imager design should provide soft tissue visualization at low, clinically practical doses under MV conditions, while helping to preserve the high spatial resolution and high contrast offered by kV imaging.CONCLUSIONS:The authors' theoretical investigation suggests that a dual energy imager capable of largely preserving the desirable characteristics of both kV and MV imaging is feasible. Such an imager, when coupled to a dual energy radiation source, could facilitate simplification of current treatment room imaging systems (as well as their associated quality assurance), and facilitate more precise integration of kV and MV imaging information by virtue of reduced geometric uncertainties.
Over the last ~15 years, the central goal in external beam radiotherapy of maximizing dose to the tumor while minimizing dose to surrounding normal tissues has been greatly facilitated by the development and clinical implementation of many innovations. These include megavoltage active matrix flat-panel imagers (MV AMFPIs) designed to image the treatment beam, and separate kilovoltage (kV) AMFPIs and x-ray sources designed to provide high-contrast projection and cone-beam CT images in the treatment room. While these systems provide clinically valuable information, a variety of advantages would accrue through introduction of the capability to produce clinically useful, high quality imaging information at multiple energies (e.g., kV and MV) from a single detector along the treatment beam direction. One possible approach for achieving this goal involves substitution of the x-ray converters used in conventional MV AMFPIs with thick, segmented crystalline scintillators designed for dual-energy operation, coupled with the addition of x-ray imaging beams that contain a significant diagnostic component. A second approach involves introduction of a large area, monolithic array of photon counting pixels with multiple energy thresholds and event counters, which could provide multi-spectral views of the treatment beam with improved contrast. In this paper, the motivations behind, and the merits of each approach are described. In addition, prospects for such dual-energy imagers and photon counting array designs are discussed in the context of the radiotherapy environment.
Thick, segmented crystalline scintillators have shown increasing promise as replacement x-ray converters for the phosphor screens currently used in active matrix flat-panel imagers (AMFPIs) in radiotherapy, by virtue of providing over an order of magnitude improvement in the detective quantum efficiency (DQE). However, element-to-element misalignment in current segmented scintillator prototypes creates a challenge for optimal registration with underlying AMFPI arrays, resulting in degradation of spatial resolution. To overcome this challenge, a methodology involving the use of a relatively high resolution AMFPI array in combination with novel binning techniques is presented. The array, which has a pixel pitch of 0.127 mm, was coupled to prototype segmented scintillators based on BGO, LYSO and CsI:Tl materials, each having a nominal element-to-element pitch of 1.016 mm and thickness of ∼ 1 cm. The AMFPI systems incorporating these prototypes were characterized at a radiotherapy energy of 6 MV in terms of modulation transfer function, noise power spectrum, DQE, and reconstructed images of a resolution phantom acquired using a cone-beam CT geometry. For each prototype, the application of 8 × 8 pixel binning to achieve a sampling pitch of 1.016 mm was optimized through use of an alignment metric which minimized misregistration and thereby improved spatial resolution. In addition, the application of alternative binning techniques that exclude the collection of signal near septal walls resulted in further significant improvement in spatial resolution for the BGO and LYSO prototypes, though not for the CsI:Tl prototype due to the large amount of optical cross-talk resulting from significant light spread between scintillator elements in that device. The efficacy of these techniques for improving spatial resolution appears to be enhanced for scintillator materials that exhibit mechanical hardness, high density and high refractive index, such as BGO. Moreover, materials that exhibit these properties as well as offer significantly higher light output than BGO, such as CdWO4, should provide the additional benefit of preserving DQE performance.
The thin-film semiconductor processing methods that enabled creation of inexpensive liquid crystal displays based on amorphous silicon transistors for cell phones and televisions, as well as desktop, laptop and mobile computers, also facilitated the development of devices that have become ubiquitous in medical x-ray imaging environments. These devices, called active matrix flat-panel imagers (AMFPIs), measure the integrated signal generated by incident X rays and offer detection areas as large as ~43×43 cm2. In recent years, there has been growing interest in medical x-ray imagers that record information from X ray photons on an individual basis. However, such photon counting devices have generally been based on crystalline silicon, a material not inherently suited to the cost-effective manufacture of monolithic devices of a size comparable to that of AMFPIs. Motivated by these considerations, we have developed an initial set of small area prototype arrays using thin-film processing methods and polycrystalline silicon transistors. These prototypes were developed in the spirit of exploring the possibility of creating large area arrays offering single photon counting capabilities and, to our knowledge, are the first photon counting arrays fabricated using thin film techniques. In this paper, the architecture of the prototype pixels is presented and considerations that influenced the design of the pixel circuits, including amplifier noise, TFT performance variations, and minimum feature size, are discussed.
