Abstract Within the framework of the INFN-CSN5 PROVIDE experiment, we fabricated planar detectors by depositing 1-μm-thick films using radio-frequency magnetron sputtering (RF-MS). These films were grown on both commercial and in-house substrates featuring various interdigitated electrode (IDE) geometries on both rigid and flexible platforms. Our characterization revealed that key detector parameters — including an effective room-temperature resitivity ρ ≈ 10 7 Ω cm and a mobility-lifetime product μτ ≈ 2 × 10 -7 cm 2 /V, derived from a Hecht-expression best-fit under 450 nm UV LED irradiation, remained consistent regardless of the substrate type or electrode configuration. Furthermore, we measured a responsivity of approximately 0.2 A/W for optical powers up to at 450 nm. We also prototyped optimized, fully in-house detectors consisting of thin films grown by the Firenze Unit on flexible Kapton substrates, which were equipped with Cr/Au IDEs produced via lithography and thermal evaporation by the Bologna Unit. When exposed to a 300 ps UV (355 nm) laser pulse, these devices demonstrated a fast response with a 1 ns rise time and slew rates of up to 0.14 V/ns, depending on the applied bias. These performances, comparable to reference silicon photodiodes, will possibly open the way to a new class of high-speed thin-film radiation detectors. The results will be further exploited in the near future for advanced high-energy photon and particle detection.
Objective. Treatment planning in proton therapy requires an accurate estimation of stopping power ratio relative to water (SPR) maps. Presently, about 4% of patients submitted to radiotherapy treatments have metallic implants, which are responsible for an incorrect determination of SPRs in prostheses and surrounding regions. This study presents the first application of the proton computed tomography (pCT) technique, able to directly measure SPRs maps, on complex metallic implants. Approach. A homogeneous Ti6Al4V alloy sample, a set of metallic devices used for prostheses and an intra-vertebral titanium alloy implant have been inspected, by means of a prototype pCT system with a 5 × 20 cm 2 field-of-view (FoV) developed by INFN Firenze (Italy), under a proton beam at Trento Proton Therapy Centre (APSS, Trento, Italy). For comparison, a Multi Layer Ionization Chamber (MLIC) has been used to independently determine the SPR mean value of the Ti6Al4V alloy sample. Main Results. Tomographic reconstructions of all devices and materials have been performed and SPR maps have been obtained. All pCT images and profiles, even of metallic components, are characterized by negligible artifacts. The fine spatial resolution of our pCT system, about 0.7 lp mm −1 , allowed us to resolve details within a millimeter scale. The internal grid of the meshed cage as well as details of the screws’ head of the intra-vertebral titanium alloy implant are clearly visible. The SPR of the Ti6Al4V alloy sample measured with pCT, 3.14 ± 0.02, compares well with what was measured by MLIC: 3.17 ± 0.02. Significance. This study presents the first application of the pCT methodology to directly measure SPR maps of complex metal prostheses. The ability of pCT to correctly determine mean SPR values has been experimentally demonstrated. Furthermore, this technique was shown to reconstruct complex metal structures at the millimeter scale with negligible artifacts.
