Deimos was the first critical experiment using high-assay low-enriched uranium (HALEU) TRistructural ISOtropic (TRISO) fuel in over 40 years. HALEU TRISO is the desired fuel form for many of the advanced reactor designs in development; however, very little experimental data are available for this fuel type. Deimos was designed to utilize existing HALEU TRISO fuel in a large graphite moderator to obtain nuclear and reactor physics data to fill the gaps surrounding this fuel type and enrichment. In addition to cold critical data, three separate heated experiments were conducted to measure the temperature reactivity coefficient for this type of system. These measured coefficients were then compared to simulated coefficients to a first level order of fidelity. This comparison showed very good agreement for the experiment where only the inner core was heated and good agreement for the other two configurations, which included heating portions of the outer core. Less agreement when the outer core was heated is attributed to potential heating in the beryllium reflector, which has a positive temperature reactivity coefficient and was unaccounted for in the first-order models. Future heated experiments with Deimos will include temperature monitoring of the beryllium reflector to account for beryllium heating in the simulations.
High-assay low-enriched uranium (HALEU) fuel is a key component of many small modular reactor designs. Critical experiments are an important way to understand the neutronic performance of systems by obtaining nuclear data validations through measurements. Data reduce uncertainty and risk by showing that systems respond as predicted to changes such as temperature, subsequently advancing the overall technology readiness level of the materials within. Numerous critical experiments have been performed at the National Criticality Experiments Research Center (NCERC) operated by Los Alamos National Laboratory at the Nevada National Security Site since it became operational in 2011. However, the first experiment with HALEU fuel did not occur until 2024. Through extensive engineering, the experiment described in this paper was successfully designed and executed for the Comet vertical lift assembly at NCERC to perform measurements with HALEU tri-structural isotropic fuel that will assist in validation of nuclear data and computational modeling of small modular reactors for years to come.
The Measurement of Uranium Subcritical and Critical (MUSIC) experiment was a series of measurements of critical and subcritical configurations of bare highly enriched uranium. The goal was to compare measurement methods, analysis techniques, and simulation methods across regimes of criticality and to provide high-quality validation of 235U nuclear data. A benchmark evaluation of the two critical configurations of the MUSIC experiments will soon be published in the release of the International Criticality Safety Benchmark Evaluation Project Handbook. The recent execution of the experiment aids in proper quantification of model simplifications and all uncertainties associated with the experiment. Historical benchmark evaluations are heavily relied on for uranium nuclear data validation despite the fact that the same level of documentation and comparable uncertainty analysis may not be present. The MUSIC evaluation is less likely to include "unknown unknowns" that could impede accurately modeling the system. Presented are both highly detailed and very simplified models, which represent the experimental configurations accurately, aiding the users of the benchmark for nuclear data or transport code validation. The sensitivities of $${k_{eff}}$$keff to nuclear data and nuclear data-related uncertainties are very similar between this experiment and previous bare uranium sphere experiments. In addition, the nuclear data uncertainties to any nuclides other than $$<^>{235}$$ 235U are small. For all these reasons, the recently evaluated MUSIC benchmark critical configurations could prove very useful for $$<^>{235}$$ 235U nuclear data validation. Currently, major libraries have good agreement with the experimental results, within 200 pcm for all nuclear data libraries, and within one standard deviation of the experimental result for most. Suggested nuclear data adjustments based on MUSIC and Lady Godiva are also presented, with posterior improvements to both the agreement in $${k_{eff}}$$keff and the uncertainty associated with the nuclear data.
Godiva IV is a cylindrical fast burst reactor comprised of approximately 65 kg of highly enriched uranium that is operated by Los Alamos National Laboratory and sited at the National Criticality Experiments Research Center at the Nevada National Security Site in Nevada in the United States. Godiva IV is typically operated at delayed critical and in the regime spanning from sub-prompt to super-prompt bursts. Godiva IV is used for sample irradiations, criticality safety demonstrations, dosimetry studies, and for studying super-prompt behavior. In preparation for both an upcoming experiment to reduce uncertainties in the prompt fission spectrum for 235U using threshold neutron detectors, and for future research using Godiva IV, it was desired to exercise the process of the selection of threshold neutron detectors/activation foils, radiation metrology, and the subsequent adjustment of the neutron spectrum. For this exercise, nine high purity threshold neutron detectors/activation foils were irradiated in a Godiva IV burst. The foils were then analyzed using a high-purity germanium detector in the NCERC counting laboratory to determine end of irradiation specific activities for available IRDFF-II reactions. This work summarizes the Godiva IV foil irradiation, radiation metrology results, and adjusted neutron spectrum. The results of this exercise ultimately characterized the neutron environment inside the sample irradiation cavity inside Godiva IV to a higher degree than previously performed, informed decisions for the upcoming larger scale experiment, and will inform future neutron spectrum characterizations at NCERC.
free air). Similar exercises have been held in 2016 and 2018 using National Criticality Experiments Research Center’s (NCERC’s) Flattop and Godiva assemblies.
The National Criticality Experiments Research Center (NCERC) located at the Nevada National Security Site (NNSS) in the Device Assembly Facility (DAF) and operated by Los Alamos National Laboratory (LANL) is the only general purpose critical experiments facility in the United States. Experiments from subcritical to critical and above prompt critical are carried out at NCERC on a regular basis. In recent years, NCERC has become more involved in experiments related to nuclear energy, including the Kilopower/KRUSTY demonstration and the recent Hypatia experiment. Multiple nuclear energy related projects are currently ongoing at NCERC. This paper discusses NCERC’s role in advanced reactor design and how that role may change in the future.