PURPOSE:Active matrix flat-panel imagers (AMFPIs) incorporating thick, segmented scintillators have demonstrated order-of-magnitude improvements in detective quantum efficiency (DQE) at radiotherapy energies compared to systems based on conventional phosphor screens. Such improved DQE values facilitate megavoltage cone-beam CT (MV CBCT) imaging at clinically practical doses. However, the MV CBCT performance of such AMFPIs is highly dependent on the design parameters of the scintillators. In this paper, optimization of the design of segmented scintillators was explored using a hybrid modeling technique which encompasses both radiation and optical effects.METHODS:Imaging performance in terms of the contrast-to-noise ratio (CNR) and spatial resolution of various hypothetical scintillator designs was examined through a hybrid technique involving Monte Carlo simulation of radiation transport in combination with simulation of optical gain distributions and optical point spread functions. The optical simulations employed optical parameters extracted from a best fit to measurement results reported in a previous investigation of a 1.13 cm thick, 1016 μm pitch prototype BGO segmented scintillator. All hypothetical designs employed BGO material with a thickness and element-to-element pitch ranging from 0.5 to 6 cm and from 0.508 to 1.524 mm, respectively. In the CNR study, for each design, full tomographic scans of a contrast phantom incorporating various soft-tissue inserts were simulated at a total dose of 4 cGy.RESULTS:Theoretical values for contrast, noise, and CNR were found to be in close agreement with empirical results from the BGO prototype, strongly supporting the validity of the modeling technique. CNR and spatial resolution for the various scintillator designs demonstrate complex behavior as scintillator thickness and element pitch are varied--with a clear trade-off between these two imaging metrics up to a thickness of ~3 cm. Based on these results, an optimization map indicating the regions of design that provide a balance between these metrics was obtained. The map shows that, for a given set of optical parameters, scintillator thickness and pixel pitch can be judiciously chosen to maximize performance without resorting to thicker, more costly scintillators.CONCLUSIONS:Modeling radiation and optical effects in thick, segmented scintillators through use of a hybrid technique can provide a practical way to gain insight as to how to optimize the performance of such devices in radiotherapy imaging. Assisted by such modeling, the development of practical designs should greatly facilitate low-dose, soft tissue visualization employing MV CBCT imaging in external beam radiotherapy.
Active matrix flat-panel imagers (AMFPIs) have become ubiquitous in medical imaging environments. AMFPIs are based on two-dimensional pixelated arrays coupled to various x-ray converter materials that provide either indirect or direct detection of the incident x-ray radiation. However, the capabilities of this technology are severely constrained by the underlying solid-state properties of the amorphous silicon semiconductor material employed in the thin-film transistors present in each array pixel. The considerably higher electron and hole mobilities of polycrystalline silicon, a semiconductor material that (like amorphous silicon) is well suited to fabrication of transistors for large area electronics, provide the potential to overcome these constraints by increasing the overall gain of the system relative to the electronic additive noise. To explore this potential, a series of prototype arrays based on increasingly complex pixel designs employing polycrystalline silicon transistors is under development by our collaboration. The designs include several generations of active pixel arrays that incorporate sophisticated pixel-level amplifier circuits with the goal of improving imaging performance. In this paper, an initial analysis of the noise and DQE performance of selected prototype pixel circuit designs will be presented. The results are based on a combination of Monte Carlo -based circuit simulations and cascaded systems analysis, supplemented with information obtained from measurements performed on poly-Si transistors. The paper concludes with a brief discussion of the potential for, and challenges associated with, the creation of single photon counting arrays based on poly-Si TFTs.
