An ultrabroad-band x-ray source, with photon energies from 10 keV to >1 MeV, based on a picosecond laserdriven plasma accelerator, is characterized and used to radiograph high-energy-density-science relevant targets. The measured yield of 10(12 )photons/shot is reaching the necessary photon yields to radiograph, in a single shot, high areal density objects and matter under extreme conditions. By focusing a short laser pulse (120 J, 1 ps) into a gas jet, a <100 mrad electron beam with energies up to 350 MeV and up to 70 nC of charge was produced by a combination of laser self-modulation instability and direct laser acceleration. A foil placed at the exit of the gas jet is used to convert part of the electron beam energy into x rays through inverse bremsstrahlung and/or inverse Compton scattering, generating a bright, broad-band, high-photon-energy beam. This beam is used to radiograph a gold half hohlraum with a high-density sphere inside with relevant characteristics for high-energy-density science and inertial confinement fusion.
Ultra-intense short-pulse lasers interacting with matter are capable of generating exceptionally bright secondary radiation sources. The short pulse duration (picoseconds to nanoseconds), small source size (sub-mm), and comparable high peak flux to conventional single particle sources make them an attractive source for radiography using a combination of particle species, known as multimodal imaging. Simultaneous x-ray and MeV neutron imaging of multi-material objects can yield unique advantages for material segmentation and identification within the full sample. Here, we present a concept for simultaneous single line-of-sight multimodal imaging using laser-driven simultaneous MeV neutrons and x rays. Radiography is performed using two simple optically coupled scintillators. Different shielding thicknesses are explored to demonstrate contrasting images that enable multi-material segmentation. Synthetic combined x-ray and neutron radiographs demonstrate the ability to resolve both the high-Z and low-Z material features within a test object for realistic x-ray and neutron spectra and flux ratios at existing and near-term laser facilities.
High intensity lasers (>1 x 1018 W/cm2) interacting with a plasma can accelerate a spectrum of electrons whose temperature can be several mega-electron volts. It has been shown experimentally that the efficiency of laser energy into this electron population is on the order of 10s of percent. There are many potential applications of laser driven sources including the acceleration of protons from a mechanism known as Target-Normal-Sheath-Acceleration and the subsequent generation of neutrons. One application is x-ray radiography. If the populations of MeV electrons are accelerated into a high-Z converter, MeV x-rays can be generated via bremsstrahlung [1].
Compound parabolic concentrator (CPC) targets are utilized at the National Ignition Facility Advanced Radiographic Capability (NIF-ARC) laser to enhance the acceleration of electrons and production of high energy photons, for laser durations of 10 ps and energies up to 2.4 kJ. A large enhancement of mean electron energy (>2 ×) and photon brightness (>10×) is found with CPC targets compared to flat targets. Using multiple diagnostic techniques at different spatial locations and scaling by gold activation spatial data, photon spectra are characterized for Ephoton=0.5–30 MeV. Beam width and pointing variations are given. The efficient production of MeV photons at Ilaser≈2×1018 W/cm2 with CPCs is observed, with doses of >10 rad in air at 1 m for Ephoton>0.5 MeV; these exceed those previously reported with laser-driven sources. Using this source, sub-mm resolution radiographs are generated through large areal density radiograph objects. These results are promising for the development of bright MeV x-ray and particle sources on Petawatt class laser systems.
A novel dual-energy fast neutron imaging technique is presented using short-pulse laser-driven neutron sources to leverage their inherent adaptive spectral control to enable 3D volume segmentation and reconstruction. Laser-accelerated ion beams incident onto secondary targets create directional, broadband, MeV-class neutrons. Synthetic radiographs are produced of multi-material objects using ion and neutron spectra derived from analytic and numerical models. It is demonstrated that neutron images generated from small changes to the neutron spectra, controlled by altering the initial laser conditions, are sufficient to isolate materials with differing attenuation coefficients. This is first demonstrated using a simplistic combinatorial isolation method and then by employing more advanced reconstruction algorithms to reduce artifacts and generate a segmentation volume of the constituent materials.
We report an increase in MeV energy bremsstrahlung x-ray production using compound parabolic concentrators (CPC) compared to flat solid targets during relativistic laser-plasma experiments on a 140 J, 150 fs laser system using an f/40 focusing optic. CPC enhanced targets show a >3× increase in high energy x-ray production over planar foil targets. This enhancement in x-ray energy spectra shows a direct improvement in the radiography of an image quality indicator (IQI) object with a 20 g/cm2 areal density.
