Using proton-proton collision data corresponding to an integrated luminosity of 140 fb$^{-1}$ collected by the CMS experiment at $\sqrt{s}$ = 13 TeV, the $\Lambda_\text{b}^0$ $\to$ J/$\psi\Xi^-$K$^+$ decay is observed for the first time, with a statistical significance exceeding 5 standard deviations. The relative branching fraction, with respect to the $\Lambda_\text{b}^0$ $\to$ $\psi$(2S)$\Lambda$ decay, is measured to be $\mathcal{B}$($\Lambda_\text{b}^0$ $\to$ J/$\psi\Xi^-$K$^+$)/$\mathcal{B}$( $\Lambda_\text{b}^0$ $\to$ $\psi$(2S)$\Lambda$) = [3.38 $\pm$ 1.02 $\pm$ 0.61 $\pm$ 0.03]%, where the first uncertainty is statistical, the second is systematic, and the third is related to the uncertainties in $\mathcal{B}$($\psi$(2S) $\to$ J/$\psi\pi^+\pi^-$) and $\mathcal{B}$($\Xi^-$ $\to$ $\Lambda\pi^-$).
High-luminosity particle collider experiments such as the ones planned at the High-Luminosity Large Hadron Collider require ever-greater vertexing precision of the tracking detectors, necessitating reductions in the material budget of the detectors. Traditionally, the fractional radiation length (x/X-0) of detectors is either estimated using known properties of the constituent materials, or measured in dedicated runs of the final detector. In this paper, we present a method of direct measurement of the material budget of a CMS prototype module designed for the Phase-2 upgrade of the CMS detector using a 40-65 MeV positron beam. A total of 630 million events were collected at the Paul Scherrer Institut PiE1 experimental area using a three-plane telescope consisting of the prototype module as the central plane, surrounded by two MALTA monolithic pixel detectors. Fractional radiation lengths were extracted from scattering angle distributions using the Highland approximation for multiple scattering. A statistical technique recovered runs suffering from trigger desynchronisation, and several corrections were introduced to compensate for local inefficiencies related to geometric and beam shape constraints. Two regions of the module were surveyed and yielded average x/X-0 values of (0.72 +/- 0.05)% and (0.95 +/- 0.09)%, which are compatible with empirical estimates for these regions computed from known material properties of 0.753% and 0.892%, respectively. Two types of higher-granularity maps of the fractional radiation length were produced, subdivided either into rectangular regions of uniform size, or polygonal-shaped regions of uniform material composition. The results bode well for the CMS Phase-2 upgrade modules, which will play a key role in the minimisation of the material of the upgraded detector.
A test of lepton flavor universality in B ± → K ± μ + μ − and B ± → K ± e + e − decays, as well as a measurement of differential and integrated branching fractions of a nonresonant B ± → K ± μ + μ − decay are presented. The analysis is made possible by a dedicated data set of proton-proton collisions at s = 13 TeV recorded in 2018, by the CMS experiment at the LHC, using a special high-rate data stream designed for collecting about 10 billion unbiased b hadron decays. The ratio of the branching fractions B ( B ± → K ± μ + μ − ) to B ( B ± → K ± e + e − ) is determined from the measured double ratio R ( K ) of these decays to the respective branching fractions of the B ± → J / ψ K ± with J / ψ → μ + μ − and e + e − decays, which allow for significant cancellation of systematic uncertainties. The ratio R ( K ) is measured in the range 1.1 < q 2 < 6.0 GeV 2 , where q is the invariant mass of the lepton pair, and is found to be R ( K ) = 0.78 − 0.23 + 0.47 , in agreement with the standard model expectation R ( K ) ≈ 1 . This measurement is limited by the statistical precision of the electron channel. The integrated branching fraction in the same q 2 range, B ( B ± → K ± μ + μ − ) = ( 12.42 ± 0.68 ) × 10 − 8 , is consistent with the present world-average value and has a comparable precision.
