Neutron imaging is a non-destructive probe that can spatially resolve bulk materials’ internal features/structures. Neutron imaging spatial resolution is driven by detector technology, i.e., pixel size, and is currently on the order of 10–20 µm. This limitation can be alleviated by the use of neutron grating interferometry – an advanced neutron imaging technique – that enables simultaneous access to three contrast mechanisms: attenuation, differential phase, and small-angle neutron scattering. Recently, a Talbot-Lau neutron grating interferometry has been implemented at the Multimodal Advanced Radiography Station at the High Flux Isotope Reactor. In this work, the design, setup and performance of the grating apparatus are presented.
The layered structure of aluminum 6061 cross-sections was studied with several neutron imaging methods: transmission, grating interferometry (dark field), and Bragg-edge imaging. The multilayered samples were prepared by additive friction-stir deposition (AFSD) of aluminum 6061 with 2.54 mm print layer thickness. The AFSD aluminum printing was done in air; no evidence of aluminum hydroxide impurities was found in the neutron transmission images. The neutron dark-field data, however, showed a distinct layering structure that was affected by post-build annealing. These measurements used Talbot-Lau interferometry at a cold-neutron beamline without a monochromator and fitted, in favorable cases, to a single scattering model. Anisotropic scattering in the 6061 build plate was noted and measured. The neutron Bragg-Edge images showed crystal grain alignment in patterns correlated with the AFSD tool path.
X-ray interferometry is an emerging imaging modality with a wide variety of potential clinical applications, including lung imaging. A grating interferometer uses a diffraction grating to produce a periodic interference pattern and measures how a patient or sample perturbs the pattern, producing three unique images that highlight X-ray absorption, refraction, and small angle scattering, known as the attenuation, differential-phase, and dark-field images, respectively. Inaccuracies in grating position and multi-harmonic fringes produce Moiré artifacts when assuming the fringe pattern is perfectly sinusoidal and the phase steps are evenly spaced. We have developed an image recovery algorithm that estimates the true phase stepping positions using multiple harmonics and total variation regularization, removing the Moiré artifacts present in the attenuation, differential-phase, and dark-field images. We demonstrate the algorithm's utility for the Talbot-Lau and Modulated Phase Grating Interferometers by imaging multiple samples, including PMMA microspheres and a euthanized mouse.
X-ray interferometry is an emerging imaging modality with a wide variety of potential clinical applications, including lung and breast imaging, as well as in non-destructive testing, such as additive manufacturing and porosimetry. A grating interferometer uses a diffraction grating to produce a periodic interference pattern and measures how a patient or sample perturbs the pattern, producing three unique images that highlight X-ray absorption, refraction, and small angle scattering, known as the transmission, differential-phase, and dark-field images, respectively. Image artifacts that are unique to X-ray interferometry are introduced when assuming the fringe pattern is perfectly sinusoidal and the phase steps are evenly spaced. Inaccuracies in grating position, coupled with multi-harmonic fringes, lead to remnant oscillations and phase wraparound artifacts. We have developed an image recovery algorithm that uses additional harmonics, direct relative phase fitting, and phase step corrections to prevent them. The direct relative phase fitting removes the phase wraparound artifact. Correcting the phase step positions and introducing the additional harmonic removes the grating remnant artifact present in the transmission, differential-phase, and dark-field images. By modifying existing algorithms, the fit to the fringe pattern is greatly improved and artifacts are minimized, as we demonstrate with the imaging of several samples, including PMMA microspheres, ex vivo formalin fixed mouse lungs, and porous alumina.
This study describes procedures for embedding digital information into additively manufactured components as well as procedures for readout and tensile testing. Embedded digital codes were printed inside ASTM E8/E8M dumbbells using Direct Metal Laser Melting (DMLS) with an EOS M290 printer. The codes were configured as either ellipsoids or prolate spheroids in patterns given by the Cantor dust fractal. Tensile testing was performed on 15 dumbbells, 7 with digital codes in the gauge volume and 8 with codes in the dumbbell tail. Results showed that the dumbbells met the ultimate tensile strength specification for the EOS AlF357 powder. X-ray imaging, both conventional and interferometry, was explored to detect the digital information. X-ray tomography showed measured ellipsoid volumes slightly larger than as-designed ellipsoid volumes, even when partially filled with loose powder. X-ray interferometry showed increased void detectability, one advantage of loose powder. These results suggest a standard selective laser sintering printer with typical metal powders could reasonably expect to print 100 bits of embedded digital information in a gauge volume 6 mm in diameter as 300 $$\upmu$$ m voids while still maintaining tensile specifications.