In this work the feasibility of a high responsive humidity sensor realized through a quartz crystal microbalance functionalized by nanolayers of indium oxide (In2O3) is proposed. The sensing material is deposited by magnetron sputtering method and manufactured in oxygen-free atmosphere, thus named In2O3-x. The humidity-sensing performance of the functionalized quartz sensor was investigated across various humidity levels by monitoring shifts in the quartz resonance frequency induced by absorbed water molecules on the sensing film surface. Appreciable results are observed concerning the humidity sensor response, that follows a linear pattern for humidity levels below approximately 50
Objective.Proton therapy administers a highly conformal dose to the tumour region, necessitating accurate prediction of the patient's 3D map of proton relative stopping power (RSP) compared to water. This remains challenging due to inaccuracies inherent in single-energy computed tomography (SECT) calibration. Recent advancements in spectral x-ray CT (xCT) and proton CT (pCT) have shown improved RSP estimation compared to traditional SECT methods. This study aims to provide the first comparison of the imaging and RSP estimation performance among dual-energy CT (DECT) and photon-counting CT (PCCT) scanners, and a pCT system prototype.Approach.Two phantoms were scanned with the three systems for their performance characterisation: a plastic phantom, filled with water and containing four plastic inserts and a wood insert, and a heterogeneous biological phantom, containing a formalin-stabilised bovine specimen. RSP maps were generated by converting CT numbers to RSP using a calibration based on low- and high-energy xCT images, while pCT utilised a distance-driven filtered back projection algorithm for RSP reconstruction. Spatial resolution, noise, and RSP accuracy were compared across the resulting images.Main results.All three systems exhibited similar spatial resolution of around 0.54 lp/mm for the plastic phantom. The PCCT images were less noisy than the DECT images at the same dose level. The lowest mean absolute percentage error (MAPE) of RSP,(0.28±0.07)%, was obtained with the pCT system, compared to MAPE values of(0.51±0.08)%and(0.80±0.08)%for the DECT- and PCCT-based methods, respectively. For the biological phantom, the xCT-based methods resulted in higher RSP values in most of the voxels compared to pCT.Significance.The pCT system yielded the most accurate estimation of RSP values for the plastic materials, and was thus used to benchmark the xCT calibration performance on the biological phantom. This study underlined the potential benefits and constraints of utilising such a novelex-vivophantom for inter-centre surveys in future.
Objective.To present and characterize a novel method for x-ray computed tomography (xCT) calibration in proton treatment planning, based on proton CT (pCT) measurements on biological phantoms.Approach.A pCT apparatus was used to perform direct measurements of 3D stopping power relative to water (SPR) maps on stabilized, biological phantoms. Two single-energy xCT calibration curves-i.e. tissue substitutes and stoichiometric-were compared to pCT data. Moreover, a new calibration method based on these data was proposed, and verified against intra- and inter-species variability, dependence on stabilization, beam-hardening conditions, and analysis procedures.Main results.Biological phantoms were verified to be stable in time, with a dependence on temperature conditions, especially in the fat region: (-2.5 0.5) HU °C-1. The pCT measurements were compared with standard xCT calibrations, revealing an average SPR discrepancy within ±1.60% for both fat and muscle regions. In the bone region the xCT calibrations overestimated the pCT-measured SPR of the phantom, with a maximum discrepancy of about +3%. As a result, a new cross-calibration curve was directly extracted from the pCT data. Overall, the SPR uncertainty margin associated with this curve was below 3%; fluctuations in the uncertainty values were observed across the HU range. Cross-calibration curves obtained with phantoms made of different animal species and anatomical parts were reproducible with SPR discrepancies within 3%. Moreover, the stabilization procedure did not affect the resulting curve within a 2.2% SPR deviation. Finally, the cross-calibration curve was affected by the beam-hardening conditions on xCTs, especially in the bone region, while dependencies below 2% resulted from the image registration procedure.Significance.Our results showed that pCT measurements on biological phantoms may provide an accurate method for the verification of current xCT calibrations and may represent a tool for the implementation of a new calibration method for proton treatment planning.
A novel prototype based on the combination of a multi-junction, high-efficiency photovoltaic (PV) module and a supercapacitor (SC) able to self-power a wireless sensor node (WSN) for outdoor air quality monitoring has been developed and tested. A PV module with about an 8 cm2 active area made of eight GaAs-based triple-junction solar cells with a nominal 29% efficiency was assembled and characterized under terrestrial clear-sky conditions. Energy is stored in a 4000 F/4.2 V supercapacitor with high energy capacity and a virtually infinite lifetime (104 cycles). The node power consumption was tailored to the typical power consumption of miniaturized, low-consumption NDIR CO2 sensors relying on an LED as the IR source. The charge/discharge cycles of the supercapacitor connected to the triple-junction PV module were measured under illumination with a Sun Simulator device at selected radiation intensities and different node duty cycles. Tests of the miniaturized prototype in different illumination conditions outdoors were carried out. A model was developed from the test outcomes to predict the maximum number of sensor samplings and data transmissions tolerated by the node, thus optimizing the WSN operating conditions to ensure its self-powering for years of outdoor deployment. The results show the self-powering ability of the WSN node over different insolation periods throughout the year, demonstrating its operation for a virtually unlimited lifetime without the need for battery substitution.