We report on the increase in the accelerated electron number and energy using compound parabolic concentrator (CPC) targets from a short-pulse (∼150 fs), high-intensity (>10^{18} W/cm^{2}), and high-contrast (∼10^{8}) laser-solid interaction. We report on experimental measurements using CPC targets where the hot-electron temperature is enhanced up to ∼9 times when compared to planar targets. The temperature measured from the CPC target is 〈T_{e}〉=4.4±1.3 MeV. Using hydrodynamic and particle in cell simulations, we identify the primary source of this temperature enhancement is the intensity increase caused by the CPC geometry that focuses the laser, reducing the focal spot and therefore increasing the intensity of the laser-solid interaction, which is also consistent with analytic expectations for the geometrical focusing.
We present a new decomposition approach for dual-energy computed tomography (DECT) called SIRZ that provides precise and accurate material description, independent of the scanner, over diagnostic energy ranges (30 to 200 keV). System independence is achieved by explicitly including a scanner-specific spectral description in the decomposition method, and a new X-ray-relevant feature space. The feature space consists of electron density, ρe, and a new effective atomic number, Ze, which is based on published X-ray cross sections. Reference materials are used in conjunction with the system spectral response so that additional beam-hardening correction is not necessary. The technique is tested against other methods on DECT data of known specimens scanned by diverse spectra and systems. Uncertainties in accuracy and precision are less than 3% and 2% respectively for the (ρe, Ze) results compared to prior methods that are inaccurate and imprecise (over 9%).
The accuracy of density measurements and position resolution in flash (40 ns) radiography of thick objects with 24 Gev/c protons is investigated. A global model fit to step wedge data is shown to give a good description spanning the periodic table. The parameters obtained from the step wedge data are used to predict transmission through the French Test Object (FTO), a test object of nested spheres, to a precision better than 1%. Multiple trials have been used to show that the systematic errors are less than 2%. Absolute agreement between the average radiographic measurements of the density and the known density is 1%. Spatial resolution has been measured to be 200 μm at the center of the FTO. These data verify expectations of the benefits provided by high energy hadron radiography for thick objects.
As a part of a code validation study, we have compared radiographic simulations generated using the HADES code against experimental measurements of a set of common materials of known composition and density: graphite, Teflon, Delrin, magnesium, silicon, titanium, and water cylinders. HADES calculations show good agreement with radiograph measurements. Discrepancies between simulation and experimental data are analyzed. Sources of error and future model improvement are discussed.
Covert nuclear attack is one of the foremost threats facing the United States and is a primary focus of the War on Terror. The Domestic Nuclear Detection Office (DNDO), within the Department of Homeland Security (DHS), is chartered to develop, and improve domestic systems to detect and interdict smuggling for the illicit use of a nuclear explosive device, fissile material or radiologica1 material. The CAARS (Cargo Advanced Automated Radiography System) program is a major part of the DHS effort to enhance US security by harnessing cutting-edge technologies to detect radiological and nuclear threats at points of entry to the United States. DNDO has selected vendors to develop complete radiographic systems. It is crucial that the initial design and testing concepts for the systems be validated and compared prior to the substantial efforts to build and deploy prototypes and subsequent large-scale production. An important aspect of these systems is the scatter which interferes with imaging. Monte Carlo codes, such as MCNP (X-5 Monte Carlo Team, 2005 Revision) allow scatter to be calculatied, but these calculations are very time consuming. It would be useful to have a fast scatter estimation algorithm in a fast ray tracing code. We have been extending the HADES ray-tracing radiographic simulation code to model vendor systems in a flexible and quick fashion and to use this tool to study a variety of questions involving system performance and the comparative value of surrogates. To enable this work, HADES has been linked to the BRL-CAD library (BRL-CAD Open Source Project, 2010), in order to enable the inclusion of complex CAD geometries in simulations, scanner geometries have been implemented in HADES, and the novel detector responses have been included in HADES. A major extension of HADES which has been required by this effort is the inclusion of scatter in these radiographic simulations. Ray tracing codes generally do not easily allow the inclusion of scatter, because these codes define a source and a grid of detector pixels and only compute the attenuation along rays between these points. Scatter is an extremely complex set of processes which can involve rays which change directions many times between the source and detector. Scatter from outside the field of view of the imaging system, as well as within the field of view, can have an important role in image formation. In this report, we will describe how we implemented a treatment of scatter in HADES. We begin with a discussion of how we define scatter in Section 2, followed by a description of how single Compton scatter is now included in HADES in Section 3. In Section 4 we report a set of verification tests against MCNP and tests of how the technique scales with image size, number of scatters allowed and number of processors used in the calculations. In Section 5, we describe how we plan to extend this approach to other forms of scatter and conclude in Section 6. It should be emphasized that the purpose of this report is to show that a form of scatter has been implemented in HADES and has been verified against MCNP. Validation, the process of comparing simulation and experiment, is a future task.
