In injured and diseased tissues, changes in molecular and cellular compositions, as well as tissue architecture, lead to alterations in both physiological and physical characteristics. Notably, the electrical properties of tissues, which can be characterized as bioelectrical impedance (bioimpedance), are closely linked to the health and pathological conditions of the tissues. This highlights the significant role of quantitatively characterizing these electrical properties in improving the accuracy and speed of diagnosis and prognosis. In this study, we investigate how diseases, injuries, and physical conditions can affect the electrical properties of lung tissues, using both rat and human lung tissue samples. Results showed that rat lung and trachea tissues exhibit a frequency-dependent behavior to alternating current (AC) across the frequency range of 0.1-300 kHz. The bioimpedance of the lung tissue increased with the level of aeration of the lung, which was manipulated by altering alveolar pressure (PALV: 1-15 cmH2O; bioimpedance level: 1.2-2.8 kS2; AC frequency: 2 kHz). This increase is mainly because air is electrically nonconductive. The bioimpedance of rat lungs injured via intratracheal aspiration of hydrochloric acid (HCl; volume: 1 mL; AC frequency: 2 kHz) decreased by at least 82 % compared to that of healthy control lungs due to accumulation of fluids inside the airspace of the injured lungs. Moreover, using decellularized lung tissues, we determined the contributions of cellular components and tissue extracellular matrix (ECM) on the electrical characteristics of the lung tissues. Specifically, we observed a considerable increase in bioimpedance in fibrotic human lung tissues due to excessive ECM deposition (healthy: 70.8 S2 +/- 10.2 S2, fibrotic: 132.1 S2 +/- 15.8 S2, frequency: 2 kHz). Overall, the findings of this study can enhance our understanding of the correlation between electrical properties and pathological lung conditions, thereby improving diagnostic and prognostic capabilities and aiding in the treatment of lung diseases and injuries. Statement of significance: The bioelectrical properties of tissue are closely linked to both its physiological and physical characteristics. This underscores the importance of quantitatively characterizing these properties to improve the accuracy and speed of diagnosis and prognosis. In this study, we investigate how the bioelectrical properties of lung tissues are affected by different physical states and pathological conditions using rat and human lung tissues. As the burden of lung diseases continues to increase, our findings can contribute to improved treatment outcomes by enabling accurate and rapid assessment of lung tissue conditions.
Pulmonary air leak is the most common complication of lung surgery, contributing to post-operative morbidity in up to 60% of patients; yet, there is no reliable treatment. Available surgical sealants do not match the demanding deformation mechanics of lung tissue; and therefore, fail to seal air leak. To address this therapeutic gap, a sealant with structural and mechanical similarity to subpleural lung is designed, developed, and systematically evaluated. This "lung-mimetic" sealant is a hydrofoam material that has alveolar-like porous ultrastructure, lung-like viscoelastic properties (adhesive, compressive, tensile), and lung extracellular matrix-derived signals (matrikines) to support tissue repair. In biocompatibility testing, the lung-mimetic sealant shows minimal cytotoxicity and immunogenicity in vitro. Human primary monocytes exposed to sealant matrikines in vitro upregulate key genes (MARCO, PDGFB, VEGF) known to correlate with pleural wound healing and tissue repair in vivo. In rat and swine models of pulmonary air leak, this lung-mimetic sealant rapidly seals air leak and restores baseline lung mechanics. Altogether, these data indicate that the lung-mimetic sealant can effectively seal pulmonary air leak and promote a favorable cellular response in vitro.
Ionizable lipid nanoparticles (LNPs) are pivotal in combating COVID-19, and numerous preclinical and clinical studies have highlighted their potential in nucleic acid-based therapies and vaccines. However, the effectiveness of endosomal escape for the nucleic acid cargos encapsulated in LNPs is still low, leading to suboptimal treatment outcomes and side effects. Hence, improving endosomal escape is crucial for enhancing the efficacy of nucleic acid delivery using LNPs. Here, a mechanical oscillation (frequency: 65 Hz) is utilized to prompt the LNP-mediated endosomal escape. The results reveal this mechanical oscillation can induce the combination and fusion between LNPs with opposite surface charges, enhance endosomal escape of mRNA, and increase the transfection efficiency of mRNA. Additionally, cell viability remains high at 99.3% after treatment with oscillation, which is comparable to that of untreated cells. Furthermore, there is no obvious damage to mitochondrial membrane potential and Golgi apparatus integrity. Thus, this work presents a user-friendly and safe approach to enhancing endosomal escape of mRNA and boosting gene expression. As a result, this work can be potentially utilized in both research and clinical fields to facilitate LNP-based delivery by enabling more effective release of LNP-encapsulated cargos from endosomes.
