Summary Aim To evaluate the educational effectiveness of a clinically integrated e-learning course for teaching basic evidence-based medicine (EBM) among postgraduate medical trainees compared to a traditional lecture-based course of equivalent content. Methods We conducted a cluster randomized controlled trial to compare a clinically integrated e-learning EBM course (intervention) to a lecture-based course (control) among postgraduate trainees at foundation or internship level in seven teaching hospitals in the UK West Midlands region. Knowledge gain among participants was measured with a validated instrument using multiple choice questions. Change in knowledge was compared between groups taking into account the cluster design and adjusted for covariates at baseline using generalized estimating equations (GEE) model. Results There were seven clusters involving teaching of 237 trainees (122 in the intervention and 115 in the control group). The total number of postgraduate trainees who completed the course was 88 in the intervention group and 72 in the control group. After adjusting for baseline knowledge, there was no difference in the amount of improvement in knowledge of EBM between the two groups. The adjusted post course difference between the intervention group and the control group was only 0.1 scoring points (95% CI −1.2–1.4). Conclusion An e-learning course in EBM was as effective in improving knowledge as a standard lecture-based course. The benefits of an e-learning approach need to be considered when planning EBM curricula as it allows standardization of teaching materials and is a potential cost-effective alternative to standard lecture-based teaching.
BACKGROUND:To evaluate the educational effects of a clinically integrated e-learning course for teaching basic evidence-based medicine (EBM) among postgraduates compared to a traditional lecture-based course of equivalent content.METHODS:We conducted a cluster randomised controlled trial in the Netherlands and the UK involving postgraduate trainees in six obstetrics and gynaecology departments. Outcomes (knowledge gain and change in attitude towards EBM) were compared between the clinically integrated e-learning course (intervention) and the traditional lecture based course (control). We measured change from pre- to post-intervention scores using a validated questionnaire assessing knowledge (primary outcome) and attitudes (secondary outcome).RESULTS:There were six clusters involving teaching of 61 postgraduate trainees (28 in the intervention and 33 in the control group). The intervention group achieved slightly higher scores for knowledge gain compared to the control, but these results were not statistically significant (difference in knowledge gain: 3.5 points, 95% CI -2.7 to 9.8, p = 0.27). The attitudinal changes were similar for both groups.CONCLUSION:A clinically integrated e-learning course was at least as effective as a traditional lecture based course and was well accepted. Being less costly than traditional teaching and allowing for more independent learning through materials that can be easily updated, there is a place for incorporating e-learning into postgraduate EBM curricula that offer on-the-job training for just-in-time learning.TRIAL REGISTRATION:TRIAL REGISTRATION NUMBER:ACTRN12609000022268.
Große Studierendenzahlen und heterogene Dozierende erschweren einheitliche Kursgestaltungen und die objektive Standardisierung von Prüfungen im chirurgischen Fertigkeitstraining. Diese Arbeit zeigt die Vorteile des Einsatzes neuer Medien im „Blended-learning-Konzept“ für das Fertigkeitstraining im Studiengang Humanmedizin der Universität Basel.
BACKGROUND:We developed and evaluated the outcomes of an e-learning course for evidence based medicine (EBM) training in postgraduate medical education in different languages and settings across five European countries.METHODS:We measured changes in knowledge and attitudes with well-developed assessment tools before and after administration of the course. The course consisted of five e-learning modules covering acquisition (formulating a question and search of the literature), appraisal, application and implementation of findings from systematic reviews of therapeutic interventions, each with interactive audio-visual learning materials of 15 to 20 minutes duration. The modules were prepared in English, Spanish, German and Hungarian. The course was delivered to 101 students from different specialties in Germany (psychiatrists), Hungary (mixture of specialties), Spain (general medical practitioners), Switzerland (obstetricians-gynaecologists) and the UK (obstetricians-gynaecologists). We analysed changes in scores across modules and countries.RESULTS:On average across all countries, knowledge scores significantly improved from pre- to post-course for all five modules (p < 0.001). The improvements in scores were on average 1.87 points (14% of total score) for module 1, 1.81 points (26% of total score) for module 2, 1.9 points (11% of total score) for module 3, 1.9 points (12% of total score) for module 4 and 1.14 points (14% of total score) for module 5. In the country specific analysis, knowledge gain was not significant for module 4 in Spain, Switzerland and the UK, for module 3 in Spain and Switzerland and for module 2 in Spain. Compared to pre-course assessment, after completing the course participants felt more confident that they can assess research evidence and that the healthcare system in their country should have its own programme of research about clinical effectiveness.CONCLUSION:E-learning in EBM can be harmonised for effective teaching and learning in different languages, educational settings and clinical specialties, paving the way for development of an international e-EBM course.
