In the field of cardiovascular device development, new devices such as heart valves, stents or pressure probes for long term heart failure monitoring are subject to animal trials to evaluate their safety and efficacy. For such applications, swine and sheep are the animal models of choice owed to their similarities to humans with regards to heart size, weight and ventricular kinetics. However, clinical aspects regarding the choice of animal model revolve mainly around anatomical similarities as well as the ability to induce the desired pathology. In the case of pulmonary artery pressure sensors, both swine and sheep appear to be suitable candidates for animal trials since both animals have been used for pre-clinical evaluation. Hemodynamic aspects however, although equally important for device performance, appear rather underrepresented in current research and it remains uncertain whether anatomical similarities between humans and animal model in the region of interest translate to hemodynamic similarities. To provide insight whether pulmonary artery hemodynamics in large animal models are indeed comparable to those in humans, this work presents a computational fluid dynamics-based study on pulmonary artery hemodynamics for humans, swine and sheep. A total of 28 human, 41 porcine and 14 ovine transient simulations of pulmonary artery hemodynamics were performed based on subject-specific geometries reconstructed from computed tomography data. The distributions of wall shear stress (WSS) and oscillatory shear index (OSI) within the cohorts were then compared to assess hemodynamic similarity. Distributions of time averaged WSS were found to be similar between humans and sheep (median 1.2 vs. 1.5 Pa, interquartile range (IQR) 0.8 Pa vs. 0.6 Pa, Wilcoxon rank sum test p = 0.42) but were significantly different for swine (median 1.7, IQR 0.5, p < 0.05), whereas OSI was significantly different for sheep and swine (0.17 ± 0.04 vs. 0.14 ± 0.03 and 0.09 ± 0.02). between sheep and humans. In summary, pulmonary artery vessel wall stresses of both animal models appear broadly similar to humans, however, sheep seem to have a notable edge over swine in our study.
Implantable pulmonary artery pressure sensors (PAPS) might impose a flow-induced risk of thrombus formation in the pulmonary artery (PA). To assess this risk, an in silico study-enhanced animal study with 20 sensors implanted in 10 pigs had previously been conducted. In the in silico study, PAPS were virtually implanted mimicking real implantations, based upon data acquired by CT. This animal in silico study investigated changes in hemodynamics caused by PAPS using image-based computational fluid dynamics (CFD). However, porcine and human PA differ significantly in geometry and hemodynamics. To investigate the transferability of animal in silico study findings toward human conditions, we propose a parallel in silico human study. Based on a similarity analysis (L1 norm for 8 geometric features) human PA geometries with the least difference to 10 porcine PA were selected. PAPS were virtually implanted in human PA as close as possible, mimicking the implantation configuration of the animal study. Finally, a numerical flow analysis of the hemodynamic changes due to PAPS implantation was done. Comparing human and porcine PA, we found significantly larger left and right PA diameters in humans, whereas no differences were found for main PA diameters and bifurcation angle. Comparing hemodynamic boundary conditions, we found a significantly smaller heart rate and a significantly higher peak systolic main PA flow rate in humans, whereas no significant differences for cardiac output were found. The human in silico PAPS study found no relevant changes in hemodynamics increasing the risk of thrombus formation after sensor implantation. This is also valid for PAPS that were non-optimally implanted. Thus, despite differences between species, findings of the in silico animal study were confirmed by the human in silico study.
Image-based, patient-specific modelling of hemodynamics can improve diagnostic capabilities and provide complementary insights to better understand the hemodynamic treatment outcomes. However, computational fluid dynamics simulations remain relatively costly in a clinical context. Moreover, projection-based reduced-order models and purely data-driven surrogate models struggle due to the high variability of anatomical shapes in a population. A possible solution is shape registration: a reference template geometry is designed from a cohort of available geometries, which can then be diffeomorphically mapped onto it. This provides a natural encoding that can be exploited by machine learning architectures and, at the same time, a reference computational domain in which efficient dimension-reduction strategies can be performed. We compare state-of-the-art graph neural network models with recent data assimilation strategies for the prediction of physical quantities and clinically relevant biomarkers in the context of aortic coarctation.