X-ray grating interferometry allows for the simultaneous acquisition of attenuation, differential-phase contrast, and dark-field images, resulting from X-ray attenuation, refraction, and small-angle scattering, respectively. The modulated phase grating (MPG) interferometer is a recently developed grating interferometry system capable of generating a directly resolvable interference pattern using a relatively large period grating envelope function that is sampled at a pitch that allows for X-ray spatial coherence using a microfocus X-ray source or by use of a source G0 grating that follows the Lau condition. We present the theory of the MPG inter-ferometry system for a 2-dimensional staggered grating, derived using Fourier optics, and we compare the theoretical predictions with experiments we have performed with a microfocus X-ray system at Pennington Biomedical Research Center, LSU. The theoretical and experimental fringe visibility is evaluated as a function of grating-to-detector distance. Quantitative experiments are performed with porous carbon and alumina samples, and qualitative analysis of attenuation and dark-field images of a dried anchovy are shown.
Views Icon Views Article contents Figures & tables Video Audio Supplementary Data Peer Review Share Icon Share Twitter Facebook Reddit LinkedIn Tools Icon Tools Reprints and Permissions Cite Icon Cite Search Site Citation I. Hidrovo, J. Dey, H. Meyer, D. S. Hussey, N. N. Klimov, L. G. Butler, K. Ham, W. Newhauser; Erratum: "Neutron interferometry using a single modulated phase grating" [Rev. Sci. Instrum. 94, 045110 (2023)]. Rev. Sci. Instrum. 1 April 2024; 95 (4): 049903. https://doi.org/10.1063/5.0206178 Download citation file: Ris (Zotero) Reference Manager EasyBib Bookends Mendeley Papers EndNote RefWorks BibTex toolbar search Search Dropdown Menu toolbar search search input Search input auto suggest filter your search All ContentAIP Publishing PortfolioReview of Scientific Instruments Search Advanced Search |Citation Search
X-ray grating interferometry allows for the simultaneous acquisition of attenuation, differential-phase contrast, and dark-field images, resulting from X-ray attenuation, refraction, and small-angle scattering, respectively. The modulated phase grating (MPG) interferometer is a recently developed grating interferometry system capable of generating a directly resolvable interference pattern using a relatively large period grating envelope function that is sampled at a pitch that is small enough that X-ray spatial coherence can be achieved by using a microfocus X-ray source or G0 grating. We present the theory of the MPG interferometry system for a 2-dimensional staggered grating, derived using Fourier optics, and we compare the theoretical predictions with experiments we have performed with a microfocus X-ray system at Pennington Biomedical Research Center, LSU. The theoretical and experimental fringe visibility is evaluated as a function of grating-to-detector distance. Additionally, quantitative experiments are performed with porous carbon and alumina compounds, and the mean normalized dark-field signal is compared with independent porosimetry measurements. Qualitative analysis of attenuation and dark-field images of a dried anchovy are shown.
The interrogation of materials with X-rays or neutrons to determine structure, energetics, and dynamics is fundamental to advancing physical and chemical materials science and enabling innovative material technologies. A persistent challenge in materials development is that progress depends on understanding structure and dynamics across multiple length and time scales in increasingly complex, multicomponent systems featuring interfaces, heterogeneity, and hierarchical organization. Despite rapidly growing demands on materials characterization, current experimental approaches are almost exclusively based on isolated X-ray or neutron scattering and spectroscopy, reflecting a paradigm largely unchanged for decades. To assess the scientific need for a new experimental paradigm, a 3-day workshop sponsored by the U.S. National Science Foundation (NSF) was held at the SpringHill Suites, San Jose, California, from June 2 to 4, 2022. The workshop brought together 70 national and international experts who critically evaluated opportunities enabled by concurrent neutron and X-ray (NeX) scattering, spectroscopy, and imaging experiments. The participants reached a clear consensus that establishing NeX capabilities is crucial for advancing the science of complex materials in the United States. This report illustrates the scientific drivers for NeX experiments through representative examples spanning biomaterials, energy materials, soft matter, nanomaterials, quantum materials, geoscience, and applied materials research. The complementarity of neutrons and X-rays is essential for robust model development and refinement, particularly in multiphase and multicomponent systems. While joint refinement of data from separate experiments is valuable, concurrent measurements uniquely eliminate uncertainties arising from sample evolution, environmental drift, and irreproducibility associated with experiments performed at different locations and times. Realizing NeX capabilities will require the development of new instrumentation, data analysis frameworks, and robust sample environments compatible with both neutron and X-ray probes. Addressing these challenges will enable unambiguous interpretation of complex materials behavior and open new frontiers in materials research.
