Nanotherapy has recently emerged as an experimental treatment option for atherosclerosis. To fulfill its promise, robust noninvasive imaging approaches for subject selection and treatment evaluation are warranted. To that end, we present here a positron emission tomography (PET)-based method for quantification of liposomal nanoparticle uptake in the atherosclerotic vessel wall. We evaluated a modular procedure to label liposomal nanoparticles with the radioisotope zirconium-89 (89Zr). Their biodistribution and vessel wall targeting in a rabbit atherosclerosis model was evaluated up to 15 days after intravenous injection by PET/computed tomography (CT) and PET/magnetic resonance imaging (PET/MRI). Vascular permeability was assessed in vivo using three-dimensional dynamic contrast-enhanced MRI (3D DCE-MRI) and ex vivo using near-infrared fluorescence (NIRF) imaging. The 89Zr-radiolabeled liposomes displayed a biodistribution pattern typical of long-circulating nanoparticles. Importantly, they markedly accumulated in atherosclerotic lesions in the abdominal aorta, as evident on PET/MRI and confirmed by autoradiography, and this uptake moderately correlated with vascular permeability. The method presented herein facilitates the development of nanotherapy for atherosclerotic disease as it provides a tool to screen for nanoparticle targeting in individual subjects’ plaques.
Yttrium-90 (90Y) radioembolization involves the intra-arterial delivery of radioactive microspheres to treat hepatic malignancies. Though this therapy involves careful pre-treatment planning and imaging, little is known about the precise location of the microspheres once they are administered. Recently, there has been growing interest post-radioembolization imaging using positron-emission tomography (PET) for quantitative dosimetry and identifying lesions that may benefit from additional salvage therapy. In this study, we aim to measure the inter-center variability of 90Y PET measurements as measured on PET/MRI in preparation for a multi-institutional prospective phase I/II clinical trial.
OBJECTIVES The authors sought to develop combined positron emission tomography (PET) dynamic contrast-enhanced (DCE) magnetic resonance imaging (MRI) to quantify plaque inflammation, permeability, and burden to evaluate the efficacy of a leukotriene A4 hydrolase (LTA4H) inhibitor in a rabbit model of atherosclerosis. BACKGROUND Multimodality PET/MRI allows combining the quantification of atherosclerotic plaque inflammation, neovascularization, permeability, and burden by combined F-18-fluorodeoxyglucose (F-18-FDG) PET, DCE-MRI, and morphological MRI. The authors describe a novel, integrated PET-DCE/MRI protocol to noninvasively quantify these parameters in aortic plaques of a rabbit model of atherosclerosis. As proof-of-concept, the authors apply this protocol to assess the efficacy of the novel LTA4H inhibitor BI691751. METHODS New Zealand White male rabbits (N = 49) were imaged with integrated PET-DCE/MRI after atherosclerosis induction and 1 and 3 months after randomization into 3 groups: 1) placebo; 2) high-dose BI691751; and 3) low-dose BI691751. All animals were euthanized at the end of the study. RESULTS Among the several metrics that were quantified, only maximum standardized uptake value and target-tobackground ratio by F-18-FDG PET showed a modest, but significant, reduction in plaque inflammation in rabbits treated with low-dose BI691751 (p = 0.03), whereas no difference was detected in the high-fat diet and in the high-dose BI691751 groups. No differences in vessel wall area by MRI and area under the curve by DCE-MRI were detected in any of the groups. No differences in neovessel and macrophage density were found at the end of study among groups. CONCLUSIONS The authors present a comprehensive, integrated F-18-FDG PET and DCE-MRI imaging protocol to noninvasively quantify plaque inflammation, neovasculature, permeability, and burden in a rabbit model of atherosclerosis on a simultaneous PET/MRI scanner. A modest reduction was found in plaque inflammation by F-18-FDG PET in the group treated with a low dose of the LTA4H inhibitor BI691751. (C) 2018 by the American College of Cardiology Foundation.
