Background Cardiac tamponade is a serious complication of atrial fibrillation (AF) ablation, usually periprocedural. Delayed cardiac tamponade (DCT) is a rare but life-threatening complication. Case Summary A 75-year-old woman presented in shock 16 days after AF ablation including vein of Marshall ethanol infusion. Early postprocedural echocardiography showed no effusion. Pericardiocentesis drained 1,050 mL of hematic effusion with rapid stabilization. Anticoagulation was resumed at 48 hours. The patient remained well at 6-month follow-up. Discussion Most tamponades occur intraoperatively or immediately after the procedure; delayed presentations are uncommon. In the setting of vein of Marshall ethanol infusion, both mechanical injury and inflammatory processes may predispose to DCT. Normal early imaging does not exclude this complication, underscoring the need for vigilance and patient education. Conclusions Awareness of DCT is essential, because patients may appear stable at discharge yet later present in shock. Clinicians should suspect tamponade in any postablation patient with unexplained deterioration, as prompt recognition and drainage can be lifesaving. Take-Home Messages Delayed cardiac tamponade, although rare, may present days to weeks after AF ablation, even with normal early postprocedural imaging. Vigilance and patient education are critical, because prompt recognition and drainage of tamponade are lifesaving.
Background Cryoballoon ablation is a widely used single-shot technique for pulmonary vein isolation (PVI) in the treatment of paroxysmal atrial fibrillation (AF). Procedural endpoints ensuring maximal PVI durability are important. Objective To assess the performance of cryoablation procedural markers to predict long-term PVI. Methods In a single center, consecutive patients who underwent redo ablation with high-density mapping for symptomatic AF recurrence after cryoballoon ablation were included and cryoballoon procedural data were collected, including temperature values at 30 and 60 s, time to isolation, nadir temperature and the velocity of temperature decline estimated with the temperature/time catch-up point (T2T-Catch-Up) defined as positive when the freeze temperature in minus degree equals the time in seconds after cryoablation initiation (e.g. − 15 °C in the first 15 s of the ablation impulse). Results 47 patients (62% male; 58.3 ± 11.2 years) were included. Overall, 38 (80.9%) patients had ≥ 1 reconnected PV. Among 186 PVs, 56 (30.1%; 1.2 per patient on average) were reconnected. Univariate analysis revealed T2T-Catch-Up in 103 (56%) and more frequent in durably isolated than in reconnected PVs (93 [72%] vs 10 [19%], p < 0.0001). Among binary endpoints, T2T-Catch-Up had the highest specificity (82%) and predictive value for durable PVI at redo ablation (90%). In multivariable analyses, absence of T2T-Catch-Up (Odds-ratio 0.12, 95% CI [0.05–0.31], p < 0.0001) and right superior PV (Odds-ratio 3.14, 95% CI [1.27–7.74], p = 0.01) were the only variables independently associated with PV reconnection. Conclusion T2T-Catch-Up, a new and simple cryoballoon procedural endpoint demonstrated excellent predictive value and strong statistical association with durable PVI. Graphical abstract
Aims—Electrocardiography (ECG) and echocardiographic left atrial (LA) parameters may be helpful to assess the risk of atrial fibrillation (AF) in embolic stroke of unknown etiology (ESUS) and could therefore guide intensity of ECG monitoring. Methods—1153 consecutive patients with ischemic stroke or transient ischemic attack (TIA) were analyzed. An internal loop recorder (ILR) was implanted in 104 consecutive patients with ESUS. Multiple morphologic P-wave parameters in baseline 12-channel ECG and echocardiographic LA parameters were measured and analyzed in patients with and without ILR-detected AF. Using logistic regression, we evaluated the predictive value of several ECG parameters and LA dimensions on the occurrence of AF. Results—In 20 of 104 (19%) patients, AF was diagnosed by ILR during a mean monitoring time of 575 (IQR 470–580) days. Patients with AF were significantly older (72 (67–75) vs. 60 (52–72) years; p = 0.001) and premature atrial contractions (PAC) were more frequently observed (40% vs. 2%; p < 0.001) during baseline ECG. All morphologic P-wave parameters did not show a significant difference between groups. There was a non-significant trend towards a larger LA volume index (31 (24–36) vs. 29 (25–37) mL/m2; p = 0.09) in AF patients. Conclusions—Age and PAC are independently associated with incident AF in ESUS and could be used as markers for selecting patients that may benefit from more extensive rhythm monitoring or ILR implantation. In our consecutive cohort of patients with ESUS, neither morphological P-wave parameters nor LA size were predictive of AF.
