Following a major upgrade, the two advanced detectors of the Laser Interferometer Gravitational-wave Observatory (LIGO) held their first observation run between September 2015 and January 2016.The product of observable volume and measurement time exceeded that of all previous runs within the first 16 days of coincident observation.On September 14th, 2015 the Advanced LIGO detectors observed the transient gravitational-wave signal GW150914, determined to be the coalescence of two black holes, launching the era of gravitational-wave astronomy.We present the main features of the detectors that enabled this observation.At its core Advanced LIGO is a multi-kilometer long Michelson interferometer employing optical resonators to enhance its sensitivity.Four very pure and homogeneous fused silica optics with excellent figure quality serve as the test masses.The displacement produced by the event GW150914 was one 200th of a proton radius.It was observed with a combined signal-to-noise ratio of 24 in coincidence by the two detectors.At full sensitivity, the Advanced LIGO detectors are designed to deliver another factor of three improvement in the signal-to-noise ratio for binary black hole systems similar in masses to GW150914.
The NASA Goddard Space Flight Center (GSFC) and its partners have broad experience in the alignment of flight optical instruments and spacecraft structures. Over decades, GSFC developed alignment capabilities and techniques for a variety of optical and aerospace applications. In this paper, we provide an overview of a subset of the capabilities and techniques used on several recent projects in a "toolbox" format. We discuss a range of applications, from small-scale optical alignment of sensors to mirror and bench examples that make use of various large-volume metrology techniques. We also discuss instruments and analytical tools.
X-ray optics is an essential component of every conceivable future x-ray observatory. Its astronomical utility is measured with two quantities: angular resolution and photon collecting area. The angular resolution determines the quality of its images and the photon collecting area determines the faintest sources it is capable of detecting and studying. Since it must be space-borne, the resources necessary to realize an x-ray mirror assembly, such as mass and volume, are at a premium. In this paper we report on a technology development program designed to advance four metrics that measure the capability of an x-ray mirror technology: (1) angular resolution, (2) mass per unit photon collecting area, (3) volume per unit photon collecting area, and (4) production cost per unit photon collecting area. We have adopted two approaches. The first approach uses the thermal slumping of thin glass sheets. It has advantages in mass, volume, and cost. The objective for this approach is improving its angular resolution. As of August 2013, we have been able to consistently build and test with x-ray beams modules that contain three co-aligned Wolter-I parabolic-hyperbolic mirror pairs, achieving a point spread function (PSF) of 11 arc-second half-power diameter (HPD), to be compared with the 17 arc-seconds we reported last year. If gravity distortion during x-ray tests is removed, these images would have a resolution of 9 arc-seconds, meeting requirements for a 10 arc-second flight mirror assembly. These modules have been subjected to a series of vibration, acoustic, and thermal vacuum tests. The second approach is polishing and light-weighting single crystal silicon, a material that is commercially available, inexpensive, and without internal stress. This approach has advantages in angular resolution, mass, and volume, and objective is reducing fabrication cost to make it financially feasible to fabricate the similar to 10(3) m(2) mirror area that would be required for a future major x-ray observatory. The overall objective of this technology program is to enable missions in the upcoming years with a 10 arc-second angular resolution, and missions with similar to 1 arc-second angular resolution in the 2020s.
The James Webb Space Telescope (JWST) relies on several innovations to complete its five year mission. One vital technology is microshutters, the programmable field selectors that enable the Near Infrared Spectrometer (NIRSpec) to perform multi-object spectroscopy. Mission success depends on acquiring spectra from large numbers of galaxies by positioning shutter slits over faint targets. Precise selection of faint targets requires field selectors that are both high in contrast and stable in position. We have developed test facilities to evaluate microshutter contrast and alignment stability at their 35K operating temperature. These facilities used a novel application of image registration algorithms to obtain non-contact, sub-micron measurements in cryogenic conditions. The cryogenic motion of the shutters was successfully characterized. Optical results also demonstrated that shutter contrast far exceeds the NIRSpec requirements. Our test program has concluded with the delivery of a flight-qualified field selection subsystem to the NIRSpec bench.