OBJECTIVES:The authors sought to develop combined positron emission tomography (PET) dynamic contrast-enhanced (DCE) magnetic resonance imaging (MRI) to quantify plaque inflammation, permeability, and burden to evaluate the efficacy of a leukotriene A4 hydrolase (LTA4H) inhibitor in a rabbit model of atherosclerosis.BACKGROUND:Multimodality PET/MRI allows combining the quantification of atherosclerotic plaque inflammation, neovascularization, permeability, and burden by combined 18F-fluorodeoxyglucose (18F-FDG) PET, DCE-MRI, and morphological MRI. The authors describe a novel, integrated PET-DCE/MRI protocol to noninvasively quantify these parameters in aortic plaques of a rabbit model of atherosclerosis. As proof-of-concept, the authors apply this protocol to assess the efficacy of the novel LTA4H inhibitor BI691751.METHODS:New Zealand White male rabbits (N = 49) were imaged with integrated PET-DCE/MRI after atherosclerosis induction and 1 and 3 months after randomization into 3 groups: 1) placebo; 2) high-dose BI691751; and 3) low-dose BI691751. All animals were euthanized at the end of the study.RESULTS:Among the several metrics that were quantified, only maximum standardized uptake value and target-to-background ratio by 18F-FDG PET showed a modest, but significant, reduction in plaque inflammation in rabbits treated with low-dose BI691751 (p = 0.03), whereas no difference was detected in the high-fat diet and in the high-dose BI691751 groups. No differences in vessel wall area by MRI and area under the curve by DCE-MRI were detected in any of the groups. No differences in neovessel and macrophage density were found at the end of study among groups.CONCLUSIONS:The authors present a comprehensive, integrated 18F-FDG PET and DCE-MRI imaging protocol to noninvasively quantify plaque inflammation, neovasculature, permeability, and burden in a rabbit model of atherosclerosis on a simultaneous PET/MRI scanner. A modest reduction was found in plaque inflammation by 18F-FDG PET in the group treated with a low dose of the LTA4H inhibitor BI691751.
Errors in quantification of carotid positron emission tomography (PET) in simultaneous PET/magnetic resonance (PET/MR) imaging when not incorporating bone in MR-based attenuation correction (MRAC) maps, and possible solutions, remain to be fully explored. In this study, we demonstrated techniques to improve carotid vascular PET/MR quantification by adding a bone tissue compartment to MRAC maps and deriving continuous Dixon-based MRAC (MRACCD) maps. We demonstrated the feasibility of applying ultrashort echo time-based bone segmentation and generation of continuous Dixon MRAC to improve PET quantification on five subjects. We examined four different MRAC maps: system standard PET/MR MRAC map (air, lung, fat, soft tissue) (MRACPET/MR), standard PET/MR MRAC map with bone (air, lung, fat, soft tissue, bone) (MRACPET/MRUTE), MRACCD map (no bone) and continuous Dixon-based MRAC map with bone (MRACCDUTE). The same PET emission data was then reconstructed with each respective MRAC map and a CTAC map (PETPET/MR, PETPET/MRUTE, PETCD, PECDUTE) to assess effects of the different attenuation maps on PET quantification in the carotid arteries and neighboring tissues. Quantitative comparison of MRAC attenuation values for each method compared to CTAC showed small differences in the carotid arteries with UTE-based segmentation of bone included and/or continuous Dixon MRAC; however, there was very good correlation for all methods in the voxel-by-voxel comparison. ROI-based analysis showed a similar trend in the carotid arteries with the lowest correlation to PETCTAC being PETPETMR and the highest correlation to PETCTAC being PETCDUTE. We have demonstrated the feasibility of applying UTE-based segmentation and continuous Dixon MRAC maps to improve carotid PET/MR vascular quantification.
PURPOSE:Positron emission tomography (PET) imaging of yttrium-90 in the liver post radioembolization has been shown useful for personalized dosimetry calculations and evaluation of extrahepatic deposition. The purpose of this study was to quantify the benefits of several MR-based data correction approaches offered by using a combined PET/MR system to improve Y-90 PET imaging. In particular, the feasibility of motion and partial volume corrections were investigated in a controlled phantom study.METHODS:The ACR phantom was filled with an initial concentration of 8 GBq of Y-90 solution resulting in a contrast of 10:1 between the hot cylinders and the background. Y-90 PET motion correction through motion estimates from MR navigators was evaluated by using a custom-built motion stage that simulated realistic amplitudes of respiration-induced liver motion. Finally, the feasibility of an MR-based partial volume correction method was evaluated using a wavelet decomposition approach.RESULTS:Motion resulted in a large (∼40%) loss of contrast recovery for the 8 mm cylinder in the phantom, but was corrected for after MR-based motion correction was applied. Partial volume correction improved contrast recovery by 13% for the 8 mm cylinder.CONCLUSIONS:MR-based data correction improves Y-90 PET imaging on simultaneous PET/MR systems. Assessment of these methods must be studied further in the clinical setting.
