The National Diagnostic Working Group (NDWG) has led the effort to fully exploit the major inertial confinement fusion/high-energy density facilities in the US with the best available diagnostics. These diagnostics provide key data used to falsify early theories for ignition and suggest new theories, recently leading to an experiment that exceeds the Lawson condition required for ignition. The factors contributing to the success of the NDWG, collaboration and scope evolution, and the methods of accomplishment of the NDWG are discussed in this Review. Examples of collaborations in neutron and gamma spectroscopy, x-ray and neutron imaging, x-ray spectroscopy, and deep-ultraviolet Thomson scattering are given. An abbreviated history of the multi-decade collaborations and the present semiformal management framework is given together with the latest National Diagnostic Plan.
BACKGROUNDObservational studies have suggested an inverse association between low serum 25-hydroxyvitamin D [25(OH)D] concentrations and development of type 2 diabetes. High-quality trials are required to test the hypothesis that vitamin D is a direct contributor to type 2 diabetes pathogenesis.OBJECTIVEThe purpose of this double-blind randomized placebo-controlled trial was to investigate the effect of vitamin D3 supplementation on insulin resistance (IR) and β-cell function in people with prediabetes and suboptimal vitamin D status (<50 nmol/L).METHODSSixty-six individuals were randomly assigned to receive 3000 IU (75 µg) vitamin D3 or placebo daily for 26 wk. Compliance was monitored by pill count and change in serum 25(OH)D concentration using LC-MS. The primary endpoint was between-group difference in change in IR assessed using a 2-step euglycemic-hyperinsulinemic clamp combined with infusion of tritiated glucose. An oral-glucose-tolerance test was performed pre- and postintervention to calculate indices of β-cell function. Between-group comparisons were made using ANCOVA.RESULTSIn total, 64 participants completed the study. Baseline serum 25(OH)D concentrations in the vitamin D3 and placebo group were 30.7 and 30.0 nmol/L, with status increasing by 70.5 nmol/L and 5.3 nmol/L, respectively (between-group difference in vitamin D: 65.8 nmol/L; 95% CI: 54.2, 77.3 nmol/L; P < 0.01), after supplementation. There was no difference between groups in measures of whole-body, peripheral, or hepatic IR or in any measure of glycemic control or β-cell function.CONCLUSIONThis study employed a robust assessment of IR and β-cell function and targeted a high-risk population with low 25(OH)D status at baseline and found that vitamin D3 supplementation had no effect on insulin action in people with prediabetes.This trial was registered on clinicaltrials.gov as NCT01889810.
Since X-ray diffraction is the definitive method for identifying crystalline phases of a material, it is an important technique for probing high-energy-density materials during laser-driven compression experiments. We are developing a design for collecting several x-ray diffraction datasets during a single laser-driven experiment, with a goal of achieving temporal resolution better than 1 ns. The design combines x-ray streak cameras, for a continuous temporal record of diffraction, with fast x-ray imagers, to collect several diffraction patterns with sufficient solid angle range and resolution to identify crystalline texture. Here we describe the status of the conceptual design, highlighting tradeoffs in the design process.
Crystal x-ray imaging is frequently used in inertial confinement fusion and laser-plasma interaction applications as it has advantages compared to pinhole imaging, such as higher signal throughput, better achievable spatial resolution, and chromatic selection. However, currently used x-ray detectors are only able to obtain a single time resolved image per crystal. The dilation aided single-line-of-sight x-ray camera described here was designed for the National Ignition Facility (NIF) and combines two recent diagnostic developments, the pulse dilation principle used in the dilation x-ray imager and a ns-scale multi-frame camera that uses a hold and readout circuit for each pixel. This enables multiple images to be taken from a single-line-of-sight with high spatial and temporal resolution. At the moment, the instrument can record two single-line-of-sight images with spatial and temporal resolution of 35 μm and down to 35 ps, respectively, with a planned upgrade doubling the number of images to four. Here we present the dilation aided single-line-of-sight camera for the NIF, including the x-ray characterization measurements obtained at the COMET laser, as well as the results from the initial timing shot on the NIF.