We report progress towards development of a cyber-physical trust anchor for additive manufacturing systems. The additive manufacturing commercial sector needs cyber-physical trust anchors to establish a secure supply chain, to detect counterfeiting and to ensure part provenance. However, the underlying technology of cyber-physical trust anchors requires optimization and spans several sectors ranging from mathematics, additive manufacturing, materials science, nondestructive evaluation, to cyber science. The fast and effective deployment of cyber-physical trust anchors requires an educational component. This project present a novel method for authenticating additively manufactured parts. Features are extracted using advanced X-ray imaging, transformed into unique identifiers, and bound with security features for cloud-based blockchain authentication. A plan for the low-cost and safe incorporation of cyber-physical trust anchor research in education is included. The anticipated outcome is an optimized trust anchor prototype and educational product suitable for interdisciplinary research and coursework to develop the workforce needed for cyber-secured physical supply chainsd.
Solid-state Friction Stir Additive Manufacturing has recently gained attention as a result of its capacity to fabricate large-scale parts while preserving the mechanical properties of the feedstock material. However, the correlation between the quality of layer-by-layer bonding of the deposited metal and processing parameters has remained unknown. Neutron imaging techniques, with 90% total transmission per cm, are employed for Al6061 parts fabricated by MELD® Technology as a non-destructive evaluation approach for the first time to investigate the layer-by-layer structure of a stadium-shaped ingot in different sections. The post-processed results show the fabricated parts with an optimized set of processing parameters are void-free. However, the hydrocarbon-based feedstock lubricant segregates between the layers, which consequently may lead to non-uniform weaker mechanical properties along the build direction and stimulate crack initiation during mechanical loading. The tensile test results show 14% lower strain-to-failure values in alleged contaminated areas in transmission imaging results. Additionally, layer bonding is significantly impacted by hot-on-hot and hot-on-cold layer deposition schemes, especially for larger layer thicknesses.
Neutron grating interferometry provides information on phase and small-angle scatter in addition to attenuation. Previously, phase grating moiré interferometers (PGMI) with two or three phase gratings have been developed. These phase-grating systems use the moiré far-field technique to avoid the need for high-aspect absorption gratings used in Talbot-Lau interferometers (TLI) that reduce the neutron flux reaching the detector. We first demonstrate, through theory and simulations, a novel phase grating interferometer system for cold neutrons that requires a single modulated phase grating (MPG) for phase-contrast imaging, as opposed to the two or three phase gratings in previously employed PGMI systems. The theory shows the dual modulation of MPG with a large period and a smaller carrier pitch P, resulting in large fringes at the detector. The theory was compared to the full Sommerfeld-Rayleigh diffraction integral simulator. Then, we proceeded to compare the MPG system to experiments in the literature that use a two-phase-grating-based PGMI with best-case visibility of around 39%. The simulations of the MPG system show improved visibility in comparison to that of the two-phase-grating-based PGMI. An MPG with a modulation period of 300 µm, the pitch of 2 µm, and grating heights with a phase modulation of (π,0, illuminated by a monochromatic beam produces visibility of 94.2% with a comparable source-to-detector distance (SDD) as the two-phase-grating-based PGMI. Phase sensitivity, another important performance metric of the grating interferometer, was compared to values available in the literature, viz. the conventional TLI with the phase sensitivity of 4.5 × 103 for an SDD of 3.5 m and a beam wavelength of 0.44 nm. For a range of modulation periods, the MPG system provides comparable or greater theoretical maximum phase sensitivity of 4.1 × 103 to 10.0 × 103 for SDDs of up to 3.5 m. This proposed MPG system appears capable of providing high-performance PGMI that obviates the need for the alignment of two phase gratings.