Yttrium-90 (90Y) radioembolization involves the intra-arterial delivery of radioactive microspheres for treating liver tumors. Although primarily a β− emitter, 90Y occasionally emits positrons via internal pair production. There is growing interest in positron emission tomography (PET) imaging of these microspheres following radioembolization to localize and quantify their distribution. Due to the low abundance of positron emission (0.0032%), the PET images are highly sensitive to the parameters of iterative reconstruction algorithms used in clinical PET imaging. In this study, we aim to determine the optimal 90Y PET reconstruction parameters for PET/MRI that provide maximal activity recovery while maintaining a moderate noise level. We imaged an ACR phantom filled with 90Y chloride solution on two Siemens Biograph mMR scanners with a total activity of 1.00 GBq–7.43 GBq. Images were reconstructed with varying iteration number, post-reconstruction filter size, and scatter correction method. In addition, we evaluated the effects of incorporating point spread function (PSF) compensation as well as reducing the scan time and imaging off the central axis of the scanner in order to simulate realistic patient acquisition protocols as closely as possible. Recovery coefficients (RCs) for hot cylinders 8–25 mm in diameter reached near convergence with limited noise at 3 iterations, 21 subsets, 5 mm FWHM Gaussian post-reconstruction filter, use of PSF compensation, and absolute scatter correction across all scans. RCs increased by as much as 17% and noise decreased by as much as 29% when scan time duration was 30 min compared to only 15 min. Images acquired with the phantom placed 7–10 cm off the central axis of the scanner exhibited slightly reduced RCs, especially for the lowest activity scan. Although optimal reconstruction parameters with current reconstruction software were determined in this study, these parameters failed to achieve perfect count recovery, suggesting further investigation of 90Y PET imaging is required.
Yttrium-90 (90Y) radioembolization is a therapeutic procedure that delivers local radiation to hepatic tumors [1]. Clinically, patients undergo a 90Y Bremsstrahlung SPECT scan to determine if there was any extrahepatic deposition and, most importantly, to predict if the tumor is likely to respond to therapy based on the level of the delivered dose [2]. In addition, it is also possible to image and quantify the delivered 90Y dose by PET, which was shown to be superior to Bremsstrahlung SPECT in terms of spatial resolution and quantification accuracy [3]. Clinical SPECT and PET scanners are currently integrated with CT systems to enable localization as well as attenuation correction of the detected emission activity signal from the CT anatomical transmission signal [4]. However, clinical PET/CT studies have shown that the relative difference in dose between responding and non-responding lesions may be as low as 25%, thus demonstrating the importance of precise anatomical localization and high quantitative accuracy when assessing dose deposition [5]. Localization of the 90Y signal distribution in the liver can be challenging with PET/CT, mainly due to the poor soft tissue discrimination and limited motion tracking capabilities offered by CT.
The goal of this study was to develop and validate a noninvasive imaging tool to visualize the in vivo behavior of high-density lipoprotein (HDL) by using positron emission tomography (PET), with an emphasis on its plaque-targeting abilities. HDL is a natural nanoparticle that interacts with atherosclerotic plaque macrophages to facilitate reverse cholesterol transport. HDL-cholesterol concentration in blood is inversely associated with risk of coronary heart disease and remains one of the strongest independent predictors of incident cardiovascular events. Discoidal HDL nanoparticles were prepared by reconstitution of its components apolipoprotein A-I (apo A-I) and the phospholipid 1,2-dimyristoyl-sn-glycero-3-phosphocholine. For radiolabeling with zirconium-89 ( 89 Zr), the chelator deferoxamine B was introduced by conjugation to apo A-I or as a phospholipid-chelator (1,2-distearoyl-sn-glycero-3-phosphoethanolamine–deferoxamine B). Biodistribution and plaque targeting of radiolabeled HDL were studied in established murine, rabbit, and porcine atherosclerosis models by using PET combined with computed tomography (PET/CT) imaging or PET combined with magnetic resonance imaging. Ex vivo validation was conducted by radioactivity counting, autoradiography, and near-infrared fluorescence imaging. Flow cytometric assessment of cellular specificity in different tissues was performed in the murine model. We observed distinct pharmacokinetic profiles for the two 89 Zr-HDL nanoparticles. Both apo A-I- and phospholipid-labeled HDL mainly accumulated in the kidneys, liver, and spleen, with some marked quantitative differences in radioactivity uptake values. Radioactivity concentrations in rabbit atherosclerotic aortas were 3- to 4-fold higher than in control animals at 5 days’ post-injection for both 89 Zr-HDL nanoparticles. In the porcine model, increased accumulation of radioactivity was observed in lesions by using in vivo PET imaging. Irrespective of the radiolabel’s location, HDL nanoparticles were able to preferentially target plaque macrophages and monocytes. 89 Zr labeling of HDL allows study of its in vivo behavior by using noninvasive PET imaging, including visualization of its accumulation in advanced atherosclerotic lesions. The different labeling strategies provide insight on the pharmacokinetics and biodistribution of HDL’s main components (i.e., phospholipids, apo A-I).