Properties of the pulmonary artery play an essential role in the diagnosis and treatment planning of diseases such as pulmonary hypertension. Patient-specific simulation of hemodynamics can support the planning of interventions. However, the variable complex branching structure of the pulmonary artery poses a challenge for image-based generation of suitable geometries. State-of-the-art segmentation-based approaches require an interactive 3D surface reconstruction to prepare the simulation geometry. We propose a deep learning approach to generate a 3D surface mesh of the pulmonary artery from CT images suitable for simulation. The proposed method is based on the Voxel2Mesh algorithm and includes a voxel encoder and decoder as well as a mesh decoder to deform a prototype mesh. An additional centerline coverage loss facilitates the reconstruction of the branching structure. Furthermore, vertex classification allows for the definition of in- and outlets. Our model was trained with 48 human cases and tested on 10 human cases annotated by two observers. The differences in the anatomical parameters inferred from the automatic surface generation correspond to the differences between the observers’ annotations. The suitability of the generated mesh geometries for numerical flow simulations is demonstrated.
The utilization of numerical methods, such as computational fluid dynamics (CFD), has been widely established for modeling patient-specific hemodynamics based on medical imaging data. Hemodynamics assessment plays a crucial role in treatment decisions for the coarctation of the aorta (CoA), a congenital heart disease, with the pressure drop (PD) being a crucial biomarker for CoA treatment decisions. However, implementing CFD methods in the clinical environment remains challenging due to their computational cost and the requirement for expert knowledge. This study proposes a deep learning approach to mitigate the computational need and produce fast results. Building upon a previous proof-of-concept study, we compared the effects of two different artificial neural network (ANN) architectures trained on data with different dimensionalities, both capable of predicting hemodynamic parameters in CoA patients: a one-dimensional bidirectional recurrent neural network (1D BRNN) and a three-dimensional convolutional neural network (3D CNN). The performance was evaluated by median point-wise root mean square error (RMSE) for pressures along the centerline in 18 test cases, which were not included in a training cohort. We found that the 3D CNN (median RMSE of 3.23 mmHg) outperforms the 1D BRNN (median RMSE of 4.25 mmHg). In contrast, the 1D BRNN is more precise in PD prediction, with a lower standard deviation of the error (±7.03 mmHg) compared to the 3D CNN (±8.91 mmHg). The differences between both ANNs are not statistically significant, suggesting that compressing the 3D aorta hemodynamics into a 1D centerline representation does not result in the loss of valuable information when training ANN models. Additionally, we evaluated the utility of the synthetic geometries of the aortas with CoA generated by using a statistical shape model (SSM), as well as the impact of aortic arch geometry (gothic arch shape) on the model’s training. The results show that incorporating a synthetic cohort obtained through the SSM of the clinical cohort does not significantly increase the model’s accuracy, indicating that the synthetic cohort generation might be oversimplified. Furthermore, our study reveals that selecting training cases based on aortic arch shape (gothic versus non-gothic) does not improve ANN performance for test cases sharing the same shape.
To facilitate pre-clinical animal and in-silico clinical trials for implantable pulmonary artery pressure sensors, understanding the respective species pulmonary arteries (PA) anatomy is important. Thus, morphological parameters describing PA of pigs and sheep, which are common animal models, were compared with humans. Retrospective computed tomography data of 41 domestic pigs (82.6 ± 18.8 kg), 14 sheep (49.1 ± 6.9 kg), and 49 patients (76.8 ± 18.2 kg) were used for reconstruction of the subject-specific PA anatomy. 3D surface geometries including main, left, and right PA as well as LPA and RPA side branches were manually reconstructed. Then, specific geometric parameters (length, diameters, taper, bifurcation angle, curvature, and cross-section enlargement) affecting device implantation and post-interventional device effect and efficacy were automatically calculated. For both animal models, significant differences to the human anatomy for most geometric parameters were found, even though the respective parameters’ distributions also featured relevant overlap. Out of the two animal models, sheep seem to be better suitable for a preclinical study when considering only PA morphology. Reconstructed geometries are provided as open data for future studies. These findings support planning of preclinical studies and will help to evaluate the results of animal trials.
