The effect of mandibular advancement device therapy on daytime sleepiness remains unclear. Here, we evaluate the effect of a mandibular advancement device on daytime sleepiness using the Karolinska Sleepiness Scale. We randomized 88 snoring patients with an apnea-hypopnea index < 30 and daytime sleepiness to a mandibular advancement device or a sham device for four months. The Karolinska Sleepiness Scale, which measures grades of sleepiness from 1 (very alert) to 9 (very sleepy), was used for seven consecutive days, four times each day. The results were analyzed with quantile regression at quartiles controlling for baseline, age, body mass index (kg/m2), sex, apnea-hypopnea index, and full-time work. The Karolinska Sleepiness Scale score was lower with the mandibular advancement device than with the sham device at specific time intervals. The positive effect of mandibular advancement device therapy occurred at wake up and before lunch during the whole week and before lunch on weekdays at the middle quartile. The adjusted differences between the interventions favored mandibular advancement device therapy by almost one unit and normalized the Karolinska Sleepiness Scale scores at wake up and before lunch. In addition, there were positive effects of mandibular advancement device therapy before dinner at the highest quartile during the whole week, on weekdays, and on the weekend. Mandibular advancement devices used for snoring and sleep apnea reduce daytime sleepiness, particularly at wake up and before lunch, but provide some benefit before dinner.
Objective:Discomfort has been related to the poor acceptance of a mandibular advancement device (MAD) in patients with obstructive sleep apnea. The present study compared severe initial side effects between a smaller and a larger degree of mandibular advancement in patients with a good protrusive capacity.Methods:Consecutive patients with obstructive sleep apnea and a good protrusive capacity (≥8 mm) were randomized to start treatment with the mandible advanced by either 70% of maximum protrusion (Adv70%) or by 4 mm (Adv4mm) in a pilot study with a parallel design. The main outcome was tenderness or pain in the teeth or jaws using a 0-10 visual analogue scale (VAS) (from "not at all" to "very extensive") or excluded use because of side effects during the first week of treatment. Secondary outcomes included salivation problems and bite changes.Results:Eighteen patients were randomly selected and 17 patients fulfilled the study protocol. Four patients in the Adv70% group and none in the Adv4mm group reported severe tenderness or pain (VAS ≥7) on five or more of the seven days (p=0.03). The degree of mandibular advancement measured in millimeters correlated with the number of days with severe side effects, r=0.64 (p=0.006). The secondary side effects were minor.Conclusion:Starting MAD treatment with 70% mandibular advancement was related to more severe side effects during the first week of treatment compared with a smaller fixed millimeter value in patients with a good protrusive capacity in this pilot study.
There is now widespread recognition within the world of sleep medicine of the increasing importance of dental sleep medicine and, in particular, the role of oral appliance therapy (OAT) in the management of adults with obstructive sleep apnoea (OSA). For the purpose of this review, the term OAT refers to a custom-made intra-oral appliance, which acts to posture the mandible in a forward and downward direction, away from its natural resting position. Whilst nasally applied continuous positive airway pressure remains the “gold standard” in nonsurgical OSA management, OAT remains the recognised alternative treatment. This review of OAT aims to provide an evidence-based update on our current understanding of their mode of action, exploring the potential anatomical and physiological impact of their use in preventing collapse of the upper airway; the current clinical practice guidelines, including the recently published National Institute of Clinical Excellence 2021 guidance, in conjunction with the American Academy of Sleep Medicine and American Academy of Dental Sleep Medicine; optimal design features, comparing the role of custom-made versus noncustom OAT devices and the importance of titration in achieving a dose-dependent effect; patient predictors, preference and adherence to OAT; its impact on a range of both patient- and clinician-centred health outcomes, with a comparison with CPAP; the limitations and side-effects of providing OAT; and, finally, a look at future considerations to help optimise the delivery and outcomes of OAT.