We present the results of detailed nuclear shell model calculations of the spin-dependent elastic cross section for neutralinos scattering from Si and Ge. The calculations were performed in large model spaces which adequately describe the configuration mixing in these two nuclei. As tests of the computed nuclear wave functions, we have calculated several nuclear observables and compared them with the measured values and found good agreement. In the limit of zero momentum transfer, we find scattering matrix elements in agreement with previous estimates for Si but significantly different than previous work for Ge. A modest quenching, in accord with shell model studies of other heavy nuclei, has been included to bring agreement between the measured and calculated values of the magnetic moment for Ge. Even with this quenching, the calculated scattering rate is roughly a factor of 2 higher than the best previous estimates; without quenching, the rate is a factor of 4 higher. This implies a higher sensitivity for germanium dark matter detectors. We also investigate the role of finite momentum transfer upon the scattering response for both nuclei and find that this can significantly change the expected rates. We close with a brief discussion of the effects of some of the non-nuclear uncertainties upon the matrix elements.
Laser experiments, such as those planned at the National Ignition Facility (NIF) and the Omega facility, use small targets with the goal of studying high-energy density physics and inertial confinement fusion. One particular application is a target with layers whose density changes in a carefully designed gradient (from 0.2 to 1.2 g/cm3) for use in isentropic compression experiments (ICE). We are nondestructively determining the density of these layers using two X-ray microscopes. Because of the many interfaces that comprise the layers, a plethora of X-ray phase contrast fringes appear in the images, leading to many radiographic and tomographic artifacts which compromise the ability to infer the density of the layer. In this paper, we describe how we are attacking this problem with a variety of radiographic standards and through radiographic simulation using the HADES radiographic simulation code.
High energy density experiments, such as those planned at the National Ignition Facility (NIF), use mesoscale targets with the goals of studying high energy density physics, inertial confinement fusion, and the support of national security needs. Mesoscale targets are typically several millimeters in size and have complex micrometer-sized structures composed of high-density metals and low-density foams and ices. These targets are designed with exacting tolerances that are difficult to achieve at present. Deviation from these tolerances can result in compromise of experimental goals and thus it is necessary to determine as-built properties of these targets using NDE techniques. Radiography and computed tomography are being used to investigate these targets, but the mix between phase and absorption information is difficult to separate, making interpretation of results difficult. We have recently improved the HADES radiographic simulation code to include phase in simulations, as an aid for doing NDE on mesoscale targets. In this paper we report on how we extended HADES to incorporate phase effects, and compare simulations with a variety of experimental test results.
Livermore researchers have developed a suite of computational tools to locate regulatory elements in the published genome sequences of many different species, including frogs, fi sh, mice, and humans.As the article beginning on p. 4 describes, the tools provide a fast and reliable method to effi ciently analyze the massive amount of data emanating from public sequencing efforts.Researchers worldwide can access these analytical and visualization tools online.Biologists can test computed predictions using a variety of experimental approaches.The experimental results, in turn, help the Livermore team refi ne the programs to enhance their performance.
Digital x-ray radiography and computed tomography methods are commonly used to characterize mesoscale objects (mm size objects with {micro}m size features). However the ability of these methods to provide high spatial resolution images is dependent, in part, on object recovery algorithms that account for phase effects [1]. The objective of this work is the development and validation of algorithms to model phase-contrast effects observed in x-ray radiographic systems, and to use these algorithms for quantitative object recovery. This work has three distinct tasks. First, we are modifying HADES [2,3] to model x-ray phase contrast and are investigating whether multislice techniques within the object are needed to fully capture the physics seen in x-ray data. Second, we are developing object recovery approaches. Third, we are validating these simulations against x-ray systems using well-known objects. At the end of this R&D, we will have a set of validated x-ray forward modeling codes including the effects of phase and an understanding of the current object recovery methods limitations.
This Strategic Initiative (SI) will advance nondestructive characterization of mesoscale (millimeter-sized) objects--allowing micrometer resolution over the objects' entire volume. X-ray imaging will be developed that allows object characterization with materials that vary widely in composition, density, and geometry.
At Lawrence Livermore National Laboratory particular emphasis is being placed on the nondestructive characterization (NDC) of 'mesoscale' objects.[Martz and Albrecht 2003] We define mesoscale objects as objects that have mm extent with {micro}m features. Here we confine our discussions to x-ray imaging methods applicable to mesoscale object characterization. The goal is object recovery algorithms including phase to enable emerging high-spatial resolution x-ray imaging methods to ''see'' inside or image mesoscale-size materials and objects. To be successful our imaging characterization effort must be able to recover the object function to one micrometer or better spatial resolution over a few millimeters field-of-view with very high contrast.