Human granulocytic ehrlichiosis (HGE) is an emerging tick-borne infectious disease found in Europe, the United States, and other regions where Ixodes ticks and Lyme disease are endemic. HGE typically presents with myalgia, fever and nausea. Only a few single cases of HGE predominantly manifesting with neurological symptoms and signs have been described to date. The prevalence of this ,,neuro-ehrlichiosis" (NE) is not known and a systematic search for NE in patients with neurological deficits has not yet been performed. As both mode of transmission and clinical neurological presentations of HGE are similar to those of neuroborreliosis (NB) we analyzed 47 inpatients of a neurological tertiary care facility in South-eastern Austria in which NB was suspected but not confirmed by stringent diagnostic criteria. In five patients - two patients with radiculoneuritis, two with polyradiculoneuritis (one of which with Guillain Barre syndrome) and one with peripheral facial nerve palsy - antibodies to Ehrlichia equi related agents (HGE-agents) were detected by means of indirect immunofluorescent antibody assay and in four this was confirmed by Western blot. We suspect that in tick endemic areas of Central Europe HGE may be responsible for neurological deficits but further large scale prospective studies of seroprevalence in neurological patients are needed to make it an established differential diagnosis of NB.
The neurological manifestations of Lyme borreliosis comprise a wide range of clinical signs. However, these symptoms might have other aetiologies. Therefore detection of intrathecal production of specific antibodies is necessary to confirm the clinical assumption of neuroborreliosis (NB). In case of delayed intrathecal production of specific IgG antibodies, detection of IgM could play a role in the early diagnosis of NB. To clarify whether IgM is of diagnostic value in such cases, paired CSF serum samples from 176 patients with suspected NB admitted to the department of Neurology, Karl Franzens University, Graz, Austria, were tested. Testing was performed with the IDEA Neuroborreliosis Kit (Dako, Denmark) and Enzygnost Borreliosis (Behring, Germany) and results of both methods were compared. According to well defined criteria 63 of the 176 patients had defined NB and 113 were regarded as possible NB. Twelve out of 63 patients with defined NB had delayed intrathecal IgG production. Only one patient with delayed IgG production had an intrathecal IgM production prior to IgG. In all patients with possible NB no intrathecal production of IgM was detected. At the time of the first lumbar puncture IgG intrathecal production could be detected with the IDEA seven times more often than with the Enzygnost Borreliosis. The determination of intrathecal production of IgM does not appear to be of diagnostic value in patients with delayed IgG antibody production. Therefore a consecutive lumbar puncture is more likely to confirm clinical assumption if there is strong clinical evidence of NB.
Seventy-one isolates of Borrelia burgdorferi sensu lato (B.b.s.l.) derived from Ixodes ricinus ticks (50 strains) and patients (21 strains) were characterised by PCR-RLFP analysis. In four cases the human isolates were obtained from the cerebrospinal fluid (CSF) of patients with clinical symptoms of neuroborreliosis and in 17 cases from skin biopsies of patients with dermatological manifestation of Lyme borreliosis. Ixodes ricinus isolates originated from 14 localities in three regions (Mur valley, eastern and western Styria) in Styria. Thirty six strains of B.b.s.l. were isolated from nymphal ticks, nine strains from female and five strains from male ticks. Species identification of human isolates revealed three B. garinii and one B. afzelii isolates in CSF. In the PCR-RFLP analysis of 17 skin specimens a pattern for B. afzelii was found in ten cases, while six could be identified as B. garinii and one as a mixed infection of B. afzelii and B. garinii. Genetic characterisation of tick isolates resulted in 24 strains of B. afzelii (48%), 11 strains of B. garinii (40%) and 5 strains of B. burgdorferi s.st. (10%); one isolate showed a mixed infection of B. afzelii and B. garinii. Our findings indicate that B. afzelii and B. garinii predominate over B. burgdorferi s.str. in Ixodes ricinus ticks from Styria, which is similar to findings in neighbouring countries. This also reflects the occurrence of different pathogenic Borrelia strains in human samples.
The use of AMPLILINK version 1.0 software was evaluated for the operation and control of one COBAS AMPLICOR instrument and for two COBAS AMPLICOR instruments run simultaneously to perform and detect nucleic acid amplification reactions. A total of 3,384 results were analyzed. The initial accuracy of the results was 99.91%. Three errors of omission of transfer of data from the COBAS AMPLICOR to the AMPLILINK system were observed. Two of these errors were from a single specimen, where both the analyte and internal control results were not transmitted. These errors did not interfere with the correctness of any other data. There were no interruptions of runs, and no data were mixed. AMPLILINK increased convenience, saved labor, and was found to be a very useful addition for clinical laboratories performing molecular-diagnostic procedures with the COBAS AMPLICOR system.
