To develop long-term high quality communication between brain and computer, a key issue is how to reduce the adverse foreign body responses. Here, the impact of probe flexibility and gelatine embedding on long-term (6w) tissue responses, was analyzed. Probes of same polymer material, size and shape, flexible mainly in one direction, were implanted in rat cerebral cortex (nimplants = 3 x 8) in two orientations with respect to the major movement direction of the brain relative to the skull: parallel to (flex mode) or transverse to (rigid mode). Flex mode implants were either embedded in gelatin or non-embedded. Neurons, activated microglia and astrocytes were visualized using immunohistochemistry. The astrocytic reactivity, but not microglial response, was significantly lower to probes implanted in flex mode as compared to rigid mode. The microglial response, but not astrocytic reactivity, was significantly smaller to gelatin embedded probes (flex mode) than non-embedded. Interestingly, the neuronal density was preserved in the inner zone surrounding gelatin embedded probes. This contrasts to the common reports of reduced neuronal density close to implanted probes. In conclusion, sheer stress appears to be an important factor for astrocytic reactivity to implanted probes. Moreover, gelatin embedding can improve the neuronal density and reduce the microglial response close to the probe.
We have developed a multichannel electrode array—termed \(\mu \) -foil—that comprises ultrathin and flexible electrodes protruding from a thin foil at fixed distances. In addition to allowing some of the active sites to reach less compromised tissue, the barb-like protrusions that also serves the purpose of anchoring the electrode array into the tissue. This paper is an early evaluation of technical aspects and performance of this electrode array in acute in vitro / in vivo experiments. The interface impedance was reduced by up to two decades by electroplating the active sites with platinum black. The platinum black also allowed for a reduced phase lag for higher frequency components. The distance between the protrusions of the electrode array was tailored to match the architecture of the rat cerebral cortex. In vivo acute measurements confirmed a high signal-to-noise ratio for the neural recordings, and no significant crosstalk between recording channels.
We have developed a multichannel electrode array-termed μ-foil-that comprises ultrathin and flexible electrodes protruding from a thin foil at fixed distances. In addition to allowing some of the active sites to reach less compromised tissue, the barb-like protrusions that also serves the purpose of anchoring the electrode array into the tissue. This paper is an early evaluation of technical aspects and performance of this electrode array in acute in vitro/in vivo experiments. The interface impedance was reduced by up to two decades by electroplating the active sites with platinum black. The platinum black also allowed for a reduced phase lag for higher frequency components. The distance between the protrusions of the electrode array was tailored to match the architecture of the rat cerebral cortex. In vivo acute measurements confirmed a high signal-to-noise ratio for the neural recordings, and no significant crosstalk between recording channels.
A polymer foil based array with 9 gold electrodes for chronic electrophysiological recordings in the CNS has been developed. A polymer, SU-8, is pattered using photolithography techniques used every day in micro fabrication. This is beneficial if the electrode would be manufactured on a large scale basis. The technique makes it easy to adapt the array to best fit the structure of interest at the time, in this study the rat cerebellar cortex. The use of SU-8 as the base of the array makes the array very flexible, hence lets it stay close to the same cells following the movement of the brain. The electrodes can then be modified with platinum black to lower the impedance of the electrode up to one order of magnitude, making us able to create smaller electrodes but keeping the low impedance necessary to get a get the signal to noise ratio required. Platinum black modified arrays were also implanted chronically and showed excellent signal recording capabilities in rat cerebellum.
A new type of chip based microelectrode for acute electrophysiological recordings in the CNS has been developed. It's designed to be adaptable to a multitude of specific neuronal environments, in this study the cerebellar cortex of rat and cat. Photolithographically patternened SU-8 is used to yield flexible and biocompatible penetrating shanks with gold leads. Electrodes with an impedance of about 300 kOmega at 1kHz have excellent signal to noise ratio in acute recordings in cat cerebellum.