Objective To establish an open-source FHIR-compatible platform to standardize assessment of automated entity extraction for structured radiological reporting. Methods a modular web-based platform featuring an interactive assessment interface for automated entity extraction from free-text radiological reports was developed including an 11-category error taxonomy. 119 chest X-ray reports were included through a 45-field structured template (39 single-choice, 6 free-text keys) using zero-shot prompting with Mistral-Small-3.2-24B and Llama-3.3-70B. Two medical researchers evaluated 5,355 extracted items, assigning acceptance ratings with error classifications and corrections through consensus adjudication. Processing and rating times, field applicability, acceptance rates, error class distributions, text coverage, Matthews Correlation Coefficient (MCC) for 31 binary-classifiable keys were measured. Two models were compared using paired t-tests, Wilcoxon signed-rank tests, paired-difference linear mixed model (LMM) accounting for patient-level clustering. Results All extractions produced valid schema-conformant outputs. Median extraction time was 104.8s (Mistral). Median rating time was 111.5s per report. Field applicability rates varied across fields (median 19.3%). Overall acceptance rate was 97.5%, decreasing to 76.0% for non-empty fields. Content errors dominated (84.8% of rejected extractions), primarily missing information (55.0%; 3.8% of all extractions) and unsupported inferences (17.3%). Template coverage averaged 93.9%. MCC was 0.799. Mistral-Small-3.2-24B significantly outperformed Llama-3.3-70B (LMM: mean difference=0.098, 95% CI [0.079, 0.117], p<0.001; paired t-test: p<0.001). Conclusions Our open-source, FHIR-compatible platform provides infrastructure for retrospective validation and systematic evaluation of automated entity extraction methods in radiological reports, enabling reproducible cross-institutional comparison of extraction. Processing latencies under research-grade hardware (median 104.8s for Mistral-Small-3.2-24B) reflect infrastructure constraints rather than fundamental limitations; clinical deployment requires further optimization beyond this pilot study.
Statement of problem. Implant-supported restorations may cause artifacts in magnetic resonance imaging (MRI) of the head and neck area. However, the effect of different alloys remains unclear. Purpose. The purpose of this in vitro study was to assess artifacts in head and neck MRI caused by implant-supported restorations with different alloys. Material and methods. Three dry mandibles were prepared to receive bilateral dental implants at the second premolar and second molar sites. Different alloy combinations were evaluated: titanium implants+cobalt chromium restorations; titanium-zirconium implants+cobalt chromium restorations; and zirconia implants+ceramic restorations. Specimens were imaged by using a 3-Tesla magnetic resonance scanner system (Achieva 3.0T TX; Philips GmbH) with a turbo-spin-echo sequence. Scan protocols were adjusted to optimize metal artifact reduction and shorten scan time. Artifact volumes were assessed and statistically analyzed by using the Kruskal-Wallis and Spearman tests (alpha=.05). Results. A statistically significant difference was found among artifact volume caused by different materials (P=.002). The presence of titanium alloy was correlated with the artifact volume (r=-.87). Artifacts were greater for titanium and fewer for titanium-zirconium alloys, whereas zirconia implants found only minimal artifacts. Conclusions. The dimension of artifacts produced by implant-supported restorations varied according to the material. (J Prosthet Dent 2025;133:1574-1579)
Background:To evaluate the effectiveness of a novel Perfusion Pattern (PP) scale in differentiating between proximal and distal middle cerebral artery (MCA) occlusions in patients with acute ischaemic stroke. Methods:This retrospective study included 201 patients with acute ischaemic stroke, categorised into two groups: those with M1 segment occlusions (n=114) and those with distal medium vessel occlusions (n=87). We analysed multimodal stroke CT imaging and clinical data, focusing on the occlusion site, hypoperfusion extent and basal ganglia involvement. Patients with tandem stenosis or multiple acute occlusions were excluded. Perfusion patterns were categorised into three types (PP-1, PP-2 and PP-3) based on the extent of hypoperfusion. Statistical analysis explored associations between the occlusion site, perfusion pattern and collateral status. Results:Among the 201 patients (mean age 75±14 years, 86 men), PP-1 was observed in 36.8% of patients (74/201), PP-2 in 27.4% (55/201) and PP-3 in 35.8% (72/201). The distribution of PP varied significantly by occlusion site (p<0.0001). Distal medium vessel occlusions were associated with PP-1 in 78.4% of cases (58/74), while PP-3 was most prevalent in M1 occlusions (90.3%, 65/72). The contingency coefficient revealed that occlusion location had a stronger association with the perfusion pattern (c=0.556) than collateral type (c=0.245). However, 21.6% of M1 occlusions (16/74) showed a PP-1 pattern and 9.7% of distal medium vessel occlusions (7/72) exhibited PP-3. Basal ganglia infarction presence was a reliable indicator of M1 occlusion with a 94% likelihood. Conclusions:Perfusion patterns can effectively differentiate between proximal and distal medium vessel MCA occlusions, aiding targeted assessment of CT angiography.
