OBJECTIVE:Flexible neural probes are hypothesized to reduce the chronic foreign body response (FBR) mainly by reducing the strain-stress caused by an interplay between the tethered probe and the brain's micromotion. However, a large discrepancy of Young's modulus still exists (3-6 orders of magnitude) between the flexible probes and the brain tissue. This raises the question of whether we need to bridge this gap; would increasing the probe flexibility proportionally reduce the FBR? APPROACH:Using novel off-stoichiometry thiol-enes-epoxy (OSTE+) polymer probes developed in our previous work, we quantitatively evaluated the FBR to four types of probes with different softness: silicon (~150 GPa), polyimide (1.5 GPa), OSTE+Hard (300 MPa), and OSTE+Soft (6 MPa). MAIN RESULTS:We observed a significant reduction in the fluorescence intensity of biomarkers for activated microglia/macrophages and blood-brain barrier (BBB) leakiness around the three soft polymer probes compared to the silicon probe, both at 4 weeks and 8 weeks post-implantation. However, we did not observe any consistent differences in the biomarkers among the polymer probes. SIGNIFICANCE:The results suggest that the mechanical compliance of neural probes can mediate the degree of FBR, but its impact diminishes after a hypothetical threshold level. This infers that resolving the mechanical mismatch alone has a limited effect on improving the lifetime of neural implants.
The flexibility of implantable neural probes has increased during the last 10 years, starting with stiff materials such as silicone to more flexible materials like polyimide. We have developed a novel polymer based on Off-Stoichiometry Thiol-Enes + Epoxy (OSTE+, consisting of a thiol, two allyls, an epoxy resin and two initiators), which is up to 100 times more flexible than polyimide. Since a flexible neural probe should be more biocompatible than a stiff probe, an OSTE+ probe should be more biocompatible than one composed of a more rigid material. We have investigated the toxicity of OSTE+ as well as of OSTE+ that had been incubated in water for a week (OSTE+H2O) using MTT assays with mouse L929 fibroblasts. We found that OSTE+ showed cytotoxicity, but OSTE+H2O did not. Extracts were analyzed using LC-MS and GC-MS in order to identify leaked chemicals.
To develop long-term high quality communication between brain and computer, a key issue is how to reduce the adverse foreign body responses. Here, the impact of probe flexibility and gelatine embedding on long-term (6w) tissue responses, was analyzed. Probes of same polymer material, size and shape, flexible mainly in one direction, were implanted in rat cerebral cortex (nimplants = 3 x 8) in two orientations with respect to the major movement direction of the brain relative to the skull: parallel to (flex mode) or transverse to (rigid mode). Flex mode implants were either embedded in gelatin or non-embedded. Neurons, activated microglia and astrocytes were visualized using immunohistochemistry. The astrocytic reactivity, but not microglial response, was significantly lower to probes implanted in flex mode as compared to rigid mode. The microglial response, but not astrocytic reactivity, was significantly smaller to gelatin embedded probes (flex mode) than non-embedded. Interestingly, the neuronal density was preserved in the inner zone surrounding gelatin embedded probes. This contrasts to the common reports of reduced neuronal density close to implanted probes. In conclusion, sheer stress appears to be an important factor for astrocytic reactivity to implanted probes. Moreover, gelatin embedding can improve the neuronal density and reduce the microglial response close to the probe.
We have developed a multichannel electrode array—termed \(\mu \) -foil—that comprises ultrathin and flexible electrodes protruding from a thin foil at fixed distances. In addition to allowing some of the active sites to reach less compromised tissue, the barb-like protrusions that also serves the purpose of anchoring the electrode array into the tissue. This paper is an early evaluation of technical aspects and performance of this electrode array in acute in vitro / in vivo experiments. The interface impedance was reduced by up to two decades by electroplating the active sites with platinum black. The platinum black also allowed for a reduced phase lag for higher frequency components. The distance between the protrusions of the electrode array was tailored to match the architecture of the rat cerebral cortex. In vivo acute measurements confirmed a high signal-to-noise ratio for the neural recordings, and no significant crosstalk between recording channels.
