PURPOSE:The posterior cruciate-retaining (CR) design offers rotational freedom but risks abnormal kinematics and instability. The medial pivot (MP) design mimics native joint motion with a high-conformity medial and flat lateral interface. Within clinical studies, the MP design outclassed the CR design, but biomechanical studies are lacking. This study investigates the tibiofemoral and patellofemoral kinematics of both implant designs compared to native kinematics. METHODS:Eight fresh-frozen cadaveric knee specimens underwent total knee arthroplasty using MP and CR designs. Testing was performed in a dynamic knee rig simulating active knee flexion (30-130°) under muscle load. Biomechanical assessments included tibial rotation, tibiofemoral translation, patellar tilt/shift, patellofemoral contact/pressure patterns and quadriceps force. Functional regressions were used to analyse the effects of the component designs on the native situation. RESULTS:The MP design exhibited increased tibial rotation (130° flexion: MP 9.4° vs. CR 6.6°) and lateral anterior tibial translation during flexion (130° flexion: MP 25.8 mm vs. CR 22.6 mm). Both designs showed no significant differences in patellar tilt or shift and similar patellofemoral pressure (CR 3.2 MPa, MP 3.4 MPa) and contact patterns (CR 213.8 mm2 vs. MP 230.4 mm2). The MP design required lower quadriceps force, particularly in deep flexion (NS 452.6 N, CR 407.8 N and MP 367.3 N). CONCLUSION:The MP design provides a more native-like knee kinematic profile than the CR design, with a more pronounced MP motion pattern and reduced quadriceps loading. LEVEL OF EVIDENCE:Not applicable.
IntroductionThe demographic shift leads to a tremendous increase in age-related diseases, which are often chronic. Therefore, a focus of chronic disease management should be set on the maintenance or even improvement of the patients’ quality of life (QoL). One indicator to objectively measure QoL is the EQ-5D questionnaire, which was validated in a disease- and world region-specific manner. The aim of this study was to conduct a systematic literature review and meta-analysis on the QoL across the most frequent chronic diseases that utilized the EQ-5D and performed a disease-specific meta-analysis for treatment-dependent QoL improvement.Materials and methodsThe most common chronic disease in Germany were identified by their ICD-10 codes, followed by a systematic literature review of these ICD-10 codes and the EQ-5D index values. Finally, out of 10,016 independently -screened studies by two persons, 538 studies were included in the systematic review and 216 studies in the meta-analysis, respectively.ResultsWe found significant medium to large effect sizes of treatment effects, i.e., effect size >0.5, in musculoskeletal conditions with the exception of fractures, for chronic depression and for stroke. The effect size did not differ significantly from zero for breast and lung cancer and were significantly negative for fractures.ConclusionOur analysis showed a large variation between baseline and post-treatment scores on the EQ-5D health index, depending on the health condition. We found large gains in health-related quality of life mainly for interventions for musculoskeletal disease.Systematic review registrationhttps://www.crd.york.ac.uk/prospero/display_record.php?ID=CRD42020150936, PROSPERO identifier CRD42020150936.
The two most commonly instrumented gait analysis tools used are Optical Motion Capture systems (OMC) and Inertial Measurement Units (IMU). To date, OMC based gait analysis is considered the gold-standard. Still, it is space-, cost-, and time-intense. On the other hand IMU systems are more cost- and time effective but simulate the whole foot as a single segment. To get a more detailed model of the foot and ankle, a new 2-segment foot model using IMU was developed, comparable to the multi-segment foot models assessed by OMC. Can an IMU based 2-segment foot model be developed to provide a more detailed representation of the foot and ankle kinematics? To establish a 2-segment foot model, in addition to the previous 1-segment foot model an IMU sensor was added to the calcaneus. This allowed the differentiation between the hindfoot and forefoot kinematics. 30 healthy individuals (mean age 27 ± 7 years) were recruited to create a norm data set of a healthy cohort. Moreover, the kinematic data of the 2-segment foot model were compared to those of the traditional 1-segment foot model using statistical parametric mapping. The 2-segment foot model proved to be applicable. Furthermore, it allowed for a more detailed representation of the foot and ankle joints, similar to other multi-segment foot model. The healthy cohort’s norm data set showed a homogeneous motion pattern for gait. The 2-segment foot model allows for an extension of IMU-based gait analysis. Futures studies must prove the reliability and validity of the 2-segment foot model in healthy and pathologic situations. Level II.
