The neutron electric dipole moment (EDM) is a sensitive probe for currently undiscovered sources of charge-parity symmetry violation. As part of the TRIUMF Ultracold Advanced Neutron (TUCAN) collaboration, we are developing spin analyzers for ultracold neutrons (UCNs) to be used for a next-generation experiment to measure the neutron EDM with unprecedented precision. Spin-state analysis of UCNs constitutes an essential part of the neutron EDM measurement sequence. Magnetized iron films used as spin filters of UCNs are crucial experimental components, whose performance directly influences the statistical sensitivity of the measurement. To test such iron film spin filters, we propose the use of polarized cold-neutron reflectometry, in addition to conventional UCN transmission experiments. The new method provides information on iron film samples complementary to the UCN tests and accelerates the development cycles. We developed a collaborative effort to produce iron film spin filters and test them with cold and ultracold neutrons available at JRR-3/MINE2 and J-PARC/MLF BL05. In this article, we review the methods of neutron EDM measurements, discuss the complementarity of this new approach to test UCN spin filters, provide an overview of our related activities, and present the first results of polarized cold-neutron reflectometry recently conducted at the MINE2 beamline.
Ultracold neutrons (UCNs) are a powerful tool for probing the Standard Model at high precision. The TRIUMF Ultracold Advanced Neutron (TUCAN) collaboration is building a new UCN source to provide unprecedented densities of UCNs for experiments. This source will use a tantalum-clad tungsten spallation target, receiving up to 40 µA of 480-MeV protons from TRIUMF’s main cyclotron. The beamline and target were constructed from 2014 to 2016 and operated at beam currents up to 10 µA from 2017 to 2019 as part of a prototype UCN source. We describe the design choices for the target and target-handling system, as well as our benchmarking of the target performance using UCN production measurements.
Metal tubes plated with nickel-phosphorus are used in many fundamental physics experiments using ultracold neutrons (UCN) because of their ease of fabrication. These tubes are usually polished to a average roughness of 25-150 nm. However, there is no scattering model that accurately describes UCN scattering on such a rough guide surface with a mean-square roughness larger than 5 nm. We therefore developed a scattering model for UCN in which scattering from random surface waviness with a size larger than the UCN wavelength is described by a microfacet Bidirectional Reflectance Distribution Function model (mf-BRDF model), and scattering from smaller structures by the Lambert's cosine law (Lambert model). For the surface waviness, we used the statistical distribution of surface slope measured by an atomic force microscope on a sample piece of guide tube as input of the model. This model was used to describe UCN transmission experiments conducted at the pulsed UCN source at J-PARC. In these experiments, a UCN beam collimated to a divergence angle smaller than $\pm 6^{\circ}$ was directed into a guide tube with a mean-square roughness of 6.4 nm to 17 nm at an oblique angle, and the UCN transport performance and its time-of-flight distribution were measured while changing the angle of incidence. The mf-BRDF model combined with the Lambert model with scattering probability $p_{L} = 0.039\pm0.003$ reproduced the experimental results well. We have thus established a procedure to evaluate the characteristics of UCN guide tubes with a surface roughness of approximately 10 nm.
Electroless nickel plating is an established industrial process that provides a robust and relatively low-cost coating suitable for transporting and storing ultracold neutrons (UCN). Using roughness measurements and UCN-storage experiments we characterized UCN guides made from polished aluminum or stainless-steel tubes plated by several vendors. All electroless nickel platings were similarly suited for UCN storage with an average loss probability per wall bounce of $2.8\cdot10^{-4}$ to $4.1\cdot10^{-4}$ for energies between 90 neV and 190 neV, or a ratio of imaginary to real Fermi potential $\eta$ of $1.7\cdot10^{-4}$ to $3.3\cdot10^{-4}$. Measurements at different elevations indicate that the energy dependence of UCN losses is well described by the imaginary Fermi potential. Some special considerations are required to avoid an increase in surface roughness during the plating process and hence a reduction in UCN transmission. Increased roughness had only a minor impact on storage properties. Based on these findings we chose a vendor to plate the UCN-production vessel that will contain the superfluid-helium converter for the new TRIUMF UltraCold Advanced Neutron (TUCAN) source, achieving acceptable UCN-storage properties with ${\eta=3.5(5)\cdot10^{-4}}$.