The James Webb Space Telescope (JWST) is the successor to the Hubble Space Telescope. JWST will be an infrared-optimized telescope, with an approximately 6.5 m diameter primary mirror, that is located at the Sun-Earth L2 Lagrange point. Three of JWST’s four science instruments use Teledyne HgCdTe HAWAII-2RG (H2RG) near infrared detector arrays. During 2010, the JWST Project noticed that a few of its 5 μm cutoff H2RG detectors were degrading during room temperature storage, and NASA chartered a “Detector Degradation Failure Review Board” (DD-FRB) to investigate. The DD-FRB determined that the root cause was a design flaw that allowed indium to interdiffuse with the gold contacts and migrate into the HgCdTe detector layer. Fortunately, Teledyne already had an improved design that eliminated this degradation mechanism. During early 2012, the improved H2RG design was qualified for flight and JWST began making additional H2RGs. In this article, we present the two public DD-FRB “Executive Summaries” that: (1) determined the root cause of the detector degradation and (2) defined tests to determine whether the existing detectors are qualified for flight. We supplement these with a brief introduction to H2RG detector arrays, some recent measurements showing that the performance of the improved design meets JWST requirements, and a discussion of how the JWST Project is using cryogenic storage to retard the degradation rate of the existing flight spare H2RGs.
Future x-ray astronomical missions, similar to the proposed International X-ray Observatory (IXO), will utilize replicated mirrors to reduce both mass and production costs. Accurately figured and measured molds (called mandrels) - on which the mirror substrates are thermally formed, replicating the surface of the mandrels - are essential to enable these missions. The Optics Branches of the Goddard Space Flight Center (GSFC) and Marshall Space Flight Center (MSFC) have developed fabrication processes along with metrologies that yield high-precision mandrels; and through the SBIR program, they encourage small businesses to attack parts of the remaining problems. The Goddard full-aperture mandrel polisher (the MPM-500) has been developed to a level where mandrel surfaces match the 1.5 arcsec HPD level allocation in a 5 arcsec telescope program. This paper reviews this current technology and describes a pilot program to design a suite of machine tools and process parameters capable of producing many hundreds of these precision objects. A major challenge is to keep mid-spatial frequency errors below 2 nm rms - a severe specification; but we must also note the factors which work to our advantage: e.g., how the figure departs from a pure cone by only one micron, and how the demanding figure specifications which apply in the axial direction are relaxed by an order of magnitude in the azimuthal. Careful study of other large optical fabrication programs in the light of these challenges and advantages has yielded a realistic plan for the economical production of mandrels that meet program requirements in both surface and quantity.
Image registration, or alignment of two or more images covering the same scenes or objects, is of great interest in many disciplines such as remote sensing, medical imaging, astronomy, and computer vision. In this paper, we introduce a new application of image registration algorithms. We demonstrate how through a wavelet based image registration algorithm, engineers can evaluate stability of Micro-Electro-Mechanical Systems (MEMS). In particular, we applied image registration algorithms to assess alignment stability of the MicroShutters Subsystem (MSS) of the Near Infrared Spectrograph (NIRSpec) instrument of the James Webb Space Telescope (JWST). This work introduces a new methodology for evaluating stability of MEMS devices to engineers as well as a new application of image registration algorithms to computer scientists.
SPS-DSPI software has been revised so that Goddard optical engineers can operate the instrument, instead of data programmers. The user interface has been improved to view the data collected by the SPS-DSPI, with a real-time mode and a play-back mode. The SPS-DSPI has been developed by NASA/GSFC to measure the temperature distortions of the primary-mirror backplane structure for the James Webb Space Telescope. It requires a team of computer specialists to run successfully, because, at the time of this reporting, it just finished the prototype stage. This software improvement will transition the instrument to become available for use by many programs that measure distortion
We present an overview update of the metrologic approach to be employed for the segmented mirror fabrication for the IXO soft x-ray telescope. We compare results achieved to date with mission requirements. This is discussed in terms of inherent capability versus in-practice capability of the metrology. We find that all the needed metrology equipment are in hand but that a number of the needed quantities remain too uncertain relative to mission requirements. This is driven by the mounting of the mirrors themselves. We then discuss some plans for addressing the mirror mounting issues. Finally, we also briefly discuss some promising mandrel metrology techniques.
