Metabolic abnormalities are at the center of many diseases, and the capability to film and quantify the metabolic activities of a single cell is important for understanding the heterogeneities in these abnormalities. In this paper, a functional plasmonic microscope (FPM) is used to image and measure metabolic activities without fluorescent labels at a single-cell level. The FPM can accurately image and quantify the subnanometer membrane fluctuations with a spatial resolution of 0.5 μm in real time. These active cell membrane fluctuations are caused by metabolic activities across the cell membrane. A three-dimensional (3D) morphology of the bottom cell membrane was imaged and reconstructed with FPM to illustrate the capability of the microscope for cell membrane characterization. Then, the subnanometer cell membrane fluctuations of single cells were imaged and quantified with the FPM using HeLa cells. Cell metabolic heterogeneity is analyzed based on membrane fluctuations of each individual cell that is exposed to similar environmental conditions. In addition, we demonstrated that the FPM could be used to evaluate the therapeutic responses of metabolic inhibitors (glycolysis pathway inhibitor STF 31) on a single-cell level. The result showed that the metabolic activities significantly decrease over time, but the nature of this response varies, depicting cell heterogeneity. A low-concentration dose showed a reduced fluctuation frequency with consistent fluctuation amplitudes, while the high-concentration dose showcased a decreasing trend in both cases. These results have demonstrated the capabilities of the functional plasmonic microscope to measure and quantify metabolic activities for drug discovery.
The understanding of lithium (Li) nucleation and growth is important to design better electrodes for high-performance batteries. However, the study of Li nucleation process is still limited because of the lack of imaging tools that can provide information of the entire dynamic process. We developed and used an operando reflection interference microscope (RIM) that enables real-time imaging and tracking the Li nucleation dynamics at a single nanoparticle level. This dynamic and operando imaging platform provides us with critical capabilities to continuously monitor and study the Li nucleation process. We find that the formation of initial Li nuclei is not at the exact same time point, and Li nucleation process shows the properties of both progressive and instantaneous nucleation. In addition, the RIM allows us to track the individual Li nucleus’s growth and extract spatially resolved overpotential map. The nonuniform overpotential map indicates that the localized electrochemical environments substantially influence the Li nucleation.
A new method for absolute measurement of the vacuum ultraviolet (VUV) photon flux at the edge of a plasma is described. The light produced by the plasma was allowed to strike a negatively biased, gold-coated copper substrate remote from the plasma. The resulting photoelectron emission current was measured, and the absolute photon flux was then found from the known photoelectron yield of Au. The method was used to quantify the amount of VUV light produced by an Ar/He inductively coupled plasma (ICP). Strong emissions at 104.82 and 106.67 nm, corresponding to the 1s2 and 1s4 resonant states of Ar, were observed. The maximum, integrated VUV photon flux measured at the remote location was 3.2 × 1013 photons/cm2 s. This was estimated to correspond to a flux of 5 × 1015 photons/cm2 s at the edge of the ICP, in the range of reported values under similar conditions.
Many fundamentally important biological phenomena involve the cells to establish and break down the adhesive interactions with the substrate. Here, we report a novel optical method that could directly image the electrochemical impedance of cell-substrate interactions at the single cell level with conventional microscopes and cameras. A thin conductive polymer layer on top of the ITO substrate (poly(3,4-ethylenedioxythiophene) poly(styrenesulfonate), PEDOT:PSS) is used as the impedance imaging and sensing layer. A sinusoidal electrochemical potential is applied to the conductive polymer film, and the ion intercalation and transportation in the PEDOT:PSS layer will change the absorption spectrum of the polymer film. The attachment of the cells to the substrate will block and affect the ion doping and dedoping process, and therefore change the color of the polymer film. This process can be captured by any upright or inverted microscope with a simple camera. Utilizing this method, we have successfully imaged the impedance of single-cell attachment, observed the variations of cell-substrate interactions, and measured the impedance changes at different stages of the attachment process. This paper has proposed and successfully demonstrated a new strategy that translates the electrochemical impedance information to an optical signal that could be imaged and used to quantify the local responses. In addition, this method does not need any specially designed optical setup, which may lead to its broad applications in the clinics and biological research laboratories.