We have developed a multichannel electrode array-termed μ-foil-that comprises ultrathin and flexible electrodes protruding from a thin foil at fixed distances. In addition to allowing some of the active sites to reach less compromised tissue, the barb-like protrusions that also serves the purpose of anchoring the electrode array into the tissue. This paper is an early evaluation of technical aspects and performance of this electrode array in acute in vitro/in vivo experiments. The interface impedance was reduced by up to two decades by electroplating the active sites with platinum black. The platinum black also allowed for a reduced phase lag for higher frequency components. The distance between the protrusions of the electrode array was tailored to match the architecture of the rat cerebral cortex. In vivo acute measurements confirmed a high signal-to-noise ratio for the neural recordings, and no significant crosstalk between recording channels.
This paper describes the fabrication and initial characterization of an ultra-thin silicon PIN detector using a new technique in silicon nanotechnology. In collaboration with the Nuclear Physics Division and the Lund Nano Lab at Lund University, we have developed and manufactured ultra thin Δ E -detectors for spectroscopic applications. The fabrication process has been carried out using a double-polished silicon substrate n-type wafer and locally thinning by means of a 10:1 solution of 25% tetramethyl ammonium hydroxide (TMAH) with Isopropyl alcohol. More than 100 detectors of different thicknesses, down to 5 μm with active areas ranging from 0.71 to 0.172 mm 2 , have been fabricated. The main design considerations of our thin detectors were a very low leakage current below 12 nA and a low full depletion voltage at a reverse bias less than 1.5 V. Finally, most of our thin detectors offer an energy resolution (FWHM) as low as 31 keV for 5.487 MeV alpha particles from a 241 Am source.
A novel polymeric material, off-stoichiometry thiol-ene-epoxy (OSTE+), has been evaluated for the fabrication of neural implants. OSTE+ is easily photo-structurable and exhibits mechanical properties suitable for stable implantation of the probe into brain tissue, while being sufficiently soft at physiological temperatures to reduce living tissue damage. The facile processing of OSTE+ allows use in applications where SU-8 or polyimide currently are the materials of choice. Uniquely, OSTE+ has a Young's modulus of 1.9 GPa at 10 °C decreasing almost two orders of magnitude to 30 MPa at 40 °C, which can be compared to the Young's modulus of 2.1 GPa for SU-8. We show a probe, with nine gold electrode sites, implanted into 0.5% agar at 40 °C using active cooling during the implantation.
We present an electrode, based on structurally controlled nanowires, as a first step towards developing a useful nanostructured device for neurophysiological measurements in vivo. The sensing part of the electrode is made of a metal film deposited on top of an array of epitaxially grown gallium phosphide nanowires. We achieved the first functional testing of the nanowire-based electrode by performing acute in vivo recordings in the rat cerebral cortex and withstanding multiple brain implantations. Due to the controllable geometry of the nanowires, this type of electrode can be used as a model system for further analysis of the functional properties of nanostructured neuronal interfaces in vivo.
We have proposed an echo localization estimator which theoretically gives infinite resolution in the axial direction in ultrasonic B-mode images during 1) echo structure tracking and 2) distance measurements of distinct echoes. The performance of the estimator was evaluated using a HDI5000 (Philips Medical Systems, Bothell, WA, USA) with a 35 mm 5-12 MHz linear array transducer. The resulting pixel size in the B-mode image was 100 m. The controlled setup consisted of a small water container lined with ultrasound absorber carpet and placed on a micrometer table, a triangulation laser (M5L/2, MEL Mikroelektronik GmbH, Eching, Germany) connected to a high-performance digital multimeter HP 34401A (Agilent Technologies, USA) and a thermometer TESTO 925 (Testo AG, Germany). In each of the three measurement series the micrometer table was moved approximately 15 m in 10-12 steps. The echo localization estimator succeeded to resolve the minute movement (<; 20 m) with high agreement with the reference method in all three series. The correlation was (R>0.998; p <;10-e38; 0.86<;k<;0.92). The standard deviation in the recorded 25 image cineloops ranged between 97 and 195 nm. Using BMode images with pixel size of 100 m as a base, our echo localization estimator can resolve micrometer movement accurately in a controlled set-up.