Active matrix flat-panel imagers (AMFPIs) offer many advantages and have become ubiquitous across a wide variety of medical x-ray imaging applications. However, for mammography, the imaging performance of conventional AMFPIs incorporating CsI:Tl scintillators or a-Se photoconductors is limited by their relatively modest signal-to-noise ratio (SNR), particularly at low x-ray exposures or high spatial resolution. One strategy for overcoming this limitation involves the use of a high gain photoconductor such as mercuric iodide (HgI2) which has the potential to improve the SNR by virtue of its low effective work function (W-EFF). In this study, the performance of direct-detection AMFPI prototypes employing relatively thin layers of polycrystalline HgI2 operated under mammographic irradiation conditions over a range of 0.5 to 16.0 mR is presented. High x-ray sensitivity (corresponding to W-EFF values of similar to 19 eV), low dark current (<0.1 pA mm(-2)) and good spatial resolution, largely limited by the size of the pixel pitch, were observed. For one prototype, a detective quantum efficiency of similar to 70% was observed at an x-ray exposure of similar to 0.5 mR at 26 kVp.
The imaging performance of active matrix flat-panel imagers designed for megavoltage imaging (MV AMFPIs) is severely constrained by relatively low x-ray detection efficiency, which leads to a detective quantum efficiency (DQE) of only ∼1%. Previous theoretical and empirical studies by our group have demonstrated the potential for addressing this constraint through the utilization of thick, two-dimensional, segmented scintillators with optically isolated crystals. However, this strategy is constrained by the degradation of high-frequency DQE resulting from spatial resolution loss at locations away from the central beam axis due to oblique incidence of radiation. To address this challenge, segmented scintillators constructed so that the crystals are individually focused toward the radiation source are proposed and theoretically investigated. The study was performed using Monte Carlo simulations of radiation transport to examine the modulation transfer function and DQE of focused segmented scintillators with thicknesses ranging from 5 to 60 mm. The results demonstrate that, independent of scintillator thickness, the introduction of focusing largely restores spatial resolution and DQE performance otherwise lost in thick, unfocused segmented scintillators. For the case of a 60 mm thick BGO scintillator and at a location 20 cm off the central beam axis, use of focusing improves DQE by up to a factor of ∼130 at non-zero spatial frequencies. The results also indicate relatively robust tolerance of such scintillators to positional displacements, of up to 10 cm in the source-to-detector direction and 2 cm in the lateral direction, from their optimal focusing position, which could potentially enhance practical clinical use of focused segmented scintillators in MV AMFPIs.
Active matrix flat-panel imagers (AMFPIs) have become ubiquitous across a wide variety of medical x-ray imaging applications. While AMFPIs based on both direct and indirect detection of the incident radiation offer many advantages, their performance is limited by relatively modest system gain compared to electronic additive noise. The effects of this limitation upon imaging performance become particularly apparent at lower exposures and/or at higher spatial frequencies. One potential strategy for overcoming this limitation involves the use of a high gain photoconductor such as mercuric iodide (HgI2) which has the potential to improve system gain by up to an order of magnitude compared to that provided by a-Se, the only photoconductor material presently used in direct detection AMFPIs. In this paper, preliminary results from an investigation of the performance of a prototype direct detection AMFPI employing a relatively thin layer of polycrystalline HgI2 created through a screen-printing method and operated under mammographic irradiation conditions are presented. The results encourage further examination of this strategy to improve the performance of AMFPIs designed for mammography.
