This study quantified the distribution of nerves and adjacent anatomies surrounding human common hepatic artery (CHA) as guidance for catheter based denervation. CHA collected from cadaveric human donors (n = 20) were histologically evaluated and periarterial dimensions and distributions of nerves, lymph nodes, pancreas and blood vessels quantified by digital morphometry. Nerve abundance decreased significantly with distance from the aortic ostium (P < 0.0001) and was higher in the Superior/Inferior compared to the Anterior/Posterior quadrants (P = 0.014). In each locational group, nerves were absent from the artery wall, and starting 0.5-1.0 mm from the lumen exhibited a first order dependence on radial distance, fully defined by the median distance. Median subject-averaged nerve distance to the lumen was 2.75 mm, ranging from 2.1-3.1 mm in different arterial segments and quadrants and 2.0-3.5 mm in individuals. Inter-individual variance was high, with certain individuals exhibiting 50th and 75th nerve distances of, respectively, 3.5 and 6.5 mm The pancreas rarely approached within 4 mm of the lumen proximally and 2.5 mm more distally. The data indicate that the CHA is a rich and accessible target for sympathetic denervation regardless of sex and diabetes, with efficacy and safety most optimally balanced proximally.
Coronary bifurcations have complex flow patterns including secondary flow zones and helical flow, which directly affect pathophysiological mechanisms such as the development of atherosclerosis. The objective of this study was to generate insights into the effects of curvature, bifurcation angle and the presence of stents on flow patterns and resulting haemodynamics in coronary left main bifurcations. The blood flow and associated metrics were modelled in both idealised and patient-specific bifurcations with varying curvature and bifurcation angles with and without stents, resulting in a total of 128 geometries considered. The results showed that larger curvature of bifurcating vessels has a significant influence on secondary flow, especially with distance to the bifurcation region, causing a skew, spin and asymmetry of Dean vortices, an increase in helical flow intensity with symmetry loss, and a decrease in adversely low time-average wall shear stress (TAWSS). Generally, asymmetric flow patterns coincided with adversely low TAWSS regions. In identical stented geometries, the presence of the stents induced local recirculation immediately adjacent to the stent struts, thus generating adversely low TAWSS in these areas, with some effect on the overall secondary flow. Overall, the effect of stents outweighed the effect of curvature and BA. This new knowledge contributes to a better understanding of the joint effects of curvature, bifurcation angle, and stents on flow patterns and haemodynamics in coronary bifurcations.
We evaluated the preclinical safety of a novel paclitaxel-coated balloon catheter (PCB) with a nitinol constraining structure positioned over it, designed to improve acute treatment of stenotic and occluded arteries. PCBs (TriReme Medical, Singapore) with 5.53mg PTX and (3μg/mm2, 6×80 mm) and a
Paclitaxel coated balloon catheters (PCB) were developed as a polymer-free non-implantable alternative to drug eluting stents, delivering similar drug payloads in a matter of minutes. While PCB have shown efficacy in treating peripheral arterial disease in certain patient groups, restenosis rates remain high and there is no class effect. To help further optimize these devices, we developed a scanning electron microscopy (SEM) imaging technique and computational modeling approach that provide insights into the coating micromorphology dependence of in vivo drug transfer and retention. PCBs coated with amorphous/flaky or microneedle coatings were inflated for 60 sec in porcine femoral arteries. Animals were euthanized at 0.5, 24 and 72 h and treated arteries processed for SEM to image endoluminal coating distribution followed by paclitaxel quantification by mass spectrometry (MS). Endoluminal surfaces exhibited sparse coating patches at 0.5 h, predominantly protruding (13.71 vs 0.59%, P < 0.001), with similar micro-morphologies to nominal PCB surfaces. Microneedle coating covered a 1.5-fold endoluminal area (16.1 vs 10.7%, P = 0.0035) owing to higher proximal and distal delivery, and achieved 1.5-fold tissue concentrations by MS (1933 vs 1298 μg/g, P = 0.1745) compared to amorphous/flaky coating. Acute longitudinal coating distribution tracked computationally predicted microindentation pressure gradients (r = 0.9, P < 0.001), with superior transfer of the microneedle coatings attributed to their amplification of angioplasty contact pressures. By 24 h, paclitaxel concentration and coated tissue areas both declined by >93% even as nonprotruding coating levels were stable between 0.5 and 72 h, and 2.7-fold higher for microneedle vs flaky coating (0.64 vs 0.24%, P = 0.0195). Tissue retained paclitaxel concentrations at 24-72 h trended 1.7-fold higher post treatment with microneedle coating compared to the amorphous/flaky coating (69.9 vs 39.9 μg/g, P = 0.066). Thus, balloon based drug delivery is critically dependent on coating micromorphologies, with superior performance exhibited by micromorphologies that amplify angioplasty pressures.
