During inertial confinement fusion experiments at the National Ignition Facility (NIF), a capsule filled with deuterium and tritium (DT) gas, surrounded by a DT ice layer and a high-density carbon ablator, is driven to the temperature and densities required to initiate fusion. In the indirect method, 2 MJ of NIF laser light heats the inside of a gold hohlraum to a radiation temperature of 300 eV; thermal x rays from the hohlraum interior couple to the capsule and create a central hotspot at tens of millions degrees Kelvin and a density of 100-200 g/cm3. During the laser interaction with the gold wall, m-band x rays are produced at ∼2.5 keV; these can penetrate into the capsule and preheat the ablator and DT fuel. Preheat can impact instability growth rates in the ablation front and at the fuel-ablator interface. Monitoring the hohlraum x-ray spectrum throughout the implosion is, therefore, critical; for this purpose, a Multilayer Mirror (MLM) with flat response in the 2-4 keV range has been installed in the NIF 37° Dante calorimeter. Precision engineering and x-ray calibration of components mean the channel will report 2-4 keV spectral power with an uncertainty of ±8.7%.
We report results from frequency conversion experiments using a 1053 nm Nd:Glass laser system and a CLBO quintupler to generate fifth harmonic (211 nm) output. A peak 211 nm intensity of 0.4 GW/cm2 was measured with a fundamental drive intensity of 2.25 GW/cm2. © 2019 The Author(s)
We have demonstrated the world's highest average power, fully diode-pumped, petawatt-class peak power laser, the High-repetition-rate Advanced Petawatt Laser System (HAPLS) [1-3]. These first commissioning results at 16J (stretched) at 3%Hz fully validate projected performance of 30J/30fs (>1PW) at 10Hz. The laser has been operated at this intermediate level at Lawrence Livermore National Laboratory to demonstrate integrated performance of all subsystems and provide benchmarking data to laser performance models before further increasing energy and peak power. Data was obtained during multiple campaigns, exceeding several hours of run time, and a snapshot of 60min of data is shown in Fig. 1. The average pump laser 1ω (1053nm) energy was 97J with an rms stability of 0.7%, 2ω (527nm) energy at the Ti:sapphire power amplifier was 62J, and the average stretched short pulse energy was 16J. A full-aperture diagnostic suite allows simultaneous, single-shot measurement of energy, spectrum, beam quality, and pulse duration at full repetition rate. Single-shot SPIDER retrieved pulse shapes (Fig. 1 inset) with an average pulse duration over 12000 consecutive shots of 28.6fs (rms=1.4fs). The mean pulse duration is consistent with the measured spectral bandwidth and is ∼1.2× the transform limit. All results shown are raw data without filtering or averaging, demonstrating the exceptional pulse characteristics, repeatability, and stability of the entire laser system.
Overview of progress in construction and testing of the laser systems of ELI-Beamlines, accomplished since 2015, is presented. Good progress has been achieved in construction of all four lasers based largely on the technology of diode-pumped solid state lasers (DPSSL). The first part of the L1 laser, designed to provide 200 mJ < 15 fs pulses at 1 kHz repetition rate, is up and running. The L2 is a development line employing a 10 J / 10 Hz cryogenic gas-cooled pump laser which has recently been equipped with an advanced cryogenic engine. Operation of the L3-HAPLS system, using a gas-cooled DPSSL pump laser and a Ti: sapphire broadband amplifier, was recently demonstrated at 16 J / 28 fs, at 3.33 Hz rep rate. Finally, the 5 Hz OPCPA front end of the L4 kJ laser is up running and amplification in the Nd:glass large-aperture power amplifiers was demonstrated.
Large laser systems that deliver optical pulses with peak powers exceeding one Petawatt (PW) have been constructed at dozens of research facilities worldwide and have fostered research in High-Energy-Density (HED) Science, High-Field and nonlinear physics [1]. Furthermore, the high intensities exceeding 1018W/cm2 allow for efficiently driving secondary sources that inherit some of the properties of the laser pulse, e.g. pulse duration, spatial and/or divergence characteristics. In the intervening decades since that first PW laser, single-shot proof-of-principle experiments have been successful in demonstrating new high-intensity laser-matter interactions and subsequent secondary particle and photon sources. These secondary sources include generation and acceleration of charged-particle (electron, proton, ion) and neutron beams, and x-ray and gamma-ray sources, generation of radioisotopes for positron emission tomography (PET), targeted cancer therapy, medical imaging, and the transmutation of radioactive waste [2, 3]. Each of these promising applications requires lasers with peak power of hundreds of terawatt (TW) to petawatt (PW) and with average power of tens to hundreds of kW to achieve the required secondary source flux.
The HAPLS laser system has been commissioned to its first integrated performance milestone, delivering laser pulses with 16J sub-30fs duration at a 3⅓Hz repetition rate. This first all-diode-pumped petawatt-class laser offers the average powers required for secondary source applications.
Phase 1 performance ramping of the HAPLS pump laser, a high-energy DPSSL based on Nd:glass, successfully produced 70J at 1053nm from a single aperture and 39J at 527nm using LBO frequency converter running at 3.3Hz repetition rate.
Initial performance ramping of the HAPLS pump laser, a high-energy DPSSL based on Nd:glass, produced 70J at 1053nm from a single aperture and 39J at 527nm using LBO frequency converter all at 3.3Hz repetition rate.
The Beam Research Program at Lawrence Liver-more National Laboratory is continuing development of the dielectric wall accelerator (DWA), a type of accelerator which uses stacked pulse-forming lines (PFLs) to apply an accelerating field directly to the beam through a nonconducting vacuum boundary. Here, we report operation of a DWA as an electron diode using a surface flashover plasma cathode. Peak perveances in excess of 6 x 10(-6) A/V-3/2 were measured, with current extraction and pulse train format depending on flashover source timing and PFL switching speed.
Compact dielectric wall (DWA) accelerator technology is being developed at the Lawrence Livermore National Laboratory. The DWA accelerator uses fast switched high voltage transmission lines to generate pulsed electric fields on the inside of a high gradient insulating (HGI) acceleration tube. Its high electric field gradients are achieved by the use of alternating insulators and conductors and short pulse times. The DWA concept can be applied to accelerate charge particle beams with any charge to mass ratio and energy. Based on the DWA system, a novel compact proton therapy accelerator is being developed. This proton therapy system will produce individual pulses that can be varied in intensity, energy and spot width. The system will be capable of being sited in a conventional linac vault and provide intensity modulated rotational therapy. The status of the developmental new technologies that make the compact system possible will be reviewed. These include, high gradient vacuum insulators, solid dielectric materials, SiC photoconductive switches and compact proton sources. Applications of the DWA accelerator to problems in homeland security will also be discussed.
A new type of compact induction accelerator is under development at the Lawrence Livermore National Laboratory that promises to increase the average accelerating gradient by at least an order of magnitude over that of existing induction machines. The machine is based on the use of high gradient vacuum insulators, advanced dielectric materials and switches and is being developed for a variety of applications. Research describing an extreme variant of this technology aimed at producing a compact, variable output linear accelerator for proton therapy for cancer will be described along with the technical challenges and issues. The goal of the development is to produce a proton accelerator that will fit in a standard linac vault and deliver intensity modulated proton therapy. Tomotherapy, Inc. has licensed the new accelerator technology from the Lawrence Livermore National Laboratory and the Compact Particle Acceleration Corporation (CPAC) is supporting development of the system. Research sponsored by Tomotherapy, Inc. and CPAC. Conflict of Interest: Some of the co‐authors have a financial interest in Tomotherapy, Inc. and/or CPAC.