We have previously shown in simulations that X-ray Interferometry using Modulated Phase Gratings can create an interference pattern in clinical detectors from which attenuation, differential phase, and dark-field contrast images can be formed. This interferometric technique is advantageous since it eliminates the need to use an absorption grating as compared to Talbot-Lau grating systems, providing better dose-efficiency. In this work we experimentally evaluated this modulated phase grating system using initial test gratings obtained from Microworks GmbH, Germany. Experiments with the MPG gratings were conducted at the monochromatic 8 keV beamline at the LSU Center for Advanced Microstructures and Devices (CAMD). After analyzing our fringe pattern and eliminating the effect of source grating (G0), we observed stable fringe patterns for our MPG system at different source grating (G0) to MPG distances. The fringe pattern results from these experiments that indicate the feasibility and potential of an X-ray MPG system that could be functional with only a single-phase grating (and source grating) as opposed to a standard interferometry system that additionally requires an absorption grating near the detector.
We survey several neutron imaging and diffraction methods for non-destructive testing and evaluation of intact, commercial lithium-ion batteries. Specifically, far-field interferometry was explored as an option to probe a wide range of autocorrelation lengths within the batteries via neutron imaging. The dark-field interferometry images change remarkably from fresh to worn batteries, and from charged to discharged batteries. When attempting to search for visual evidence of battery degradation, neutron Talbot-Lau grating interferometry exposed battery layering and particle scattering through dark-field imaging. Bragg edge imaging also reveals battery wear and state of charge. Neutron diffraction observed chemical changes between fresh and worn, charged and discharged batteries. However, the utility of these methods, for commercial batteries, is dependent upon battery size and shape, with 19 to 43 mAh prismatic batteries proving most convenient for these experimental methods. This study reports some of the first spatially resolved, small angle scattering (dark-field) images showing battery degradation.
Purpose: We investigate an analyzer-less x-ray interferometer with a spatially modulated phase grating (MPG) that can deliver three modalities (attenuation image, phase image, and scatter images) in breast computed tomography (BCT). The system can provide three x-ray modalities while preserving the dose to the object and can achieve attenuation image sensitivity similar to that of a standard absorption-only BCT. The MPG system works with a source, a source-grating, a single phase grating, and a detector. No analyzer is necessary. Thus, there is an approximately 2x improvement in fluence at the detector for our system compared with the same source-detector distance Talbot-Lau x-ray interferometry (TLXI) because the TLXI has an analyzer after the object, which is not required for the MPG. Approach: We investigate the MPG BCT system in simulations and find a clinically feasible system geometry. First, the mechanism of MPG interferometry is conceptually shown via Sommerfeld-Rayleigh diffraction integral simulations. Next, we investigate source coherence requirements, fringe visibility, and phase sensitivity dependence on different system parameters and find clinically feasible system geometry. Results: The phase sensitivity of MPG interferometry is proportional to object-detector distance and inversely proportional to a period of broad fringes at the detector, which is determined by the grating spatial modulation period. In our simulations, the MPG interferometry can achieve about 27% fringe visibility with clinically realistic BCT geometry of a total source-detector distance of 950 mm and source-object distance of 500 mm. Conclusions: We simulated a promising analyzer-less x-ray interferometer, with a spatially sinusoidal MPG. Our system is expected to deliver the attenuation, phase and scatter image in a single acquisition without dose or fluence detriment, compared with conventional BCT. (C) The Authors. Published by SPIE under a Creative Commons Attribution 4.0 Unported License.
