The ATLAS collaboration is upgrading its detector for High-Luminosity LHC (HL-LHC) operations scheduled to start in 2029. This involves making a new all-silicon tracker, called Inner Tracker (ITk), with instrumented strip area of 165 m2.The strip sensor type is n-on-p, chosen because of its radiation hardness and a relative fabrication simplicity. So far, this technology has not been used in large-scale experiments. Many years of R&D investigations and pre-production experience showed that it works well, with the specification of the maximum operational voltage of 500 V. The sensors, however, show sensitivity to ambient humidity, e.g. reduced breakdown voltage at relative humidity (RH) values of about 40% and above. This is an issue for testability, but not for real operations, where RH is very low. Therefore, the collaboration adopted the strategy of dry storage, testing, and shipment for sensors and related assembled components: modules, staves, and petals. A few days long exposure to ambient air during assembly was shown to be tolerable.The dry handling strategy becomes much more difficult to implement during the tracker integration, when barrels and disks are put together in large-size cleanrooms with RH range between 50 and 70%. The duration of each of numerous integration steps is several weeks, followed by testing. The effect of such long humidity exposures on the sensor properties was unknown. Therefore, we commenced a study of repeated sensor exposures to 75% RH. We chose 32 sensors for the study from different deliveries, and with different pedigrees in terms of initial performance on reception and recovery procedures used. Progressively longer exposures ranged between 4 and 266 days in duration. The cumulative exposure time was up to 2 years. No performance deterioration was seen, as evaluated by the visual inspection, IV characteristics, and other checks. We report the details of the tests, results, and implications.
The Quality Control (QC) of pre-production strip sensors for the Inner Tracker (ITk) of the ATLAS Inner Detector upgrade has finished, and the collaboration has embarked on the QC test programme for production sensors. This programme will last more than 3 years and comprises the evaluation of approximately 22000 sensors. 8 Types of sensors, 2 barrel and 6 endcap, will be measured at many different collaborating institutes. The sustained throughput requirement of the combined QC processes is around 500 sensors per month in total. Measurement protocols have been established and acceptance criteria have been defined in accordance with the terms agreed with the supplier. For effective monitoring of test results, common data file formats have been agreed upon across the collaboration. To enable evaluation of test results produced by many different test setups at the various collaboration institutes, common algorithms have been developed to collate, evaluate, plot and upload measurement data. This allows for objective application of pass/fail criteria and compilation of corresponding yield data. These scripts have been used to process the data of more than 3000 sensors so far, and have been instrumental for identification of faulty sensors and monitoring of QC testing progress.
The ATLAS experiment is constructing new all-silicon inner tracking system for HL-LHC. The strip detectors cover the radial extent of 40 to 100 cm. A new approach is adopted to use p-type silicon material, making the readout in n + -strips, so-called n + -in-p sensors. This allows for enhanced radiation tolerance against an order of magnitude higher particle fluence compared to the LHC. To cope with varying hit rates and occupancies as a function of radial distance, there are two barrel sensor types, the short strips (SS) for the inner 2 and the long strips (LS) for the outer 2 barrel cylinders, respectively. The barrel sensors exhibit a square, 9.8 × 9.8 cm 2 , geometry, the largest possible sensor area from a 6-inch wafer. The strips are laid out in parallel with a strip pitch of 75.5 μm and 4 or 2 rows of strip segments. The strips are AC-coupled and biased via polysilicon resistors. The endcap sensors employ a “stereo-annulus” geometry exhibiting a skewed-trapezoid shapes with circular edges. They are designed in 6 unique shapes, R0 to R5, corresponding to progressively increasing radial extents and which allows them to fit within the petal geometry and the 6-inch wafer maximally. The strips are in fan-out geometry with an in-built rotation angle, with a mean pitch of approximately 75 μm and 4 or 2 rows of strip segments. The eight sensor types are labeled as ATLAS18xx where xx stands for SS, LS, and R0 to R5. According to the mechanical and electrical specifications, CAD files for wafer processing were laid out, following the successful designs of prototype barrel and endcap sensors, together with a number of optimizations. A pre-production was carried out prior to the full production of the wafers. The quality of the sensors is reviewed and judged excellent through the test results carried out by vendor. These sensors are used for establishing acceptance procedures and to evaluate their performance in the ATLAS collaboration, and subsequently for pre-production of strip modules and stave and petal structures.
