Background: Pediatric complex cranial vault reconstruction (CCVR) for repair of craniosynostosis is associated with significant analgesic requirements. Intravenous acetaminophen (IVAPAP) has been shown to be effective in reducing opioid requirements for other types of pediatric surgery. However, the efficacy of IVAPAP in CCVR has not been established. The aim of this study was to determine the impact of IVAPAP on perioperative opioid requirements for CCVR. Methods: Children 12 years of age or younger who underwent CCVR between June 2017 and August 2020 were retrospectively evaluated. The cohorts were patients who received intraoperative IVAPAP and those who did not. Patients who received other nonopioid intravenous (IV) analgesics intraoperatively were excluded. The primary outcome measure was intraoperative opioid requirements. Secondary outcome measures were postoperative opioid requirements, time to first opioid and total opioid requirement in the first 24 hours postoperatively. Opioid requirements were calculated using conversion to weight-based (mg/kg) IV morphine equivalents. Results: One hundred two patients met the inclusion criteria with 52 patients in the IVAPAP cohort and 50 in the non-IVAPAP cohort. Patients who received IVAPAP required significantly less postoperative oxycodone than those who did not receive IVAPAP. There were no differences in demographics, intraoperative opioid requirements, or total opioid requirement in the first 24 hours postoperatively between the 2 groups. Conclusions: Intraoperative IVAPAP is associated with reduced postoperative oxycodone administration. A prospective randomized controlled trial is needed to further investigate these findings.
Background Venous waveform analysis is an emerging technique to estimate intravascular fluid status by fast Fourier transform deconvolution. Fluid status has been shown proportional to f0, the amplitude of the fundamental frequency of the waveform’s cardiac wave upon deconvolution. Using a porcine model of distributive shock and fluid resuscitation, we sought to determine the influence of norepinephrine on f0 of the central venous waveform.Methods Eight pigs were anesthetized, catheterized and treated with norepinephrine after precipitation of endotoxemic hypotension, and subsequent fluid resuscitation to mimic sepsis physiology. Hemodynamic parameters and central venous waveforms were continually transduced throughout the protocol for post-hoc analysis. Central venous waveform f0 before, during and after norepinephrine administration were determined using Fourier analysis.Results Heart rate increased, while central venous pressure, pulmonary capillary wedge pressure and stroke volume decreased throughout norepinephrine administration (p < 0.05). Mean f0 at pre-norepinephrine, and doses 0.05, 0.10, 0.15, 0.20 and 0.25 mcg/kg/min, were 2.5, 1.4, 1.7, 1.7, 1.6 and 1.4 mmHg2, respectively (repeated measures ANOVA; p < 0.001). On post-hoc comparison to pre-norepinephrine, f0 at 0.05 mcg/kg/min was decreased (p = 0.04).Conclusions As the performance of f0 was previously characterized during fluid administration, these data offer novel insight into the performance of f0 during vasopressor delivery. Central venous waveform f0 is a decreased with norepinephrine, in concordance with pulmonary capillary wedge pressure. This allows contextualization of the novel, venous-derived signal f0 during vasopressor administration, a finding that must be understood prior to clinical translation.
This protocol describes an acute volume overload porcine model for adult Yorkshire pigs and piglets. Both swine ages undergo general anesthesia, endotracheal intubation, and mechanical ventilation. A central venous catheter and an arterial catheter are placed via surgical cutdown in the external jugular vein and carotid artery, respectively. A pulmonary artery catheter is placed through an introducer sheath of the central venous catheter. PlasmaLyte crystalloid solution is then administered at a rate of 100 mL/min in adult pigs and at 20 mL/kg boluses over 10 min in piglets. Hypervolemia is achieved either at 15% decrease in cardiac output or at 5 L in adult pigs and at 500 mL in piglets. Hemodynamic data, such as heart rate, respiratory rate, end-tidal carbon dioxide, fraction of oxygen-saturated hemoglobin, arterial blood pressure, central venous pressure, pulmonary artery pressure, pulmonary capillary wedge pressure, partial arterial oxygen pressure, lactate, pH, base excess, and pulmonary artery fraction of oxygen-saturated hemoglobin, are monitored during experimentation. Preliminary data observed with this model has demonstrated statistically significant changes and strong linear regressions between central hemodynamic parameters and acute volume overload in adult pigs. Only pulmonary capillary wedge pressure demonstrated both a linear regression and a statistical significance to acute volume overload in piglets. These models can aid scientists in the discovery of age-appropriate therapeutic and monitoring strategies to understand and prevent acute volume overload.