Obstructive sleep apnoea is a challenging medical problem due to its prevalence, its impact on quality of life and performance in school and professionally, the implications for risk of accidents, and comorbidities and mortality. Current research has carved out a broad spectrum of clinical phenotypes and defined major pathophysiological components. These findings point to the concept of personalised therapy, oriented on both the distinct clinical presentation and the most relevant pathophysiology in the individual patient. This leads to questions of whether sufficient therapeutic options other than positive airway pressure (PAP) alone are available, for which patients they may be useful, if there are specific indications for single or combined treatment, and whether there is solid scientific evidence for recommendations. This review describes our knowledge on PAP and non-PAP therapies to address upper airway collapsibility, muscle responsiveness, arousability and respiratory drive. The spectrum is broad and heterogeneous, including technical and pharmaceutical options already in clinical use or at an advanced experimental stage. Although there is an obvious need for more research on single or combined therapies, the available data demonstrate the variety of effective options, which should replace the unidirectional focus on PAP therapy.
Guidelines for the evaluation and management of sleep disorders from national societies provide recommendations that may be regionally appropriate but may not always be practical or relevant in other parts of the world. A task force of experts from the World Sleep Society's (WSS) International Sleep Medicine Guidelines Committee and Sleep and Breathing Disorders Taskforce reviewed the American Academy of Sleep Medicine's Clinical Practice Guideline on the Treatment of Adult Obstructive Sleep Apnea (OSA) with Positive Airway Pressure with respect to its relevance and applicability to the practice of sleep medicine by sleep specialists in various regions of the world. To improve the evaluation of the guideline, surveys were sent by the senior author and the WSS to approximately 800 sleep doctors around the world to query the availability of OSA treatments in their respective region. The task force and the WSS guidelines committee endorsed the AASM's CPAP guidelines with respect to the indications for PAP therapy, utilization of different PAP modalities, and concurrent strategies to improve outcomes, noting appropriate caveats for universal applicability.
Treatment of obstructive sleep apnoea (OSA) in adults is evolving, as new therapies have been explored and introduced in clinical practice, while other approaches have been refined or reconsidered. In this European Respiratory Society (ERS) guideline on non-continuous positive airway pressure (CPAP) therapies for OSA, we present recommendations determined by a systematic review of the literature. It is an update of the 2011 ERS statement on non-CPAP therapies, advanced into a clinical guideline. A multidisciplinary group of experts, including pulmonary, surgical, dentistry and ear–nose–throat specialists, methodologists and patient representatives considered the most relevant clinical questions (for both clinicians and patients) relating to the management of OSA. Eight key clinical questions were generated and a systematic review was conducted to identify published randomised clinical trials that answered these questions. We used the GRADE (Grading of Recommendations Assessment, Development and Evaluation) approach to assess the quality of the evidence and the strength of recommendations. The resulting guideline addresses gastric bypass surgery, custom-made dual-block mandibular advancement devices, hypoglossal nerve stimulation, myofunctional therapy, maxillo-mandibular osteotomy, carbonic anhydrase inhibitors and positional therapy. These recommendations can be used to benchmark quality of care for people with OSA across Europe and to improve outcomes.
Purpose Occlusal changes are common during long-term treatment with oral appliances (OAs) for sleep apnea. The aim of the present study was to compare subjectively reported bite changes with objective findings. Methods Consecutive adherent treated patients were asked to participate in this study. The patients responded to two questionnaires using numeric visual analogue scales (VAS), ranging from 0 (not at all) to 10 (very much). The first questionnaire included open questions and the second questionnaire comprised specific questions about side effects. Measurements of overjet, overbite, and space for the teeth were made on plaster casts taken before treatment start and at follow-up. Results Thirty-eight (12 women) patients with a median age of 64 years (interquartile range (IQR) 57 to 69 years) and a median treatment time of 9.5 years (IQR 5.8 to 14.3 years) were included. Overjet, overbite, the molar relationship, and the irregularity of the lower front teeth had changed significantly during treatment. There were no associations between any of the patients' responses and the objectively measured bite changes. Younger patients, those with a small baseline overjet or overbite and those who developed an anterior crossbite were more likely to report bite changes. Conclusions Patients who choose to continue long-term treatment with oral appliances for sleep apnea are unaware of various types of bite changes. Such changes will, however, progressively increase in magnitude and be more difficult to take care of, if needed. It is therefore important continuously to follow up patients in regard to bite changes.