OBJECTIVES:The goal of this study was to develop and validate a noninvasive imaging tool to visualize the in vivo behavior of high-density lipoprotein (HDL) by using positron emission tomography (PET), with an emphasis on its plaque-targeting abilities. BACKGROUND:HDL is a natural nanoparticle that interacts with atherosclerotic plaque macrophages to facilitate reverse cholesterol transport. HDL-cholesterol concentration in blood is inversely associated with risk of coronary heart disease and remains one of the strongest independent predictors of incident cardiovascular events. METHODS:Discoidal HDL nanoparticles were prepared by reconstitution of its components apolipoprotein A-I (apo A-I) and the phospholipid 1,2-dimyristoyl-sn-glycero-3-phosphocholine. For radiolabeling with zirconium-89 ((89)Zr), the chelator deferoxamine B was introduced by conjugation to apo A-I or as a phospholipid-chelator (1,2-distearoyl-sn-glycero-3-phosphoethanolamine-deferoxamine B). Biodistribution and plaque targeting of radiolabeled HDL were studied in established murine, rabbit, and porcine atherosclerosis models by using PET combined with computed tomography (PET/CT) imaging or PET combined with magnetic resonance imaging. Ex vivo validation was conducted by radioactivity counting, autoradiography, and near-infrared fluorescence imaging. Flow cytometric assessment of cellular specificity in different tissues was performed in the murine model. RESULTS:We observed distinct pharmacokinetic profiles for the two (89)Zr-HDL nanoparticles. Both apo A-I- and phospholipid-labeled HDL mainly accumulated in the kidneys, liver, and spleen, with some marked quantitative differences in radioactivity uptake values. Radioactivity concentrations in rabbit atherosclerotic aortas were 3- to 4-fold higher than in control animals at 5 days' post-injection for both (89)Zr-HDL nanoparticles. In the porcine model, increased accumulation of radioactivity was observed in lesions by using in vivo PET imaging. Irrespective of the radiolabel's location, HDL nanoparticles were able to preferentially target plaque macrophages and monocytes. CONCLUSIONS:(89)Zr labeling of HDL allows study of its in vivo behavior by using noninvasive PET imaging, including visualization of its accumulation in advanced atherosclerotic lesions. The different labeling strategies provide insight on the pharmacokinetics and biodistribution of HDL's main components (i.e., phospholipids, apo A-I).
With the introduction of clinical PET/magnetic resonance (MR) systems, novel attenuation correction methods are needed, as there are no direct MR methods to measure the attenuation of the objects in the field of view (FOV). A unique challenge for PET/MR attenuation correction is that coils for MR data acquisition are located in the FOV of the PET camera and could induce significant quantitative errors. In this review, current methods and techniques to correct for the attenuation of a variety of coils are summarized and evaluated.
The purpose of this study was to develop and validate low dose (18)F-FDG-PET acquisition protocols for detection of inflamed carotid plaques specifically for simultaneous PET/MR imaging. The hypothesis was that increasing the duration of the PET acquisition to match that of the MR acquisition might allow for the use of lower levels of the radiotracer, while preserving quantification and image quality. Seven subjects were scanned twice at least one week apart on a simultaneous PET/MR scanner using either the standard clinical dose of (18)F-FDG (373 ± 63 MBq) for 8 minutes or a low dose (93 ± 17 MBq) for 75 minutes. A maximum absolute percent difference of only 4.17% and 7.49% in the left and right carotid TBR was found between the standard dose and four time points of the low dose acquisitions (8, 24, 45, 75 minutes). Only the 8-minute low dose PET data was significantly different in terms of SNR (P = 0.009; % difference = -51%) and qualitative image quality evaluation (P = 0.0005; % difference = -45%). Our preliminary findings indicate that up to 75% reduction of the clinical standard (18)F-FDG dose could be achieved using the proposed acquisition scheme while maintaining accurate quantification and SNR.