This protocol outlines an acute respiratory distress model utilizing centrally administered oleic acid infusion in Yorkshire pigs. Prior to experimentation, each pig underwent general anesthesia, endotracheal intubation, and mechanical ventilation, and was equipped with bilateral jugular vein central vascular access catheters. Oleic acid was administered through a dedicated pulmonary artery catheter at a rate of 0.2 mL/kg/h. The infusion lasted for 60-120 min, inducing respiratory distress. Throughout the experiment, various parameters including heart rate, respiratory rate, arterial blood pressure, central venous pressure, pulmonary artery pressure, pulmonary capillary wedge pressure, end-tidal carbon dioxide, peak airway pressures, and plateau pressures were monitored. Around the 60 min mark, decreases in partial arterial oxygen pressure (PaO2) and fraction of oxygen-saturated hemoglobin (SpO2) were observed. Periodic hemodynamic instability, accompanied by acute increases in pulmonary artery pressures, occurred during the infusion. Post-infusion, histological analysis of the lung parenchyma revealed changes indicative of parenchymal damage and acute disease processes, confirming the effectiveness of the model in simulating acute respiratory decompensation.
Understanding factors that increase risk of both mortality and specific measures of morbidity after duodenal switch (DS) is important in deciding to offer this weight loss operation. Artificial neural networks (ANN) are computational deep learning approaches that model complex interactions among input factors to optimally predict an outcome. Here, a comprehensive national database is examined for patient factors associated with poor outcomes, while comparing the performance of multivariate logistic regression and ANN models in predicting these outcomes. 2907 DS patients from the 2019 Metabolic and Bariatric Surgery Accreditation and Quality Improvement Program database were assessed for patient factors associated with the previously validated composite endpoint of 30-day postoperative reintervention, reoperation, readmission, or mortality using bivariate analysis. Variables associated (P ≤ 0.05) with the endpoint were imputed in a multivariate logistic regression model and a three-node ANN with 20
Introduction: A cornerstone of heart failure assessment is the right heart catheterization and the pulmonary capillary wedge pressure measurement it can provide. Clinical and hemodynamic parameters such as weight and jugular venous distention are less invasive measures often used to diagnose, manage, and treat these patients. To date, there is little data looking at the association of these key parameters to measured pulmonary capillary wedge pressure (PCWP). This is a large, retrospective, secondary analysis of a right heart catheterization database comparing clinical and hemodynamic parameters against measured PCWP in heart failure patients. Methods: A total of 538 subjects were included in this secondary analysis. Spearman’s Rho analysis of each clinical and hemodynamic variable was used to compare their association to the documented PCWP. Variables analyzed included weight, body mass index (BMI), jugular venous distention (JVD), creatinine, edema grade, right atrial pressure (RAP), pulmonary artery systolic pressure (PASP), systemic vascular resistance, pulmonary vascular resistance, cardiac output (thermal and Fick), systolic blood pressure, diastolic blood pressure, heart rate, respiratory rate, oxygen saturation (SpO2), and pulmonary artery diastolic pressure (PADP). Results: Ten out of 17 selected parameters had a statistically significant association with measured PCWP values. PADP had the strongest association (0.73, p<0.0001), followed by RAP and PASP (0.69, p<0.0001 and 0.67, p<0.0001, respectively). Other significant parameters included weight (0.2, p<0.001), BMI (0.2, p<0.001), SpO2 (-0.17, p<0.0091), JVD (0.24, p<0.005) and edema grade (0.2, p<0.0001). Conclusion: This retrospective analysis clarifies the associations of commonly used clinical and hemodynamic parameters to the clinically used gold standard for volume assessment in heart failure patients, PCWP.