Background: Anterior knee pain is a prevalent issue post total knee arthroplasty, often necessitating revision surgery. Various factors contribute to this complication, including patellar maltracking and excessive patellofemoral load. Kinematic alignment has emerged as an alternative, showing promising outcomes in clinical studies. However, its impact on patellofemoral biomechanics needs to be more adequately understood. This study compared the effects of kinematically versus mechanically aligned total knee arthroplasty on patellofemoral joint biomechanics. Methods: Eight fresh-frozen human knee specimens underwent biomechanical testing in a knee rig setup, performing an active weight-loaded knee joint flexion of 30–130°. After the testing of native kinematics, kinematically and mechanically aligned total knee arthroplasty was performed using a medial pivot implant design without patellar resurfacing. Quadriceps force, retropatellar peak pressure and the retropatellar contact area were measured during knee flexion using a patellar pressure-sensitive film. Patella kinematics (shift and tilt) was tracked using an optoelectrical measurement system. Functional regressions were used to determine the influence of the alignment on the kinematics and loading of the knee joint. Results: Kinematically aligned total knee arthroplasty resulted in reduced quadriceps force during knee flexion compared to mechanically aligned total knee arthroplasty. Retropatellar peak pressure, retropatellar contact area and patella kinematics did not vary between the alignments. Conclusions: Kinematic alignment offers potential benefits in reducing quadriceps force during knee flexion, which may mitigate anterior knee pain risk. Further research is needed to elucidate its effects in varying anatomical conditions and alignment strategies.
Abstract Introduction Arthrodesis of a (diseased) ankle joint is usually performed to achieve pain relief and stability. One basic principle of arthrodesis techniques includes rigid fixation of the surfaces until union. It seems plausible that stable anchoring and homogeneous pressure distribution should be advantageous, however, it has not been investigated yet. The aim is to achieve uniform compression, as this is expected to produce favorable results for the bony fusion of the intended arthrodesis. Numerous implants with different biomechanical concepts can be used for ankle fusion. In this study, headless compression screws (HCS, DePuy Synthes, Zuchwil, Switzerland) were compared biomechanically to an alternative fixation System, the IOFix device (Extremity Medical, Parsippany, NJ, USA) in regard to the distribution of the compression force (area of contact) and peak compression in a sawbone arthrodesis-model (Sawbones® Pacific Research Laboratories, Vashon, WA, USA). This study aims to quantify the area of contact between the bone interface that can be obtained using headless compression screws compared to the IOFix. In current literature, it is assumed, that a large contact surface with sufficient pressure between the bones brings good clinical results. However, there are no clinical or biomechanical studies, that describe the optimal compression pressure for an arthrodesis. Material and methods Two standardized sawbone blocks were placed above each other in a custom-made jig. IOFix and headless compression screws were inserted pairwise parallel to each other using a template for a uniform drilling pattern. All screws were inserted with a predefined torque of 0.5 Nm. Pressure transducers positioned between the two sawbone blocks were compressed for the measurement of peak compression force, compression distribution, and area of contact. Results With the IOFix, the compression force was distributed over significantly larger areas compared to the contact area of the HCS screws, resulting in a more homogenous contact area over the entire arthrodesis surface. Maximum compression force showed no significant difference. Conclusion The IOFix system distributes the compression pressure over a much larger area, resulting in more evenly spread compression at the surface. Clinical studies must show whether this leads to a lower pseudarthrosis rate.