AbstractThis study aims to improve our understanding of acute ischemic stroke clot imaging by integrating CT attenuation information with MRI susceptibility signal of thrombi. For this proof-of-principle experimental study, fifty-seven clot analogs were produced using ovine venous blood with a broad histological spectrum. Each clot analog was analyzed to determine its RBC content and chemical composition, including water, Fe III, sodium, pH, and pO2. Non-contrast CT and a susceptibility-weighted MRI sequence were used for imaging. The study found that RBC content correlated more accurately than iron content with clot attenuation on CT. There was a strong correlation between Fe III content and RBC percentage in clots. Specifically, changes in RBC content accounted for 64% of the variance in Fe III content (R2 = 0.640; p < .0001). Thrombi with blooming artifacts (BA) displayed higher attenuation on non-contrast CT than those without (73.4 vs. 40 HU, p < .0001) and had the highest RBC and iron contents. The cut-off value of 1242 µg/g of iron predicted blooming artifacts with high sensitivity and specificity. The pH level strongly affected the appearance of blooming artifacts, particularly for negative clots with high RBC content. These findings provide significant insights into the imaging behavior of acute ischemic stroke clots across both imaging modalities and could potentially improve the diagnosis and treatment of acute stroke patients. Furthermore, these results open the possibility for future research aimed at developing pH-modulated therapeutic strategies based on the acid-base state of thrombi.
PurposeThis study aimed to assess the influence of magnetic resonance imaging (MRI) protocol on the decision-making for the positioning of dental implants in edentulous arches in comparison to planning based on cone beam computed tomography (CBCT).Materials and MethodsOne phantom was scanned with CBCT and two MRI protocols (T1- and T2-weighted). Two calibrated examiners performed digital implant planning (coDiagnostiX, Dental Wings), considering a digital prosthetic planning and alveolar ridge surface scan. Four implants were planned for each patient dataset, and the angular deviation between the long axis of the implants and the prosthetic planning occlusal plane was measured.ResultsEach examiner planned 40 implants, 12 implants with CBCT and 28 implants with MRI (16 with T1 and 12 with T2 images). Significant differences in angle deviation were observed between CBCT, T1, and T2 in the anterior region for both examiners (p = 0.009 for examiner 1 and p = 0.042 for examiner 2). Implants planned with CBCT showed significantly lower angular deviation than those based on the T1 and T2 scans for both examiners (p = 0.028 and p = 0.046 for examiner 1 and p = 0.028 and p = 0.027 for examiner 2). No significant difference in angular deviation was found between T1 and T2 for both examiners (examiner 1: p = 0.600, examiner 2: p = 0.916).ConclusionCompared to CBCT planning, the MRI protocol influenced decision-making for anterior dental implants, with angular deviations within acceptable clinical thresholds, but further studies are needed to validate these findings.
