The upcoming SCALES (Slicer Combined with Array of Lenslets for Exoplanet Spectroscopy) instrument for W.M. Keck Observatory will enable new imaging and low-/mid-resolution coronagraphic integral field spectroscopic observations over the wavelength range from 2-5 microns. At the heart of the instrument are two HgCdTe Teledyne Imaging H2RG detectors, designed for a 100kHz pixel clock rate (slow mode) with a fixed 4-channel readout. However, in ground-based operation at these wavelengths, the resulting minimum frame readout time will result in the infrared background saturating the detector. To enable high quality observations without saturation from the bright infrared sky background, we operate the detectors using a custom cable for buffered readout via the Teledyne Imaging SIDECAR ASIC followed by an AstroBlank/Markury Scientific MACIE controller card controlled by custom firmware. This combination allows the detector to be read out at faster pixel clock rates. This, in combination with the slow-mode H2RG, is what we characterize as hybrid fast-slow readout, enabling readout up to 18 times faster than would be possible in slow mode alone. In the UCLA Infrared Lab, we have performed room-temperature and cold tests with the H2RG detectors. We test and optimize full-frame data acquisition with pixel clock rates from 0.2-1.8 MHz. In these proceedings, we present a summary of the controller software used to operate the H2RG-ASIC-MACIE system. We present the methodology of, and preliminary results from, the UCLA tests of cryogenic operation of both H2RG detectors. We also outline the next steps in verification of detector performance, as well as integration with the SCALES instrument.
Liger is a next-generation near-infrared (0.81 - 2.45 mu m) integral field spectrograph (IFS) and imaging camera for the W. M. Keck Observatory (WMKO) adaptive optics (AO) system. The instrument concept originated by coupling designs from WMKO AO instruments and the future Thirty Meter Telescope IRIS spectrograph. Liger is designed for the Keck I telescope to operate behind the upcoming Keck All-sky Precision Adaptive optics (KAPA) system. The imaging camera sequentially feeds an IFS that makes use of slicer assembly for the coarsest sampling (75 mas and 150 mas per spaxel) and lenslet array (14 mas and 31 mas per spaxel) for diffraction-limited sampling. The imaging camera makes use of off-axis parabolas and a Hawaii-2RG detector to achieve a 14 mas/pixel plate scale and 20.5 '' x20.5 '' field of view. The IFS offers a range of spectral resolving power of R=4,000 10,000 and yields large fields of view for an AO-fed IFS. Liger will enable new science by providing enhanced capabilities, including higher spectral resolving power, access to shorter wavelengths, and larger fields of view than any current or planned ground- or space-based IFS system. Liger will be able to unlock previously inaccessible science across a wide range of the cosmos, such as dark matter substructure, supermassive black holes, the Galactic Center, exoplanet atmospheres, and the time-variable Solar System. We present the overall design of the Liger subsystems and review unique science drivers.
Liger is an adaptive optics (AO) fed imager and integral field spectrograph (IFS) designed to take advantage of the Keck All-sky Precision Adaptive-optics (KAPA) upgrade to the Keck I telescope. Liger adapts the design of the InfraRed Imaging Spectrograph (IRIS) for the Thirty Meter Telescope (TMT) to Keck by implementing a new imager and re-imaging optics. The performance of the imager is critical as it sequentially feeds the spectrograph and contains essential components such as the pupil wheel, filter wheel, and pupil viewing camera. We present the design and structural analysis of the Liger imager optical assembly including static, modal, and thermal simulations. We present the fabrication as well as the full assembly and characterization plan. The imager will be assembled bench-top in a clean room utilizing a coordinate-measuring machine (CMM) for warm alignment. To ensure optimal performance, the imager will be characterized in a test cryostat before integration with the full Liger instrument. This comprehensive approach to characterization ensures the precision and reliability of the imager, enhancing the observational capabilities of Liger and W.M. Keck Observatory.
Liger is an adaptive optics (AO)-fed imager and integral field spectrograph (IFS) designed for W.M. Keck Observatory. Liger will be coupled with the Keck All-sky Precision Adaptive-optics (KAPA) upgrade which will allow both systems to fully utilize their capabilities to maximize scientific return for the broader community. Liger features a custom-designed imaging camera that sequentially feeds the pristine AO image to two select-able integral field spectrograph (IFS) modes: an image slicer for coarse spatial sampling and a lenslet array for finer spatial scales. Both IFS modes utilize a final "camera" three-mirror anastigmat (TMA) and a Hawaii 4RG detector for data collection. This paper will discuss the assembly, integration, and testing (AIT) of the Liger instrument sub-assemblies. The project is currently in the first of two-fabrication phases where we are manufacturing, assembling, and testing the complete imager system, the IFS camera TMA, grating turret mechanism, and the IFS re-imaging optics mechanisms. The second fabrication phase will include the final fabrication and assembly of the IFS and science cryostat. An integration phase will follow where the full instrument is assembled and integrated into the science cryostat. Once complete the Liger instrument will be shipped to Hawaii for final assembly, integration, and verification at W.M. Keck Observatory.