1283 Objectives The aim of our study was to optimize reconstruction parameters for PET/MRI post-therapy Y-90 imaging using PET/CT as a standard. Methods In a continuing study after selective internal radiation therapy (SIRT) with Y-90 microspheres, patients were imaged on a 4R, 40 slice PET/CT system (Siemens mCT). The low mA, non-diagnostic CT images were used for attenuation correction and localization of the Y-90 microspheres in the PET/CT studies. The acquisition time was 15 min. Immediately after PET/CT study, in an adjacent room a PET/MRI study was done on a Siemens mMR system. The acquisition time was 20 min, and attenuation correction was done using the scanner standard 4 segment MR based attenuation map. In both studies, the Na-22 isotope was selected, because neither system has Y-90 in their database. The data were reconstructed using the vendor’s reconstruction software and were transferred to a common platform where the PET/MRI and PET/CT Y-90 microspheres liver distributions were visually compared. Results PET images for the PET/CT system were reconstructed according to QUEST recommendations, 2 iterations 21 subsets (2i21s) and 5mm Gaussian smoothing. PET images from the PET/MRI system were reconstructed using different number of iteration steps and different Gaussian smoothing. However, the number of subsets was fixed to 21. In a visual comparison we concluded that the PET images from PET/MRI system, which has the best qualitative match with corresponding PET images from PET/CT system are also the ones reconstructed with 2i21s and 5mm Gaussian smooth, although other combinations also were close match, like 3i21s and 8mm Gaussian smooth. Conclusions In liver SIRT with Y-90 microspheres, the final administrated Y-90 distribution can be adequately imaged by either PET/CT or PET/MRI state-of-the-art system. The distributions of Y-90 microspheres obtained from PET/MRI and PET/CT in post-therapy studies were very similar.
The purpose of the study was to evaluate the effect of attenuation of MR coils on quantitative carotid PET/MR exams. Additionally, an automated attenuation correction method for flexible carotid MR coils was developed and evaluated. The attenuation of the carotid coil was measured by imaging a uniform water phantom injected with 37 MBq of 18F-FDG in a combined PET/MR scanner for 24 min with and without the coil. In the same session, an ultra-short echo time (UTE) image of the coil on top of the phantom was acquired. Using a combination of rigid and non-rigid registration, a CT-based attenuation map was registered to the UTE image of the coil for attenuation and scatter correction. After phantom validation, the effect of the carotid coil attenuation and the attenuation correction method were evaluated in five subjects. Phantom studies indicated that the overall loss of PET counts due to the coil was 6.3% with local region-of-interest (ROI) errors reaching up to 18.8%. Our registration method to correct for attenuation from the coil decreased the global error and local error (ROI) to 0.8% and 3.8%, respectively. The proposed registration method accurately captured the location and shape of the coil with a maximum spatial error of 2.6 mm. Quantitative analysis in human studies correlated with the phantom findings, but was dependent on the size of the ROI used in the analysis. MR coils result in significant error in PET quantification and thus attenuation correction is needed. The proposed strategy provides an operator-free method for attenuation and scatter correction for a flexible MRI carotid surface coil for routine clinical use.