The purpose of this study was to assess the feasibility of SEMAC + VAT to reduce artifacts induced by dental implant-supported restorations, such as its impact on the image quality. Dental-implant supported restorations were installed in a dry mandible. Magnetic resonance scans were acquired on a 3-Tesla MRI system. Artifact suppression (SEMAC + VAT) was applied with different intensity modes (weak, moderate, strong). Artifacts assessment was performed by measuring the mandible volume increase in MRI images prior (reference dataset) and after installation of dental implant-supported prosthesis. Image quality was assessed by two examiners using a five-point scale. Inter-examiner concordance and correlation analysis was performed with Cronbach’s alpha and Spearman’s test with a significance level at p = 0.05. Mandible volume increased by 60.23% when no artifact suppression method was used. By applying SEMAC + VAT, the volume increase ranged from 17.13% (strong mode) to 32.77% (weak mode). Visualization of mandibular bone was positively correlated with SEMAC intensity degree. SEMAC + VAT reduced MRI artifacts caused by dental-implant supported restorations. A stronger suppression mode improved visualization of mandibular bone in detriment of the scanning time.
OBJECTIVES:The purpose of this study was to evaluate the MRI-artifact pattern produced by titanium and zirconia dental implants with different geometries (diameter and height).METHODS:Three titanium (Titan SLA, Straumann) and three zirconia (Pure Ceramic Implant, Straumann) dental implants differing on their design (diameter x height) were installed in porcine bone samples. Samples were scanned with a MRI (3T, T1W turbo spin echo sequence, TR/TE 25/3.5ms, voxel size 0.22×0.22×0.50 mm, scan time 11:18). Micro-CT was used as control group (80kV, 125mA, voxel size 16µm). Artifacts' distribution was measured at vestibular and lingual sites, mesial and distal sites, and at the apex. Statistical analysis was performed with Within-ANOVA (p=0.05).RESULTS:Artifacts distribution measured 2.57 ± 1.09 mm for titanium artifacts and 0.37 ± 0.20 mm for zirconia artifacts (p<0.05). Neither the measured sites (p=0.73) nor the implant geometries (p=0.43) influenced the appearance of artifacts.CONCLUSION:Artifacts were higher for titanium than zirconia implants. The artifacts pattern was similar for different dental implant geometries.
Exact histological clot composition remains unknown. The purpose of this study was to identify the best imaging variables to be extrapolated on clot composition and clarify variability in the imaging of thrombi by non-contrast CT. Using a CT-phantom and covering a wide range of histologies, we analyzed 80 clot analogs with respect to X-ray attenuation at 24 and 48 h after production. The mean, maximum, and minimum HU values for the axial and coronal reconstructions were recorded. Each thrombus underwent a corresponding histological analysis, together with a laboratory analysis of water and iron contents. Decision trees, a type of supervised machine learning, were used to select the primary variable altering attenuation and the best parameter for predicting histology. The decision trees selected red blood cells (RBCs) for correlation with all attenuation parameters (p < 0.001). Conversely, maximum attenuation on axial CT offered the greatest accuracy for discriminating up to four groups of clot histology (p < 0.001). Similar RBC-rich thrombi displayed variable imaging associated with different iron (p = 0.023) and white blood cell contents (p = 0.019). Water content varied among the different histologies but did not in itself account for the differences in attenuation. Independent factors determining clot attenuation were the RBCs (β = 0.33, CI = 0.219–0.441, p < 0.001) followed by the iron content (β = 0.005, CI = 0.0002–0.009, p = 0.042). Our findings suggest that it is possible to extract more and valuable information from NCCT that can be extrapolated to provide insights into clot histological and chemical composition.
The aim of this study was to assess trabecular bone morphology via magnetic-resonance imaging (MRI) using microcomputed tomography (µCT) as the control group. Porcine bone samples were scanned with T1-weighted turbo spin echo sequence imaging, using TR 25 ms, TE 3.5 ms, FOV 100 × 100 × 90, voxel size 0.22 × 0.22 × 0.50 mm, and scan time of 11:18. µCT was used as the control group with 80 kV, 125 mA, and a voxel size of 16 µm. The trabecular bone was segmented on the basis of a reference threshold value and morphological parameters. Bone volume (BV), Bone-volume fraction (BvTv), Bone specific surface (BsBv), trabecular thickness (TbTh), and trabecular separation (TbSp) were evaluated. Paired t-test and Pearson correlation test were performed at p = 0.05. MRI overestimated BV, BvTv, TbTh, and TbSp values. BsBv was the only parameter that was underestimated by MRI. High statistical correlation (r = 0.826; p < 0.05) was found for BV measurements. Within the limitations of this study, MRI overestimated trabecular bone parameters, but with a statistically significant fixed linear offset.