Electrochemical impedance spectroscopy (EIS) is a powerful tool to measure and quantify the system impedance. However, EIS only provides an average result from the entire electrode surface. Here, we demonstrated a reflection impedance microscope (RIM) that allows us to image and quantify the localized impedance on conductive surfaces. The RIM is based on the sensitive dependence between the materials' optical properties, such as permittivity, and their local surface charge densities. The localized charge density variations introduced by the impedance measurements will lead to optical reflectivity changes on electrode surfaces. Our experiments demonstrated that reflectivity modulations are linearly proportional to the surface charge density on the electrode and the measurements show good agreement with the simple free electron gas model. The localized impedance distribution was successfully extracted from the reflectivity measurements together with the Randles equivalent circuit model. In addition, RIM is used to quantify the impedance on different conductive surfaces, such as indium tin oxide, gold film, and stainless steel electrodes. A polydimethylsiloxane-patterned electrode surface was used to demonstrate the impedance imaging capability of RIM. In the end, a single-cell impedance imaging was obtained by RIM.
In vivo, microvasculature provides oxygen, nutrients, and soluble factors necessary for cell survival and function. The highly tortuous, densely-packed, and interconnected three-dimensional (3D) architecture of microvasculature ensures that cells receive these crucial components. The ability to duplicate microvascular architecture in tissue-engineered models could provide a means to generate large-volume constructs as well as advanced microphysiological systems. Similarly, the ability to induce realistic flow in engineered microvasculature is crucial to recapitulating in vivo-like flow and transport. Advanced biofabrication techniques are capable of generating 3D, biomimetic microfluidic networks in hydrogels, however, these models can exhibit systemic aberrations in flow due to incorrect boundary conditions. To overcome this problem, we developed an automated method for generating synthetic augmented channels that induce the desired flow properties within three-dimensional microfluidic networks. These augmented inlets and outlets enforce the appropriate boundary conditions for achieving specified flow properties and create a three-dimensional output useful for image-guided fabrication techniques to create biomimetic microvascular networks.
A nearly monoenergetic Ar+ ion beam (100 eV peak energy, 3.5 eV full width at half maximum), with self-neutralized space charge, was extracted from a power modulated (pulsed) inductively coupled plasma (ICP), through a single grounded grid. The beam energy was set by applying a synchronous DC bias voltage to a boundary electrode in contact with the plasma, in the late afterglow of the power pulse. A retarding field energy analyzer and a movable Faraday cup were used to measure the ion energy distribution (IED) and the time resolved ion and electron current densities, as a function of position along the beam axis, to unravel the mechanism of self-neutralization of the space charge of the beam. When a +100 V DC bias was applied to the boundary electrode during the afterglow, a similar to 100 eV beam (ion density similar to 10(9) cm(-3) ) emerged that was space-charge neutralized by periodic injection of electrons, mainly during the early afterglow, into the region downstream of the extraction grid. A background plasma (electron density similar to 10(10) cm(-3)) was formed by these electrons, in conjunction with relatively low-energy ions (1-10eV) that flew out of the ICP when the DC bias was off, as well as formed by resonant charge exchange of the 100 eV beam ions with the background Ar in the downstream region near the extraction grid. The behavior of the beam IED as a function of pressure and power of the ICP as well as the timing of application of the DC bias voltage was also studied.
The swelling responses of thin polymer networks were examined as a function of primary polymer architecture. Thin films of linear or bottlebrush polystyrene were cast on polystyrene-grafted substrates, and surface-attached networks were prepared with a radiation crosslinking reaction. The dry and equilibrated swollen thicknesses were both determined with spectroscopic ellipsometry. The dry thickness, which reflects the insoluble fraction of the film after crosslinking, depends on the primary polymer size and radiation dose but is largely independent of primary polymer architecture. When networks are synthesized with a high radiation dose, producing a high density of crosslinks, the extent of swelling is similar for all primary polymer architectures and molecular weights. However, when networks are synthesized with a low radiation dose, the extent of swelling is reduced as the primary polymer becomes larger or increasingly branched. These trends are consistent with a simple Flory model for equilibrium swelling that describes the effects of branch junctions and radiation crosslinks on network elasticity.
