Advancement of techniques for 3D reconstruction of the optic disc could lead to affordable objective detection of glaucoma. Applying computer stereo vision techniques to image pairs is particularly promising. More data, along with the stereo camera calibration parameters and ground truths required for validation, could aid development. This work presents a method to generate, using a virtual environment, synthetic stereo images of optic discs from images in the CORD database and obtain the corresponding stereo camera calibration parameters and ground truths. Our own reconstruction technique was tested using data created using this environment and quantitatively validated.
Early detection and treatment are key in limiting vision loss from glaucoma, the second leading cause of blindness worldwide. Morphological alteration of the optic nerve head (ONH), detectable early in the condition, is a key clinical indicator. The mainstay for evaluation in clinics is the subjective assessment of stereoscopic ONH images. If quantitative diagnostic devices, which extract 3D information and use this to make an objective assessment, could be made affordable, it could mean greater diagnostic capability in primary/community care. A potentially cost-effective solution is to extract, using computer stereo vision, 3D information from stereo images obtained through a slit lamp, a mainstay of eye diagnostics, present in practically all ophthalmology and optometry practices. This work shows 3D ONH reconstruction in an eye phantom through a common slit lamp fitted with low cost cameras. Quantitative reconstructions, in close agreement with ground truths, were obtained.
Introduction: Retinal imaging is a fundamental tool in ophthalmic diagnostics. The potential use of retinal imaging within screening programs, with consequent need to analyze large numbers of images with high throughput, is pushing the digital image analysis field to find new solutions for the extraction of specific information from the retinal image. Areas covered: The aim of this review is to explore the latest progress in image processing techniques able to recognize specific retinal image features and potential features of disease. In particular, this review aims to describe publically available retinal image databases, highlight different performance evaluators commonly used within the field, outline current approaches in feature-based retinal image analysis and to map related trends. Expert commentary: This review found two key areas to be addressed for the future development of automatic retinal image analysis: fundus image quality and the affect image processing may impose on relevant clinical information within the images. Performance evaluators of the algorithms reviewed are very promising, however absolute values are difficult to interpret when validating system suitability for use within clinical practice.
PURPOSE To make an adaptable, head shaped radionuclide phantom to simulate molecular imaging of the brain using clinical acquisition and reconstruction protocols. This will allow the characterization and correction of scanner characteristics, and improve the accuracy of clinical image analysis, including the application of databases of normal subjects. METHODS A fused deposition modeling 3D printer was used to create a head shaped phantom made up of transaxial slabs, derived from a simulated MRI dataset. The attenuation of the printed polylactide (PLA), measured by means of the Hounsfield unit on CT scanning, was set to match that of the brain by adjusting the proportion of plastic filament and air (fill ratio). Transmission measurements were made to verify the attenuation of the printed slabs. The radionuclide distribution within the phantom was created by adding (99m)Tc pertechnetate to the ink cartridge of a paper printer and printing images of gray and white matter anatomy, segmented from the same MRI data. The complete subresolution sandwich phantom was assembled from alternate 3D printed slabs and radioactive paper sheets, and then imaged on a dual headed gamma camera to simulate an HMPAO SPECT scan. RESULTS Reconstructions of phantom scans successfully used automated ellipse fitting to apply attenuation correction. This removed the variability inherent in manual application of attenuation correction and registration inherent in existing cylindrical phantom designs. The resulting images were assessed visually and by count profiles and found to be similar to those from an existing elliptical PMMA phantom. CONCLUSIONS The authors have demonstrated the ability to create physically realistic HMPAO SPECT simulations using a novel head-shaped 3D printed subresolution sandwich method phantom. The phantom can be used to validate all neurological SPECT imaging applications. A simple modification of the phantom design to use thinner slabs would make it suitable for use in PET.
In the detection of glaucoma, the second leading cause of blindness worldwide, the alteration of the optic disc's morphology is a key clinical indicator. The current gold standard test, stereo funduscopy using stereo fundus cameras, is subjective. Quantitative devices exist but are prohibitively expensive. Work carried out elsewhere has demonstrated quantitative results from stereo matching fundus camera images. Building on this idea, the slit lamp microscope (a mainstay of eye diagnostics, present in practically all ophthalmology and optometry practices) has the potential to be used as a quantitative device. This study explored the feasibility of uncalibrated 3D reconstructions of retinal structures of a phantom eye's fundus using a slit lamp.