A sufficient oxygen supply of the fetus is necessary for a proper development of the organs. Transabdominal fetal pulse oximetry is a method that allows to measure the oxygenation of the fetal blood non-invasively by placing the light sources and photodetectors on the belly of the pregnant woman. The shape of the measured fetal pulse wave is needed to extract parameters for the estimation of the oxygen saturation. This work presents an extension of our previously presented signal processing strategy that allows to extract an average shape of the fetal pulse wave from noisy mixed photoplethysmograms (PPG) with dominating maternal and very weak fetal signal components. An adaptive noise canceller and a comb filter are used to suppress the maternal component. The quality of the resulting fetal signal is sufficient to identify single pulse waves in time domain. Further processing demonstrates the extraction of the mean shape of a single fetal pulse wave by synchronous averaging of several detected pulses. The method is evaluated with different datasets of several simulated and synthetic signals measured with a tissue mimicking phantom. The feasibility of the approach is demonstrated by preparing the mixed PPGs to perform fetal pulse oximetry in future studies. However, clinical measurements are needed to finally evaluate the proposed system beyond synthetic datasets.
The fetal pulse curve can be captured by placing light sources and detectors on the belly of a pregnant woman. Following the principle of reflection pulse oximetry, the light emitted into the abdomen is modulated by pulsing maternal and fetal arteries. The acquired signal is a mixture of a weak fetal and a dominating maternal photoplethysmogram (PPG). A first step towards estimation of the fetal oxygen level is the reconstruction of the purely fetal signal in time domain. As already shown in a former work, comb filters are well suited for the task, in case the fetal heart rate is known. In this work we extend the method by utilizing an adaptive noise canceller (ANC) to estimate the fetal pulse rate for comb filter design. Synthetic test signals with constant and time variable pulse rates are generated in order to achieve reproducible conditions. The ANC is fed by the mixed PPG and the maternal reference signal to reduce the dominant maternal components. The fetal pulse rate is computed by evaluating peaks in the resulting signal in time and frequency domain. The findings are used for comb filter design. It is shown that the extraction of the fetal pulse curve from the synthetic mixed PPGs by using the proposed strategy is promising. Clinical test measurements are the next step for evaluation.
Non-invasive fetal pulse oximetry is the application of reflection pulse oximetry to the abdomen of a pregnant woman. Light sources and detectors areplaced on the belly. Emitted photons travel through maternal and fetal tissue and back to the detectors. The captured photoplethysmogram (PPG) is a complex mixture of the maternal and fetal pulse curve. A purely fetal PPG in time domain is needed to estimate the oxygen level of the unborn child. In this work we describe the application of comb filters to separate the fetalfrom the maternal signal. Finite element simulations and phantom measurements are utilized to generate and measure synthetic signals at different heart rates and noise levels. Comb filters with peak frequencies matched to the fetal heart rate are applied to the mixed PPGs. The filtered signals prove that the extraction of the fetal signal is sufficient even at a distance between the maternal and the fetal signal magnitudes of around 80 dB. The resulting signal quality is sufficient for beat to beat analysis and feature extraction in the time domain. We conclude that comb filtering is a suitable signal separation method for non-invasive fetal pulse oximetry.
BACKGROUND:Our aim is to introduce a method to enhance the design process of microelectrode array (MEA) based electric bioimpedance measurement systems for improved detection and viability assessment of living cells and tissues. We propose the application of electromagnetic lead field theory and reciprocity for MEA design and measurement result interpretation. Further, we simulated impedance spectroscopy (IS) with two- and four-electrode setups and a biological cell to illustrate the tool in the assessment of the capabilities of given MEA electrode constellations for detecting cells on or in the vicinity of the microelectrodes.RESULTS:The results show the power of the lead field theory in electromagnetic simulations of cell-microelectrode systems depicting the fundamental differences of two- and four-electrode IS measurement configurations to detect cells. Accordingly, the use in MEA system design is demonstrated by assessing the differences between the two- and four-electrode IS configurations. Further, our results show how cells affect the lead fields in these MEA system, and how we can utilize the differences of the two- and four-electrode setups in cell detection. The COMSOL simulator model is provided freely in public domain as open source.CONCLUSIONS:Lead field theory can be successfully applied in MEA design for the IS based assessment of biological cells providing the necessary visualization and insight for MEA design. The proposed method is expected to enhance the design and usability of automated cell and tissue manipulation systems required for bioreactors, which are intended for the automated production of cell and tissue grafts for medical purposes. MEA systems are also intended for toxicology to assess the effects of chemicals on living cells. Our results demonstrate that lead field concept is expected to enhance also the development of such methods and devices.