Oral appliances are increasingly recommended for selected patients with obstructive sleep apnoea (OSA) and those who do not tolerate nor prefer continuous positive airway pressure. The most commonly used oral appliance advances the lower jaw during sleep, the so-called mandibular advancement device (MAD). Patients seek treatment because of disturbing snoring, daytime symptoms, apnoeas that disturb sleep and the longer term consequences with regard to cardiovascular risks. MADs reduce the apnoea–hypopnoea index, although to various degrees among patients. Effects on daytime sleepiness have been observed mainly among the more severe OSA patients. Blood pressure may be reduced in MAD-treated OSA patients. There is, however, uncertainty about which patients will respond to this therapy in terms of apnoea reductions, decreased sleepiness and other symptoms, and reduced risk for future impaired health. The occurrence of side-effects also remains difficult to predict at present. The majority of sleep apnoea patients suffer from various comorbidities in terms of cardiovascular diseases, type 2 diabetes and depression. The most recent findings indicate that phenotyping of patients, considering various aspects of this multifaceted disease, will shed more light on the indications for MADs in patients with nightly sleep breathing disturbances. This review summarises the most recent knowledge about MAD treatment.
Background Obstructive sleep apnea is associated with high blood pressure. The magnitude of blood pressure effects from sleep apnea treatment is unclear. We aimed to determine the effect of mandibular advancement device therapy on ambulatory nighttime and daytime blood pressure in women and men with daytime sleepiness and snoring or mild to moderate sleep apnea (apnea‐hypopnea index, <30). Methods and Results In this 4‐month, double‐blind, randomized controlled trial comprising 96 untreated patients, 27 women and 58 men, aged 31 to 70 years, completed the study. The active group received individually made adjustable mandibular advancement devices, and the control group was given individually made sham devices, to be used during sleep. Polysomnographic sleep recordings and ambulatory 24‐hour blood pressure measurements were performed at baseline and at follow‐up. In women with mandibular advancement devices, the mean nighttime systolic blood pressure was 10.8 mm Hg (95% confidence interval, 4.0–17.7 mm Hg; P=0.004) lower than in the women in the sham group, adjusted for baseline blood pressure, age, body mass index, and the apnea‐hypopnea index. The mean nighttime adjusted diastolic blood pressure was 6.6 mm Hg (95% confidence interval, 2.7–10.4 mm Hg; P=0.002) lower in the mandibular advancement device group. In men, there were no significant differences in blood pressure at night or during the daytime between the intervention groups. Conclusions A mandibular advancement device for obstructive sleep apnea reduces nocturnal blood pressure in women. Clinical Trial Registration URL: https://www.clinicaltrials.gov. Unique identifier: NCT00477009.