X-ray interferometry provides a dark-field image, essentially a small-angle X-ray scattering image, of the voids and print defects in an additively manufactured polymer object. The interferometers used were tuned to scattering length 2-5 mu m and configured to measure scattering along both vertical and horizontal directions. The samples studied included Stanford Bunnies, fabricated from acrylonitrile butadiene styrene (ABS) and polylactic acid (PLA), and a quadratic test object fabricated from PLA. The dark-field projection images show orientation dependent X-ray scattering which is due to anisotropic voids and gaps at the filament-to-filament interface in these fused deposition modeling additive manufacturing objects. SEM corroborates the existence of gaps between filaments. The absorption and dark-field volumes are used to correlate printhead trajectory with print defect density. The absorption volume is used to generate perimeter points slice-by-slice, and from these points, the 2D curvature is calculated. There is a slight increase in X-ray scattering, hence print defect density, at regions with high curvature. Two X-ray interferometry techniques were used: stepped-grating and single-shot. As currently developed, stepped-grating has the larger field-of-view examination of an entire test object whilst single-shot has the potential for real-time, in situ measurement of the printing process within 1 mm of the printhead.
Phase contrast X-ray not only provides attenuation of tissue, but two other modalities (phase and scatter) in same scan. Scatter (dark-field) images provided by the technology are far more sensitive to structural and density changes of tissue such as lungs and can identify lung disease where conventional X-ray fails. Other areas poised to benefit greatly are mammography and bone joint imaging (eg. imaging arthritis). Of the various interferometer techniques, the two at the forefront are: Far-field Interferometry (FFI) (Miao et al, Nat. Phy. 2015) and Talbot-Lau interferometry (TLI) (Momose JJAP 2005, Pfeiffer Nature 2006). While the TLI has already made clinical strides, the newer FFI has advantage of not requiring an absorption grating ("analyzer") and provides few-fold higher scatter sensitivity. In this work, a novel 2D single phase-grating (not requiring the analyzer), near-field phase contrast system was simulated using Sommerfeld-Rayleigh diffraction integrals. We observed 2D fringe patterns (pitch 800nm) at 50mm distance from the grating. Such a pattern period of 0.05mm, can be imaged by the LSU-interferometers with CT detector resolution (0.015mm) or Philips mammography detector resolution (0.05mm) making this practical system. Our design has a few advantages over Miao et al FFI system. We accomplish in one X-ray grating the functionality that requires 2-3 phase-grating in their design. And our design can also provide a compact system (source to detector distance < 1m) with control over the fringe pattern by fine tuning grating structure. We retain all the benefits of far-field systems - of not requiring analyzer and high scatter sensitivity over Talbot-Lau interferometers.
A novel single-phase-grating Phase contrast system was simulated using Sommerfield-Rayleigh diffraction integrals. We accomplish in one X-ray optic the functionality that requires 2-3 optics in Miao et al Nature Physics 2015. We retain all their benefits of not requiring the absorption grating (analyzer) in Talbot-Lau interferometers. This will reduce the dose-requirement (approximately by a factor of two). We observed interference pattern (pitch 0.2mm) with grating to detector distance of 50mm for parallel beam source. The interference pattern can be tuned to different applications depending on detector resolution. Our eventual goal is to achieve compact interferometry of the design lengths required for a clinical mammogram system.
In this work, fire inhibition performance of four flame retardant formulations of brominated flame retardant (BFR: GreenArmor (R)), antimony(III) oxide (Sb2O3) and high impact polystyrene (HIPS) is reported. The standard Underwriters Laboratory (UL 94) vertical burn test was applied for assessing the flame retardancy of a variety of polymer blends. A formulation having 13.3 wt% GreenArmor (R), 4 wt% Sb2O3 and 82.7 wt% HIPS, named sample D, successfully passed the flame test and was rated V-0. The other formulations with deficient composition exhibited low flame retardancy, as expected. The X-ray grating interferometry method is introduced for probing the 3D internal structures across the burnt UL 94 flame retarded polymer blend formulations to present the detailed mechanisms of flame retardancy. The X-ray images revealed several features for the formulation (sample D) that passed the UL 94 test: heat-induced dissolution of BFR and Sb2O3 residual particles, formation of gas bubbles inside the burnt polymer test bar, deflation of gas bubbles in a char layer through a microcrack, and thick char layer development, defined by the Br and Sb concentration profile to a depth of 100-220 mu m. Also, the X-ray images show clear differences between formulations that pass and fail the UL 94 test. X-ray grating interferometry imaging is proposed as a novel technique for assessment of new generation flame retardants. (C) 2017 Elsevier Ltd. All rights reserved.