Large arrays of permalloy (Ni81Fe19) annular structures were fabricated using a self-aligned patterning process based on ion-beam proximity lithography (IBPL), where a broad beam of energetic He ions is shaped into billions of ion beamlet by a stencil mask to pattern electron beam sensitive resist. IBPL was used to form an array of circular openings in poly(methyl methacrylate) (PMMA) resist, followed by a tone reversal process to form circular pillars in an underlying polymethylglutarimide (PMGI) layer. The PMGI pillars were conformally coated with silicon oxide, which was followed by anisotropic reactive ion etch (RIE) to form silicon oxide rings, which were transferred into the underlying sputter deposited permalloy thin film by ion milling. This fabrication approach was used to make 6 x 6 mm2 arrays of rings on a constant pitch of 670 nm with the outer diameters varied between 350 nm and 450 nm with a fixed inner diameter of 150 nm. Three unique samples that were fabricated and characterized using a vibrating sample magnetometer. The measured M-H loops showed the switching from an onion to a vortex and back to an onion state and are in good agreement with micromagnetic simulations and previously published data.
Electrowetting (EW) has drawn significant research interests in droplet-based microfluidics, and most applications focus on electronic displays, lab-on-a-chip devices and electro-optical switches, etc. This paper presents a new application of EW in enhancing pool boiling heat transfer. The working approach capitalizes on the complimentary roles of hydrophobicity and hydrophilicity played in boiling and takes advantage of the ability of EW to alter the surface wettability dynamically and reversely. In this work, the effects of alternating current EW (ACEW) on the heat transfer characteristics of various boiling regimes, including the onset of nucleate boiling (ONB), fully developed nucleate boiling, and film boiling at critical heat flux (CHF) conditions, are investigated. A synchronized high-speed optical imaging and infrared (IR) thermography approach is taken to obtain simultaneous measurements of the bubble dynamics and the wall temperature and heat flux distributions on the boiling surface. Based on the experimental data, boiling curves are constructed and the boiling heat transfer coefficients (BHTCs) are computed. Comparisons with the boiling characteristics of the baseline surface without ACEW demonstrate the efficacy of ACEW in enhancing the performance of pool boiling heat transfer. Some insights are also offered to understand the physics of the ACEW-enhanced boiling behaviors. (C) 2017 Elsevier Ltd. All rights reserved.
Electrowetting has drawn significant interests due to the potential applications in electronic displays, lab-on-a-chip devices and electro-optical switches, etc. Current understanding of electrowetting-induced droplet dynamics is hindered by the inadequacy of available numerical and theoretical models in properly handling the dynamic contact angle at the moving contact line. A combined numerical and experimental approach was employed in this work to study the spatiotemporal responses of a droplet subject to EW with both direct current and alternating current actuating signals. The time evolution of the droplet shape was measured using high-speed photography. Computational fluid dynamics models were developed by using the Volume of Fluid-Continuous Surface Force method in conjunction with a selected dynamic contact angle model. It was found that the numerical models were able to accurately predict the key parameters of the electrowetting-induced droplet dynamics.