BACKGROUND:The syndrome of arachnomelia is an inherited malformation mainly of limbs, back and head in cattle. At present the arachnomelia syndrome has been well known mainly in Brown Swiss cattle. Nevertheless, the arachnomelia syndrome had been observed in the Hessian Simmental population during the decade 1964-1974. Recently, stillborn Simmental calves were observed having a morphology similar to the arachnomelia syndrome. The goal of this work was the characterization of the morphology and genealogy of the syndrome in Simmental to establish the basis for an effective management of the disease.RESULTS:The first pathologically confirmed arachnomelia syndrome-cases in the current Simmental population appeared in the year 2005. By 2007, an additional 140 calves with the arachnomelia syndrome were identified. The major pathological findings were malformed bones affecting the head, long bones of the legs and the vertebral column. It could be shown that, with the exception of two cases that were considered as phenocopies, all of the paternal and about two-third of the maternal pedigrees of the affected calves could be traced back to one common founder. Together with the data from experimental matings, the pedigree data support an autosomal recessive mutation being the etiology of the arachnomelia syndrome. The frequency of the mutation in the current population was estimated to be 3.32%.CONCLUSION:We describe the repeated occurrence of the arachnomelia syndrome in Simmental calves. It resembles completely the same defect occurring in the Brown Swiss breed. The mutation became relatively widespread amongst the current population. Therefore, a control system has to be established and it is highly desirable to map the disease and develop a genetic test system.
RATIONALE AND OBJECTIVES:Tools for monitoring modern target-specific antiangiogenic and antivascular therapies are highly desirable because treatment strategies are time consuming, expensive, and yet sometimes ineffective. Therefore, the aim of this experimental study was to evaluate the predictive value of steady-state ultrasmall particles of iron oxide (USPIO; SH U 555 C)-enhanced magnetic resonance imaging (MRI) for early assessment of antivascular tumor-treatment effectiveness. METHODS:Mice were inoculated with an HT-1080 fibrosarcoma xenograft and subjected to target-specific antivascular therapy using a selective thrombogenic vascular-targeting agent (truncated tissue factor fused to RGD peptide) or saline as control. Four to 8 hours after treatment, the USPIO-induced change in the transverse relaxation rate DeltaR2* was measured by MRI, and the vascular volume fraction (VVF) was calculated by calibrating DeltaR2* of the tumor by DeltaR2* of muscle tissue. Treatment response was defined by histologic grading of vascular thrombosis and tumor necrosis. RESULTS:After thrombogenic treatment, half of the HT-1080 xenograft-bearing animals showed only minor (=nonresponder) whereas the other half showed extensive tumor thrombosis (=responders). For responders, a significant decrease of DeltaR2* and VVF was observed compared with the control group (DeltaR2*: controls: 16 +/- 1 s-1 vs. responder: 4 +/- 2 s-1; P < 0.001) whereas DeltaR2* and VVF remained nearly unchanged for nonresponders (DeltaR2*: nonresponder 14 +/- 2 s-1). VVF and DeltaR2* values correlated inversely with the histologic grading of vascular thrombosis and tumor necrosis (VVF: r = -0.8; DeltaR2*: r = -0.71; P < 0.01). CONCLUSION:USPIO-enhanced MRI allows a noninvasive, early assessment of treatment efficacy of thrombogenic vascular-targeting agents.
