It is nowadays widely recognized that patient satisfaction following knee arthroplasty strongly depends on ligament balancing. To obtain this balancing, the occurring ligament strain is assumed to play a crucial role. To measure this strain, a method is described in this paper that allows full field 3D evaluation of the strains. The latter is preferred over traditional measurement techniques, e.g. displacement transducers or strain gauges, as human soft tissue is not expected to deform uniformly due to its highly inhomogeneous and anisotropic properties.To facilitate full field strain measurements, the 3D digital image correlation (DIC) technique was adopted. This technique was previously validated by our research group on human tissue. First, a high contrast speckle pattern was applied on the sMCL. Therefore, the specimens are first coated with a small layer of methylene blue. Following, a random white speckle pattern is applied. During knee flexion, two cameras simultaneously take pictures of the deform...
IntroductionIn this study, three-dimensional (3D) digital image correlation (DIC) was adopted to investigate the strain in the superficial medial collateral ligament (sMCL) of the human knee. To ou...
ABSTRACTThe three dimensional (3D) deformation of the superficial medial collateral ligament (sMCL) of the knee might play an important role in the understanding of the biomechanics of sMCL lesions. Therefore, the strain and deformation pattern of the sMCL during the range of motion were recorded in five cadaveric knees with digital image correlation. During knee flexion, the sMCL was found to deform in the three planes. In the sagittal plane, a rotation of the proximal part of the sMCL relative to the distal part occurred with the center of this rotation being the proximal tibial insertion site of the sMCL. This deformation generated high strains near the femoral insertion site of the sMCL. These strains were significantly higher than in the other parts and were maximal at 90° with on average +3.7% of strain and can explain why most lesions in clinical practice are seen in this proximal region. The deformation also has important implications for sMCL reconstruction techniques. Only a perfect anatomic restoration of the insertion sites of the sMCL on both the proximal and distal tibial insertion sites will be able to reproduce the isometry of the sMCL and thus provide the adequate stability throughout the range of motion. The fact that knee motion between 15° and 90° caused minimal strain in the sMCL might suggest that early passive range of motion in physical therapy postoperatively should have little risk of stretching a graft out in the case of an anatomical reconstruction. © 2016 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 34:2016–2024, 2016.
BACKGROUND:Trochlear dysplasia appears in different geometrical variations. The Dejour classification is widely used to grade the severity of trochlear dysplasia and to decide on treatment.PURPOSE:To investigate the effect of trochlear dysplasia on patellofemoral biomechanics and to determine if different types of trochlear dysplasia have different effects on patellofemoral biomechanics.STUDY DESIGN:Controlled laboratory study.METHODS:Trochlear dysplasia was simulated in 4 cadaveric knees by replacing the native cadaveric trochlea with different types of custom-made trochlear implants, manufactured with 3-dimensional printing. For each knee, 5 trochlear implants were designed: 1 implant simulated the native trochlea (control condition), and 4 implants simulated 4 types of trochlear dysplasia. The knees were subjected to 3 biomechanical tests: a squat simulation, an open chain extension simulation, and a patellar stability test. The patellofemoral kinematics, contact area, contact pressure, and stability were compared between the control condition (replica implants) and the trochlear dysplastic condition and among the subgroups of trochlear dysplasia.RESULTS:The patellofemoral joint in the trochlear dysplastic group showed increased internal rotation, lateral tilt, and lateral translation; increased contact pressures; decreased contact areas; and decreased stability when compared with the control group. Within the trochlear dysplastic group, the implants graded as Dejour type D showed the largest deviations for the kinematical parameters, and the implants graded as Dejour types B and D showed the largest deviations for the patellofemoral contact areas and pressures.CONCLUSION:Patellofemoral kinematics, contact area, contact pressure, and stability are significantly affected by trochlear dysplasia. Of all types of trochlear dysplasia, the models characterized with a pronounced trochlear bump showed the largest deviations in patellofemoral biomechanics.CLINICAL RELEVANCE:Investigating the relationship between the shape of the trochlea and patellofemoral biomechanics can provide insight into the short-term effects (maltracking, increased pressures, and instability) and long-term effects (osteoarthritis) of different types of trochlear dysplasia. Furthermore, this investigation provides an empirical explanation for better treatment outcomes of trochleoplasty for Dejour types B and D dysplasia.
Determining the mechanical behaviour of tendon and ligamentous tissue remains challenging, as it is anisotropic, non-linear and inhomogeneous in nature.
The authors hypothesise that the trochlear dysplastic distal femur is not only characterised by morphological changes to the trochlea. The purpose of this study is to describe the morphological characteristics of the trochlear dysplastic femur in and outside the trochlear region with a landmark-based 3D analysis.
To investigate the biomechanical effect of skeletal knee joint abnormalities, the authors propose to implant pathologically shaped rapid prototyped implants in cadaver knee specimens. This new method was validated by replacing the native trochlea by a replica implant on four cadaver knees with the aid of cadaver-specific guiding instruments. The accuracy of the guiding instruments was assessed by measuring the rotational errors of the cutting planes (on average 3.01° in extension and 1.18° in external/internal rotation). During a squat and open chain simulation, the patella showed small differences in its articulation with the native trochlea and the replica trochlea, which could partially be explained by the rotational errors of the implants. This study concludes that this method is valid to investigate the effect of knee joint abnormalities with a replica implant as a control condition to account for the influence of material properties and rotational errors of the implant.
This article presents a pilot study on a quasi-static knee rig designed to investigate the influence of pathologies and surgical interventions on the patellofemoral kinetics of cadaveric knees. The knee rig allows cadaveric knees to flex and extend under a simulated body weight by transmitting a force to the quadriceps tendon. During the squat simulation, the ground reaction force stays within physiological values. Before using this device to answer clinical questions, two knee specimens were tested to assess the repeatability of the rig. Four repeated flexion-extension cycles were performed under a simulated body weight of 700 N, with an isolated force on the quadriceps tendon up to 2700 N and with a ground reaction force close to 350 N. The resulting patellofemoral contact area shifted from distal to proximal during knee flexion. From 20 degrees to 60 degrees of knee flexion, the mean contact area and pressure increased from 80.2 +/- 3.3 to 349.5 +/- 10.1 mm2 and from 0.9 +/- 0.2 to 5.9 +/- 0.7 MPa, respectively. The transmitted force on the quadriceps tendon, the ground reaction force and the patellofemoral contact area and pressure were continuously measured and showed a relative variability of 1.6%, 2.4%, 2.8% and 3.2%, respectively. The presented knee rig shows a good repeatability that allows us to use this knee rig to quantify the influence of anatomical changes on the patellofemoral contact area and pressures during a squat simulation.