Objective: Robot-assisted minimally invasive surgery remains limited by the absence of haptic feedback, which surgeons routinely rely on to assess tissue stiffness. This limitation hinders surgeons’ ability to identify and treat abnormal tissues, such as tumors, during robotic surgery. Methods: To address this challenge, we developed a robotic tissue palpation device capable of rapidly and noninvasively quantifying the stiffness of soft tissues, allowing surgeons to make objective and data-driven decisions during minimally invasive procedures. We evaluated the effectiveness of our device by measuring the stiffness of phantoms as well as lung, heart, liver, and skin tissues obtained from both rats and swine. Results: Results demonstrated that our device can accurately determine tissue stiffness and identify tumor mimics. Specifically, in swine lung, we determined elastic modulus (E) values of 9.1 ± 2.3, 16.8 ± 1.8, and 26.0 ± 3.6 kPa under different internal pressure of the lungs (PIP) of 2, 25, and 45 cmH2O, respectively. Using our device, we successfully located a 2- cm tumor mimic embedded at a depth of 5 mm in the lung subpleural region. Additionally, we measured E values of 33.0 ± 5.4, 19.2 ± 2.2, 33.5 ± 8.2, and 22.6 ± 6.0 kPa for swine heart, liver, abdominal skin, and muscle, respectively, which closely matched existing literature data. Conclusion/Significance: Results suggest that our robotic palpation device can be utilized during surgery, either as a stand-alone or additional tool integrated into existing robotic surgical systems, to enhance treatment outcomes by enabling accurate intraoperative identification of abnormal tissue.
The severe shortage of functional donor lungs that can be offered to recipients has been a major challenge in lung transplantation. Innovative ex vivo lung perfusion (EVLP) and tissue engineering methodologies are now being developed to repair damaged donor lungs that are deemed unsuitable for transplantation. To assess the efficacy of donor lung reconditioning methods intended to rehabilitate rejected donor lungs, monitoring of lung function with improved spatiotemporal resolution is needed. Recent developments in live imaging are enabling non-destructive, direct, and longitudinal modalities for assessing local tissue and whole lung functions. In this review, we describe how emerging live imaging modalities can be coupled with lung tissue engineering approaches to promote functional recovery of ex vivo donor lungs.
The airway epithelium lining the luminal surface of the respiratory tract creates a protective barrier that ensures maintenance of tissue homeostasis and prevention of respiratory diseases. The airway epithelium, unfortunately, is frequently injured by inhaled toxic materials, trauma, or medical procedures. Substantial or repeated airway epithelial injury can lead to dysregulated intrinsic repair pathways and aberrant tissue remodeling that can lead to dysfunctional airway epithelium. While disruption in the epithelial integrity is directly linked to degraded epithelial barrier function, the correlation between the structure and function of the airway epithelium remains elusive. In this study, we quantified the impact of acutely induced airway epithelium injury on disruption of the epithelial barrier functions. By monitoring alternation of the flow motions and tissue bioimpedance at local injury site, degradation of the epithelial functions, including mucociliary clearance and tight/adherens junction formation, were accurately determined with a high spatiotemporal resolution. Computational models that can simulate and predict the disruption of the mucociliary flow and airway tissue bioimpedance have been generated to assist interpretation of the experimental results. Collectively, findings of this study advance our knowledge of the structure–function relationships of the airway epithelium that can promote development of efficient and accurate diagnosis of airway tissue injury.
The inevitable gap between in vitro and in vivo degradation rate of biomaterials has been a challenging factor in the optimal designing of scaffold's degradation to be balanced with new tissue formation. To enable non-/minimum-invasive tracking of in vivo scaffold degradation, chemical modifications have been applied to label polymers with fluorescent dyes. However, the previous approaches may have limited expandability due to complicated synthesis processes. Here, we introduce a simple and efficient method to fluorescence labeling of polymeric scaffolds via blending with near-infrared (NIR) quantum dots (QDs), semiconductor nanocrystals with superior optical properties. QDs-labeled, 3D-printed PCL scaffolds showed promising efficiency and reliability in quantitative measurement of degradation using a custom-built fiber-optic imaging modality. Furthermore, QDs-PCL scaffolds showed neither cytotoxicity nor secondary labeling of adjacent cells. QDs-PCL scaffolds also supported the engineering of fibrous, cartilaginous, and osteogenic tissues from mesenchymal stem/progenitor cells (MSCs). In addition, QDs-PCL enabled a distinction between newly forming tissue and the remaining mass of scaffolds through multi-channel imaging. Thus, our findings suggest a simple and efficient QDs-labeling of PCL scaffolds and minimally invasive imaging modality that shows significant potential to enable in vivo tracking of scaffold degradation as well as new tissue formation.