A search is reported for charge-parity D$^0$ $\to$ K$^0_\mathrm{S}$K$^0_\mathrm{S}$ $CP$ violation in D$^0$ $\to$ K$^0_\mathrm{S}$K$^0_\mathrm{S}$ decays, using data collected in proton-proton collisions at $\sqrt{s}$ = 13 TeV recorded by the CMS experiment in 2018. The analysis uses a dedicated data set that corresponds to an integrated luminosity of 41.6 fb$^{-1}$, which consists of about 10 billion events containing a pair of \b hadrons, nearly all of which decay to charm hadrons. The flavor of the neutral D meson is determined by the pion charge in the reconstructed decays D$^{*+}$ $\to$ D$^0\pi^+$ and D$^{*-}$ $\to$ D$^0\pi^-$. The D$^0$ $\to$ K$^0_\mathrm{S}$K$^0_\mathrm{S}$ $CP$ asymmetry in D$^0$ $\to$ K$^0_\mathrm{S}$K$^0_\mathrm{S}$ is measured to be $A_{CP}$( K$^0_\mathrm{S}$K$^0_\mathrm{S}$) = (6.2 $\pm$ 3.0 $\pm$ 0.2 $\pm$ 0.8)%, where the three uncertainties represent the statistical uncertainty, the systematic uncertainty, and the uncertainty in the measurement of the D$^0$ $\to$ K$^0_\mathrm{S}$K$^0_\mathrm{S}$ $CP$ asymmetry in the D$^0$ $\to$ K$^0_\mathrm{S}\pi^+\pi^-$ decay. This is the first D$^0$ $\to$ K$^0_\mathrm{S}$K$^0_\mathrm{S}$ $CP$ asymmetry measurement by CMS in the charm sector as well as the first to utilize a fully hadronic final state.
The Large Hadron Collider at CERN will undergo an upgrade in order to increase its luminosity to 7.5 × 10 34 cm -2 s -1 . The increased luminosity during this High-Luminosity running phase, starting around 2029, means a higher rate of proton-proton interactions, hence a larger ionizing dose and particle fluence for the detectors. The current tracking system of the CMS experiment will be fully replaced in order to cope with the new operating conditions. Prototype planar pixel sensors for the CMS Inner Tracker with square 50 μm × 50 μm and rectangular 100 μm × 25 μm pixels read out by the RD53A chip were characterized in the lab and at the DESY-II testbeam facility in order to identify designs that meet the requirements of CMS during the High-Luminosity running phase. A spatial resolution of approximately 3.4 μm (2 μm) is obtained using the modules with 50 μm × 50 μm (100 μm × 25 μm) pixels at the optimal angle of incidence before irradiation. After irradiation to a 1 MeV neutron equivalent fluence of Φ eq = 5.3 × 10 15 cm -2 , a resolution of 9.4 μm is achieved at a bias voltage of 800 V using a module with 50 μm × 50 μm pixel size. All modules retain a hit efficiency in excess of 99% after irradiation to fluences up to 2.1 × 10 16 cm -2 . Further studies of the electrical properties of the modules, especially crosstalk, are also presented in this paper.
The Large Hadron Collider (LHC) at CERN will undergo major upgrades to increase the instantaneous luminosity up to 5–7.5×10 34 cm -2 s -1 . This High Luminosity upgrade of the LHC (HL-LHC) will deliver a total of 3000–4000 fb -1 of proton-proton collisions at a center-of-mass energy of 13–14 TeV. To cope with these challenging environmental conditions, the strip tracker of the CMS experiment will be upgraded using modules with two closely-spaced silicon sensors to provide information to include tracking in the Level-1 trigger selection. This paper describes the performance, in a test beam experiment, of the first prototype module based on the final version of the CMS Binary Chip front-end ASIC before and after the module was irradiated with neutrons. Results demonstrate that the prototype module satisfies the requirements, providing efficient tracking information, after being irradiated with a total fluence comparable to the one expected through the lifetime of the experiment.
To cope with the challenging environment of the planned high luminosity upgrade of the Large Hadron Collider (HL-LHC), scheduled to start operation in 2029, CMS will replace its entire tracking system. The requirements for the tracker are largely determined by the long operation time of 10 years with an instantaneous peak luminosity of up to 7.5 x 1034 cm-2 s-1 in the ultimate performance scenario. Depending on the radial distance from the interaction point, the silicon sensors will receive a particle fluence corresponding to a non-ionising energy loss of up to ?eq = 3.5 x 1016 cm-2. This paper focuses on planar pixel sensor design and qualification up to a fluence of ?eq = 1.4 x 1016 cm-2. For the development of appropriate planar pixel sensors an R&D program was initiated, which includes n+-p sensors on 150 mm (6") wafers with an active thickness of 150 mu m with pixel sizes of 100 x 25 mu m2 and 50 x 50 mu m2 manufactured by Hamamatsu Photonics K.K. (HPK). Single chip modules with ROC4Sens and RD53A readout chips were made. Irradiation with protons and neutrons, as well was an extensive test beam campaign at DESY were carried out. This paper presents the investigation of various assemblies mainly with ROC4Sens readout chips. It demonstrates that multiple designs fulfil the requirements in terms of breakdown voltage, leakage current and efficiency. The single point resolution for 50 x 50 mu m2 pixels is measured as 4.0 mu m for non-irradiated samples, and 6.3 mu m after irradiation to ?eq = 7.2 x 1015 cm-2.