The James Webb Space Telescope (JWST) Backplane Stability Test Article (BSTA) was developed to demonstrate large precision cryogenic structures' technology readiness for use in the JWST. The thermal stability of the BSTA was measured at cryogenic temperatures at the Marshall Space Flight Center (MSFC) X-Ray Calibration Facility (XRCF) and included nearly continuous measurements over a six-week period in the summer of 2006 covering the temperature range from ambient down to 30 Kusing a spatially phase-shifted digital speckle pattern interferometer (SPS-DSPI). The BSTA is a full size, one-sixth section of the JWST primary mirror backplane assembly (PMBA). The BSTA, measuring almost 3 m across, contains most of the prominent structural elements of the backplane and is to our knowledge the largest structure ever measured with SPS-DSPI at cryogenic conditions. The SPS-DSPI measured rigid body motion and deformations of BSTA to nanometer-level accuracy. The SPS-DSPI was developed specifically for the purposes of this test and other tests of large cryogenic structures for JWST.
Instantaneous phase shifting interferometry is key to successful development and testing of the large, deployable, cryogenic telescope for the James Webb Space Telescope (JWST) mission. Two new interferometers have been developed to meet the needs of the JWST program. Spatially Phase-Shifted Digital Speckle Pattern Interferometer (SPS-DSPI) was developed to verify structural deformations to nanometer level accuracy in large, deployable, lightweight, precision structures such as the JWST telescope primary mirror backplane. Multi- wavelength interferometer was developed to verify the performance of the segmented primary mirror at cryogenic temperatures. This paper discusses application of SPS-DSPI for measuring structural deformations in large composite structures at cryogenic temperatures. Additionally development of a multi-wavelength interferometer for verifying JWST OTE primary mirror performance at cryogenic temperatures will be discussed.
The Spatially Phase Shifted Digital Speckle Pattern Interferometer (SPS-DSPI) is a speckle pattern interferometer in which the four phase-shifted interferograms are captured simultaneously in a single image. Designed to measure thermal distortions of large matte-surfaced structures for the James Webb Space Telescope (JWST) program, this metrology instrument has been used in two major cryo-distortion tests. This report will describe how differences in the vibrational motions of the test objects necessitated changes in basic algorithms. The authors also report operational upgrades, quantification of uncertainty, and improvement of the software operability with a graphic interface. Results from the tests of the JWST test structures are discussed as illustration.
This report describes the facility, experimental methods, characterizations, and uncertainty analysis of the Cryo-Distortion Measurement Facility (CDMF) at the Goddard Space Flight Center (GSFC). This facility is designed to measure thermal distortions of structural elements as the temperature is lowered from 320K to below 40 K over multiple cycles, and is capable of unattended running and data logging. The first measurement is the change in length and any bending of composite tubes with Invar end-fittings. The CDMF includes a chamber that is efficiently cooled with two cryo-coolers (one single-stage and one two-stage) rather than with liquid cryogens. Five optical ports incorporate sapphire radiation shields - transparent to the interferometer - on each of two shrouds and a fused silica vacuum-port window. The change in length of composite tubes is monitored continuously with displacement-measuring interferometers; and the rotations, bending, and twisting are measured intermittently with theodolites and a surface-figure interferometer. Nickel-coated invar mirrors and attachment mechanisms were developed and qualified by test in the CDMF. The uncertainty in measurement of length change of 0.4 m tubes is currently estimated at 0.9 micrometers.