PURPOSE:To prospectively investigate steady-state blood volume measurements for early quantitative monitoring of antiangiogenic treatment with ultrasmall superparamagnetic iron oxide (USPIO)-enhanced magnetic resonance (MR) imaging.MATERIALS AND METHODS:The institutional animal care committee approved all experiments. HT-1080 fibrosarcoma-bearing nude mice were injected with a thrombogenic vascular targeting agent (VTA) (11 nude mice, 20 tumors) or saline (12 nude mice, 20 tumors). USPIO-enhanced (SH U 555C) MR imaging was performed after the VTA was administered. USPIO-induced changes in tissue R2* (DeltaR2*) were measured with a T2-weighted dual-echo echo-planar imaging sequence, and the vascular volume fraction (VVF) was calculated. Parametric DeltaR2* maps were analyzed with respect to tumor perfusion patterns. Correlative histologic analysis was performed for grading of tissue thrombosis, and tissue perfusion was quantified with fluorescent microbeads. Unpaired Student t test and Spearman nonparametric correlation coefficient were used for statistical analysis.RESULTS:The DeltaR2* values were significantly (P < .001) reduced shortly after treatment initiation (mean DeltaR2*, 0.017 msec(-1) +/- 0.0014 [standard error] in control animals vs 0.005 msec(-1) +/- 0.0007 in animals that received VTA), which was also reflected by a decrease in the VVF (2.47% +/- 0.18 vs 0.41% +/- 0.48, P < .001). Histologic analysis revealed various degrees of tumor thrombosis after VTA treatment that correlated inversely with the DeltaR2* values (r = -0.83). Moreover, tumor perfusion measurements corroborated the MR results, indicating a significant reduction in tissue perfusion after VTA treatment (mean tissue fluorescence, 570.4 arbitrary units [au] per gram +/- 27 vs 161.7 au/g +/- 17; P < .05).CONCLUSION:USPIO-enhanced MR imaging enables early monitoring of antiangiogenic treatment of tumors.
PURPOSE:To prospectively assess bone marrow (BM) angiogenesis in patients with acute myeloid leukemia (AML) by using iron oxide-enhanced magnetic resonance (MR) imaging.MATERIALS AND METHODS:The study was institutional ethics committee approved. Informed signed consent was obtained from each study participant. The requirement for informed consent for use of data from a reference database was waived. Eleven patients (seven women, four men; mean age, 53 years+/-4.40 [standard deviation]) with an initial diagnosis of AML were enrolled in the study and underwent T2*-weighted two-echo echo-planar MR imaging of the pelvis before and after intravenous injection of a clinically approved iron oxide blood-pool contrast agent. Six healthy control subjects (one woman, five men; mean age, 35 years+/-2.31) were examined with the same MR protocol. The iron oxide-induced change in R2* relaxation rate (DeltaR2*) was calculated, and the vascular volume fraction (VVF) of the BM was derived by dividing the DeltaR2* of the BM by the DeltaR2* of the muscle. Parametric DeltaR2* maps were calculated to visualize vessel distribution. Patients underwent BM biopsy for correlative determination of microvessel density (MVD) and vascular endothelial growth factor (VEGF). Differences in DeltaR2*, VVF, VEGF, and MVD were compared by using the Wilcoxon rank sum test.RESULTS:DeltaR2* maps showed prominent areas of highly vascularized BM in the patients with AML, whereas the control subjects had moderately vascularized BM with homogeneous vessel distribution. Quantitative analysis revealed VVF values to be significantly higher in patients with AML than in control subjects: The mean VVF in the pelvis was 9.18%+/-1.54 for patients versus 3.91%+/-0.61 for control subjects (P=.010). In accordance with MR results, MVD (P=.009) and VEGF expression (P=.017) were significantly elevated in the AML group compared with values in the control group.CONCLUSION:Iron oxide-enhanced MR imaging enables assessment of BM angiogenesis in patients with AML.