Searches for the permanent electric dipole moment of the neutron (nEDM) provide strong constraints on theories beyond the Standard Model of particle physics. The TUCAN collaboration is constructing a source for ultra-cold neutrons (UCN) and an apparatus to search for the nEDM at TRIUMF, Vancouver, Canada. In this work, we estimate that the spallation-driven UCN source based on a superfluid helium converter will provide (1.38 ± 0.02) 107 polarized UCN at a density of 217 ± 3 UCN/cm3 to a room-temperature EDM experiment per fill. With (1.43 ± 0.02) 106 neutrons detected after the Ramsey cycle, the statistical sensitivity for an nEDM search per storage cycle will be (1.94 ± 0.06) × 10−25 ecm (1σ). The goal sensitivity of 10−27 ecm (1σ) can be reached within 281 ± 16 measurement days.
The TRIUMF Ultra-Cold Advanced Neutron (TUCAN) collaboration aims at a precision neutron electric dipole moment (nEDM) measurement with an uncertainty of 10 − 27 e · cm, which is an order-of-magnitude better than the current nEDM upper limit and enables us to test Supersymmetry. To achieve this precision, we are developing a new high-intensity ultracold neutron (UCN) source using super-thermal UCN production in superfluid helium (He-II) and a nEDM spectrometer. The current development status of them is reported in this article.
A new ultracold neutron (UCN) source is being developed at TRIUMF for fundamental physics experiments. The TRIUMF UltraCold Advanced Neutron (TUCAN) Collaboration seeks to measure the neutron elect...
MT26, THE 26th International Conference on Magnet Technology, took place in the beautiful city of Vancouver in Canada, at the Hyatt Regency Hotel, from September 22 to 27, 2019. The conference was supported by the IEEE Council on Superconductivity and hosted by TRIUMF. The scope of MT26 included magnet technology ranging from large scale magnets for high field facilities, particle accelerators, pl...
The Ultracold Neutron Asymmetry (UCNA) experiment was designed to measure the $\beta$-decay asymmetry parameter, $A_0$, for free neutron decay. In the experiment, polarized ultracold neutrons are transported into a decay trap, and their $\beta$-decay electrons are detected with $\approx 4\pi$ acceptance into two detector packages which provide position and energy reconstruction. The experiment also has sensitivity to $b_{n}$, the Fierz interference term in the neutron $\beta$-decay rate. In this work, we determine $b_{n}$ from the energy dependence of $A_0$ using the data taken during the UCNA 2011-2013 run. In addition, we present the same type of analysis using the earlier 2010 $A$ dataset. Motivated by improved statistics and comparable systematic errors compared to the 2010 data-taking run, we present a new $b_{n}$ measurement using the weighted average of our asymmetry dataset fits, to obtain $b_{n} = 0.066 \pm 0.041_{\text{stat}} \pm 0.024_{\text{syst}}$ which corresponds to a limit of $-0.012 < b_{n} < 0.144$ at the 90% confidence level.
We report on our efforts to optimize the geometry of neutron moderators and converters for the TRIUMF UltraCold Advanced Neutron (TUCAN) source using MCNP simulations. It will use an existing spallation neutron source driven by a 19.3 kW proton beam delivered by TRIUMF's 520 MeV cyclotron. Spallation neutrons will be moderated in heavy water at room temperature and in liquid deuterium at 20 K, and then superthermally converted to ultracold neutrons in superfluid, isotopically purified He-4. The helium will be cooled by a He-3 fridge through a He-3-He-4 heat exchanger. The optimization took into account a range of engineering and safety requirements and guided the detailed design of the source. The predicted ultracold-neutron density delivered to a typical experiment is maximized for a production volume of 27 L, achieving a production rate of 1.4 . 10(7) s(-1) to 1.6 . 10(7) s(-1) with a heat load of 8.1W. At that heat load, the fridge can cool the superfluid helium to 1.1 K, resulting in a storage lifetime for ultracold neutrons in the source of about 30 s. The most critical performance parameters are the choice of cold moderator and the volume, thickness, and material of the vessel containing the superfluid helium. The source is scheduled to be installed in 2021 and will enable the TUCAN collaboration to measure the electric dipole moment of the neutron with a sensitivity of 10(-27) e cm.