Background: Left atrial posterior wall isolation (LAPWI) may improve rhythm control in addition to pulmonary vein isolation (PVI) in persistent atrial fibrillation (persAF) patients undergoing catheter ablation (CA). However, LAPWI may be challenging when using thermal energy sources. Objective: This study aimed to investigate the efficacy and safety of LAPWI performed by non-thermal pulsed field ablation (PFA) in CA for persAF. Methods: Consecutive persAF patients from two German centers were prospectively enrolled. There were two study cohorts: (1) the LAPWI cohort, which included PFA-guided (re-)PVI with LAPWI for first-time and/or repeat ablation procedures; and (2) a comparative persAF cohort with a PFA PVI-only approach without LAPWI for first-time ablation within the same timeframe. Patients were followed up by routine Holter ECGs. Results: In total, 79 persistent AF patients were included in the study: 59/79 patients were enrolled in the LAPWI cohort, including 16/59 index (27%) and 43/59 repeat ablation procedures (73%). Sixteen patients (16/79; 21%) were in the PVI-only cohort without LAPWI. Of the patients treated with LAPWI, procedure time and fluoroscopy time was 91 ± 30 min and 15 ± 7 min, respectively. The acute PVI rate was 100% in all first-time ablation patients (32 patients (16 PVI only, 16 PVI plus LAPWI), 196/196 PVs). Of the 43 re-do patients in the LAPWI cohort, re-PVI was necessary in 33% (14/43) of patients (27 PVs; 1.9 PV per-patient); in 67% (29/43), all PVs were isolated, and antral ablation of the PV ostia was performed in 48% (14/29). LAPWI was performed successfully in all 59 (100%) patients of the LAPWI cohort. Two minor complications occurred. No esophageal lesion was detected in the LAPWI cohort (n = 33/59 (56%) patients underwent endoscopy). After 354 ± 197 days of follow-up, freedom from atrial arrhythmias was 79.3% (95-CI: 62–95%) in the complete LAPWI cohort (n = 14/59 (24%) on AAD: class Ic n = 9, class III n = 5). There was no difference regarding acute procedural and clinical outcome compared to the PVI-only cohort. Conclusion: LAPWI guided by PFA is feasible and safe in patients undergoing CA for persAF and shows favorable outcomes. In the context of durable PVI, PFA-guided LAPWI may be an effective adjunctive treatment option.
Introduction: The long-QT syndrome (LQTS) is the most common ion channelopathy, typically presenting with a prolonged QT interval and clinical symptoms such as syncope or sudden cardiac death. Patients may present with a concealed phenotype making the diagnosis challenging. Correctly diagnosing at-risk patients is pivotal to starting early preventive treatment. Objective: Identification of congenital and often concealed LQTS by utilizing novel deep learning network architectures, which are specifically designed for multichannel time series and therefore particularly suitable for ECG data. Design and Results: A retrospective artificial intelligence (AI)-based analysis was performed using a 12-lead ECG of genetically confirmed LQTS (n = 124), including 41 patients with a concealed LQTS (33%), and validated against a control cohort (n = 161 of patients) without known LQTS or without QT-prolonging drug treatment but any other cardiovascular disease. The performance of a fully convolutional network (FCN) used in prior studies was compared with a different, novel convolutional neural network model (XceptionTime). We found that the XceptionTime model was able to achieve a higher balanced accuracy score (91.8%) than the associated FCN metric (83.6%), indicating improved prediction possibilities of novel AI architectures. The predictive accuracy prevailed independently of age and QTc parameters. Conclusions: In this study, the XceptionTime model outperformed the FCN model for LQTS patients with even better results than in prior studies. Even when a patient cohort with cardiovascular comorbidities is used. AI-based ECG analysis is a promising step for correct LQTS patient identification, especially if common diagnostic measures might be misleading.