We present a method for the calibration of a spatially phase-shifted digital speckle pattern interferometer (SPS-DSPI), which was designed and built for the purpose of testing the James Webb space telescope (JWST) optical structures and related technology development structures. The need to measure dynamic deformations of large, diffuse structures to nanometer accuracy at cryogenic temperature is paramount in the characterization of a large diameter space and terrestrial based telescopes. The techniques described herein apply to any situation, in which high accuracy measurement of diffuse structures are required. The calibration of the instrument is done using a single-crystal silicon gauge. The gauge has four islands of different heights that change in a predictable manner as a function of temperature. The SPS-DSPI is used to measure the relative piston between the islands as the temperature of the gauge is changed. The measurement results are then compared with the theoretical changes in the height of the gauge islands. The maximum deviation of the measured rate of change of the relative piston in nm/K from the expected value is 3.3%.
The stability requirements for the James Webb Space Telescope (JWST) optical metering structure are driven by the science objectives of the mission. This structure, JWST Optical Telescope Element (OTE) primary mirror backplane, has to be stable over time at cryogenic temperatures. Successful development of the large, lightweight, deployable, cryogenic metering structure requires verification of structural deformations to nanometer level accuracy in representative test articles at cryogenic temperature. An instantaneous acquisition phase shifting speckle interferometer was designed and built to support the development of JWST Optical Telescope Element (OTE) primary mirror backplane. This paper discusses characterization of the Electronic Speckle Pattern Interferometer (SPS-DSPI) developed for JWST to verify its capabilities to measure structural deformations in large composite structures at cryogenic temperature. Interferometer performance during the Backplane Stability Test Article (BSTA) test that completed the TRL-6 (Technology Readiness Level-6) demonstration of Large Precision Cryogenic Structures will also be discussed.
Development of many new technologies is required to successfully produce the large, lightweight, deployable, cryogenic telescope with segmented primary mirror for the James Webb Space Telescope (JWST) mission. One of the technologies is interferometry to verify structural deformations in large, deployable, lightweight, cryogenic, precision structures to nanometer level accuracy. An instantaneous acquisition phase shifting speckle interferometer was designed and built to support the development of JWST optical telescope element (OTE) primary mirror backplane. This paper discusses characterization of the electronic speckle pattern interferometer (SPS-DSPI) developed for JWST to verify its capability to measure structural deformations in large composite structures at cryogenic temperature.
The James Webb Space Telescope Instrument Support Integration Module (ISIM) is being designed and developed at the Goddard Space Flight Center. The ISM Thermal Distortion Testing (ITDT) program was started with the primary objective to validate the ISM mechanical design process. The ITDT effort seeks to establish confidence and demonstrate the ability to predict thermal distortion in composite structures at cryogenic temperatures using solid element models. This-program's goal is to better ensure that ISIM meets all the mechanical and structural requirements by using test results to verify or improve structural modeling techniques. The first step to accomplish the ITDT objectives was to design, and then construct solid element models of a series 2-D test assemblies that represent critical building blocks of the ISIM structure. Second, the actual test assemblies consisting of composite tubes and invar end fittings were fabricated and tested for thermal distortion. This paper presents the development of the GSFC Cryo Distortion Measurement Facility (CDMF) to meet the requirements of the ISIM 2-D test. assemblies, and other future ISIM testing needs. The CDMF provides efficient cooling with both a single, and two-stage cryo-cooler. Temperature uniformity of the test assemblies during thermal transients and at steady state is accomplished by using sapphire windows for all of the optical ports on the radiation shields and by using .thermal straps to cool the test assemblies. Numerical thermal models of the test assemblies were used to predict the temperature uniformity of the parts during cooldown and at steady state. Results of these models are compared to actual temperature data from the tests. Temperature sensors with a 0.25K precision were used to insure that test assembly gradients did not exceed 2K lateral, and 4K axially. The thermal distortions of two assemblies were measured during six thermal cycles from 320K to 35K using laser interferometers. The standard deviation for all of the distortion measurements is less than 0.5 microns, which falls within the ISIM requirement of 3 microns.