Neutron beta decay is one of the most fundamental processes in nuclear physics and provides sensitive means to uncover the details of the weak interaction. Neutron beta decay can evaluate the ratio of axial-vector to vector coupling constants in the standard model, λ = gA/gV, through multiple decay correlations. The Nab experiment will carry out measurements of the electron-neutrino correlation parameter a with a precision of δa/a = 10−3 and the Fierz interference term b to δb = 3 × 10−3 in unpolarized free neutron beta decay. These results, along with a more precise measurement of the neutron lifetime, aim to deliver an independent determination of the ratio λ with a precision of δλ/λ = 0.03% that will allow an evaluation of Vud and sensitively test CKM unitarity, independent of nuclear models. Nab utilizes a novel, long asymmetric spectrometer that guides the decay electron and proton to two large area silicon detectors in order to precisely determine the electron energy and an estimation of the proton momentum from the proton time of flight. The Nab spectrometer is being commissioned at the Fundamental Neutron Physics Beamline at the Spallation Neutron Source at Oak Ridge National Lab. We present an overview of the Nab experiment and recent updates on the spectrometer, analysis, and systematic effects.
A fast-switching, high-repetition-rate magnet and power supply have been developed for and operated at TRIUMF, to deliver a proton beam to the new ultracold neutron (UCN) facility. The facility possesses unique operational requirements: a time-averaged beam current of 40 μA with the ability to switch the beam on or off for several minutes. These requirements are in conflict with the typical operation mode of the TRIUMF cyclotron which delivers nearly continuous beam to multiple users. To enable the creation of the UCN facility, a beam-sharing arrangement with another facility was made. The beam sharing is accomplished by the fast-switching (kicker) magnet which is ramped in 50 μs to a current of 193 A, held there for approximately 1 ms, then ramped down in the same short period of time. This achieves a 12 mrad deflection which is sufficient to switch the proton beam between the two facilities. The kicker magnet relies on a high-current, low-inductance coil connected to a fast-switching power supply that is based on insulated-gate bipolar transistors (IGBTs). The design and performance of the kicker magnet system and initial beam delivery results are reported.
In January, 2018, Fornal and Grinstein proposed that a previously unobserved neutron decay branch to a dark matter particle (χ) could account for the discrepancy in the neutron lifetime observed in two different types of experiments. One of the possible final states discussed includes a single χ along with an e + e − pair. We use data from the UCNA (Ultracold Neutron Asymmetry) experiment to set limits on this decay channel. Coincident electron-like events are detected with ∼ 4π acceptance using a pair of detectors that observe a volume of stored Ultracold Neutrons (UCNs). We use the timing information of coincidence events to select candidate dark sector particle decays by applying a timing calibration and selecting events within a physically-forbidden timing region for conventional n → p + e - + ν̅ e decays. The summed kinetic energy ( E e + e − ) from such events is reconstructed and used to set limits, as a function of the χ mass, on the branching fraction for this decay channel.
This article describes the new primary proton beamline 1U at TRIUMF. The purpose of this beamline is to produce ultracold neutrons (UCN) for fundamental-physics experiments. It delivers up to 40 microA of 480 MeV protons from the TRIUMF cyclotron to a tungsten spallation target and uses a fast kicker to share the beam between the Center for Molecular and Materials Science and UCN. The beamline has been successfully commissioned and operated with a beam current up to 10 microA, facilitating first large-scale UCN production in Canada.
We installed a source for ultracold neutrons at a new, dedicated spallation target at TRIUMF. The source was originally developed in Japan and uses a superfluid-helium converter cooled to 0.9 K. During an extensive test campaign in November 2017, we extracted up to 325 000 ultracold neutrons after a one-minute irradiation of the target, over three times more than previously achieved with this source. The corresponding ultracold-neutron density in the whole production and guide volume is 5.3 cm(-3). The storage lifetime of ultracold neutrons in the source was initially 37 s and dropped to 24 s during the 18 days of operation. During continuous irradiation of the spallation target, we were able to detect a sustained ultracold-neutron rate of up to 1500 s(-1). Simulations of UCN production, UCN transport, temperature-dependent UCN yield, and temperature-dependent storage lifetime show excellent agreement with the experimental data and confirm that the ultracold-neutron-upscattering rate in superfluid helium is proportional to T-7.