BACKGROUND:Left atrial tachycardias (LAT) are a well-known outcome of pulmonary vein isolation (PVI). Few data are available on whether the catheter used to perform PVI influences the incidence, as well as the characteristics of post PVI LAT. We present data on LAT following PVI by the following three ablation technologies: (1) phased multi-electrode radiofrequency catheter (PVAC), (2) irrigated single-tip catheter (iRF), and (3) cryoballoon ablation.METHODS:Using a prospectively designed single-center database, we analyzed 650 patients (300 iRF, 150 PVAC, and 200 cryoballoon) with paroxysmal (n = 401) and persistent atrial fibrillation (AF), who underwent their first PVI at our center.RESULTS:The three populations were comparable in their baseline characteristics; however, the cryoballoon group comprised a higher percentage of patients with persistent AF (p = 0.05). The LAT rates were 3.7% in the iRF group (mean follow-up 22 ± 14 months), 0.7% in the PVAC group (mean follow-up 21 ± 14 months), and 4% in the cryoballoon group (mean follow-up 15 ± 8 months). The predominant mechanism of LAT was macro-reentrant tachycardia. Reconnection of at least one pulmonary vein was observed in 87% of the patients who underwent 3D mapping. No predictors for LAT occurrence were identified.CONCLUSION:The occurrence of LAT post PVI is rare; the predominant mechanism was macro-reentrant tachycardia. Reconnection of at least one pulmonary vein was observed in nearly all the LAT patients. In our retrospective analysis, the lowest rate of LAT was observed with the PVAC. No predictors for LAT occurrence were identified.
BACKGROUND:Several case reports have suggested an increased risk of sudden cardiac death due to energy drinks. Therefore, the purpose of this study was to assess acute electrophysiologic effects of caffeine and taurine, two of the main ingredients of energy drinks, in an experimental whole-heart model.METHODS AND RESULTS:Twenty-five rabbit hearts were excised, retrogradely perfused, and assigned to two groups. Hearts were perfused with caffeine (2, 10, and 50 µM) or taurine (2, 10, and 50 µM) after generating baseline data. Eight monophasic action potentials and electrocardiography recordings showed a significant abbreviation of action potential duration (APD90 ), QT interval, and effective refractory periods (ERP) after caffeine treatment. With taurine, cardiac repolarization duration and ERP were significantly shortened. A ventricular vulnerability was assessed by a predefined pacing protocol. With caffeine, we observed a trend towards more ventricular arrhythmias in a dose-dependent manner. After treatment with taurine, significantly more episodes of ventricular arrhythmias occurred.CONCLUSION:In this experimental whole-heart study, treatment with caffeine and taurine provoked ventricular arrhythmias. The underlying mechanism was an abbreviation of cardiac repolarizations and effective refractory periods that may facilitate re-entry and thereby provokes arrhythmias. These findings help to understand the potentially hazardous and fatal outcomes after intoxication with energy drinks.
