Determining the viability of residual tumor masses is a great challenge after primary treatment of Hodgkin lymphoma. FDG-PET may play a crucial role in this procedure. In this study, files of 128 Hodgkin lymphoma patients were reviewed, who were treated in three Hungarian hematology centers between January 1995 and February 2005. CT scan showed residual tumor mass by all of them. Their median follow-up was 75.5 months from PET examination. The number of true-positive, true-negative, false-positive, false-negative subjects were 29, 83, 10, 6, respectively. Sensitivity of post-treatment FDG-PET was 83 %, specificity 93 %, positive predictive value 74 %, negative predictive value 93 %, and accuracy 88 %. The difference between the event free survival of PET positive and negative cases is highly significant (p=0.0000), according to the Mantel-Cox test. Our results in the largest cohort of patients, in accordance with literature, clearly indicates that patients with negative FDG-PET results are unlikely to progress or relapse during the longest follow-up.
We report on a distributed online coincidence detection implementation that we have recently added to the miniPET-II small animal PET scanner. The implementation uses standard Ethernet and IP multicasting techniques, therefore no architectural changes were necessary to the existing system. For 2D reconstruction the implementation scales with the number of detectors in the system, so it can be used for larger ring configurations, too. The online coincidence detection makes the system suitable for real time imaging applications.
A full ring small animal PET camera (MiniPET-II) has been built in our institute as part of an R+D project. In this work we determined the performance parameters of the MiniPET-II scanner. The measurements and data evaluation for this purpose were based on the National Electrical Manufacturers Association (NEMA) NU-4 standards. The spatial resolution varies between 1.4 to 2.1 mm from central to 25 mm radial distances. The system sensitivity was 1.14%. The counting rate capability, expressed in noise equivalent counting rate (NEC), was shown to peak of over 55.1 kcps at 38.9 MBq using a mouse phantom. The scatter fraction with the same acquisition was 12.3%. Evaluations of image quality and quantization accuracy were also performed using the NEMA NU-4 required image-quality phantom and animal studies. The study proved that the MiniPET-II scanner has a good imaging capability and ability to perform real animal studies.
We report on the architecture of the system-on- module (SoM) developed by our group for miniPET-II, the second version of our small animal PET scanner. The paper describes the hardware and software implementation details of the SoM we realized inside the miniPET-II detector module, the embedded Linux operation system, and the the initial results of bandwidth test measurements on the assembled SoM. Detailed description is given on the interfacing of the updated miniPET IP Core to the SoM, on the efficient data transfer method that implements device-to-device DMA transfer, and on the usage of User Datagram Protocol (UDP/IP) for high speed data transfer.
Iterative reconstruction methods are commonly used to obtain images with high resolution and good signal-to-noise ratio in nuclear imaging. The aim of this work was to develop a scalable, fast, cluster based, fully 3-D iterative image reconstruction package for our small animal PET camera, the miniPET. The reconstruction package is developed to determine the 3-D radioactivity distribution from list mode type of data sets and it can also simulate noise-free projections of digital phantoms. We separated the system matrix generation and the fully 3-D iterative reconstruction process. As the detector geometry is fixed for a given camera, the system matrix describing this geometry is calculated only once and used for every image reconstruction, making the process much faster. The Poisson and the random noise sensitivity of the ML-EM iterative algorithm were studied for our small animal PET system with the help of the simulation and reconstruction tool. The reconstruction tool has also been tested with data collected by the miniPET from a line and a cylinder shaped phantom and also a rat.
A gamma camera has been updated and converted to serve as a demonstrator for educational purposes. The gantry and the camera head were the only part of the system that remained untouched. The main reason for this modernization was to increase the transparency of the gamma camera by partitioning the different logical building blocks of the system and thus providing access for inspection and improvements throughout the chain. New data acquisition and reconstruction software has been installed.By taking these measures, the camera is now used in education and also serves as a platform for tests of new hardware and software solutions. The camera is also used to demonstrate 3D (SPECT) imaging by collecting 2D projections from a rotatable cylindrical phantom. Since the camera head is not attached mechanically to the phantom, the effect of misalignment between the head and the rotation axis of the phantom can be studied. (c) 2006 Elsevier B.V. All rights reserved.
Engineers specialized in multimodal tomography regularly face a wide scale of programming tasks requiring an integrated software system to ensure cost efficiency. Accordingly, a software development framework has been worked out comprising libraries for cluster-based data acquisition, image reconstruction, management of data files and complex multimodal volumetric visualization. This framework enabled us to develop complex software for our miniPET project [Kis et al., 2005], This software contains a graphical application integrating data acquisition, cluster monitoring, event sorting, image reconstruction, interactive image processing tools for advanced multimodal visualization. It also contains utilities to solve these tasks without graphical user interface. The components of our acquisition program can run on embedded Linux systems making new ways to develop any other types of data acquisition software that uses embedded Linux systems. A versatile development framework is developed containing specific libraries and special file formats that support multimodal tomography. This framework was successfully used to elaborate our complex miniPET software.
In vivo imaging of small laboratory animals is a valuable tool in the development of new drugs. For this purpose, miniPET, an easy to scale modular small animal PET camera has been developed at our institutes. The system has four modules, which makes it possible to rotate the whole detector system around the axis of the field of view. Data collection and image reconstruction are performed using a data acquisition (DAQ) module with Ethernet communication facility and a computer cluster of commercial PCs. Performance tests were carried out to determine system parameters, such as energy resolution, sensitivity and noise equivalent count rate. A modified GEANT4-based GATE Monte Carlo software package was used to simulate PET data analogous to those of the performance measurements. GATE was run on a Linux cluster of 10 processors (64 bit, Xeon with 3.0GHz) and controlled by a SUN grid engine. The application of this special computer cluster reduced the time necessary for the simulations by an order of magnitude. The simulated energy spectra, maximum rate of true coincidences and sensitivity of the camera were in good agreement with the measured parameters.
Resting cerebral glucose metabolism was assessed by 18[F]-fluorodeoxyglucose in 11 Down syndrome patients. Standardized uptake values were determined on a pixel-by-pixel basis from the measured tissue-activity data. The results revealed a mean overall 18[F]-fluorodeoxyglucose uptake in the Down syndrome patients close to that observed in the control group, consisting of children and young adults. However, the standard deviation of the standardized uptake values was much higher in the Down syndrome group in almost all voxels relating to the gray matter. The statistical parametric mapping method was applied to compare the cerebral 18[F]-fluorodeoxyglucose accumulation patterns of the Down syndrome and control groups. Six regions (clusters) were found for which the glucose uptake was higher in the Down syndrome patients than in the control group. The anatomic localization of these clusters was based on magnetic resonance investigations and a brain-atlas technique. The localization of the identified clusters with an increased glucose metabolism in the Down syndrome patients suggests that these subjects have an enhanced resting neuronal activity in cortical areas involved in reasoning, cognition, and speech as compared with normal subjects.