Purpose The purpose of this study is to test the hypothesis that a flexible oral appliance without incisor coverage (OAFlex) increases the irregularity of the front teeth compared with a rigid appliance with incisor coverage (OARigid) in patients treated for obstructive sleep apnea (OSA). Method and patients Nineteen patients (10 men) who had used OARigid and 22 patients (19 men) who had used OAFlex with a median age of 61 years (IQR of 56 to 67 years) who had been treated during a median period of 2.9 years (IQR of 2.7 to 3.1 years) were included in the study. There was no difference in age (p = 0.601) or treatment time (p = 0.432) between the two appliance groups. The patients had clinical examinations, responded to a questionnaire, and had impressions taken for plaster casts. The irregularity of the front teeth was measured by Little's Index, where the combined linear displacement of all the front teeth is assessed. Changes between baseline and follow-up were compared between the two groups. Results The OAFlex group increased the irregularity of their lower front teeth by 0.3 mm (p = 0.018), while the OARigid group had unchanged frontal irregularity (p = 0.717). The difference between the groups was significant (p = 0.035). There were no changes in the irregularity of the upper front teeth in either group. Patient satisfaction with treatment did not differ between the two appliances. Conclusions The present results support the hypothesis that a flexible OA without incisor coverage increases the irregularity of the lower front teeth compared with a rigid OA with incisor coverage.
Oral appliances (OAs) hold the lower jaw forward to reduce obstructive sleep apneas. Some OA designs allow mouth opening, which influences the forward positioning of the lower jaw. The aim of this pilot study was to compare the efficacy of an adjustable, custom-made OA (Narval®) in its original design, which allowed mouth opening, with the same OA with elastic bands that restricted mouth opening.
s of the 25th Anniversary Meeting of the American Academy of Dental Sleep Medicine: Denver, CO, June 9–11, 2016 Editor-in-Chief Leslie Dort, DDS Deputy Editor Olivier Vanderveken, MD, PhD Associate Editors Fernanda Almeida, DDS, PhD Gilles Lavigne, DMD, PhD Rose Sheats, DMD Executive Director Jerome A. Barrett Managing Editor Andrew Miller Journal of Dental Sleep Medicine (JDSM) (Online 2333-9756; Website: www.jdsm.org) is published online quarterly on the 10th of January, April, July and October by the American Academy of Dental Sleep Medicine, 2510 North Frontage Road, Darien, IL 60561-1511, phone (630) 737-9705 and
Obstructive sleep apnea syndrome (OSAS) is the most common sleep disordered breathing disorder (SDB) in adults and is characterized by a recurrent partial or complete collapse of the upper airway during sleep. This can be caused by many factors, sometimes interacting, such as skeletal malformations, soft tissue crowding, respiratory instability and the various effects of aging, obesity and gender that dictate craniofacial and upper airway anatomy. Research has demonstrated that the majority of patients exhibit at least one anatomical component such as retrognathia or a narrow posterior airway space that predisposes to the development of OSAS. Within the predisposing elements for OSAS many seem to point to anatomical characteristics. A standardized and relatively simple radiologic technique to evaluate anatomical craniofacial relationships is cephalometry. This has been used already for a long time in orthodontics, but is now gradually being introduced in OSAS treatment to envisage optimal treatment selection as well as to predict treatment outcomes. The purpose of the present review is to evaluate the contribution of cephalometry in the prediction of outcomes from OSAS treatments that depend on the upper airway morphology in their mechanisms of action such as oral appliances that advance the mandible as well as various surgical methods. In addition, an overview of imaging modalities and methods that currently are being used in cephalometric analysis in OSAS patients is provided. The findings indicate that isolated cephalometric parameters cannot be used to reliably predict treatment outcomes from mandibular advancement devices and surgical methods for OSAS. Extreme or outlying values of cephalometric parameters may rather be used as contra-indicators or 'red flags' instead of predictors.
The purpose of the present study was to evaluate the long-term efficacy of oral appliances (OAs) in early treated patients with obstructive sleep apnea (OSA).
The simplicity of oral appliance therapy in the treatment of adult patients with snoring and obstructive sleep apnea (OSA) has resulted in a worldwide interest for this treatment modality. Mandibular advancement devices (MADs) that hold the lower jaw forward during sleep are mainly indicated for patients with milder OSA and those with CPAP intolerance. There has been minor attention on age when suggesting treatment alternatives for patients with OSA. Some studies indicate that there is a weak negative relationship between treatment success from MADs and higher age, but no studies have stratified their samples with respect to age.