This study sought to evaluate perisplenic artery nerve distribution and the feasibility of splenic artery denervation (SDN). The NEXION radiofrequency catheter was used to perform SDN in healthy and inflammatory arthritis pigs. Splenic artery anatomy, nerve distribution, and splenic norepinephrine (NEPI) levels were evaluated before and after SDN. Perisplenic artery nerves were primarily distributed within 2.5 mm of the arterial lumen and were largely sympathetic on the basis of tyrosine hydroxylase expression. The pancreas, tended to be circumferentially positioned around the proximal splenic artery, typically >2.5 mm from the lumen, ensuring that most of the nerves could be targeted without affecting this sensitive organ. The mid segment of the splenic artery was relatively free of contact with the adjacent pancreas. Splenic NEPI levels and nerve abundance followed a decreasing gradient from the proximal to distal splenic artery. SDN resulted in significant reductions in splenic NEPI levels at day 14 (60.7%, P=0.024) in naive pigs and day 45 (100%, P=0.001) in inflammatory arthritis pigs. There was no significant effect of SDN on joint soft tissue injury or circulating inflammatory markers in the inflammatory arthritis model. The majority of perisplenic arterial nerves are within close proximity of the lumen and are primarily sympathetic efferent fibers. Nerves in the mid-segment may be the preferred SDN target given their proximity to the artery and paucity of periarterial off-target organs. SDN appears safe and effective at reducing splenic NEPI levels.
The failure of the prospective, randomized, sham-controlled SYMPLICITY HTN-3 trial to show significant difference in reduction of systolic blood pressure (SBP) in patients with resistant hypertension 6 months after renal denervation (RDN) compared with control subjects was attributed in part to
Radiofrequency renal denervation is under investigation for treatment of hypertension with variable success. We developed preclinical models to examine the dependence of ablation biomarkers on renal denervation treatment parameters and anatomic variables. One hundred twenty-nine porcine renal arteries were denervated with an irrigated radiofrequency catheter with multiple helically arrayed electrodes. Nerve effects and ablation geometries at 7 days were characterized histomorphometrically and correlated with associated renal norepinephrine levels. Norepinephrine exhibited a threshold dependence on the percentage of affected nerves across the range of treatment durations (30–60 s) and power set points (6–20 W). For 15 W/30 s treatments, norepinephrine reduction and percentage of affected nerves tracked with number of electrode treatments, confirming additive effects of helically staggered ablations. Threshold effects were only attained when ≥4 electrodes were powered. Histomorphometry and computational modeling both illustrated that radiofrequency treatments directed at large neighboring veins resulted in subaverage ablation areas and, therefore, contributed suboptimally to efficacy. Account for measured nerve distribution patterns and the annular geometry of the artery revealed that, regardless of treatment variables, total ablation area and circumferential coverage were the prime determinants of renal denervation efficacy, with increased efficacy at smaller diameters.
Periarterial lymph nodes and blood vessels can shield nerves from radiofrequency heating and limit the efficacy of catheter based renal denervation (RDN). We quantified the distributions of accessible and shielded nerves surrounding porcine renal arteries. Left and right renal arteries from 9 swine
The spleen plays an important role in the immune response to inflammatory conditions including cancer, myocardial infarction and atherosclerosis. Device-based neuromodulation of the spleen’s neural pathways is an emerging therapeutic approach to regulating the immune response in various
Sex-related differences have been noted in cardiovascular anatomy, pathophysiology, and treatment responses, yet we continued to drive evaluation of vascular device development in animal models without consideration of animal sex. We aimed to understand sex-related differences in the vascular responses to stent implantation by analyzing the pooled data of endovascular interventions in 164 Yucatan mini-swine (87 female, 77 male). Bare metal stents (BMS) or drug-eluting stents (DES) were implanted in 212 coronary arteries (63 single BMS implantation, 68 single DES implantation, 33 overlapped BMS implantation, and 48 overlapped DES implantation). Histomorphological parameters were evaluated from vascular specimens at 3-365 days after stent implantation and evaluated values were compared between female and male groups. While neointima formation at all times after implantation was invariant to sex, statistically significant differences between female and male groups were observed in injury, inflammation, adventitial fibrosis, and neointimal fibrin deposition. These differences were observed independently, i.e., for different procedure types and at different follow-up timings. Only subtle temporal sex-related differences were observed in extent and timing of resolution of inflammation and fibrin clearance. These subtle sex-related differences may be increasingly important as interventional devices meld novel materials that erode and innovations in drug delivery. Erodible materials may act differently if inflammation has a different temporal sequence with sex, and drug distribution after balloon or stent delivery might be different if the fibrin clearance speaks to different modes of pharmacokinetics in male and female swine.