Transabdominal fetal pulse oximetry is an approach to measure oxygen saturation of the unborn child non-invasively. The principle of pulse oximetry is applied to the abdomen of a pregnant woman, such that the measured signal includes both, the maternal and the fetal pulse curve. One of the major challenges is to extract the shape of the fetal pulse curve from the mixed signal for computation of the oxygen saturation. In this paper we analyze the principle kind of connection of the fetal and maternal pulse curves in the measured signal. A time varying finite element model is used to rebuild the basic measurement environment, including a bulk tissue and two independently pulsing arteries to model the fetal and maternal blood circuit. The distribution of the light fluence rate in the model is computed by applying diffusion equation. From the detectors we extracted the time dependent fluence rate and analyzed the signal regarding its components. The frequency spectra of the signals show peaks at the fetal and maternal basic frequencies. Additional signal components are visible in the spectra, indicating multiplicative coupling of the fetal and maternal pulse curves. We conclude that the underlying signal model of algorithms for robust extraction of the shape of the fetal pulse curve, have to consider additive and multiplicative signal coupling.
Transabdominal fetal pulse oximetry is a method to estimate the state of oxygenation of a fetus in-utero, utilizing the principle of reflection pulse oximetry. The extraction of fetal related information from a mixed fetal-maternal signal is elementary. Minimizing the ratio of purely maternal components of the signal at the detector side obviously facilitates signal separation. In this paper we analyze the influence of tissue geometries to the fluence composition at the surface of the abdomen. Monte-Carlo method is used to compute photon propagation in spherical layered tissue models. Spatial fluence distributions at the surface of the models are visualized and discussed. Our results show the characteristic effects of the distance between the fetus and the surface and the radius of the abdomen to the fluence composition at the detector. Further, the simulations indicate suitable source-detector configurations considering various anatomical conditions. We conclude that an adoption of the source-detector configuration to the individual tissue geometry at hand is necessary to achieve a proper signal composition and quality. Utilizing simulations for sensor design enhances the understanding of photon distributions in complex tissue geometries and supports a successful implementation of transabdominal fetal pulse oximetry.
Monitoring the oxygen saturation of an unborn child is an invasive procedure, so far. Transabdominal fetal pulse oximetry is a promising method under research, used to estimate the oxygen saturation of a fetus noninvasively. Due to the nature of the method, the fetal information needs to be extracted from a mixed signal. To properly evaluate signal processing algorithms, a phantom modeling fetal and maternal blood circuits and tissue layers is necessary. This paper presents an improved hardware concept for an artificial vascular system, utilizing an FPGA based CompactRIO System from National Instruments. The experimental model to simulate the maternal and fetal blood pressure curve consists of two identical hydraulic circuits. Each of these circuits consists of a pre-pressure system and an artificial vascular system. Pulse curves are generated by proportional valves, separating these two systems. The dilation of the fetal and maternal artificial vessels in tissue substitutes is measured by transmissive and reflective photoplethysmography. The measurement results from the pressure sensors and the transmissive optical sensors are visualized to show the functionality of the pulse generating systems. The trigger frequency for the maternal valve was set to 1 per second, the fetal valve was actuated at 0.7 per second for validation. The reflective curve, capturing pulsations of the fetal and maternal circuit, was obtained with a high power LED (905 nm) as light source. The results show that the system generates pulse curves, similar to its physiological equivalent. Further, the acquired reflective optical signal is modulated by the alternating diameter of the tubes of both circuits, allowing for tests of signal processing algorithms.
Transabdominal fetal pulse oximetry is a method to monitor the oxygen supply of the unborn child non-invasively. Due to the measurement setup, the received signal of the detector is composed of photons coding purely maternal and photons coding mixed fetal-maternal information. To analyze the wellbeing of the fetus, the fetal signal is extracted from the mixed component. In this paper we assess source-detector configurations, such that the mixed fetal-maternal components of the acquired signals are maximized. Monte-Carlo method is used to simulate light propagation and photon distribution in tissue. We use a plane layer and a spherical layer geometry to model the abdomen of a pregnant woman. From the simulations we extracted the fluence at the detector side for several source-detector distances and analyzed the ratio of the mixed fluence component to total fluence. Our simulations showed that the power of the mixed component depends on the source-detector distance as expected. Further we were able to visualize hot spot areas in the spherical layer model where the mixed fluence ratio reaches the highest level. The results are of high importance for sensor design considering signal composition and quality for non-invasive fetal pulse oximetry.