The high-luminosity upgrade of the Large Hadron Collider, scheduled to become operational in 2029, requires the replacement of the ATLAS Inner Detector with a new all-silicon Inner Tracker. Radiation hard n+-in-p micro-strip silicon sensors were developed by the ATLAS Inner Tracker strip collaboration and are produced by Hamamatsu Photonics K.K. Production of the total amount of 22000 strip sensors has started in 2020 and will continue until 2025. The ATLAS strip sensor collaboration has the responsibility to monitor the quality of the fabricated devices by performing detailed measurements of individual sensor characteristics and by comparing the obtained results with the tests done by the manufacturer. Dedicated Quality Control procedures were developed to check whether the delivered large-format sensors adhere to the ATLAS specifications. The institutes performing the Quality Control testing of the pre-production and production ATLAS ITk strip sensors had to initially be qualified for multiple high-throughput tests by successfully completing the Site Qualification process. The Quality Control procedures and the qualification process are described in this paper.
For the Phase-II Upgrade of the ATLAS Detector, the Inner Detector will be replaced with the Inner Tracker (ITk), consisting of a pixel and a strip tracker. The 17,888 silicon strip detector modules comprising the ITk strip tracker will be assembled from silicon strip sensors and flexes with readout chips in a manual assembly process performed at 20 module assembly sites in a complex distribution chain, which requires quality control steps to be performed after each distribution and assembly step. Sensor quality control requires a visual inspection of the full sensor area (about 100 cm 2 ) of each sensor to detect and log any defects (e.g. scratches, breakdown areas or chipped corners) or contamination. Since manual surveys of full sensor areas for several thousand sensors are both time-consuming and prone to errors, alternative methods were investigated to automate the process and improve its reliability. This paper presents a setup developed to take high-resolution images of full silicon strip sensors with high repeatability quickly and an algorithm developed for the automated detection of defects, built using functions and filters from popular open-source visual processing packages OpenCV and Scikit-image. Methods were developed both for small-scale high-resolution images and full-size sensor images with lower resolution — both are presented here.
In preparation for the High Luminosity LHC (HL-LHC) runs, the ATLAS inner detector will be completely replaced with an all silicon Inner Tracker (ITk). Hybrid silicon pixel modules will be used for the innermost tracking layers, and silicon micro-strip detectors will be used the outer layers of the tracker. During the production of the detector, the sensors, readout electronics, and other components will undergo a series of quality control (QC) and quality assurance tests. Defects in the fabrication of the sensors will be flagged early in the manufacturer's and ATLAS QC tests. A study of the influence of sensor defects was performed to assess the characteristics of these defects in completed modules, and whether any defect posed a risk to the operation of the front-end readout electronics. All defects were found to have no impact on the performance of the front-end readout electronics for healthy amplifier channels, and defects that short the coupling between the strip implant and the metal readout electrode were only noticeable for strip leakage currents in excess of 250 nA, beyond the end-of-life currents expected for most sensors at the HL-LHC.
For the Phase-II Upgrade of the ATLAS Detector [1], its Inner Detector, consisting of silicon pixel, silicon strip and transition radiation sub-detectors, will be replaced with an all new 100% silicon tracker, composed of a pixel tracker at inner radii and a strip tracker at outer radii. The future ATLAS strip tracker will include 11,000 silicon sensor modules in the central region (barrel) and 7,000 modules in the forward region (end-caps), which are foreseen to be constructed over a period of 3.5 years. The construction of each module consists of a series of assembly and quality control steps, which were engineered to be identical for all production sites. In order to develop the tooling and procedures for assembly and testing of these modules, two series of major prototyping programs were conducted: an early program using readout chips designed using a 250 nm fabrication process (ABCN-250) [2, 3] and a subsequent program using a follow-up chip set made using 130 nm processing (ABC130 and HCC130 chips). This second generation of readout chips was used for an extensive prototyping program that produced around 100 barrel-type modules and contributed significantly to the development of the final module layout. This paper gives an overview of the components used in ABC130 barrel modules, their assembly procedure and findings resulting from their tests.