Background: Previous studies report conflicting data regarding anti- or pmarrhythmic effects of sacubitril. Aim of this study was to assess the impact of acute sacubitril treatment in different arrhythmia models. Methods: Sacubitril was administered (3, 5, 10 mu M) in 12 isolated rabbit hearts. Further 12 hearts were treated with erythromycin to simulate long-QT-syndrome-2 (LQT2). Other 12 hearts were perfused with veratridine to mimic long-QT-syndrome-3 (LQT3). Both LQT-groups were treated with sacubitril (5 mu M) additionally. Ventricular vulnerability was assessed by a pacing protocol. AV-blocked bradycardic hearts were perfused with a hypokalemic solution to trigger torsade de pointes (TdP). In further 13 hearts, AF was induced by a combination of acetylcholine and isopmterenol and sacubitril (5 mu M) was added afterwards. Results: With sacubitril, action potential duration (APD) was abbreviated whereas spatial dispersion of repolarisation (SDR) remained stable. In both LQT groups, APD and SDR were increased. Infusion of sacubitril reduced APD (- 21 ms, p < 0.01) and SDR (- 8 ms) in the LQT2-group and did not alter APD (+2 ms) but reduced SDR (-19 ms, p < 0.01) in the LQT3-group. Ventricular vulnerability was not altered by sacubitril. No TdP were observed with sacubitril or under baseline conditions in any group. Sacubitril significantly suppressed TdP in the LQT2-group (3 vs. 43 episodes, p < 0.05) but not in the LQT3-group (10 vs. 16 episodes, p = ns). Sacubitril reduced inducibility of AF (9 vs. 31 episodes). Conclusion: Sacubitril abbreviated APD. In addition, sacubitril exhibits potential antiarrhythmic effects in LQT2 and may be beneficial in LQT3 and AF.
Background: Decision-making in primary prevention is not always trivial and many clinical scenarios are not reflected in current guidelines. To help evaluate a patient’s individual risk, a new score to predict the benefit of an implantable defibrillator (ICD) for primary prevention, the MADIT-ICD benefit score, has recently been proposed. The score tries to predict occurrence of ventricular arrhythmias and non-arrhythmic death based on data from four previous MADIT trials. We aimed at examining its usefulness in a large single-center register of S-ICD patients with various underlying cardiomyopathies. Methods and results: All S-ICD patients with a primary preventive indication for ICD implantation from our large single-center database were included in the analysis (n = 173). During a follow-up of 1227 ± 978 days, 27 patients developed sustained ventricular arrhythmias, while 6 patients died for non-arrhythmic reasons. There was a significant correlation for patients with ischemic cardiomyopathy (ICM) (n = 29, p = 0.04) to the occurrence of ventricular arrhythmia. However, the occurrence of ventricular arrhythmias could not sufficiently be predicted by the MADIT-ICD VT/VF score (p = 0.3) in patients with (n = 142, p = 0.19) as well as patients without structural heart disease (n = 31, p = 0.88) and patients with LV-EF < 35%. Of the risk factors included in the risk score calculation, only non-sustained ventricular tachycardias were significantly associated with sustained ventricular arrhythmias (p = 0.02). Of note, non-arrhythmic death could effectively be predicted by the proposed non-arrhythmic mortality score as part of the benefit score (p = 0.001, r = 0.3) also mainly driven by ICM patients. Age, diabetes mellitus, and a BMI < 23 kg/m2 were key predictors of non-arrhythmic death implemented in the score. Conclusion: The MADIT-ICD benefit score adds a new option to evaluate expected benefit of ICD implantation for primary prevention. In a large S-ICD cohort of primary prevention, the value of the score was limited to patients with ischemic cardiomyopathy. Future research should evaluate the performance of the score in different subgroups and compare it to other risk scores to assess its value for daily clinical practice.
Introduction: Hormone-mediated therapies are on the rise and are key therapies in the treatment of some of the most common cancer entities. Proarrhythmic effects have been described in patients treated with SERMs while little to none is known about the electrophysiological effects of the potentially less arrhythmogenic selective estrogen receptor degraders. Methods: Twenty hearts of female New Zealand White rabbits were excised and retrogradely perfused employing a Langendorff setup. An electrophysiology study was performed to obtain CL-dependent action potential duration at 90% of repolarization (APD90), QT interval, effective refractory period (ERP), and post-repolarization refractoriness (PRR = ERP-APD90). After generating baseline data, the hearts were assigned to two groups and perfused with (n = 10) increasing doses of fulvestrant (1 µM and 5 µM; n = 10) or tamoxifen (2.5 µM and 7.5 µM; n = 10), and the protocol was repeated again. Results: Fulvestrant led to a decrease in APD90 and QT interval and an increased PRR. The inducibility of ventricular tachycardia (VT) episodes was unaltered. Tamoxifen showed similar effects, resulting in a shortened APD90 and QT interval and no increased VT incidence in the setting of a prolonged PRR. Conclusion: The present study shows no acute proarrhythmic effect of tamoxifen and fulvestrant in an established whole heart model when employing clinically relevant concentrations.