Repeated injury to airway tissue can impair lung function and cause chronic lung disease, such as chronic obstructive pulmonary disease. Advances in regenerative medicine and bioreactor technologies offer opportunities to produce lab-grown functional tissue and organ constructs that can be used to screen drugs, model disease, and engineer tissue replacements. Here, a miniaturized bioreactor coupled with an imaging modality that allows in situ visualization of the inner lumen of explanted rat trachea during in vitro tissue manipulation and culture is described. Using this bioreactor, the protocol demonstrates imaging-guided selective removal of endogenous cellular components while preserving the intrinsic biochemical features and ultrastructure of the airway tissue matrix. Furthermore, the delivery, uniform distribution, and subsequent prolonged culture of exogenous cells on the decellularized airway lumen with optical monitoring in situ are shown. The results highlight that the imaging-guided bioreactor can potentially be used to facilitate the generation of functional in vitro airway tissues.
Pulmonary air leak is the most common complication of lung surgery, with air leaks that persist longer than 5 days representing a major source of post-surgery morbidity. Clinical management of air leaks is challenging due to limited methods to precisely locate and assess leaks. Here, we present a sound-guided methodology that enables rapid quantitative assessment and precise localization of air leaks by analyzing the distinct sounds generated as the air escapes through defective lung tissue. Air leaks often present after lung surgery due to loss of tissue integrity at or near a staple line. Accordingly, we investigated air leak sounds from a focal pleural defect in a rat model and from a staple line failure in a clinically relevant swine model to demonstrate the high sensitivity and translational potential of this approach. In rat and swine models of free-flowing air leak under positive pressure ventilation with intrapleural microphone 1 cm from the lung surface, we identified that: (a) pulmonary air leaks generate sounds that contain distinct harmonic series, (b) acoustic characteristics of air leak sounds can be used to classify leak severity, and (c) precise location of the air leak can be determined with high resolution (within 1 cm) by mapping the sound loudness level across the lung surface. Our findings suggest that sound-guided assessment and localization of pulmonary air leaks could serve as a diagnostic tool to inform air leak detection and treatment strategies during video-assisted thoracoscopic surgery (VATS) or thoracotomy procedures.
Recent synergistic advances in organ-on-chip and tissue engineering technologies offer opportunities to create in vitro -grown tissue or organ constructs that can faithfully recapitulate their in vivo counterparts. Such in vitro tissue or organ constructs can be utilized in multiple applications, including rapid drug screening, high-fidelity disease modeling, and precision medicine. Here, we report an imaging-guided bioreactor that allows in situ monitoring of the lumen of ex vivo airway tissues during controlled in vitro tissue manipulation and cultivation of isolated rat trachea. Using this platform, we demonstrated selective removal of the rat tracheal epithelium (i.e., de-epithelialization) without disrupting the underlying subepithelial cells and extracellular matrix. Through different tissue evaluation assays, such as immunofluorescent staining, DNA/protein quantification, and electron beam microscopy, we showed that the epithelium of the tracheal lumen can be effectively removed with negligible disruption in the underlying tissue layers, such as cartilage and blood vessel. Notably, using a custom-built micro-optical imaging device integrated with the bioreactor, the trachea lumen was visualized at the cellular level in real time, and removal of the endogenous epithelium and distribution of locally delivered exogenous cells were demonstrated in situ . Moreover, the de-epithelialized trachea supported on the bioreactor allowed attachment and growth of exogenous cells seeded topically on its denuded tissue surface. Collectively, the results suggest that our imaging-enabled rat trachea bioreactor and selective cell replacement method can facilitate creating of bioengineered in vitro airway tissue that can be used in different biomedical applications.
Injured or diseased airway epithelium due to repeated environmental insults or genetic mutations can lead to a functional decline of the lung and incurable lung diseases. Bioengineered airway tissue constructs can facilitate in vitro investigation of human lung diseases and accelerate the development of effective therapeutics. Here, we report robust tissue manipulation modalities that allow: (i) selective removal of the endogenous epithelium of in vitro cultured airway tissues and (ii) spatially uniform distribution and prolonged cultivation of exogenous cells that are implanted topically onto the denuded airway lumen. Results obtained highlight that our approach to airway tissue manipulation can facilitate controlled removal of the airway epithelium and subsequent homogeneous distribution of newly implanted cells. This study can contribute to the creation of innovative tissue engineering methodologies that can facilitate the treatment of lung diseases, such as cystic fibrosis, primary ciliary dyskinesia, and chronic obstructive pulmonary disease.