Background Animal models of distributive hypotension and resuscitation allow the assessment of hemodynamic monitoring modalities and resuscitation strategies. The fluid-first paradigm for resuscitation is currently being challenged with clinical trials. In this investigation, venous return and perfusion are assessed, and full hemodynamics are characterized, in a porcine model of endotoxemic hypotension with and without fluid pre-loading. Methods Two groups of six pigs had the induction of standardized endotoxemic hypotension (“critical hypotension”). Group 1 underwent four 10 cc/kg crystalloid boluses, and Group 2 was not fluid pre-resuscitated. Both groups underwent progressive norepinephrine (NE) up-titration to 0.25 mcg/kg/minute over 30 minutes. Vital signs, central parameters, and laboratory values were obtained at baseline, “critical hypotension,” after each bolus and during NE administration. Results Endotoxemia decreased the systemic vascular resistance (SVR) in Group 1 (1031±106 dyn/s/cm-5 versus 738±258 dyn/s/cm-5; P=0.03) and Group 2 (1121±196 dyn/s/cm-5 versus 759±342 dyn/s/cm-5; P=0.003). In Group 1, the four fluid boluses decreased heart rate (HR), pulmonary capillary wedge pressure (PCWP), and central venous pressure (CVP) (P<0.05). No changes were observed in blood pressure, cardiac output (CO), or lactate. NE up-titration increased HR in Group 1 and decreased CVP in both groups. Higher final CVP (11 {3} versus 4 {4} mmHg; P=0.01) and PCWP (5 {1} versus 2 {2} mmHg; P=0.005) values were observed in Group 1 relative to Group 2, reflecting increased venous return. Conclusions Porcine endotoxemic hypotension and resuscitation were robustly characterized. In this model, fluid loading improved venous return with NE, though perfusion (CO) was preserved by increased NE-induced chronotropy.
BACKGROUND:Cardiac output (CO) is a valuable proxy for perfusion, and governs volume responsiveness during resuscitation from distributive shock. The underappreciated venous system has nuanced physiology that confers valuable hemodynamic information. In this investigation, deconvolution of the central venous waveform by the fast Fourier transformation (FFT) algorithm is performed to assess its ability to constitute a CO surrogate in a porcine model of endotoxemia-induced distributive hypotension and resuscitation.STUDY DESIGN:Ten pigs were anesthetized, catheterized, and intubated. A lipopolysaccharides infusion protocol was used to precipitate low systemic vascular resistance hypotension. Four crystalloid boluses (10 cc/kg) were then given in succession, after which heart rate, mean arterial pressure, thermodilution-derived CO, central venous pressure (CVP), and the central venous waveform were collected, the last undergoing fast Fourier transformation analysis. The amplitude of the fundamental frequency of the central venous waveform's cardiac wave (f0-CVP) was obtained. Heart rate, mean arterial pressure, CVP, f0-CVP, and CO were plotted over the course of the boluses to determine whether f0-CVP tracked with CO better than the vital signs, or than CVP itself.RESULTS:Distributive hypotension to a 25% mean arterial pressure decrement was achieved, with decreased systemic vascular resistance (mean 918 ± 227 [SD] dyne/s/cm-5 vs 685 ± 180 dyne/s/cm-5; p = 0.038). Full hemodynamic parameters characterizing this model were reported. Slopes of linear regression lines of heart rate, mean arterial pressure, CVP, f0-CVP, and CO were -2.8, 1.7, 1.8, 0.40, and 0.35, respectively, demonstrating that f0-CVP values closely track with CO over the 4-bolus range.CONCLUSIONS:Fast Fourier transformation analysis of the central venous waveform may allow real-time assessment of CO during resuscitation from distributive hypotension, possibly offering a venous-based approach to clinical estimation of volume responsiveness.