1. Introduction: Pulmonary vein isolation (PVI) is an established procedure used to achieve rhythm control in atrial fibrillation (AF). In obese patients (pts), in whom AF occurs more frequently, a reduced effectiveness of PVI has been observed. Therefore, this study’s aim was to compare the long-term efficacy of PVI between obese and non-obese patients. 2. Methods: We enrolled 111 consecutive pts with a body mass index (BMI) of >30 kg/m2 undergoing PVI from our large registry. Procedural data and outcomes were compared with a matched group of 115 non-obese PVI pts and the long-term outcomes were analyzed. 3. Results: Overall follow-up duration was 314 patient-years in the obese and 378 patient-years in the non-obese group. The follow-up rate was 71% in the obese and 76% in the non-obese group. In both groups, their AF-characteristics did not differ significantly, while known risk factors were significantly more prevalent in the obese group. Procedural characteristics were similar in both groups. During follow-up, the obese pts demonstrated significant weight loss compared to the non-obese pts, while at the same time, the overall recurrence rate during follow-up did not differ significantly between both groups (obese: 39.2% and non-obese: 43.7%). PVI related and long-term complications were comparable between both groups. In the univariate analysis, obesity was not found to be associated with an increased AF recurrence risk. 4. Conclusion: These real-life data demonstrate that obese pts may not show higher AF recurrence rates after PVI compared to pts with normal body weight. Furthermore, PVI was found to be safe and effective in obese patients; thus, a BMI alone may not be a criterion for refusal of PVI.
Background Early repolarization pattern (ERP) has been associated with idiopathic ventricular fibrillation (IVF) and with cardiovascular mortality in the general population. As there is limited data about long- term outcome of IVF, the aim of our study was to observe ventricular arrhythmia (VA) recurrences in these patients and to identify a possible correlation of VA with ECG markers of early repolarization. Methods and results We investigated 56 consecutive IVF patients who received an implantable cardioverter-defibrillator for secondary prevention. ERP was defined as a J-point elevation ≥ 0.1 mV in two or more contiguous inferior or lateral leads. Markers of early repolarization were present in 32.1% of cases with a preponderance of QRS slurring (77.8%). During a mean follow-up of 41.2 months, 11 patients (19.6%) received in total 18 adequate ICD-therapies. VF was most the common cause for ICDtherapy (61.1%) but monomorphic VT also occurred in four patients. Presence of ERP was associated with a significant trend towards arrhythmia recurrences. 38.9% patients with ERP received appropriate ICD-therapies whereas only 10.5% of patients without ERP had arrhythmia recurrence ( p = 0.05). Inappropriate ICD-therapies occurred in seven patients (12.5%) with a non-significant trend towards a higher incidence in patients with a transvenous ICD ( p = 0.15). Conclusion A significant correlation between ERP and VA recurrences in patients with IVF could be observed. Though monomorphic VA also play a role in the studied IVF-population, our data support the use of the S-ICD in this collective. Graphical abstract
Background: The subcutaneous ICD (S-ICD) has developed as a valuable alternative to transvenous implantable cardioverter defibrillator (ICD) systems. However there are certain peculiarities which are immanent to the S-ICD and may limit its use. Besides oversensing the main issue is the missing option for antibradycardia pacing. To evaluate the actual need for pacing during follow-up and changes to transvenous ICD we analyzed our large tertiary centre registry and compared it with data from other large cohorts and trials. Methods and Results: We found out that in the 398 patients from our centre, there was a need for changing to a transvenous ICD in only 2 patients (0.5%) during a follow-up duration of almost 3 years. This rate was comparable to data obtained from other large data sets so that in the pooled analysis of almost 4000 patients the rate of bradycardia-associated complications was only 0.3%. Conclusions: The use of the S-ICD is safe in a variety of heart diseases and the need for antibradycardia stimulation is a very rare complication throughout many different large studies. Clinicians may take these results into account when opting for a certain ICD system and the S-ICD may be chosen more often also in elderly patients, in whom the risk for bradycardia is deemed higher.