BACKGROUND:The one of the most commonly used reference system for clinical gait analysis is an optical motion capture system (OMC) using a multi-segment foot model. A time- and cost-efficient alternative could be an inertial measurement unit (IMU)-based systems. However, these are limited to a single segment approach for the foot and ankle. Therefore, the current setup was modified to be based on a 2-segment foot model, allowing for a separate analysis of the hind- and midfoot. The study aimed to evaluate the reliability (inter-rater, intra-rater, and test-retest reliability) of an IMU-based 2-segment foot model. MATERIAL AND METHODS:Twelve healthy subjects were recruited to test the inter-rater, intra-rater, and test-retest reliability of the new IMU based 2-segment foot model. Gait analysis was performed on a treadmill at a constant speed of 4 km/h. Kinematic data of the tibia/hindfoot, tibia/forefoot and hindfoot/forefoot over 100 % gait cycle were analyzed. The reliability was tested by using statistical parametric mapping (SPM) and the intraclass correlation coefficient (ICC). RESULTS:The SPM showed no significant difference for inter-, intra-rater, and test-retest reliability, but for a small segment of tibia/forefoot dorsiflexion test-retest reliability (2.1° difference). The single standard deviation measurement error for the sagittal and transverse plane was <5° and worse for the frontal plane. CONCLUSION:The new 2-segment foot model revealed a high inter-rater, intra-rater, and test-retest reliability. It is suitable for use in adult clinical practice. Still, comparative data to the OMC system using a multi-segment foot model are missing.
The response of soft tissue to loading can be obtained by strain assessment. Typically, strain can be measured using electrical resistance with strain gauges (SG), or optical sensors based on the digital image correlation (DIC), among others. These sensor systems are already established in other areas of technology. However, sensors have a limited range of applications in medical technology due to various challenges in handling human soft materials. The aim of this study was to compare directly attached foil-type SG and 3D-DIC to determine the strain of axially loaded human ligament structures. Therefore, the medial (MCL) and lateral (LCL) collateral ligaments of 18 human knee joints underwent cyclic displacement-controlled loading at a rate of 20 mm/min in two test trials. In the first trial, strain was recorded with the 3D-DIC system and the reference strain of the testing machine. In the second trial, strain was additionally measured with a directly attached SG. The results of the strain measurement with the 3D-DIC system did not differ significantly from the reference strain in the first trial. The strains assessed in the second trial between reference and SG, as well as between reference and 3D-DIC showed significant differences. This suggests that using an optical system based on the DIC with a given unrestricted view is an effective method to measure the superficial strain of human ligaments. In contrast, directly attached SGs provide only qualitative comparable results. Therefore, their scope on human ligaments is limited to the evaluation of changes under different conditions.
Die Einlagenversorgung im Leistungssport stellt den Orthopädieschuhmacher vor besondere Herausforderungen. Auch wenn sich der Versorgungsablauf im Grundsatz kaum von dem bei Alltagspatienten unterscheidet, gilt es hinsichtlich der Befundung und Analyse sportspezifische Aspekte zu berücksichtigen. Die hierzu notwendigen Kenntnisse über funktionelle Anatomie, Pathologie und Biomechanik sind Voraussetzung, um den individuellen Bedürfnissen der Athleten zu begegnen und Beeinträchtigungen in dem eng getakteten Wettkampfkalender durch Fehlversorgungen zu vermeiden. Ziel dieses Beitrags ist es daher, ausgehend von einem Überblick über den allgemeinen Versorgungsstandard, ausgewählte Besonderheiten in der sportspezifischen Analyse darzustellen und deren Implikationen für die Einlagenversorgung auch anhand von Fallbeispielen zu verdeutlichen.The provision of insoles in elite sports presents special challenges for orthopedic shoemakers. Although the supply process is essentially no different from that for everyday patients, it is important to consider important, sport-specific aspects with regard to the diagnosis and analysis. Knowledge of functional anatomy, pathology, and biomechanics is essential to meet the individual needs of athletes and avoid downtime in the tightly scheduled competition calendar due to incorrect treatments. The aim of this article is therefore to outline selected features of sports analysis based on an overview of the general standard of care and to highlight their implications for insole provision, using case examples.