Culturing stem cells as free-floating aggregates in suspension facilitates large-scale production of cells in closed systems, for clinical use. To comply with GMP standards, the use of substances such as proteolytic enzymes should be avoided. Instead of enzymatic dissociation, the growing cell aggregates may be mechanically cut at passage, but available methods are not compatible with large-scale cell production and hence translation into the clinic becomes a severe bottle-neck. We have developed the Biogrid device, which consists of an array of micrometerscale knife edges, micro-fabricated in silicon, and a manifold in which the microgrid is placed across the central fluid channel. By connecting one side of the Biogrid to a syringe or a pump and the other side to the cell culture, the culture medium with suspended cell aggregates can be aspirated, forcing the aggregates through the microgrid, and ejected back to the cell culture container. Large aggregates are thereby dissociated into smaller fragments while small aggregates pass through the microgrid unaffected. As proof-of-concept, we demonstrate that the Biogrid device can be successfully used for repeated passage of human neural stem/progenitor cells cultured as so-called neurospheres, as well as for passage of suspension cultures of human embryonic stem cells. We also show that human neural stem/progenitor cells tolerate transient pressure changes far exceeding those that will occur in a fluidic system incorporating the Biogrid microgrids. Thus, by using the Biogrid device it is possible to mechanically passage large quantities of cells in suspension cultures in closed fluidic systems, without the use of proteolytic enzymes.
A polymer foil based array with 9 gold electrodes for chronic electrophysiological recordings in the CNS has been developed. A polymer, SU-8, is pattered using photolithography techniques used every day in micro fabrication. This is beneficial if the electrode would be manufactured on a large scale basis. The technique makes it easy to adapt the array to best fit the structure of interest at the time, in this study the rat cerebellar cortex. The use of SU-8 as the base of the array makes the array very flexible, hence lets it stay close to the same cells following the movement of the brain. The electrodes can then be modified with platinum black to lower the impedance of the electrode up to one order of magnitude, making us able to create smaller electrodes but keeping the low impedance necessary to get a get the signal to noise ratio required. Platinum black modified arrays were also implanted chronically and showed excellent signal recording capabilities in rat cerebellum.
The Integrated Selective Enrichment Target (ISET) is a microfluidic platform for solid-phase extraction (SPE) sample preparation and sample presentation prior to matrix-assisted laser desorption/ionization mass spectrometry (MALDI MS). The original design of the ISET consisted of an array of nanovials manufactured by wet-etching of 360 μm silicon, each having a single inlet and outlet. Here it is shown that by substituting the single hole outlet for a 3 x 3 array of outlets for each nanovial, the usefulness, flexibility and robustness of the of the ISET sample preparation platform is increased.
We compared porous silicon (pSi) with smooth Si as chip-implant surfaces in a nerve regeneration setting. Silicon chips can be used for recording neural activity and are potential nerve interface devices. A silicon chip with one smooth and one porous side inserted into a tube was used to bridge a 5 mm defect in rat sciatic nerve. Six or 12 weeks later, new nerve structures surrounded by a perineurium-like capsule had formed on each side of the chip. The number of regenerated nerve fibers did not differ on either side of the chip as shown by immunostaining for neurofilaments. However, the capsule that had formed in contact with the chip was significantly thinner on the porous side than on the smooth side. Cellular protrusions had formed on the pSi side and the regenerated nerve tissue was found to attach firmly to this surface, while the tissue was hardly attached to the smooth silicon surface. We conclude that a pSi surface, due to its large surface area, diminished inflammatory response and firm adhesion to the tissue, should be a good material for the development of new implantable electronic nerve devices.
A new type of chip based microelectrode for acute electrophysiological recordings in the CNS has been developed. It's designed to be adaptable to a multitude of specific neuronal environments, in this study the cerebellar cortex of rat and cat. Photolithographically patternened SU-8 is used to yield flexible and biocompatible penetrating shanks with gold leads. Electrodes with an impedance of about 300 kOmega at 1kHz have excellent signal to noise ratio in acute recordings in cat cerebellum.