The effects of wrapping the internal mammary artery in Gore-Tex surgical membrane on the formation of adhesions were investigated. In seven goats both internal mammary arteries were dissected free from the thoracic wall. In six goats the internal mammary arteries were wrapped in Gore-Tex surgical membrane. In the remaining animal both arteries were removed and used as controls. After 6 months the goats were reoperated and it was found that the wrapped segments of all arteries were completely free of adhesions, whereas the non-wrapped segments showed severe adhesion formation. Histologic examination could not detect differences between the wrapped arteries and the controls. One of the 12 wrapped arteries was occluded by a longer existing thrombus, which is attributed to the surgical technique and the fact that postoperatively no anticoagulation was given. The beneficial effect of the use of Gore-Tex surgical membrane on the prevention of adhesion formation is excellent and this implies that it could be used in coronary artery bypass operations, thus reducing the chance of damage to the bypass in case of reoperation.
The results of autopsy of 77 patients who died because of surgical disease of the digestive tract were compared with antemortem findings. An analysis was performed to identify missed diagnoses and incorrect therapy. Primary diagnoses had not been frequently missed, but many complications of the primary disorder or treatment had been overlooked. Many patients died because of septic conditions. Error in treatment, with an adverse impact on the course of the disease as assessed by the postmortem examination, occurred in 9 percent of the patients. The most common error had been failure to reoperate upon patients with an intra-abdominal complication.Unexpected death was significantly associated with incorrect diagnosis; failed or inadequate diagnostic methods were significantly associated with treatment failure (chi-square tests). The autopsy remains a valuable procedure in clinical operation. Selection of patients for autopsy, as indicated by decreasing autopsy rates, is not justified.
An analysis of autopsy findings in 68 patients who died with vascular surgical disorders was performed. Incorrect diagnoses and therapy were evaluated. It was found that complications of the primary disease or its treatment were frequently missed clinically (41%). Septic complications and severe hemorrhage were common in examinations of morbidity and mortality. In 13% of cases a treatment error with adverse impact on survival was detected. It is concluded that postmortem examination is a valuable tool in the final evaluation of patient care in a vascular surgical unit. A repeated plea for the autopsy is supported by this study.
An autopsy study was performed to quantify diagnostic fallibility in clinical surgery. Autopsy results in 312 surgical patients were compared with clinical findings. The primary clinical diagnosis was correct in 93 per cent of patients; complications had been correctly diagnosed in 60 per cent and error in treatment was found in 16 per cent. Error in treatment had an adverse impact on the course of disease in 11 per cent of patients. Infective complications such as abdominal sepsis and bronchopneumonia were encountered most often. Sensitivity was low for the clinical diagnosis of pulmonary embolism, bronchopneumonia, myocardial infarction and terminal haemorrhage. Statistical analysis showed that sudden unexpected death is the most obvious condition in which a high yield is expected from a post-mortem examination. Autopsy remains a valuable means of quality control in clinical surgery and could be a basis for surgical audit.
Comparison was made between the morphologic condition of the left anterior descending artery and four arterial conduits: the internal mammary, right gastroepiploic, inferior epigastric, and radial arteries, harvested from 17 patients (aged 15 to 85 years, mean 64 years) who had died of nonvascular diseases. Proximal, mid, and distal segments were examined microscopically. The internal mammary artery was elastic, but the others were muscular. In all four conduits, atherosclerosis was absent to mild, the internal elastic lamina showed only minimal defects, and the vasa vasorum were confined to the adventitia. In all cases the left anterior descending artery showed mild to severe atherosclerosis and substantial defects in the internal elastic lamina with penetration of the vasa vasorum into the media and intima. Comparison of the mean distance (+/- standard deviation) from the lumen to the outermost portion of the media for the left anterior descending artery (320 +/- 63 microns) with the four conduits gave comparable values for the internal mammary artery (350 +/- 92 microns); p = not significant) and the right gastroepiploic artery (291 +/- 109 microns; p = not significant), versus 529 +/- 52 microns; p less than 0.002) for the radial artery and 249 microns (+/- 87 microns) (p less than 0.04) for the inferior epigastric artery (Kruskal-Wallis and Mann-Whitney U tests). The relatively scanty presence of smooth muscle cells in the thin-walled media of the internal mammary artery combined with a well-formed internal elastic lamina, even at advanced age, may be an important cause for its low susceptibility to atherosclerosis and a major determinant in its superior long-term patency as a coronary artery bypass graft. This finding emphasizes the justification of continued use of the ideally matching internal mammary artery, either as in situ or free graft, in coronary artery bypass grafting. In contrast to the thick-walled radial artery, which may be relatively prone to ischemia, an acceptable long-term patency of the inferior epigastric artery and right gastroepiploic artery, if harvested as pedicled grafts, is anticipated.