Introduction: Clinical symptoms of heart failure commonly include fatigue, edema, and shortness of breath. Unfortunately, clinical monitoring has proven to be unreliable for the assessment of congestion and predicting the need for hospitalization. Biosensing wearables have been developed as a potential adjunct to clinical signs and symptoms. Hypothesis: This report hypothesis a correlation between clinicians’ signs and symptoms of heart failure along with bioimpedance measurements (ZOE ® ), and pulmonary capillary wedge pressure (PCWP). Methods: One hundred and fifty-five subjects undergoing right heart catheterization (RHC) at Vanderbilt University Medical Center (VUMC) were prospectively enrolled. A Zo value (ohms) was obtained, jugular venous pressure (JVP) was estimated, edema graded, and dyspnea assessed in all subjects. RHC was performed by scheduled cardiologist per routine. One-way ANOVA was performed to assess relationship between dependent and independent variables. A Pearson correlation coefficient was used to compare Zo value and PCWP. Results: Neither estimated JVP (cmH 2 O) (p = 0.65, n=110) nor edema scores (p = 0.12, n=110) demonstrated a significant relationship to PCWP (Figure 1). The presence of subjective SOB also did not demonstrate significant association with PCWP (p = 0.99, n=110; Figure 1). There was no correlation between ZOE ® and PCWP (r = -0.08, p = 0.56, n=56; Figure 2). Conclusions: These findings support the idea that traditional measures for monitoring heart failure patients are limited.
INTRODUCTION: Respiratory disease, acute and chronic, can be difficult to diagnose and monitor. To date, there are only two standard non-invasive monitoring approaches for assessing respiratory distress: respiratory rate and SpO2. The Respiratory non-Invasive Venous waveform Analysis (RIVA) was first described in COVID-19 patients as a promising, novel physiological measurement that predicted a COVID-19+ patient's need for oxygen support therapy. The aim of this study was to investigate if this RIVA signal was present in chronic pulmonary conditions. METHODS: Secondary analysis of a venous waveform dataset of human subjects that had pulmonary function tests (PFT) were analyzed to assess how their chronic respiratory illnesses affected the magnitude of their respiratory signal. Data was captured via a non-invasive piezoelectric sensor and analyzed on LabChart 8. Using spectral analysis in 8K windows, the respiratory peak of the signal (low frequency ~0.2 Hz) was measured for magnitude relative to their cardiac peak (higher frequency ~1.0 Hz) to calculate RIVA-RI (respiratory peak/cardiac peak). These values were grouped according to their pulmonary disease and an ANOVA with multiple comparisons was conducted to determine the significance between groups. RESULTS: Healthy control subjects displayed significantly lower RIVA-RI values compared to patients reporting the PFT lab with asthma or idiopathic pulmonary fibrosis (IPF;p < 0.05). Patients with chronic obstructive pulmonary disease, pulmonary hypertension, and/or obstructive sleep apnea did not have significant RIVA-RI values compared to healthy controls. CONCLUSIONS: This novel signal, first discovered in COVID-19+ patients that required oxygen support therapy, is also present in asthmatic and IPF patients. More research is needed to better understand the respiratory venous signal and how it could be used to monitor respiratory disease.
:Minimally-invasive endoscopic-assisted craniectomy (EAC) achieves similar functional and cosmetic outcomes, whereas reducing morbidity risk that is often associated with complex cranial vault reconstruction. Antifibrinolytics (AF) usage to limit blood loss and transfusion requirements during complex cranial vault reconstruction has been studied extensively; however, studies are limited for AF therapy in EAC. The aim of this single-center retrospective observational cohort pilot study was to evaluate whether the use of AF was associated with reduced blood loss in infants undergoing EAC. The authors hypothesized that there would be no difference in blood loss between patients who received AF and those that did not receive AF during EAC. Non-syndromic patients who underwent single-suture EAC were retrospectively evaluated. Primary outcome measure was intraoperative calculated blood loss (mL/kg). Secondary outcome measures included perioperative red blood cells transfusion volumes, number of blood donor exposures, and pediatric intensive care unit and total hospital length of stay. Study cohort demographic and outcome data were analyzed; Fisher exact test was used for categorical data, Student t test was used for continuous data. A P value of <0.05 was considered statistically significant. Forty-nine EAC patients were included in the study with 34 patients in the AF cohort and 15 patients in the non-AF cohort. There were no significant differences in demographics between the 2 groups. Additionally, there was no significant difference in intraoperative calculated blood loss or any secondary outcome measure. In our single-suture EAC study cohorts, AF administration was not associated with a decrease in blood loss when compared to those that did not receive AF therapy.