Study Design. Preoperative magnetic resonance images (MRI) and postoperative axial computed tomography (CT) scans in 25 consecutive patients with idiopathic right thoracic adolescent scoliosis (AIS) and anterior correction and fusion with a dual rod system were analyzed in a prospective study.Objectives. Evaluation of the spatial relations between the vertebral body and the aorta and the relative migration of the aorta due to the anterior correction and instrumentation in right thoracic scoliosis patients.Summary of Background Data. In anterior scoliosis surgery, bicortical screw purchase is performed to increase pullout strength. However, impingement of the aorta due to excessive contralateral screw penetration has been reported, especially after endoscopic instrumentation. For a safe screw placement, knowledge of both the preoperative topographic relation of aorta and vertebral body and its changes due to surgical correction is crucial. Recent studies reported on a more lateral and posterior position of the aorta in AIS patients. However, there are hardly any data on the changes of the aortic position after anterior curve correction available in the current literature.Methods. All 25 patients underwent an identical anterior surgical technique with standard open approach and dual rod instrumentation of the primary curve. Preoperative MRI and postoperative sequential CT scans of 180 vertebrae were analyzed with respect to following parameters: vertebral body width and depth, diameter of the aorta, closest distance between aorta and the vertebral body, the aorta-vertebral angle, and the position of the aorta in relation to the spinal canal.Results. Before surgery, the aorta is positioned posterolaterally with an aorta-vertebral angle of between 78 degrees and 92 degrees (between T5 and T10). Between T11 and L2, the aorta is positioned more anteromedially with an aortavertebral angle from 62 degrees (T11) to 16 degrees (L2). After surgery, the aorta has migrated from a posterolateral to a more anteromedial position. This migration is maximal at the apex vertebra with an average change of the aorta- vertebral angle of 31.4 degrees. Whereas the distance between the aorta and the vertebral body increases at the upper and lower fusion levels, the aorta moves significantly closer to the vertebral body at the curve apex due to surgical correction. In patients with thoracic hypokyphosis, the aorta is positioned significantly more posterior than in patients with hyperkyphosis.Conclusions. This MRI and CT based study of 25 patients with thoracic AIS treated by standard open dual rod and dual screw instrumentation demonstrates a migration of the aorta by 31 degrees from a more posterolateral position before surgery to a more anteromedial position after surgery at the curve apex. Scoliosis surgeons should be aware of these changes; any excessive contralateral screw penetration must be avoided at any level.
Background: Computer-aided virtual three-dimensional (3D) surgical simulation assists the necessary visual understanding of complex pathological situations but has so far been dependent on expensive hardware and software.
RATIONALE AND OBJECTIVES:The authors performed this study to investigate structural variations in the trabecular bone of the proximal femur at high-resolution magnetic resonance (MR) imaging and high-resolution multisection computed tomography (CT). MATERIALS AND METHODS:Bone mineral density (BMD) was measured in 36 proximal human femur specimens by using dual x-ray absorptiometry. High-resolution MR imaging was performed at 1.5 T with an in-plane spatial resolution of 0.195 x 0.195 mm and a section thickness of 0.3 and 0.9 mm. Multisection CT was performed with an ultra-high-resolution protocol; images were obtained with an in-plane spatial resolution of 0.25 mm and a section thickness of 1 mm. In a subset of these specimens, micro CT was performed with an isotropic spatial resolution of 30 microm. Identical regions of interest (ROIs) were used to analyze images obtained with MR imaging, multisection CT, and micro CT. Trabecular bone structural parameters were obtained, and the parameters from the individual imaging modalities and BMD were correlated. RESULTS:Significant differences concerning the trabecular microarchitecture between the individual ROIs were demonstrated with multisection CT and MR imaging. A number of the correlations between structural parameters derived with multisection CT, MR imaging, micro CT, and BMD measurements were significant. For MR imaging, threshold technique and section thickness had an effect on structural parameters. CONCLUSION:Structural parameters obtained in the proximal femur with multisection CT and high-resolution MR imaging show regional differences. These techniques may be useful for depicting the trabecular architecture in the diagnosis of osteoporosis.
The computer-aided method presented is able to interpret and measure radiological structures automatically and reproducibly on a large number of randomly selected lateral head films of different film quality. For example the hard and soft tissue expression of the profile is used to discuss method, application and disadvantages. The performance of the system depends on image quality. The algorithm cannot be influenced by opacifications due to metal structure. In 90% of all cases the contours are identified correctly. Even if the image quality is poor, the recognition rate is about 84%. The selected cephalometric landmarks are placed in the right way in 85% of all cases. The constraint mathematical conditions and the high reproducibility improve the quality process of the cephalometric analysis. Recognition rates of 84% to 90% justify even nowadays the routine use of semi-automatic systems in PC-based analysis. With advancing digital radiography and improved computer performance, image interpreting systems will certainly become established.