The exceptional optoelectronic properties and high radiation resistance of epitaxial silicon carbide make this material attractive for high-energy beam dosimetry and radiation monitoring, especially when strict requirements such as high signal-to-noise ratios, high time and spatial resolutions and low detectivity levels are required. A 4H-SiC Schottky diode has been characterized as a proton-flux-monitoring detector and dosimeter under proton beams for proton therapy. The diode was composed of an epitaxial film grown on 4H-SiC n+-type substrate equipped with a gold Schottky contact. The diode was embedded in a tissue-equivalent epoxy resin and then characterized in terms of capacitance vs. voltage (C-V) and current vs. voltage (I-V) characteristics in the dark in the range of 0–40 V. The dark currents at room temperature are in the order of 1 pA, while the doping and active thicknesses extracted from the C-V are 2.5 × 1015 cm−3 and 2–4 μm, respectively. Proton beam tests have been carried out at the Proton Therapy Center of the Trento Institute for Fundamental Physics and Applications (TIFPA-INFN). They have been carried out with energies and extraction currents of 83–220 MeV and 1–10 nA, respectively, as typical for proton therapy applications, corresponding to dose rates in the range of 5 mGy/s to 2.7 Gy/s. The I-V characteristics measured under proton beam irradiation at the lowest dose rate showed a typical diode photocurrent response and a signal-to-noise ratio well above 10. Investigations with null bias evidenced a very good performance in terms of the diode’s sensitivity, fast rise and decay times and response stability. The diode’s sensitivity was in agreement with the expected theoretical values, and its response was linear throughout the whole investigated dose rate range.
Introduction: This paper deals with the class of versatile semiconducting materials called perovskites, which have been deposited for the first time on flexible substrates and then tested for radiation detection monitoring applications. Methods: Lead halide inorganic perovskite, CsPbCl 3 , 0.4–1 μm-thick films have been grown on plastic flexible substrates equipped with interdigitated electrodes (IDEs) by magnetron sputtering at room temperature. Results: First measurements in realtime configuration are reported for a 1–µm thick prototype under proton beams with energy in the range 100–228 MeV and 1–10 nA extraction currents, of interest for protontherapy applications. Discussion: Experimental results evidence good performances of our sample as a real-time monitoring device. Current stability under UV and proton beam exposure has been tested in the range 0.1–120 s, as well as reproducibility under multiple exposures. The measured current signal proved to be linearly dependent on the extraction currents at a given proton energy. Linearity of the current signal of the device with proton fluxes was also proved within two order of magnitude range, about 10 7 –10 9 p/s. These promising results, when coupled with easyness of fabrication, low processing costs and high versatility of electrode configurations, all features characterizing the manufacturing process, put into evidence lead halide perovskites as promising candidates for real-time radiation detection in protontherapy.
Objective. This paper describes the procedure to calibrate the three-dimensional (3D) proton stopping power relative to water (SPR) maps measured by the proton computed tomography (pCT) apparatus of the Istituto Nazionale di Fisica Nucleare (INFN, Italy). Measurements performed on water phantoms are used to validate the method. The calibration allowed for achieving measurement accuracy and reproducibility to levels below 1%.Approach. The INFN pCT system is made of a silicon tracker for proton trajectory determination followed by a YAG:Ce calorimeter for energy measurement. To perform the calibration, the apparatus has been exposed to protons of energies ranging from 83 to 210 MeV. Using the tracker, a position-dependent calibration has been implemented to keep the energy response uniform across the calorimeter. Moreover, correction algorithms have been developed to reconstruct the proton energy when this is shared in more than one crystal and to consider the energy loss in the non-uniform apparatus material. To verify the calibration and its reproducibility, water phantoms have been imaged with the pCT system during two data-taking sessions.Main results. The energy resolution of the pCT calorimeter resulted to beσEE≅0.9%at 196.5 MeV. The average values of the water SPR in fiducial volumes of the control phantoms have been calculated to be 0.995±0.002. The image non-uniformities were below 1%. No appreciable variation of the SPR and uniformity values between the two data-taking sessions could be identified.Significance. This work demonstrates the accuracy and reproducibility of the calibration of the INFN pCT system at a level below 1%. Moreover, the uniformity of the energy response keeps the image artifacts at a low level even in the presence of calorimeter segmentation and tracker material non-uniformities. The implemented calibration technique allows the INFN-pCT system to face applications where the precision of the SPR 3D maps is of paramount importance.