Background: Several congenital heart defects result in the need for univentricular palliation, as no biventricular repair can be achieved either by intervention or surgery. In those patients, the superior and inferior vena cava are connected to the pulmonary artery via staged surgeries, facilitating the so-called total cavopulmonary connection (TCPC).
Background: Formation of pulmonary arteriovenous malformations (PAVM) in Fontan-palliated patients is hypothesized to be caused or at least affected by the distribution of hepatic blood (HFD) toward the left and right pulmonary artery. In patients with PAVM and uneven HFD, surgical or interventional treatment facilitating an even HFD is a promising approach to achieve remodeling of PAVM. However, while the pre-interventional hemodynamics can be assessed via angiography or velocity encoded MRI, prediction of the post-intervention hemodynamics is difficult due to the complex and heterogeneous anatomy of Fontan-palliated patients. Here, computer-based approaches might allow outcome prediction of different treatment strategies for a given patient.
In silico trials are a promising way to increase the efficiency of the development, and the time to market of cardiovascular implantable devices. The development of transcatheter aortic valve implantation (TAVI) devices, could benefit from in silico trials to overcome frequently occurring complications such as paravalvular leakage and conduction problems. To be able to perform in silico TAVI trials virtual cohorts of TAVI patients are required. In a virtual cohort, individual patients are represented by computer models that usually require patient-specific aortic valve geometries. This study aimed to develop a virtual cohort generator that generates anatomically plausible, synthetic aortic valve stenosis geometries for in silico TAVI trials and allows for the selection of specific anatomical features that influence the occurrence of complications. To build the generator, a combination of non-parametrical statistical shape modeling and sampling from a copula distribution was used. The developed virtual cohort generator successfully generated synthetic aortic valve stenosis geometries that are comparable with a real cohort, and therefore, are considered as being anatomically plausible. Furthermore, we were able to select specific anatomical features with a sensitivity of around 90%. The virtual cohort generator has the potential to be used by TAVI manufacturers to test their devices. Future work will involve including calcifications to the synthetic geometries, and applying high-fidelity fluid-structure-interaction models to perform in silico trials.
Numerical simulations of pulsatile blood flow in an aortic coarctation require the use of turbulence modeling. This paper considers three models from the class of large eddy simulation (LES) models (Smagorinsky, Vreman, σ -model) and one model from the class of variational multiscale models (residual-based) within a finite element framework. The influence of these models on the estimation of clinically relevant biomarkers used to assess the degree of severity of the pathological condition (pressure difference, secondary flow degree, normalized flow displacement, wall shear stress) is investigated in detail. The simulations show that most methods are consistent in terms of severity indicators such as pressure difference and stenotic velocity. Moreover, using second-order velocity finite elements, different turbulence models might lead to considerably different results concerning other clinically relevant quantities such as wall shear stresses. These differences may be attributed to differences in numerical dissipation introduced by the turbulence models.
Objective. This study assesses age-related differences of thoracic aorta blood flow profiles and provides age- and sex-specific reference values using 4D flow cardiovascular magnetic resonance (CMR) data.Approach. 126 volunteers (age 20-80 years, female 51%) underwent 4D flow CMR and 12 perpendicular analysis planes in the thoracic aorta were specified. For these planes the following parameters were evaluated: body surface area-adjusted aortic area (A'), normalized flow displacement (NFD), the degree of wall parallelism (WPD), the minimal relative cross-sectional area through which 80% of the volume flow passes (A80) and the angle between flow direction and centerline (α).Main results. Age-related differences in blood flow parameters were seen in the ascending aorta with higher values for NFD and angle and lower values for WPD and A80 in older subjects. All parameters describing blood flow patterns correlated with the cross-sectional area in the ascending aorta. No relevant sex-differences regarding blood flow profiles were found.Significance. These age- and sex-specific reference values for quantitative parameters describing blood flow within the aorta might help to study the clinical relevance of flow profiles in the future.