The inner tracker of the ATLAS detector is scheduled to be replaced by a completely new silicon-based inner tracker (ITk) for the Phase-II of the CERN LHC (HL-LHC). The silicon strip detector covers the volume 40 < R < 100 cm in the radial and vertical bar z vertical bar <300 cm in the longitudinal directions. The silicon sensors for the detector will be fabricated using the n(+)-on-p 6-inch wafer technology, for a total of 22,000 wafers. Intensive studies were carried out on the final prototype sensors ATLAS17LS fabricated by Hamamatsu Photonics (HPK). The charge collection properties were examined using penetrating Sr-90 beta-rays and the ALIBAVA fast readout system for the miniature sensors of 1 cm xl cm in area. The samples were irradiated by protons in the 27 MeV Birmingham Cyclotron, the 70 MeV CYRIC at Tohoku University, and the 24 GeV CERN-PS, and by neutrons at Ljubljana TAIGA reactor for fluence values up to 2 x 10(15) n(eq)/cm(2). The change in the charge collection with fluence was found to be similar to the previous prototype ATLAS12, and acceptable for the ITk. Sensors with two active thicknesses, 300 mu m (standard) and 240 mu m (thin), were compared and the difference in the charge collection was observed to be small for bias voltages up to 500 V. Some samples were also irradiated with gamma radiation up to 2 MGy, and the full depletion voltage was found to decrease with the dose. This was caused by the Compton electrons due to the( 60)Co gamma radiation. To summarize, the design of the ATLAS17LS and technology for its fabrication have been verified for implementation in the ITk. We are in the stage of sensor pre-production with the first sensors already delivered in January of 2020.
ATLAS experiment is preparing an upgrade of its detector for High-Luminosity LHC (HL-LHC) operation. The upgrade involves installation of the new all-silicon Inner Tracker (ITk). In the context of the ITk preparations, more than 80 strip modules were built with prototype barrel sensors. They were tested with electrical readout on a per-channel basis. In general, an excellent performance was observed, consistent with previous ASIC-level and sensor-level tests. However, the lessons learned included two phenomena important for the future phases of the project. First was the need to store and test the modules in a dry environment due to humidity sensitivity of the sensors. The second was an observation of high noise regions for 2 modules. The high noise regions were tested further in several ways, including monitoring the performance as a function of time and bias voltage. Additionally, direct sensor-level tests were performed on the affected channels. The inter-strip resistance and bias resistance tests showed low values, indicating a temporary loss of the inter-strip isolation. A subsequent recovery of the noise performance was observed. We present the test details, an analysis of how the inter-strip isolation affects the module noise, and the relationship with sensor-level quality control tests.
The high luminosity upgrade of the Large Hadron Collider, foreseen for 2027, requires the replacement of the ATLAS Inner Detector with a new all-silicon Inner Tracker (ITk). The expected total integrated luminosity of 4000 fb(-1) means that the strip part of the ITk detector will be exposed to a large radiation fluence of up to phi(eq) = 1.6 x 10(15) 1 MeV n(eq)/cm and an ionizing dose of 0.66 MGy, including a safety factor of 1.5. Radiation-hard le -in-p micro-strip sensors for use in the ITk have been developed by the ATLAS ITk Strip Sensor collaboration and produced by Hamamatsu Photonics K.K. In this paper, the results obtained from the electrical characterization of the latest barrel ATLAS17LS sensor prototype, before and after irradiation, are shown. Surface properties of the long-strip barrel, full-sized and miniature sensors have been studied before and after proton, neutron and gamma irradiation up to the maximal fluences and radiation doses specified for the ITk Strip tracker. Sensors have been irradiated by protons at CYRIC, Tohoku University (Japan), the Proton Irradiation Facility at CERN, Karlsruhe Inst. Tech. (Germany) and at the University of Birmingham (UK), by neutrons from the Ljubljana TAIGA reactor (Slovenia) and by gamma rays from the Co-60 source in UJP Praha (Czech Republic). It has been verified that the surface radiation damage does not influence the sensor functionality. The breakdown voltage is well above the maximum operational voltage. All the tested surface parameters, such as the inter-strip resistance and capacitance, coupling capacitance and bias resistance satisfy the ATLAS ITk specifications for strip sensors.