Supra-thermal (>100 keV) electrons generated by laser plasma interactions can be detrimental to the performance of ignition experiments conducted on the National Ignition Facility (NIF). On a NIF shot, the amount of electrons is estimated by measuring the hard X-rays passing through the hohlraum wall. The primary sources of hot electrons in a hohlraum are Stimulated Raman Scattering (SRS) and two plasmon decay (TPD). While SRS is well diagnosed on the NIF, there has been no diagnosis of TPD. We have designed and implemented a new diagnostic to characterize the time history of TPD on the NIF. The instrument provides a time resolved measurement of the 3/2 ω harmonic emission which is indicative of the presence of TPD. We describe the diagnostic setup, calibration, and the preliminary results obtained on NIF hohlraum experiments. We find evidence of a correlation between measured hard X-rays generated from the hot electron bremsstrahlung and the TPD emission.
Preparation of case reports during student attachments has the attraction of reflecting real life clinical practice, but lacks standardisation when used in summative assessment. This study examined the occurrence and nature of feedback after the introduction of a new system of formative case reports in Third Year clinical attachments. Quantitative and qualitative methods were used to compare the new system to previous practice. Comparison of questionnaire responses demonstrated more and earlier feedback in the New Third Year, which was likely to be delivered at a meeting rather than as written comment. In the New Third Year, the quality of feedback was better and several markers of high quality feedback were rated more highly. There was no difference, however, in students' confidence in their ability to assess patients. The qualitative data from the New Third Year documented much excellent feedback but also examples of poor practice as well as inconsistency of advice. In conclusion, a relatively simple intervention effected radical changes to feedback practice and attitudes, although it is not known if the clinical skills of students improved.
In inertial confinement fusion (ICF) experiments on the National Ignition Facility (NIF), measurements of average ion temperature using DT neutron time of flight broadening and of DD neutrons do not show the same apparent temperature. Some of this may be due to time and space dependent temperature profiles in the imploding capsule which are not taken into account in the analysis. As such, we are attempting to measure the electron temperature by recording the free-free electron-ion scattering-spectrum from the tail of the Maxwellian temperature distribution. This will be accomplished with the new NIF Continuum Spectrometer (ConSpec) which spans the x-ray range of 20 keV to 30 keV (where any opacity corrections from the remaining mass of the ablator shell are negligible) and will be sensitive to temperatures between ∼ 3 keV and 6 keV. The optical design of the ConSpec is designed to be adaptable to an x-ray streak camera to record time resolved free-free electron continuum spectra for direct measurement of the dT/dt evolution across the burn width of a DT plasma. The spectrometer is a conically bent Bragg crystal in a focusing geometry that allows for the dispersion plane to be perpendicular to the spectrometer axis. Additionally, to address the spatial temperature dependence, both time integrated and time resolved pinhole and penumbral imaging will be provided along the same polar angle. The optical and mechanical design of the instrument is presented along with estimates for the dispersion, solid angle, photometric sensitivity, and performance.
Laser driven inertial confinement fusion (ICF) plasmas typically have burn durations on the order of 100 ps. Time resolved imaging of the x-ray self emission during the hot spot formation is an important diagnostic tool which gives information on implosion symmetry, transient features and stagnation time. Traditional x-ray gated imagers for ICF use microchannel plate detectors to obtain gate widths of 40-100 ps. The development of electron pulse-dilation imaging has enabled a 10X improvement in temporal resolution over legacy instruments. In this technique, the incoming x-ray image is converted to electrons at a photocathode. The electrons are accelerated with a time-varying potential that leads to temporal expansion as the electron signal transits the tube. This expanded signal is recorded with a gated detector and the effective temporal resolution of the composite system can be as low as several picoseconds. An instrument based on this principle, known as the Dilation X-ray Imager (DIXI) has been constructed and fielded at the National Ignition Facility. Design features and experimental results from DIXI will be presented.
Compton radiography provides a means to measure the integrity, ρR and symmetry of the DT fuel in an inertial confinement fusion implosion near peak compression. Upcoming experiments at the National Ignition Facility will use the ARC (Advanced Radiography Capability) laser to drive backlighter sources for Compton radiography experiments and will use the newly commissioned AXIS (ARC X-ray Imaging System) instrument as the detector. AXIS uses a dual-MCP (micro-channel plate) to provide gating and high DQE at the 40-200 keV x-ray range required for Compton radiography, but introduces many effects that contribute to the spatial resolution. Experiments were performed at energies relevant to Compton radiography to begin characterization of the spatial resolution of the AXIS diagnostic.