To evaluate the effect of surface coils for carotid MR imaging on PET quantification in a clinical simultaneous whole-body PET/MR scanner. A cylindrical phantom was filled with a homogeneous 2L water-FDG mixture at a starting dose of 301.2MBq. Clinical PET/MR and PET/CT systems were used to acquire PET-data without a coil (reference standard) and with two carotid MRI coils (Siemens Special Purpose 8-Channel and Machnet 4-Channel Phased Array). PET-signal attenuation was evaluated with Osirix using 51 (PET/MR) and 37 (PET/CT) circular ROIs. Mean and maximum standardized uptake values (SUVs) were quantified for each ROI. Furthermore, SUVs of PET/MR and PET/CT were compared. For validation, a patient was scanned with an injected dose of 407.7MBq on both a PET/CT and a PET/MR system without a coil and with both coils. PET/MR underestimations were -2.2% (Siemens) and -7.8% (Machnet) for SUVmean, and -1.2% (Siemens) and -3.3% (Machnet) for SUVmax, respectively. For PET/CT, underestimations were -1.3% (Siemens) and -1.4% (Machnet) for SUVmean and -0.5% (both Siemens and Machnet) for SUVmax, respectively using no coil data as reference. Except for PET/CT SUVmax values all differences were significant. SUVs differed significantly between PET/MR and PET/CT with SUVmean values of 0.51-0.55 for PET/MR and 0.68-0.69 for PET/CT, respectively. The patient examination showed that median SUVmean values measured in the carotid arteries decreased from 0.97 without a coil to 0.96 (Siemens) and 0.88 (Machnet). Carotid surface coils do affect attenuation correction in both PET/MR and PET/CT imaging. Furthermore, SUVs differed significantly between PET/MR and PET/CT.
Current PET/MR systems employ segmentation of MR images and subsequent assignment of empirical attenuation coefficients for quantitative PET reconstruction. In this study we examine the differences in the quantification of (18)F-FDG uptake in the carotid arteries between PET/MR and PET/CT scanners. Five comparisons were performed to asses differences in PET quantification: i) PET/MR MR-based AC (MRAC) versus PET/MR CTAC, ii) PET/MR MRAC versus PET/CT, iii) PET/MR MRAC with carotid coil versus PET/MR MRAC without coil, iv) PET/MR MRAC scan 2 versus PET/MR MRAC scan 1, and v) PET/MR CTAC versus PET/CT. Standardized uptakes values (SUV) mean and SUV maximum were calculated for six regions-of-interests: left and right carotid arteries, left and right lungs, spine and muscle. Pearson's Correlation and Bland-Altman plots were used to compare SUV mean and maximum within each ROI of each patient. PET/MR emission data reconstructed with MRAC versus PET/MR emission data reconstructed with CTAC had percent differences of SUV mean ranging from -2.0% (Absolute Difference, -0.02) to 7.4% (absolute difference, 0.06). Percent differences within the carotid arteries proved to correlate well with differences of SUV mean of 5.4% (Absolute Difference, 0.07) in the left carotid and 2.7% (Absolute Difference, 0.03) in the right carotid. Pearson's correlation and Bland-Altman of PET/MR with MRAC versus PET/MR with CTAC showed high correlation between SUV mean (R(2)=0.80, mean difference 0.03 ± 0.18 SUV, p=0.3382), demonstrating excellent correlation within ROIs analyzed. The results of this study support the use of (18)F-FDG PET/MR for quantitative measure of inflammation in the carotid arteries.
Simultaneous MR/PET scanners allow for the exploration and development of novel PVE correction techniques without the challenges of coregistration of MR and PET. The development of a wavelet-based PVE correction method, to improve PET quantification, has proven successful in brain PET.2 We report here the first attempt to apply these methods to simultaneous MR/PET imaging of the carotid arteries. The American College of Radiology (ACR) phantom was injected with 18F-FDG for a lesion to background ratio of 2.5. As per ACR protocol, hot cylinders (“lesions”) were injected with 30.71MBq and the phantom background was injected with 12.95MBq. The ACR phantom was then scanned on the Siemens mCT and Siemens Biograph mMR. One patient was injected with 446.6MBq of 18F-FDG and scanned after a circulation time of 90 minutes on the Siemens Biograph mMR. The MR/PET acquisition consisted of the system standard Dixon attenuation correction sequence. Wavelet-based PVE correction was performed to incorporate high frequency wavelet information from MR images into PET images to improve resolution. Qualitative and quantitative uptake parameters where measured to assess the efficacy of the method used. Qualitative comparisons in the ACR phantom and a patient without and with wavelet-based PVE correction demonstrated slight improvement in image quality. Line profiles drawn through the 8mm cylinder and 25mm cylinder and demonstrated an improvement of quantification in the wavelet-based PVE corrected PET image compared to the non-corrected PET image. Standard deviation of SUV before and after PVE correction in the left and right carotid arteries was decreased demonstrating partial volume effect correction. The technique applied here demonstrated an improvement in both resolution and quantification in the phantom and the patient. These results demonstrate the feasibility of wavelet-based PVE correction to provide improved quantification for MR/PET in the carotid arteries.