The UCNA experiment was designed to measure the neutron β-asymmetry parameter A_0 using polarized ultracold neutrons (UCN). UCN produced via downscattering in solid deuterium were polarized via transport through a 7 T magnetic field, and then directed to a 1 T solenoidal electron spectrometer, where the decay electrons were detected in electron detector packages located on the two ends of the spectrometer. A value for A_0 was then extracted from the asymmetry in the numbers of counts in the two detector packages. We summarize all of the results from the UCNA experiment, obtained during run periods in 2007, 2008–2009, 2010, and 2011–2013, which ultimately culminated in a 0.67% precision result for A_0.
Ultracold neutrons (UCN) with kinetic energies up to 300 neV can be stored in material or magnetic confinements for hundreds of seconds.This makes them a very useful tool for probing fundamental symmetries of nature, by searching for charge-parity violation by a neutron electric dipole moment, and yielding important parameters for Big Bang nucleosynthesis, e.g. in neutron-lifetime measurements.Further increasing the intensity of UCN sources is crucial for next-generation experiments.Advanced Monte Carlo (MC) simulation codes are important in optimization of neutron optics of UCN sources and of experiments, but also in estimation of systematic effects, and in bench-marking of analysis codes.Here we will give a short overview of recent MC simulation activities in this field.
It has been proposed recently that a previously unobserved neutron decay branch to a dark matter particle (X) could account for the discrepancy in the neutron lifetime observed in experiments that use two different measurement techniques. One of the possible final states discussed includes a single X along with an e(+)e(-) pair. We use data from the UCNA (Ultracold Neutron Asymmetry) experiment to set limits on this decay channel. Coincident electron-like events are detected with similar to 4 pi acceptance using a pair of detectors that observe a volume of stored ultracold neutrons. The summed kinetic energy (E-e+(e)-) from such events is used to set limits, as a function of the X mass, on the branching fraction for this decay channel. For X masses consistent with resolving the neutron lifetime discrepancy, we exclude this as the dominant dark matter decay channel at >> 5 sigma level for 100 < E-e+(e)- < 644 keV. If the X + e(+)e(-) final state is not the only one, we set limits on its branching fraction of <10(-4) for the above E-e+(e)- range at >90% confidence level.
Background: The neutron beta-decay asymmetry parameter A(0) defines the angular correlation between the spin of the neutron and the momentum of the emitted electron. Values for A(0) permit an extraction of the ratio of the weak axial-vector to vector coupling constants, lambda g(A)/g(V), which under assumption of the conserved vector current hypothesis (g(V) = 1) determines g(A). Precise values for g(A) are important as a benchmark for lattice QCD calculations and as a test of the standard model. Purpose: The UCNA experiment, carried out at the Ultracold Neutron (UCN) source at the Los Alamos Neutron Science Center, was the first measurement of any neutron beta-decay angular correlation performed with UCN. This article reports the most precise result for A(0) obtained to date from the UCNA experiment, as a result of higher statistics and reduced key systematic uncertainties, including from the neutron polarization and the characterization of the electron detector response. Methods: UCN produced via the down scattering of moderated spallation neutrons in a solid deuterium crystal were polarized via transport through a 7 T polarizing magnet and a spin flipper, which permitted selection of either spin state. The UCN were then contained within a 3-m long cylindrical decay volume, situated along the central axis of a superconducting 1 T solenoidal spectrometer. With the neutron spins then oriented parallel or anti-parallel to the solenoidal field, an asymmetry in the numbers of emitted decay electrons detected in two electron detector packages located on both ends of the spectrometer permitted an extraction of A(0). Results: The UCNA experiment reports a new 0.67% precision result for A(0) of A(0) = -0.12054(44)(stat)(68)(syst), which yields lambda = g(A)/g(V) = -1.2783(22). Combination with the previous UCNA result and accounting for correlated systematic uncertainties produces A(0) = - 0.12015(34)(stat)(63)(syst) and lambda = g(A)/g(V) = -1.2772(20). Conclusions: This new result for A(0) and g(A)/g(V) from the UCNA experiment has provided confirmation of the shift in values for g(A)/g(V) that has emerged in the published results from more recent experiments, which are in striking disagreement with the results from older experiments. Individual systematic corrections to the asymmetries in older experiments (published prior to 2002) were >10%, whereas those in the more recent ones (published after 2002) have been of the scale of <2%. The impact of these older results on the global average will be minimized should future measurements of A(0) reach the 0.1% level of precision with central values near the most recent results.