Abstract At the completion of the National Ignition Campaign (NIC), the National Ignition Facility (NIF) had about 36 different types of diagnostics. These were based on several decades of development on Nova and OMEGA and involved the whole U.S. inertial confinement fusion community. In 1994, the Joint Central Diagnostic Team documented a plan for a limited set of NIF diagnostics in the NIF Conceptual Design Report. Two decades later, these diagnostics, and many others, were installed workhorse tools for all users of NIF. We give a short description of each of the 36 different types of NIC diagnostics grouped by the function of the diagnostics, namely, target drive, target response and target assembly, stagnation, and burn. A comparison of NIF diagnostics with the Nova diagnostics shows that the NIF diagnostic capability is broadly equivalent to that of Nova in 1999. Although NIF diagnostics have a much greater degree of automation and rigor than Nova’s, new diagnostics are limited such as the higher-speed X-ray imager. Recommendations for future diagnostics on the NIF are discussed.
A novel x-ray imager, which takes time-resolved gated images along a single line-of-sight, has been successfully implemented at the National Ignition Facility (NIF). This Gated Laser Entrance Hole diagnostic, G-LEH, incorporates a high-speed multi-frame CMOS x-ray imager developed by Sandia National Laboratories to upgrade the existing Static X-ray Imager diagnostic at NIF. The new diagnostic is capable of capturing two laser-entrance-hole images per shot on its 1024 × 448 pixels photo-detector array, with integration times as short as 1.6 ns per frame. Since its implementation on NIF, the G-LEH diagnostic has successfully acquired images from various experimental campaigns, providing critical new information for understanding the hohlraum performance in inertial confinement fusion (ICF) experiments, such as the size of the laser entrance hole vs. time, the growth of the laser-heated gold plasma bubble, the change in brightness of inner beam spots due to time-varying cross beam energy transfer, and plasma instability growth near the hohlraum wall.
CONTEXT:In observational studies, low serum 25-hydroxyvitamin D (25-OHD) concentration is associated with an increased risk of type 2 diabetes mellitus (DM). Increasing serum 25-OHD may have beneficial effects on insulin resistance or beta-cell function. Cross-sectional studies utilizing suboptimal methods for assessment of insulin sensitivity and serum 25-OHD concentration provide conflicting results. OBJECTIVE:This study examined the relationship between serum 25-OHD concentration and insulin resistance in healthy overweight individuals at increased risk of cardiovascular disease, using optimal assessment techniques. METHODS:A total of 92 subjects (mean age 56·0, SD 6·0 years), who were healthy but overweight (mean body mass index 30·9, SD 2·3 kg/m(2) ), underwent assessments of insulin sensitivity (two-step euglycaemic hyperinsulinaemic clamp, HOMA2-IR), beta-cell function (HOMA2%B), serum 25-OHD concentration and body composition (DEXA). RESULTS:Mean total 25-OHD concentration was 32·2, range 21·8-46·6 nmol/l. No association was demonstrated between serum 25-OHD concentration and insulin resistance. CONCLUSIONS:In this study using optimal assessment techniques to measure 25-OHD concentration, insulin sensitivity and body composition, there was no association between serum 25-OHD concentration and insulin resistance in healthy, overweight individuals at high risk of developing cardiovascular disease. This study suggests the documented inverse association between serum 25-OHD concentration and risk of type 2 DM is not mediated by a relationship between serum 25-OHD concentration and insulin resistance.
A new streaked soft x-ray imager has been designed for use on high energy-density (HED) physics experiments at the National Ignition Facility based at the Lawrence Livermore National Laboratory. This streaked imager uses a slit aperture, single shallow angle reflection from a nickel mirror, and soft x-ray filtering to, when coupled to one of the NIF's x-ray streak cameras, record a 4× magnification, one-dimensional image of an x-ray source with a spatial resolution of less than 90 μm. The energy band pass produced depends upon the filter material used; for the first qualification shots, vanadium and silver-on-titanium filters were used to gate on photon energy ranges of approximately 300-510 eV and 200-400 eV, respectively. A two-channel version of the snout is available for x-ray sources up to 1 mm and a single-channel is available for larger sources up to 3 mm. Both the one and two-channel variants have been qualified on quartz wire and HED physics target shots.