The Short Strip ASIC (SSA) is one of the four front-end chips designed for the upgrade of the CMS Outer Tracker for the High Luminosity LHC. Together with the Macro-Pixel ASIC (MPA) it will instrument modules containing a strip and a macro-pixel sensor stacked on top of each other. The SSA provides both full readout of the strip hit information when triggered, and, together with the MPA, correlated clusters called stubs from the two sensors for use by the CMS Level-1 (L1) trigger system. Results from the first prototype module consisting of a sensor and two SSA chips are presented. The prototype module has been characterized at the Fermilab Test Beam Facility using a 120 GeV proton beam.
The CMS Inner Tracker, made of silicon pixel modules, will be entirely replaced prior to the start of the High Luminosity LHC period. One of the crucial components of the new Inner Tracker system is the readout chip, being developed by the RD53 Collaboration, and in particular its analogue front-end, which receives the signal from the sensor and digitizes it. Three different analogue front-ends (Synchronous, Linear, and Differential) were designed and implemented in the RD53A demonstrator chip. A dedicated evaluation program was carried out to select the most suitable design to build a radiation tolerant pixel detector able to sustain high particle rates with high efficiency and a small fraction of spurious pixel hits. The test results showed that all three analogue front-ends presented strong points, but also limitations. The Differential front-end demonstrated very low noise, but the threshold tuning became problematic after irradiation. Moreover, a saturation in the preamplifier feedback loop affected the return of the signal to baseline and thus increased the dead time. The Synchronous front-end showed very good timing performance, but also higher noise. For the Linear front-end all of the parameters were within specification, although this design had the largest time walk. This limitation was addressed and mitigated in an improved design. The analysis of the advantages and disadvantages of the three front-ends in the context of the CMS Inner Tracker operation requirements led to the selection of the improved design Linear front-end for integration in the final CMS readout chip.
Abstract During the operation of the CMS experiment at the High-Luminosity LHC the silicon sensors of the Phase-2 Outer Tracker will be exposed to radiation levels that could potentially deteriorate their performance. Previous studies had determined that planar float zone silicon with n-doped strips on a p-doped substrate was preferred over p-doped strips on an n-doped substrate. The last step in evaluating the optimal design for the mass production of about 200 m2 of silicon sensors was to compare sensors of baseline thickness (about 300 μm) to thinned sensors (about 240 μm), which promised several benefits at high radiation levels because of the higher electric fields at the same bias voltage. This study provides a direct comparison of these two thicknesses in terms of sensor characteristics as well as charge collection and hit efficiency for fluences up to 1.5 × 1015 neq/cm2. The measurement results demonstrate that sensors with about 300 μm thickness will ensure excellent tracking performance even at the highest considered fluence levels expected for the Phase-2 Outer Tracker.
During the era of the High Luminosity LHC (HL-LHC) the devices in its experiments will be subjected to increased radiation levels with high fluxes of neutrons and charged hadrons, especially in the inner detectors. A systematic program of radiation tests with neutrons and charged hadrons is being carried out by the CMS and ATLAS Collaborations in view of the upgrade of the experiments, in order to cope with the higher luminosity at HL-LHC and the associated increase in the pile-up events and radiation fluxes. In this work, results from a complementary radiation study with 60Co-γ photons are presented. The doses are equivalent to those that the outer layers of the silicon tracker systems of the two big LHC experiments will be subjected to. The devices in this study are MOS capacitors fabricated on the float-zone oxygenated p-type silicon wafer. The results of CV measurements on these devices are presented as a function of the total absorbed radiation dose following a specific annealing protocol. The measurements are compared with the results of a TCAD simulation.
We have developed a software for fast calculation of capacitances in planar silicon pixel and strip sensors, based on 3D and 2D numerical solutions of the Laplace’s equation. The validity of the 2D calculations was checked with capacitances measurements on Multi-Geometry Silicon Strip Detectors (MSSD). The 3D calculations were checked against pixel sensors capacitances taken from literature. In both cases the Laplace results were compared with simulation results obtained from the TCAD Sentaurus suite. The developed software is a useful tool for fast estimation of interstrip, interpixel and backplane capacitances before an embarkation on a more sophisticated platform.
We have developed a software for fast calculation of capacitances in planar silicon pixel and strip sensors, based on 3D and 2D numerical solutions of the Laplace's equation. The validity of the 2D calculations was checked with capacitances measurements on Multi-Geometry Silicon Strip Detectors (MSSD). The 3D calculations were tested by comparison with pixel sensors capacitance measurements from literature. In both cases the Laplace equation results were compared with simulations obtained from the TCAD Sentaurus suite. The developed software is a useful tool for fast estimation of interstrip, interpixel and backplane capacitances, saving computation time, as a first approximation before using a more sophisticated platform for more accurate results if needed.