Die Einlagenversorgung im Leistungssport stellt den Orthopädieschuhmacher vor besondere Herausforderungen. Auch wenn sich der Versorgungsablauf im Grundsatz kaum von dem bei Alltagspatienten unterscheidet, gilt es hinsichtlich der Befundung und Analyse sportspezifische Aspekte zu berücksichtigen. Die hierzu notwendigen Kenntnisse über funktionelle Anatomie, Pathologie und Biomechanik sind Voraussetzung, um den individuellen Bedürfnissen der Athleten zu begegnen und Beeinträchtigungen in dem eng getakteten Wettkampfkalender durch Fehlversorgungen zu vermeiden. Ziel dieses Beitrags ist es daher, ausgehend von einem Überblick über den allgemeinen Versorgungsstandard, ausgewählte Besonderheiten in der sportspezifischen Analyse darzustellen und deren Implikationen für die Einlagenversorgung auch anhand von Fallbeispielen zu verdeutlichen.The provision of insoles in elite sports presents special challenges for orthopedic shoemakers. Although the supply process is essentially no different from that for everyday patients, it is important to consider important, sport-specific aspects with regard to the diagnosis and analysis. Knowledge of functional anatomy, pathology, and biomechanics is essential to meet the individual needs of athletes and avoid downtime in the tightly scheduled competition calendar due to incorrect treatments. The aim of this article is therefore to outline selected features of sports analysis based on an overview of the general standard of care and to highlight their implications for insole provision, using case examples.
Background. Gait and balance disorders in patients with idiopathic Parkinson’s disease (PD) lead to major mobility limitations. To counteract this, physical therapy such as gait, balance, or resistance training is applied. Integrative training methods, which combine these elements, could be particularly effective. Objective. The objective of this study is to evaluate and compare the effects of two integrative interventions on gait and balance of patients with PD. Methods. Twenty-six patients with PD received either resistance training in combination with gait training (gait resistance training, GRT) or resistance training in combination with balance training (stability resistance training, SRT) for six weeks. Gait and balance outcome parameters were assessed before, immediately after, and six weeks after the interventions. The primary outcome parameters were the functional reach test to evaluate balance and stride length to evaluate gait. Secondary outcomes included further gait analysis parameters, knee extension strength, the timed up and go test, and the six-minute walk test. Results. The functional reach test results were significantly better after the intervention in both groups. Stride length increased significantly only in the GRT group. Several further gait parameters and the six-minute walk test improved in the GRT group, and the increase in gait speed was significantly higher than in the SRT group. The SRT group performed better after the intervention regarding the timed up and go test and knee extension strength, the latter being significantly more improved than in the SRT group. At six-week follow-up, the improvement in functional reach was maintained in the SRT group. Conclusions. Integrative therapies, combining gait or balance training with resistance training, have specific positive effects in PD rehabilitation. More pronounced effects on gait parameters are achieved by GRT, while SRT has more impact on balance. Thus, the combination of both training methods might be particularly efficient in improving the mobility of PD patients.
With increasing age, gait changes often occur, leading to mobility problems and thus a higher risk of falling. Interest in training at home or at retirement homes has led to the development of “mobile treadmills.” A difference in treadmill surface length may influence walking parameters (i.e., step length) and therefore may affect muscle activation. This led to the question: Does the treadmill size affect the muscle activation, i.e., with the length of the walking surface. The study aimed to investigate the influence of treadmill size, i.e., length of the walking surface, on gait pattern and to determine differences in the amplitude of muscle activation using a participant-specific musculoskeletal model (AnyBody Technology A/S, Aalborg, Denmark). For a prospective, randomized study gait parameters were collected from 47 healthy participants (aged 50.19 ± 20.58 years) while walking on two different treadmills, a small mobile treadmill (walking surface length 100 cm) and a conventional treadmill (walking surface length 150 cm), at their preferred speed, 2 km/h, and 4 km/h. Muscle activation amplitude patterns were similar between treadmills (M. gastrocnemius medialis: rmean = 0.94, M. gastrocnemius lateralis: rmean = 0.92, M. gluteus medius rmean = 0.90, M. gluteus minimus rmean = 0.94). However, the gait analysis showed a decreased preferred velocity (p < 0.001, z = 4.54), reduced stride length (preferred velocity: p = 0.03, z = −2.17; 2 km/h: p = 0.36, z = 2.10; 4 km/h: p = 0.006, z = 2.76), shorter stride time (2 km/h: p < 0.001, z = 4.65; 4 km/h: p < 0.001, z = 4.15), and higher cadence (2 km/h: p < 0.001, z = −4.20; 4 km/h: p = 0.029, z = −2.18) on the mobile treadmill than on the conventional treadmill. Our observations suggest that the treadmill design (e.g., a 50 cm difference in walking surface length) may not influence muscle activity amplitude during walking. However, the design of the treadmill may influence gait characteristics (e.g., stride length, cadence) of walking.