Katheterablationen sind heute ein weit verbreitetes Verfahren zur Behandlung von Herzrhythmusstörungen. Hierfür sind genaue anatomische Kenntnisse sowohl im Vorfeld als auch während der Untersuchung erforderlich und eine wichtige Voraussetzung zur zielgerichteten Behandlung. Während zu Beginn der Ära von katheterinterventionellen Behandlungen die Fluoroskopie das einzige und gängige Visualisierungsmittel war, sind seit Mitte der 1990er Jahre kontinuierlich 3‑D-Mappingssysteme zur nichtfluoroskopischen Untersuchung von Patienten (weiter)entwickelt worden. Die sachgemäße Anwendung dieser 3‑D-Systeme, die Katheter nichtfluoroskopisch visualisieren und Arrhythmiemechanismen meist sehr detailliert identifizieren, leistet heute einen bedeutsamen Beitrag zur erfolgreichen katheterinterventionellen Behandlung von Rhythmusstörungen. Vor allem Patienten mit ventrikulären Arrhythmien sind jedoch nicht selten Träger elektronischer Devices wie Defibrillatoren oder teilweise hämodynamischen Unterstützungssystemen. Implantierbare Devices führen zu elektromagnetischen Interferenzen, die die Diagnostik und Behandlung im Rahmen elektrophysiologischen Untersuchungen und Ablationen erschweren können. Dieser Artikel diskutiert die Widrigkeiten und Erfahrungen in Zusammenhang mit magnetbasierten 3‑D-Systemen sowie implantierbaren elektromagnetisch aktiven „cardiac devices“.
Die Durchführung einer linksventrikulären Ablation setzt, wie bei grundsätzlich allen kardialen Interventionen, eine gute Kenntnis der kardialen Anatomie voraus. Ziel dieses Artikels ist es, eine Übersicht über die Anatomie des linken Ventrikels zu geben und komplexe klinisch relevante Strukturen aus einer untersucherzentrierten Perspektive zu charakterisieren. Neben den unterschiedlichen Zugangswegen, dem Trabekelwerk, dem linksventrikulären Ausflusstrakt und dem spezifischen Reizleitungssystem, sollen im Folgenden auch komplexe anatomische Strukturen wie die aortomitrale Kontinuität und der linksventrikuläre Summit erläutert und kartiert werden. Darüber hinaus bietet dieser Artikel mehrere klinische Fälle, die eine Verbindung zwischen EKG, Anatomie und Ablation ermöglichen sollen.
Atrioventricular nodal reentry tachycardia (AVNRT) is the most common regular supraventricular tachycardia (SVT). Slow pathway modification (SPM) is the accepted first line treatment with reported success rates around 95%. Information regarding possible predictors of AVNRT recurrence is scarce.Out of 4170 consecutive patients with SPM in our department from 1993-2018, we identified 78 patients (1.9%) receiving > 1 SPM (69% female, median age 50 years) with a recurrence of AVNRT after a successful SPM. We matched these patients for age, gender and number of radiofrequency applications during first SPM with 78 patients who received one successful SPM in our center without AVNRT recurrence. Both groups were analyzed for possible predictors of a recurrence of AVNRT during long-term follow-up. The recurrence group contained a significantly lower proportion of patients with an occurrence of junctional beats during SPM (69% versus 89%, P = 0.006). Moreover, significantly more cases of previously diagnosed atrial fibrillation/tachycardia (AF/AT; 21% versus 5%, P = 0.007) and inducible AF/AT during electrophysiology study (23% versus 6%, P = 0.006) were present in the recurrence group. While more than half of patients had a recurrence within the first year, in 20% symptoms reappeared ≥ 4 years after ablation.In a small percentage of patients, AVNRT recurs after an initially successful ablation. Interestingly, these patients had significantly fewer junctional beats during ablation and a higher rate of other (inducible) arrhythmias. AVNRT recurrence spanned a considerable timeframe and should remain a differential diagnosis, even years after ablation.