To assess whether in-silico models can be used to predict the risk of thrombus formation in pulmonary artery pressure sensors (PAPS), a chronic animal study using pigs was conducted. Computed tomography (CT) data was acquired before and immediately after implantation, as well as one and three months after the implantation. Devices were implanted into 10 pigs, each one in the left and right pulmonary artery (PA), to reduce the required number of animal experiments. The implantation procedure aimed at facilitating optimal and non-optimal positioning of the devices to increase chances of thrombus formation. Eight devices were positioned non-optimally. Three devices were positioned in the main PA instead of the left and right PA. Pre-interventional PA geometries were reconstructed from the respective CT images, and the devices were virtually implanted at the exact sites and orientations indicated by the follow-up CT after one month. Transient intra-arterial hemodynamics were calculated using computational fluid dynamics. Volume flow rates were modelled specifically matching the animals body weights. Wall shear stresses (WSS) and oscillatory shear indices (OSI) before and after device implantation were compared. Simulations revealed no relevant changes in any investigated hemodynamic parameters due to device implantation. Even in cases, where devices were implanted in a non-optimal manner, no marked differences in hemodynamic parameters compared to devices implanted in an optimal position were found. Before implantation time and surface-averaged WSS was 2.35±0.47 Pa, whereas OSI was 0.08±0.17, respectively. Areas affected by low WSS magnitudes were 2.5±2.7 cm2, whereas the areas affected by high OSI were 18.1±6.3 cm2. After device implantation, WSS and OSI were 2.45±0.49 Pa and 0.08±0.16, respectively. Surface areas affected by low WSS and high OSI were 2.9±2.7 cm2, and 18.4±6.1 cm2, respectively. This in-silico study indicates that no clinically relevant differences in intra-arterial hemodynamics are occurring after device implantation, even at non-optimal positioning of the sensor. Simultaneously, no embolic events were observed, suggesting that the risk for thrombus formation after device implantation is low and independent of the sensor position.
Objectives Assessing the risk associated with unruptured intracranial aneurysms (IAs) is essential in clinical decision making. Several geometric risk parameters have been proposed for this purpose. However, performance of these parameters has been inconsistent. This study evaluates the performance and robustness of geometric risk parameters on two datasets and compare it to the uncertainty inherent in assessing these parameters and quantifies interparameter correlations. Methods Two datasets containing 244 ruptured and unruptured IA geometries from 178 patients were retrospectively analysed. IAs were stratified by anatomical region, based on the PHASES score locations. 37 geometric risk parameters representing four groups (size, neck, non-dimensional, and curvature parameters) were assessed. Analysis included standardised absolute group differences (SADs) between ruptured and unruptured IAs, ratios of SAD to median relative uncertainty (MRU) associated with the parameters, and interparameter correlation. Results The ratio of SAD to MRU was lower for higher dimensional size parameters (ie, areas and volumes) than for one-dimensional size parameters. Non-dimensional size parameters performed comparatively well with regard to SAD and MRU. SAD was higher in the posterior anatomical region. Correlation of parameters was strongest within parameter (sub)groups and between size and curvature parameters, while anatomical region did not strongly affect correlation patterns. Conclusion Non-dimensional parameters and few parameters from other groups were comparatively robust, suggesting that they might generalise better to other datasets. The data on discriminative performance and interparameter correlations presented in this study may aid in developing and choosing robust geometric parameters for use in rupture risk models.