Accuracy of antigen determination in human plasma samples is often adversely affected by immune complex formation between antigens (e.g., HIV-1 p24 protein) and specific antibodies. In this study we describe an optimized method for complete immune complex dissociation (ICD) in plasma. This method is based on heat denaturation of antibodies and utilizes a defined solution of sodium dodecyl sulfate (SDS) and diethylenetriaminepentaacetic acid (DTPA) as diluent. The efficiency of this procedure for ICD was compared with those of published methods, employing heat denaturation alone and acidification. Plasma samples from patients participating in anti-retroviral treatments and samples reconstituted in vitro were treated and analyzed in parallel. HIV-1 p24 antigen was determined by quantitative enzyme-linked immunosorbent assay (ELISA). In 312 samples from 97 patients, antigenemia was found in 44.9% when measured directly and in 87.2% after this treatment. In a subset of 56 samples, 21.4% tested positive prior to treatment, while after either novel treatment, heat denaturation or acidification, these samples tested positive in 80.4%, 62.5% and 60.7%, respectively. In 94% of cases viral RNA was detected. This improved procedure for ICD provides a reliable and convenient method for complete and accurate p24 antigen detection in human plasma and is applicable to commercially available test kits.
OBJECTIVE:To define the usefulness of molecular parameters in patients with chronic hepatitis C who are undergoing antiviral therapy. Anti-hepatitis C virus (HCV) treatment was monitored by determination of serum HCV load and by presence of HCV RNA in peripheral blood mononuclear cells (PBMCs). STUDY DESIGN/METHODS:Fifty-one patients with chronic hepatitis C undergoing antiviral therapy with interferon-alpha plus ribavirin were studied. Serum HCV RNA load was tested with a quantitative assay (Amplicor HCV Monitor Test) before, during, and up to 12 months after end of treatment. If HCV RNA was not detectable, serum samples were subsequently tested with a qualitative assay (Cobas Amplicor HCV Test) and corresponding ethylenediaminetetraacetic acid (EDTA)-treated blood was checked for presence of HCV RNA in peripheral blood mononuclear cells (PBMCs). Sustained virologic response was defined by loss of HCV RNA 12 months after the end of treatment. RESULTS:Four patients (7.8%) were found to be sustained virologic responders, 17 (33.3%) were transient virologic responders, and 30 (58.8%) were virologic nonresponders. No significant difference was found in the median pretreatment serum HCV RNA load between sustained virologic responders, transient virologic responders, and virologic nonresponders. At 1 month after start of therapy, HCV RNA was not detectable with both the serum and the PBMC assay in 12 (23.5%) of 51 patients. Four remained HCV RNA-negative until 12 months after the end of treatment. In 14 of 17 transient virologic responders, reappearance of HCV RNA was detected earlier in PBMCs than in serum. CONCLUSIONS:Based on these results in 51 patients, quantitation of baseline serum HCV RNA does not appear to be a decisive factor to the management of the individual patient. Early assessment of serum HCV RNA level after start of anti-viral treatment seems to be of major importance to identify virologic nonresponders. Reappearance of HCV RNA may be demonstrated earlier in PBMCs than in serum.
Background: The Amplicor(TM) HBV Monitor Test for quantitative determination of serum hepatitis B virus (HBV) DNA has recently been introduced. This assay is based on PCR and a non-radioactive hybridization and detection system on microwell plates.Objective: The performance of the Amplicor(TM) HBV Monitor Test was evaluated in a routine diagnostic laboratory. The Amplicor(TM) HBV Monoitor assay was compared to the Digene Hybrid Capturer(TM) System HBV DNA assay for the quantitation of HBV in patient sera.Study design: Sensitivity and reproducibility were determined with 10-fold dilution series of two Eurohep HBV reference plasma specimens. Furthermore, 196 sera from 14 children with chronic HBV infection and interferon therapy were tested with both assays.Results: The detection limit was found to be 10(3) copies/ml with the Amplicor(TM) PCR assay compared to 10(6) to 10(7) copies/ml with the Digene(TM) hybridization assay. Both assays were quasi-linear over the measurable ranges. The new PCR assay proved to be very reliable. With the Amplicor(TM) PCR assay, 26.2% of the HBV DNA-positive clinical samples were found between 10(3) and 10(7) copies/ml and all of them tested below the detection limit with the hybridization assay.Conclusion: The Amplicor(TM) HBV Monitor Test shows excellent sensitivity and provides a valuable tool for the detection of HBV DNA in serum. It can be used for recognizing those patients who might benefit from antiviral therapy, for evaluation of the efficacy of anti-HBV therapy, and for validation of blood products. (C) 1998 Elsevier Science B.V. All rights reserved.
Abstract The Amplicor™ HBV Monitor Test for quantitative detection of serum hepatitis B virus (HBV) DNA has recently been introduced. This assay is based on PCR and a non-radioactive hybridization and detection system on microwell plates. Evaluation in a routine diagnostic laboratory showed excellent sensitivity and adequate reproducibility; however, a more automated format would be desirable. The Amplicor™ HBV Monitor Test is useful for recognizing those patients who might benefit from antiviral treatment and for evaluation of the efficacy of anti-hepatitis B virus treatment.