Megavoltage, cone-beam computed tomography (MV CBCT) employing an electronic portal imaging device (EPID) is a highly promising technique for providing soft-tissue visualization in image-guided radiotherapy. However, current EPIDs based on active matrix flat-panel imagers (AMFPIs), which are regarded as the gold standard for portal imaging and referred to as conventional MV AMFPIs, require high radiation doses to achieve this goal due to poor x-ray detection efficiency (∼2% at 6 MV). To overcome this limitation, the incorporation of thick, segmented, crystalline scintillators, as a replacement for the phosphor screens used in these AMFPIs, has been shown to significantly improve the detective quantum efficiency (DQE) performance, leading to improved image quality for projection imaging at low dose. Toward the realization of practical AMFPIs capable of low dose, soft-tissue visualization using MV CBCT imaging, two prototype AMFPIs incorporating segmented scintillators with ∼11 mm thick CsI:Tl and Bi(4)Ge(3)O(12) (BGO) crystals were evaluated. Each scintillator consists of 120 × 60 crystalline elements separated by reflective septal walls, with an element-to-element pitch of 1.016 mm. The prototypes were evaluated using a bench-top CBCT system, allowing the acquisition of 180 projection, 360° tomographic scans with a 6 MV radiotherapy photon beam. Reconstructed images of a spatial resolution phantom, as well as of a water-equivalent phantom, embedded with tissue equivalent objects having electron densities (relative to water) varying from ∼0.28 to ∼1.70, were obtained down to one beam pulse per projection image, corresponding to a scan dose of ∼4 cGy--a dose similar to that required for a single portal image obtained from a conventional MV AMFPI. By virtue of their significantly improved DQE, the prototypes provided low contrast visualization, allowing clear delineation of an object with an electron density difference of ∼2.76%. Results of contrast, noise and contrast-to-noise ratio are presented as a function of dose and compared to those from a conventional MV AMFPI.
A highly portable high-speed CAMAC data acquisition system has been developed using Kmax software (Sparrow, Inc.) for Macintosh laptop and tower computers. It uses a USB-2 interface to the CAMAC crate controller with custom-written software drivers. Kmax permits 2D parameter gating and specific algorithms have been developed to facilitate the rapid evaluation of various multi-element nuclear detectors for energy and time-of-flight measurements. This includes tests using neutrons from 252Cf and a 2.5MeV neutron generator as well as standard gamma calibration sources such as 60Co and 137Cs. In addition, the system has been used to measure gamma–gamma coincidences over extended time periods using radioactive sources (e.g., Ra-228, Pa-233, Np-237, and Am-243).
A decade after the clinical introduction of active matrix, flat-panel imagers (AMFPIs), the performance of this technology continues to be limited by the relatively large additive electronic noise of these systems - resulting in significant loss of detective quantum efficiency (DQE) under conditions of low exposure or high spatial frequencies. An increasingly promising approach for overcoming such limitations involves the incorporation of in-pixel amplification circuits, referred to as active pixel architectures (AP) - based on low-temperature polycrystalline silicon (poly-Si) thin-film transistors (TFTs). In this study, a methodology for theoretically examining the limiting noise and DQE performance of circuits employing 1-stage in-pixel amplification is presented. This methodology involves sophisticated SPICE circuit simulations along with cascaded systems modeling. In these simulations, a device model based on the RPI poly-Si TFT model is used with additional controlled current sources corresponding to thermal and flicker (1/f) noise. From measurements of transfer and output characteristics (as well as current noise densities) performed upon individual, representative, poly-Si TFTs test devices, model parameters suitable for these simulations are extracted. The input stimuli and operating-point-dependent scaling of the current sources are derived from the measured current noise densities (for flicker noise), or from fundamental equations (for thermal noise). Noise parameters obtained from the simulations, along with other parametric information, is input to a cascaded systems model of an AP imager design to provide estimates of DQE performance. In this paper, this method of combining circuit simulations and cascaded systems analysis to predict the lower limits on additive noise (and upper limits on DQE) for large area AP imagers with signal levels representative of those generated at fluoroscopic exposures is described, and initial results are reported.
Angular distributions for the elastic scattering of $^{8}\mathrm{B}$, $^{7}\mathrm{Be}$, and $^{6}\mathrm{Li}$ on a $^{12}\mathrm{C}$ target have been measured at ${E}_{\mathrm{lab}}=25.8$, 18.8, and 12.3 MeV, respectively. The analyses of these angular distributions have been performed in terms of the optical model using Woods-Saxon and double-folding type potentials. The effect of breakup in the elastic scattering of ${}^{8}\mathrm{B}+{}^{12}\mathrm{C}$ is investigated by performing coupled-channels calculations with the continuum discretized coupled-channel method and cluster-model folding potentials. Total reaction cross sections were deduced from the elastic-scattering analysis and compared with published data on elastic scattering of other weakly and tightly bound projectiles on $^{12}\mathrm{C}$, as a function of energy. With the exception of $^{4}\mathrm{He}$ and $^{16}\mathrm{O}$, the data can be described using a universal function for the reduced cross sections.