SCALES (Slicer Combined with Array of Lenslets for Exoplanet Spectroscopy) is the next-generation, diffraction-limited, thermal infrared, fully cryogenic, coronagraphic exoplanet spectrograph and imager for W.M. Keck Observatory. SCALES is fed by the Keck II Adaptive Optics bench. Both modes use common fore-optics to simplify the optical design and have individual detectors, which are JWST flight spares. The imager mode operates from 1 to 5 microns with selectable narrow- and broadband filters over a field of view 12.3 arcseconds on a side, and the integral field spectrograph mode operates from 2 to 5 microns with both low and mid spectral resolutions (R similar to 100 to R similar to 7500) over a field of view 2.15 arcseconds on a side. The diamond-turned aluminum optics, most of which are already delivered, with the rest being fabricated, provide low distortion, low wavefront error, and high throughput for all modes. The slicing unit, located behind the lenslet array, allows SCALES to reach heretofore unheard-of spatially-resolved spectral resolution for exoplanet and disc observations from the ground with a coronagraphic integral field spectrograph. The SCALES consortium includes UC Observatories, CalTech, W.M. Keck Observatory, the Indian Institute of Astrophysics, and the University of Durham, with over 40 science team members. We report on the overall design and project status during its ongoing fabrication phase, which started in early 2023.
Liger is a second generation near-infrared imager and integral field spectrograph (IFS) for the W. M. Keck Observatory that will utilize the capabilities of the Keck All-sky Precision Adaptive-optics (KAPA) system. Liger operates at a wavelength range of 0.81 μm - 2.45 μm and utilizes a slicer and a lenslet array IFS with varying spatial plate scales and fields of view resulting in hundreds of modes available to the astronomer. Because of the high level of complexity in the raw data formats for the slicer and lenslet IFS modes, Liger must be designed in conjunction with a Data Reduction System (DRS) which will reduce data from the instrument in real-time and deliver science-ready data products to the observer. The DRS will reduce raw imager and IFS frames from the readout system and provide 2D and 3D data products via custom quick-look visualization tools suited to the presentation of IFS data. The DRS will provide the reduced data to the Keck Observatory Archive (KOA) and will be available to astronomers for offline post-processing of observer data. We present an initial design for the DRS and define the interfaces between observatory and instrument software systems.
Liger is a next-generation near-infrared imager and integral field spectrograph (IFS) planned for the W.M. Keck Observatory. Liger is designed to take advantage of improved adaptive optics (AO) from the Keck All-Sky Precision Adaptive Optics (KAPA) upgrade currently underway. Liger operates at 0.84-2.45 µm with spectral resolving powers of R∼4,000-10,000. Liger makes use of a sequential imager and spectrograph design allowing for simultaneous observations. There are two spectrograph modes: a lenslet with high spatial sampling of 14 and 31 mas, and a slicer with 75 and 150 mas sampling with an expanded field of view. Two pick-off mirrors near the imager detector direct light to these two IFS channels. We present the design and structural analysis for the imager detector and IFS pick-off mirror mounting assembly that will be used to align and maintain stability throughout its operation. A piezoelectric actuator will be used to step through 3 mm of travel during alignment of the instrument to determine the optimal focus for both the detector and pick-off mirrors which will be locked in place during normal operation. We will demonstrate that the design can withstand the required gravitational and shipping loads and can be aligned within the positioning tolerances for the optics.
Liger is an adaptive optics (AO) fed imager and integral field spectrograph (IFS) designed to take advantage of the Keck All-sky Precision Adaptive-optics (KAPA) upgrade for the W.M. Keck Observatory. We present the design and analysis of the imager optical assembly including the spectrograph Re-Imaging Optics (RIO) which transfers the beam path from the imager focal plane to the IFS slicer module and lenslet array. Each imager component and the first two RIO mechanisms are assembled and individually aligned on the same optical plate. Baffling suppresses background radiation and scattered light, and a pupil viewing camera allows the imager detector to focus on an image of the telescope pupil. The optical plate mounts on an adapter frame for alignment of the overall system. The imager and RIO will be characterized in a cryogenic test chamber before installation in the final science cryostat.
The InfraRed Imaging Spectrograph (IRIS) is a first-light instrument for the Thirty Meter Telescope (TMT) that will be used to sample the corrected adaptive optics field by the Narrow-Field Infrared Adaptive Optics System (NFIRAOS) with a near-infrared (0.8 - 2.4 µm) imaging camera and integral field spectrograph. To better understand IRIS science specifications we use the IRIS data simulator to characterize relative photometric precision and accuracy across the IRIS imaging camera 34”x34” field of view. Because the Point Spread Function (PSF) varies due to the effects of anisoplanatism, we use the Anisoplanatic and Instrumental Reconstruction of Off-axis PSFs for AO (AIROPA) software package to conduct photometric measurements on simulated frames using PSF-fitting as the PSF varies in single-source, binary, and crowded field use cases. We report photometric performance of the imaging camera as a function of the instrumental noise properties including dark current and read noise. Using the same methods, we conduct comparisons of photometric performance with reconstructed PSFs, in order to test the veracity of the current PSF-Reconstruction algorithms for IRIS/TMT.
NIRSPEC is a 1-5 micron echelle spectrograph in use on the Keck II Telescope since 1999. The spectrograph is capable of both moderate (R~2,000) and high (R~25,000) resolution observations and has been a workhorse instrument across many astronomical fields, from planetary science to extragalactic observations. In the latter half of 2018, we will upgrade NIRSPEC to improve the sensitivity and stability of the instrument and increase its lifetime. The major components of the upgrade include replacing the spectrometer and slit-viewing camera detectors with Teledyne H2RG arrays and replacing all transputer-based electronics. We present detailed design, testing, and analysis of the upgraded instrument, including the finalized optomechanical design of the new 1-5 micron slit-viewing camera, final alignment and assembly of the science array, electronics systems, and updated software design.