ABSTRACTGrazing‐incidence X‐ray scattering (GIXS) is widely used to analyze the crystallinity and nanoscale structure in thin polymer films. However, ionizing radiation will generate free radicals that initiate crosslinking and/or chain scission, and structural damage will impact the ordering kinetics, thermodynamics, and crystallinity in many polymers. We report a simple methodology to screen for beam damage that is based on lithographic principles: films are exposed to patterns of X‐ray radiation, and changes in polymer structure are revealed by immersing the film in a solvent that dissolves the shortest chains. The experiments are implemented with high throughput using the standard beam line instrumentation and a typical GIXS configuration. The extent of damage (at a fixed radiation dose) depends on a range of intrinsic material properties and experimental variables, including the polymer chemistry and molecular weight, exposure environment, film thickness, and angle of incidence. The solubility switch for common polymers is detected within 10–60 s at ambient temperature, and we verified that this first indication of damage corresponds with the onset of network formation in glassy polystyrene and a loss of crystallinity in polyalkylthiophenes. Therefore, grazing‐incidence X‐ray “patterning” offers an efficient approach to determine the appropriate data acquisition times for any GIXS experiment. © 2016 Wiley Periodicals, Inc. J. Polym. Sci., Part B: Polym. Phys. 2016, 54, 1074–1086
We present a microfluidic immunoassay platform based on the use of linear microretroreflectors embedded in a transparent polymer layer as an optical sensing surface, and micron-sized magnetic particles as light-blocking labels. Retroreflectors return light directly to its source and are highly detectable using inexpensive optics. The analyte is immuno-magnetically pre-concentrated from a sample and then captured on an antibody-modified microfluidic substrate comprised of embedded microretroreflectors, thereby blocking reflected light. Fluidic force discrimination is used to increase specificity of the assay, following which a difference imaging algorithm that can see single 3 μm magnetic particles without optical calibration is used to detect and quantify signal intensity from each sub-array of retroreflectors. We demonstrate the utility of embedded microretroreflectors as a new sensing modality through a proof-of-concept immunoassay for a small, obligate intracellular bacterial pathogen, Rickettsia conorii, the causative agent of Mediterranean Spotted Fever. The combination of large sensing area, optimized surface chemistry and microfluidic protocols, automated image capture and analysis, and high sensitivity of the difference imaging results in a sensitive immunoassay with a limit of detection of roughly 4000 R. conorii per mL.
Nanopantography, a massively parallel nanopatterning method over large areas, was previously shown to be capable of printing 10 nm features in silicon, using an array of 1000 nm-diameter electrostatic lenses, fabricated on the substrate, to focus beamlets of a broad area ion beam on selected regions of the substrate. In the present study, using lens dimensional scaling optimized by computer simulation, and reduction in the ion beam image size and energy dispersion, the resolution of nanopantography was dramatically improved, allowing features as small as 3 nm to be etched into Si.
Point-of-care detection of pathogens is medically valuable but poses challenging trade-offs between instrument complexity and clinical and analytical sensitivity. Here we introduce a diagnostic platform utilizing lithographically fabricated micron-scale forms of cubic retroreflectors, arguably one of the most optically detectable human artifacts, as reporter labels for use in sensitive immunoassays. We demonstrate the applicability of this novel optical label in a simple assay format in which retroreflector cubes are first mixed with the sample. The cubes are then allowed to settle onto an immuno-capture surface, followed by inversion for gravity-driven removal of nonspecifically bound cubes. Cubes bridged to the capture surface by the analyte are detected using inexpensive, low-numerical aperture optics. For model bacterial and viral pathogens, sensitivity in 10% human serum was found to be 10(4) bacterial cells/mL and 10(4) virus particles/mL, consistent with clinical utility.
A high-throughput optical biosensing technique is proposed and demonstrated. This hybrid technique combines optical transmission of nanoholes with colorimetric silver staining. The size and spacing of the nanoholes are chosen so that individual nanoholes can be independently resolved in massive parallel using an ordinary transmission optical microscope, and, in place of determining a spectral shift, the brightness of each nanohole is recorded to greatly simplify the readout. Each nanohole then acts as an independent sensor, and the blocking of nanohole optical transmission by enzymatic silver staining defines the specific detection of a biological agent. Nearly 10000 nanoholes can be simultaneously monitored under the field of view of a typical microscope. As an initial proof of concept, biotinylated lysozyme (biotin-HEL) was used as a model analyte, giving a detection limit as low as 0.1 ng/mL.