Supraventricular tachycardias (SVT) are often difficult to document due to their intermittent, short-lasting nature. Smartphone-based one-lead ECG monitors (sECG) were initially developed for the diagnosis of atrial fibrillation. No data have been published regarding their potential role in differentiating inappropiate sinus tachycardia (IST) from regular SVT. If cardiologists could distinguish IST from SVT in sECG, economic health care burden might be significantly reduced. We prospectively recruited 75 consecutive patients with known SVT undergoing an EP study. In all patients, four ECG were recorded: a sECG during SVT and during sinus tachycardia and respective 12-lead ECG. Two experienced electrophysiologists were blinded to the diagnoses and separately evaluated all ECG. Three hundred individual ECG were recorded in 75 patients (47 female, age 50 ± 18 years, BMI 26 ± 5 kg/m2, 60 AVNRT, 15 AVRT). The electrophysiologists’ blinded interpretation of sECG recordings showed a sensitivity of 89% and a specificity of 91% for the detection of SVT (interobserver agreement κ = 0.76). In high-quality sECG recordings (68%), sensitivity rose to 95% with a specificity of 92% (interobserver agreement of κ = 0.91). Specificity increased to 96% when both electrophysiologists agreed on the diagnosis. Respective 12-lead ECG had a sensitivity of 100% and specificity of 98% for the detection of SVT. A smartphone-based one-lead ECG monitor allows for differentiation of SVT from IST in about 90% of cases. These results should encourage cardiologists to integrate wearables into clinical practice, possibly reducing time to definitive diagnosis of an arrhythmia and unnecessary EP procedures. A smartphone-based one lead ECG device (panel A) can be used reliably to differentiate supraventricular tachycardia (panel B) from inappropriate sinus tachycardia when compared to a simultaneously conducted gold-standard electrophysiology study (panels C, D).
Background: Pulmonary vein isolation (PVI) and antiarrhythmic drug therapy are established treatment strategies to preserve sinus rhythm in atrial fibrillation (AF). However, the efficacy of both interventional and pharmaceutical therapy is still limited. Solid evidence suggests an important role of the cardiac sympathetic nervous system in AF. In this blinded, prospective observational study, we studied left ventricular cardiac sympathetic activity in patients treated with PVI and with antiarrhythmic drugs. Prospectively, Iodine-123-benzyl-guanidine single photon emission computer tomography (123I-mIBG-SPECT) was performed in a total of 23 patients with paroxysmal AF, who underwent PVI (n = 20) or received antiarrhythmic drug therapy only (n = 3), respectively. 123I-mIBG planar and SPECT/CT scans were performed before and 4 to 8 weeks after PVI (or initiation of drug therapy, respectively). For semiquantitative SPECT image analysis, attenuation-corrected early/late images were analyzed. Quantitative SPECT analysis was performed using the AHA 17-segment model of the left ventricle. Results: PVI with point-by-point radiofrequency ablation led to a significantly (p < 0.05) higher visual sympathetic innervation defect score when comparing pre-and post PVI. Newly emerging innervation deficits post PVI were localized predominantly in the inferior lateral wall. These findings were corroborated by semiquantitative SPECT analysis identifying inferolateral segments with a reduced tracer uptake in comparison to SPECT before PVI. Following PVI, patients with an AF relapse showed a different sympathetic innervation pattern compared to patients with sufficient rhythm control. Conclusions: PVI results in novel defects of cardiac sympathetic innervation. Differences in cardiac sympathetic innervation remodelling following PVI suggest an important role of the cardiac autonomous nervous system in the maintenance of sinus rhythm following PVI.