In 2017 a new pixel detector was installed in the CMS detector. This so-called Phase-1 pixel detector features four barrel layers in the central region and three disks per end in the forward regions. The upgraded pixel detector requires an upgraded data acquisition (DAQ) system to accept a new data format and larger event sizes. A new DAQ and control system has been developed based on a combination of custom and commercial microTCA parts. Custom mezzanine cards on standard carrier cards provide a front-end driver for readout, and two types of front-end controller for configuration and the distribution of clock and trigger signals. Before the installation of the detector the DAQ system underwent a series of integration tests, including readout of the pilot pixel detector, which was constructed with prototype Phase-1 electronics and operated in CMS from 2015 to 2016, quality assurance of the CMS Phase-1 detector during its assembly, and testing with the CMS Central DAQ. This paper describes the Phase-1 pixel DAQ and control system, along with the integration tests and results. A description of the operational experience and performance in data taking is included.
A new CMS Tracker is under development for operation at the High Luminosity LHC from 2026 onwards. It includes an outer tracker based on dedicated modules that will reconstruct short track segments, called stubs, using spatially coincident clusters in two closely spaced silicon sensor layers. These modules allow the rejection of low transverse momentum track hits and reduce the data volume before transmission to the first level trigger. The inclusion of tracking information in the trigger decision is essential to limit the first level trigger accept rate. A customized front-end readout chip, the CMS Binary Chip (CBC), containing stub finding logic has been designed for this purpose. A prototype module, equipped with the CBC chip, has been constructed and operated for the first time in a 4 GeV/c positron beam at DESY. The behaviour of the stub finding was studied for different angles of beam incidence on a module, which allows an estimate of the sensitivity to transverse momentum within the future CMS detector. A sharp transverse momentum threshold around 2 GeV/c was demonstrated, which meets the requirement to reject a large fraction of low momentum tracks present in the LHC environment on-detector. This is the first realistic demonstration of a silicon tracking module that is able to select data, based on the particle's transverse momentum, for use in a first level trigger at the LHC . The results from this test are described here.
The high luminosity upgrade of the Large Hadron Collider, foreseen for 2026, necessitates the replacement of the CMS experiment’s silicon tracker. The innermost layer of the new pixel detector will be exposed to severe radiation, corresponding to a 1 MeV neutron equivalent fluence of up to \(\Phi _{eq} = 2 \times 10^{16}\) cm\(^{-2}\), and an ionising dose of \({\approx } 5\) MGy after an integrated luminosity of 3000 fb\(^{-1}\). Thin, planar silicon sensors are good candidates for this application, since the degradation of the signal produced by traversing particles is less severe than for thicker devices. In this paper, the results obtained from the characterisation of 100 and 200 \(\upmu \)m thick p-bulk pad diodes and strip sensors irradiated up to fluences of \(\Phi _{eq} = 1.3 \times 10^{16}\) cm\(^{-2}\) are shown.
The upgrade of the LHC to the High-Luminosity LHC (HL-LHC) is expected to increase the LHC design luminosity by an order of magnitude. This will require silicon tracking detectors with a significantly higher radiation hardness. The CMS Tracker Collaboration has conducted an irradiation and measurement campaign to identify suitable silicon sensor materials and strip designs for the future outer tracker at the CMS experiment. Based on these results, the collaboration has chosen to use n-in-p type silicon sensors and focus further investigations on the optimization of that sensor type. This paper describes the main measurement results and conclusions that motivated this decision.
The Upsilon(1S), Upsilon(2S), and Upsilon(3S) production cross sections are measured using a data sample corresponding to an integrated luminosity of 35.8 +/-1.4 inverse picobarns of proton-proton collisions at sqrt(s) = 7 TeV, collected with the CMS detector at the LHC. The Upsilon resonances are identified through their decays to dimuons. Integrated over the Upsilon transverse momentum range pt[Upsilon] < 50 GeV and rapidity range abs(y[Upsilon]) < 2.4, and assuming unpolarized Upsilon production, the products of the Upsilon production cross sections and dimuon branching fractions are sigma(pp to Upsilon(1S) X) B(Upsilon(1S) to mu+ mu-) = (8.55 +/- 0.05 +0.56/-0.50 +/- 0.34) nb, sigma(pp to Upsilon(2S) X) B(Upsilon(2S) to mu+ mu-) = (2.21 +/- 0.03 +0.16/-0.14 +/- 0.09) nb, sigma(pp to Upsilon(3S) X) B(Upsilon(3S) to mu+ mu-) = (1.11 +/- 0.02 +0.10/-0.08 +/- 0.04) nb, where the first uncertainty is statistical, the second is systematic, and the third is from the uncertainty in the integrated luminosity. The differential cross sections in bins of transverse momentum and rapidity, and the cross section ratios are presented. Cross section measurements performed within a restricted muon kinematic range and not corrected for acceptance are also provided. These latter measurements are independent of Upsilon polarization assumptions. The results are compared to theoretical predictions and previous measurements.