Polymer-free drug-coated stents (PF DCS) avoid the concern for inflammatory material responses, but pose challenges in providing controlled drug release and sustained tissue retention. We used immunofluorescence (IF) methods to contrast the arterial distribution of Sirolimus and the highly
BACKGROUND:Innovations in drug eluting stent designs make it increasingly important to develop models for differentiating performance through spatial definition of drug, receptor binding and cell state. METHODS:Two designs of sirolimus analog eluting stents were implanted into porcine coronary arteries for 28, 60 or 90 days (n = 9/time point), durable coating (Xience) and deployable absorbable coating (MiStent). Explanted arteries were evaluated for drug content (n = 3/time point) by LC-MS/MS and for drug and target protein (mTOR) distributions by immunofluorescence (IF, n = 6/time point). A computational model was developed to predict drug release and arterial distribution maps. RESULTS:Both stents released the majority of drug load by 28 days, with different tissue retention efficiencies (91.4 ± 4.9% MiStent versus 21.5 ± 1.9% Xience, P < 0.001). Computational modeling of MiStent coating deployment and microcrystal dissolution recapitulated in vivo drug release and net tissue content and predicted that >98.5% of deployed drug remains crystalline through 90 days. Immunofluorescence and computational modeling showed peristrut drug localization for both stents, with similar peaks, but high interstrut levels only at sites of coating deployment from the absorbable coating. Co-localization of mTOR-IF with drug-IF for both devices showed persistent drug effects, though with differential drug-receptor pharmacokinetics. CONCLUSIONS:Immunofluorescence and computational modeling provide insights into drug distribution and binding status that can help differentiate drug delivery technologies. Herein we found that tissue deployment of slow dissolving crystalline drug particles results in temporally and spatially more uniform drug delivery to interstrut zones that might otherwise be under-dosed without excess peristrut drug.
AIMS Simple surface modifications can enhance coronary stent performance. Ultra-hydrophilic surface (UHS) treatment of contemporary bare metal stents (BMS) was assessed in vivo to verify whether such stents can provide long-term efficacy comparable to second-generation drug-eluting stents (DES) while promoting healing comparably to BMS. METHODS AND RESULTS UHS-treated BMS, untreated BMS and corresponding DES were tested for three commercial platforms. A thirty-day and a 90-day porcine coronary model were used to characterise late tissue response. Three-day porcine coronary and seven-day rabbit iliac models were used for early healing assessment. In porcine coronary arteries, hydrophilic treatment reduced intimal hyperplasia relative to the BMS and corresponding DES platforms (1.5-fold to threefold reduction in 30-day angiographic and histological stenosis; p<0.04). Endothelialisation was similar on UHS-treated BMS and untreated BMS, both in swine and rabbit models, and lower on DES. Elevation in thrombotic indices was infrequent (never observed with UHS, rare with BMS, most often with DES), but, when present, correlated with reduced endothelialisation (p<0.01). CONCLUSIONS Ultra-hydrophilic surface treatment of contemporary stents conferred good healing while moderating neointimal and thrombotic responses. Such surfaces may offer safe alternatives to DES, particularly when rapid healing and short dual antiplatelet therapy (DAPT) are crucial.
Background: The safety and efficacy of a novel cobalt alloy-based coronary stent with a durable elastomeric polymer eluting the antiproliferative agent ridaforolimus for treatment of patients with coronary artery disease is undetermined. Methods: A prospective, international 1:1 randomized trial was conducted to evaluate in a noninferiority design the relative safety and efficacy of ridaforolimus-eluting stents (RESs) and slow-release zotarolimus-eluting stents among 1919 patients undergoing percutaneous coronary intervention at 76 centers. Inclusion criteria allowed enrollment of patients with recent myocardial infarction, total occlusions, bifurcations lesions, and other complex conditions. Results: Baseline clinical and angiographic characteristics were similar between the groups. Overall, mean age was 63.4 years, 32.5% had diabetes mellitus, and 39.7% presented with acute coronary syndromes. At 12 months, the primary end point of target lesion failure (composite of cardiac death, target vessel-related myocardial infarction, and target lesion revascularization) was 5.4% for both devices (upper bound of 1-sided 95% confidence interval 1.8%, P noninferiority =0.001). Definite/probable stent thrombosis rates were low in both groups (0.4% RES versus 0.6% zotarolimus-eluting stent, P =0.75); 13-month angiographic in-stent late lumen loss was 0.22±0.41 mm and 0.23±0.39 mm ( P noninferiority =0.004) for the RES and zotarolimus-eluting stent groups, respectively, and intravascular ultrasound percent neointimal hyperplasia was 8.10±5.81 and 8.85±7.77, respectively ( P noninferiority =0.01). Conclusions: In the present trial, which allowed broad inclusion criteria, the novel RESs met the prespecified criteria for noninferiority compared with zotarolimus-eluting stents for the primary end point of target lesion failure at 12 months and had similar measures of late lumen loss. These findings support the safety and efficacy of RESs in patients who are representative of clinical practice. Clinical Trial Registration: URL: http://www.clinicaltrials.gov . Unique identifier: NCT01995487.