In living tissues, mechanical stiffness and biological function are intrinsically linked. Alterations in the stiffness of tissues can induce pathological interactions that affect cellular activity and tissue function. Underlying connections between tissue stiffness and disease highlights the importance of accurate quantitative characterizations of soft tissue mechanics, which can improve our understanding of disease and inform therapeutic development. In particular, accurate measurement of lung mechanical properties has been especially challenging due to the anatomical and mechanobiological complexities of the lung. Discrepancies between measured mechanical properties of dissected lung tissue samples and intact lung tissues in vivo has limited the ability to accurately characterize integral lung mechanics. Here, we report a non-destructive vacuum-assisted method to evaluate mechanical properties of soft biomaterials, including intact tissues and hydrogels. Using this approach, we measured elastic moduli of rat lung tissue that varied depending on stress-strain distribution throughout the lung. We also observed that the elastic moduli of enzymatically disrupted lung parenchyma increased by at least 64%. The reported methodology enables assessment of the nonlinear viscoelastic characteristics of intact lungs under normal and abnormal (i.e., injured, diseased) conditions and allows measurement of mechanical properties of tissue-mimetic biomaterials for use in therapeutics or in vitro models.
A biocompatible and biodegradable scaffold with load-bearing ability is required to enhance the repair of bone defects by facilitating the attachment, and proliferation of cells, and vascularization during new bone formation. However, it is challenging to maintain the porosity and biodegradability, as well as mechanical properties (especially compressive strength), at the same time. Therefore, in the present work, a biodegradable composite structure of poly(caprolactone) (PCL) was designed using compression molding with varying amounts of poly(glycolic acid) (PGA) (25, 50, 75 wt%) and fixed amount (20 wt%) of beta tricalcium phosphate (beta TCP). It was hypothesized that the fabricated composite structure will develop porosity during the degradation of the PGA and that the corresponding decrease in mechanical properties will be compensated by new bone formation and ingrowth, in vivo. Accordingly, we have systematically studied the effects of sample composition on time-dependent dissolution and mechanical properties of the PGA/beta TCP scaffolds. The compressive strength increased up to ~92 MPa at 50% compression of the designed PCL-PGA samples. Furthermore, the dissolution rate, as well as weight loss, was observed to increase with an increase in the PGA amount in PCL. Based on the mechanical properties and dissolution data, it is concluded that the PCL-PGA scaffolds with beta TCP can be suitable candidates for bone tissue engineering applications, specifically for the reconstruction of bone defects, where strength and biodegradation are both important characteristics.
Proteins and peptides-based biomaterials play a significant role in biomedical engineering. The protein and peptide-based scaffolds facilitate modification of a range of biomaterial properties, producing a promising alternative to synthetic polymeric scaffolds. The designed scaffolds can imitate the diverse properties of the natural extracellular matrix, and therefore, promote the cell adhesion, cell signaling, elasticity, and biodegradability. Cell-biomaterial interactions are intermediated by the nature and conformation of the adsorbed proteins. Considering the importance of proteins and peptides-modified scaffolds in the tissue engineering, the self-assembly of peptides can be altered for particular applications by varying the nature of peptide sequences. In addition, different types of biofunctionalization strategies have also been proposed to enhance the biological performance of hydrogels, particularly intrinsic bioactivity. This chapter provides a comprehensive overview on the fundamental properties, structure, and applications of proteins and peptides-based scaffold starting from the basic classification of common protein and peptide folds to the production of highly organized self-assembled structures with potential application in tissue engineering and regenerative medicine.
Electrical conductive poly(methyl methacrylate) (PMMA) nanocomposites with low percolation threshold are very challenging to be prepared. Here, we show that the miscibility between poly(ethylene oxide) (PEO) as matrix for predispersions of multi-walled carbon nanotubes (MWCNTs) and PMMA represents an efficient approach to achieve very low electrical percolation threshold. PMMA/PEO-MWCNTs nanocomposites were prepared by a two-step solution casting method involving pre-mixing of MWCNTs with PEO and then mixing of PEO-MWCNTs with PMMA, resulting in a PMMA/PEO ratio of 80/20wt%. The electrical percolation threshold (EPT) value was determined to be ~0.07wt% which is significantly lower than most of the reported EPT values in the literature for PMMA/CNT composites. The very low electrical percolation threshold was attributed to the effectual role of PEO in self-assembly of secondary structures of nanotubes into an electrically conductive network. This was further confirmed by transmission electron microscopy and by comparing the obtained EPT value with the prediction of the excluded volume model in which statistical percolation threshold is defined based on uniform distribution of high-aspect ratio sticks in a matrix. Moreover, based on UV–Vis measurements and linear viscoelastic rheological measurements, optical and rheological percolation thresholds were obtained at nearly 0.01wt% and 0.5wt%, respectively.