Objective. The goal of this study was to assess the imaging performances of the pCT system developed in the framework of INFN-funded (Italian National Institute of Nuclear Physics) research projects. The spatial resolution, noise power spectrum (NPS) and RSP accuracy has been investigated, as a preliminary step to implement a new cross-calibration method for x-ray CT (xCT). Approach. The INFN pCT apparatus, made of four planes of silicon micro-strip detectors and a YAG:Ce scintillating calorimeter, reconstructs 3D RSP maps by a filtered-back projection algorithm. The imaging performances (i.e. spatial resolution, NPS and RSP accuracy) of the pCT system were assessed on a custom-made phantom, made of plastic materials with different densities ((0.66, 2.18) g cm(-3)). For comparison, the same phantom was acquired with a clinical xCT system. Main results. The spatial resolution analysis revealed the nonlinearity of the imaging system, showing different imaging responses in air or water phantom background. Applying the Hann filter in the pCT reconstruction, it was possible to investigate the imaging potential of the system. Matching the spatial resolution value of the xCT (0.54 lp mm(-1)) and acquiring both with the same dose level (11.6 mGy), the pCT appeared to be less noisy than xCT, with an RSP standard deviation of 0.0063. Concerning the RSP accuracy, the measured mean absolute percentage errors were (0.23+-0.09)% in air and (0.21+-0.07)% in water. Significance. The obtained performances confirm that the INFN pCT system provides a very accurate RSP estimation, appearing to be a feasible clinical tool for verification and correction of xCT calibration in proton treatment planning.
Halide perovskites are a novel class of semiconductors that have attracted great interest in recent decades due to their peculiar properties of interest for optoelectronics. In fact, their use ranges from the field of sensors and light emitters to ionizing radiation detectors. Since 2015, ionizing radiation detectors exploiting perovskite films as active media have been developed. Recently, it has also been demonstrated that such devices can be suitable for medical and diagnostic applications. This review collects most of the recent and innovative publications regarding solid-state devices for the detection of X-rays, neutrons, and protons based on perovskite thin and thick films in order to show that this type of material can be used to design a new generation of devices and sensors. Thin and thick films of halide perovskites are indeed excellent candidates for low-cost and large-area device applications, where the film morphology allows the implementation on flexible devices, which is a cutting-edge topic in the sensor sector.
The response of resistive In2O3−x sensing devices was investigated as a function of the NO2 concentration in different operative conditions. Sensing layers are 150 nm thick films manufactured by oxygen-free room temperature magnetron sputtering deposition. This technique allows for a facile and fast manufacturing process, at same time providing advantages in terms of gas sensing performances. The oxygen deficiency during growth provides high densities of oxygen vacancies, both on the surface, where they are favoring NO2 absorption reactions, and in the bulk, where they act as donors. This n-type doping allows for conveniently lowering the thin film resistivity, thus avoiding the sophisticated electronic readout required in the case of very high resistance sensing layers. The semiconductor layer was characterized in terms of morphology, composition and electronic properties. The sensor baseline resistance is in the order of kilohms and exhibits remarkable performances with respect to gas sensitivity. The sensor response to NO2 was studied experimentally both in oxygen-rich and oxygen-free atmospheres for different NO2 concentrations and working temperatures. Experimental tests revealed a response of 32%/ppm at 10 ppm NO2 and response times of approximately 2 min at an optimal working temperature of 200 °C. The obtained performance is in line with the requirements of a realistic application scenario, such as in plant condition monitoring.