Background: During total knee arthroplasty (TKA), one of the key alignment factors to pay attention to is the posterior tibial slope (PTS). The PTS clearly influences the kinematics of the knee joint but must be adapted to the coupling degree of the specific TKA design. So far, there is hardly any literature including clear recommendations for how surgeons should choose the PTS in a medial stabilized (MS) TKA. The aim of the present study is to investigate the effects of different degrees of PTS on femorotibial kinematics in MS TKA. Materials and Methods: An MS TKA was performed in seven fresh-frozen human specimens successively with 0°, 3°, and 6° of PTS. After each modification, weight-bearing deep knee flexion (30–130°) was performed, and femorotibial kinematics were analyzed. Results: A lateral femoral rollback was observed for all three PTS modifications. With an increasing PTS, the tibia was shifted more anteriorly on the lateral side (0° PTS anterior tibial translation −9.09 (±9.19) mm, 3° PTS anterior tibial translation −11.03 (±6.72) mm, 6° PTS anterior tibial translation 11.86 (±9.35) mm). No difference in the tibial rotation was found for the different PTS variants. All PTS variants resulted in internal rotation of the tibia during flexion. With a 3° PTS, the design-specific medial rotation point was achieved more accurately. Conclusions: According to our findings, we recommend a PTS of 3° when implanting the MS prosthesis used in this study.
Wear is an important factor in the long-term success of total knee arthroplasty (TKA). Therefore, wear testing methods have become standard in implant research and development. In the EU, these are based on two simulation concepts, which are defined in standards ISO 14243-1 and 14243-3, differentiated by the control mode—force-controlled or displacement-controlled. The aim of this study was to compare the mechanical stresses within the different ISO concepts using a finite element model (the newest displacement-controlled norm from 2014 compared with force-controlled). The in silico model showed strong correlation with the experimental data (r > 0.8). The adapted force-controlled ISO showed higher mechanical stress during the gait cycle, which also might lead to higher wear rates (14243-1 (2009): 11.15 MPa, 10.15 MPa and 9.16 MPa). The displacement-controlled ISO led to higher mechanical stress because of the constraint at the end of the stance phase (14243-3: 20.59 MPa and 17.19 MPa). Future studies should analyse different inlay designs within the same ISO standards to guarantee comparability.
The German Arthroplasty registry (EPRD) has shown that different prosthesis systems have different rates of secondary patellar resurfacing: four years after implantation, the posterior-stabilized (PS) Vega prosthesis has a 3.2% risk of secondary patellar resurfacing compared to the cruciate-retaining (CR) Columbus prosthesis at 1.0% (both Aesculap AG, Tuttlingen, Germany). We hypothesized that PS implants have increased retropatellar pressure and a decreased retropatellar contact area compared to a CR design, which may lead to an increased likelihood of secondary patellar resurfacing. Eight fresh frozen specimens (cohort 1) were tested with an established knee rig. In addition, a possible influence of the registry-based patient collective (cohort 2) was investigated. No significant differences were found in patient data–cohort 2-(sex, age). A generally lower number of PS system cases is noteworthy. No significant increased patella pressure could be detected with the PS design, but a lower contact area was observed (cohort 1). Lower quadriceps force (100°–130° flexion), increased anterior movement of the tibia (rollback), greater external tilt of the patella, and increasing facet pressure in the Vega PS design indicate a multifactorial cause for a higher rate of secondary resurfacing which was found in the EPRD patient cohort and might be related to the PS’ principle function.