Background: Heart failure is the leading cause of hospitalization in the elderly and readmis-sion is common. Clinical indicators of congestion may not precede acute congestion with enough time to prevent hospital admission for heart failure. Thus, there is a large and unmet need for accurate, noninvasive assessment of congestion. Noninvasive venous waveform anal-ysis in heart failure (NIVAHF) is a novel, noninvasive technology that monitors intravascular volume status and hemodynamic congestion. The objective of this study was to determine the correlation of NIVAHF with pulmonary capillary wedge pressure (PCWP) and the ability of NIVAHF to predict 30-day admission after right heart catheterization.Methods and Results: The prototype NIVAHF device was compared with the PCWP in 106 patients undergoing right heart catheterization. The NIVAHF algorithm was developed and trained to estimate the PCWP. NIVA scores and central hemodynamic parameters (PCWP, pulmo-nary artery diastolic pressure, and cardiac output) were evaluated in 84 patients undergoing out -patient right heart catheterization. Receiver operating characteristic curves were used to determine whether a NIVA score predicted 30-day hospital admission. The NIVA score demon-strated a positive correlation with PCWP (r = 0.92, n = 106, P < .0001). The NIVA score at the time of hospital discharge predicted 30-day admission with an AUC of 0.84, a NIVA score of more than 18 predicted admission with a sensitivity of 91% and specificity of 56%. Residual analysis sug-gested that no single patient demographic confounded the predictive accuracy of the NIVA score.Conclusions: The NIVAHF score is a noninvasive monitoring technology that is designed to provide an estimate of PCWP. A NIVA score of more than 18 indicated an increased risk for 30-day hospital admission. This noninvasive measurement has the potential for guiding decongestive therapy and the prevention of hospital admission in patients with heart failure.(J Cardiac Fail 2022;28:1692-1702)
OBJECTIVES:. Due to the rapid rate of severe acute respiratory syndrome coronavirus 2 transmission and the heterogeneity of symptoms of coronavirus disease 2019, expeditious and effective triage is critical for early treatment and effective allocation of hospital resources. DESIGN:. A post hoc analysis of respiratory data from non-invasive venous waveform analysis among patients enrolled in an observational study was performed. SETTING:. Vanderbilt University Medical Center. PATIENTS:. Peripheral venous waveforms were recorded from admission to discharge in enrolled coronavirus disease 2019–positive patients and healthy age-matched controls. INTERVENTIONS:. Data were analyzed in LabChart 8 to transform venous waveforms to the frequency domain using fast Fourier transforms. The peak respiratory frequency was normalized to the peak cardiac frequency to generate a respiratory non-invasive venous waveform analysis respiratory index. Paired Fisher exact tests were used to compare each patient’s respiratory non-invasive venous waveform analysis respiratory index at admission and discharge. A nonparametric one-way analysis of variance was used for multiple comparisons between patients with coronavirus disease 2019 and healthy controls for respiratory non-invasive venous waveform analysis respiratory index. MEASUREMENTS AND MAIN RESULTS:. Fifty coronavirus disease 2019–positive patients were enrolled between April 2020, and September 2020, and 45 were analyzed; 34 required supplemental oxygen and 11 did not. The respiratory non-invasive venous waveform analysis respiratory index was significantly higher for the 34 patients with coronavirus disease 2019 who received supplemental oxygen (median, 0.27; interquartile range, 0.11—1.28) compared with the 34 healthy controls (median, 0.06; interquartile range, 0.03–0.14) (p < 0.01). For patients with coronavirus disease 2019 who received supplemental oxygen, respiratory non-invasive venous waveform analysis respiratory index was significantly lower at hospital discharge (p = 0.02; 95% CI, 0.10–1.9) compared with hospital admission (median = 0.12; interquartile range, 0.05–0.56). For patients with coronavirus disease 2019, a respiratory non-invasive venous waveform analysis respiratory index of 0.64 demonstrated sensitivity of 92%, specificity of 47%, and positive predictive value of 93% for predicting requirement of supplemental oxygen during the hospitalization. CONCLUSIONS:. Respiratory non-invasive venous waveform analysis respiratory index represents a novel physiologic respiratory measurement with a promising ability to triage early care and predict the need for oxygen support therapy in coronavirus disease 2019 patients.
Alvis, Bret; Vaughn, Lexie; Polcz, Monica; Wise, Eric; Brophy, Colleen; Hocking, Kyle Author Information