Polymerase chain reaction-based molecular assays are gaining increasing importance in the diagnosis and monitoring of infectious diseases. Over the past several years, the development and application of these techniques has initiated a revolution in the diagnosis and monitoring of hepatitis C infection. Presently, molecular assays are exclusively done in especially dedicated laboratories. Advances in automation will bring these technologies into routine diagnostic laboratories and will make them widely used.
A total of 1163 I. ricinus ticks were collected in 3 different regions (15 localities) in Styria (Austria) in June 1997 and examined for the presence of spirochetes by dark field microscopy. The mean infection rate was 20.8%. Among 310 adults, 24.2% were positive and among 853 nymphs, 19.6% were positive. All 15 collection areas were shown to harbour infected nymphs with a positivity rate ranging from 5.8% (3/52) to 32.1% (18/56). Isolation attempts in BSKII medium resulted in 29 isolates. Species identification by PCR-RFLP analysis revealed 16 strains of B. garinii, 10 strains of B. afzelii and 2 strains of B. burgdorferi s. s. One isolate showed a mixed population of B. garinii and B. afzelii. In two collection areas, all three major Borrelia species were shown to be present in the tick population.
Objectives: The antibody response in sera and tears of 167 patients with suspected chlamydial conjunctivitis was compared with the antibody response in sera and tears of 45 patients with symptoms of urogenital chlamydial infection to discover whether and which type of antichlamydial antibody detected in tears may be of diagnostic help in chlamydial conjunctivitis.Methods: Diagnosis was based on chlamydial antigen detection from the conjunctiva and urogenital tract, done by a direct immunofluorescence assay, McCoy cell culture, and polymerase chain reaction. Additionally, antichlamydial immunoglobulin A (IgA) and immunoglobulin G (IgG) were determined in sera and tears of all patients by an immunoperoxidase assay.Results: Two hundred twelve patients were examined - 167 with conjunctivitis, 45 with symptoms of urogenital chlamydial infection. Cell culture, direct immunofluorescence assay, and polymerase chain reaction brought identical results. Conjunctival specimens taken from 33 (20%) of the patients with conjunctivitis were Chlamydia antigen positive; specimens taken from 134 (80%) were negative. Antichlamydial antibodies were found in tears of 29 (88%) of the patients with conjunctivitis whose specimens were Chlamydia antigen positive. Fifty-four (40%) of the patients with conjunctivitis whose specimens were Chlamydia antigen negative had antichlamydial antibodies in their tears. Twenty-five patients with urethritis (56%) were Chlamydia antigen positive in urethral swabs; 20 (44%) were negative. Antichlamydial antibodies were found in the tears of eight (32%) of the Chlamydia antigen-positive and two (10%) of the Chlamydia antigen-negative patients with urethritis. In contrast to patients with conjunctivitis, findings for patients with urethritis always were negative for antichlamydial IgG in the tears.Conclusion: Antichlamydial antibodies in tears were seen significantly more of ten in patients with conjunctivitis than in those with urethritis (P less than or equal to 0.05). Antichlamydial IgG was found only in tears of patients with conjunctivitis. Therefore, the authors conclude that the detection of antichlamydial IgG in the tears might be helpful for diagnosis in patients with suspected chlamydial conjunctivitis who have antigen-negative conjunctival swabs.
Background: The COBAS AMPLICOR(TM) (CA) instrument for the amplification and detection steps of the AMPLICOR(TM) molecular diagnostic assays has recently been introduced. The system contains a single thermal cycler with two independently controlled heating/cooling blocks, a pipettor, a magnetic particle washer, a photometer and an incubator.Objective: The performance of the CA instrument was evaluated in a routine diagnostic laboratory for the detection of hepatitis C virus (HCV) RNA. The new system was compared with the corresponding microwell plate assay (AMPLICOR HCV Test).Study design: Routine clinical sera (350) from hemodialysis patients and patients with chronic HCV infection and interferon therapy were studied. If discrepant results were obtained, both assays were repeated (specimen preparation, amplification and detection); in addition, the HCV copy number was determined with the AMPLICOR HCV MONITOR(TM) Test.Results: There was a correlation between the CA HCV Test and the AMPLICOR HCV Test in 341 of 350 specimens (97%). After resolution of 9 discrepant results, the CA HCV Test gave a sensitivity of 97.8% and a specificity of 99.4%. The most common reason for discrepant results was a low HCV RNA copy number.Conclusion: The CA system was found to be a labor-saving, fast and reliable instrument for the amplification and detection steps of a RT-PCR molecular assay for detection of HCV RNA. (C) 1997 Elsevier Science B.V.