A 47-year-old woman with long-standing myelofibrosis and thrombocytosis whose spleen was removed 9 days prior to death, died of a heart tamponade. Subsequent autopsy revealed the development of chylothorax and chylopericardium due to the existence of a thrombus obstructing the ostium of the left thoracic duct, as a consequence of the particular location of a central venous catheter in the left subclavian vein in the proximity of the confluence of the left thoracic duct in the afore-mentioned vein.
The edge of tissue left after ventricular aneurysmectomy requires very careful placement and tying of the sutures. The use of Teflon felt as a support appears to redistribute the pressure and thus prevent the sutures from cutting through the vulnerable tissue. In many cases, Teflon felt reinforcement is preferred to direct unsupported closure because of perioperative of immediately postoperative bleeding complications. However, the unavoidable full immobilization of the sutured area, the possible risk of foreign body infection, and the extensive adhesions and calcification in the long term compelled us to search for a better alternative, combining the convenience of both methods and limiting the risks. PDS (polydioxine) resorbable pledgets and strips, provided by Ethicon GmbH, were used as a suture support during the past 2 years for closure of 29 ventricular aneurysmectomies and four ischemic ventricular septal defects, all except one in combination with coronary bypass grafting. The PDS material was easy and efficient to apply and caused no complications during and after the operation. In one case, we had the opportunity to review the supported scar during a second operation for new coronary grafts after 18 months. The formerly feared “linear scar petrification,” usual after use of Teflon felt, was absent. The scar was free from difficult adhesions. Our initial experience suggests the further extensive use of this resorbable material as a support for various sutures at risk.
Post-mortem examination was made of 136 patients who died of ischaemic heart disease from within a few minutes to 4 days after the onset to symptoms. Acute myocardial infarction was detected by means of the histochemistry of dehydrogenases in 102 cases (75%); in 34 cases(25%) no infarction was found, but the presence of coronary obstruction together with clinical symptoms justified the diagnosis of acute coronary insufficiency. Fifty-six of the infarctions occurred within 2--3 h after the onset of ischaemia, 24 within 4--5 h, 12 within 6--24 h, and 10 within 1--4 days. The chances of recovery increased if the patients survived for 24 h. The period of 5 h after the onset of ischaemia appeared especially important; 80 of 102 patients with acute myocardial infarction died during that period. Thirty-one of 34 patients with acute coronary insufficiency and 60 of 102 patients with acute myocardial infarction died peracutely, i.e. within a few minutes to 2 h after the onset of symptoms. In the patients of the latter group the onset of symptoms must have been delayed, otherwise none of these patients could have appeared in the category of peracute death. This delay was more obvious in the patients with acute myocardial infarction localized in the area supplied by the left descending artery. The occurrence of peracute deaths could not be correlated witha particular localization of area of infarction. The causes of coronary obstructions and the role of dynamic disturbances of coronary perfusion in the pathogenesis of coronary insufficiency and myocardial infarction and discussed.
The effects of wrapping the internal mammary artery in Gore-Tex surgical membrane on the formation of adhesions were investigated. In seven goats both internal mammary arteries were dissected free from the thoracic wall. In six goats the internal mammary arteries were wrapped in Gore-Tex surgical membrane. In the remaining animal both arteries were removed and used as controls. After 6 months the goats were reoperated and it was found that the wrapped segments of all arteries were completely free of adhesions, whereas the non-wrapped segments showed severe adhesion formation. Histologic examination could not detect differences between the wrapped arteries and the controls. One of the 12 wrapped arteries was occluded by a longer existing thrombus, which is attributed to the surgical technique and the fact that postoperatively no anticoagulation was given. The beneficial effect of the use of Gore-Tex surgical membrane on the prevention of adhesion formation is excellent and this implies that it could be used in coronary artery bypass operations, thus reducing the chance of damage to the bypass in case of reoperation. (Eur J Cardio-thorac Surg (1993) 7:81-831