Background: Different electrocardiogram (ECG) findings are known to be independent predictors of clinical response to cardiac resynchronization therapy (CRT). It remains unknown how these findings influence very long-term prognosis. Methods and Results: A total of 102 consecutive patients (75 males, mean age 65 ± 10 years) referred to our center for CRT implantation had previously been included in this prospective observational study. The same patient group was now re-evaluated for death from all causes over a prolonged median follow-up of 10.3 years (interquartile range 9.4–12.5 years). During follow-up, 55 patients died, and 82% of the clinical non-responders (n = 23) and 44% of the responders (n = 79) were deceased. We screened for univariate associations and found QRS width during biventricular (BIV) pacing (p = 0.02), left ventricular (LV) pacing (p < 0.01), Δ LV paced–right ventricular (RV) paced (p = 0.03), age (p = 0.03), New York Heart Association (NYHA) class (p < 0.01), CHA2DS2-Vasc score (p < 0.01), glomerular filtration rate (p < 0.01), coronary artery disease (p < 0.01), non-ischemic cardiomyopathy (NICM) (p = 0.01), arterial hypertension (p < 0.01), NT-proBNP (p < 0.01), and clinical response to CRT (p < 0.01) to be significantly associated with mortality. In the multivariate analysis, NICM, the lower NYHA class, and smaller QRS width during BIV pacing were independent predictors of better outcomes. Conclusion: Our data show that QRS width duration during biventricular pacing, an ECG parameter easily obtainable during LV lead placement, is an independent predictor of mortality in a long-term follow-up. Our data add further evidence that NICM and lower NYHA class are independent predictors for better outcome after CRT implantation.
Introduction: Multiple studies have shown that left atrial (LA) enlargement is a strong predictor of poor outcome after catheter ablation of atrial fibrillation (AF). LA size is commonly approximated as the diameter in the parasternal long axis. It remains unknown whether more precise echocardiographic measurements of LA size allow for better correlation with outcome after pulmonary vein isolation (PVI). Methods and results: We performed a retrospective study of 131 consecutive patients (43 females, 60% paroxysmal AF, mean CHA2DS2-Vasc score 1.6, mean age 61 ± 12 years) referred for PVI. Measurements of the LA were carried out by a single observer in transthoracic echocardiograms (TTE) performed prior to ablation. We calculated diameter of the LA in the parasternal long axis (PLAX), LA area in the 2- as well as 4-Chamber (CH) view. LA volume was computed using the disc summation technique (LAV) and indexed to body surface area (LAVI). Procedural and follow-up data were gathered from a prospective AF database. Ablation was performed exclusively using the second generation cryoballoon by the same operators. Follow-up visits at 3, 6 and 12 months showed freedom from AF in 76%, 73% and 73% respectively. Mean values of LA calculations were LAPLAX: 37.9 mm ± 6.3 mm, 2CH area: 22.5 cm2 ± 6.7 cm2, 4CH area: 21.4 cm2 ± 5.5 cm2, LAV: 73.7 mL ± 26.1 mL and LAVI: 36.2 mL/m2 ± 12.7 mL/m2, respectively. C statistic revealed the best concordance of LAVI with outcome after 12 months (C = 0.67), LAV also exhibited a satisfactory value (C = 0.61) in comparison to surfaces in 2CH (C = 0.59) and 4CH (C = 0.57). PLAX showed the worst correlation (C = 0.51). Additionally, different binary logistic regression models identified three independent predictors of AF outcome after cryoballoon PVI: gender (OR = 0.95 per year; p = 0.01); LAV (OR = 1.3/10mL; p = 0.02) and LAVI (OR = 1.58/10 mL/m2; p = 0.02). In all models, PLAX and area measurements were not predictive. Conclusions: Our data add further to evidence that LA size lends itself well as a predictor of PVI outcome. LAVI and LAV were independently predictive of rhythm outcome after PVI. This did not hold true for more commonly used measurements, such as PLAX diameter and surfaces of the LA, irrespective of the view chosen.