As part of a collaborative international effort organized by the Lawrence Livermore National Laboratory (LLNL), with key participants from the Institut de radioprotection et de s & ucirc;ret & eacute; nucl & eacute;aire (IRSN), Los Alamos National Laboratory (LANL), and the Sandia National Laboratories (SNL), a series of high-multiplication subcritical neutron and gamma noise measurements was planned and executed. The primary aim of this article was to advance detector technology, assess the validity of gamma noise for subcriticality measurements, and nuclear criticality safety, focusing on collecting list-mode or time-series data from various reactor configurations with multiplication values ranging from 20 to 310. This comprehensive dataset enabled a detailed comparative analysis of multiple detector systems and the results of both neutron and gamma noise measurements. In this work, we focus on experimentally comparing the results from neutron and gamma noise measurements. We note good agreement between estimations of the prompt neutron decay constant and demonstrate the effects of changing reactor geometry on the efficiency of the differing methods. Our results agree well with independent experimental measurements and simulations performed by LLNL.
As part of a collaborative international effort organized by Lawrence Livermore National Laboratory (LLNL), with key participants from L’Institut de radioprotection et de sûreté nucléaire (IRSN), Los Alamos National Laboratory (LANL), and Sandia National Laboratories (SNL), a series of high-multiplication subcritical neutron and gamma noise measurements were planned and executed. The primary aim of this research was to advance detector technology, assess the validity of gamma noise for subcriticality measurements, and nuclear criticality safety, focusing on collecting list-mode or time-series data from various reactor configurations with multiplication values ranging from 20 to 310. This comprehensive dataset enabled a detailed comparative analysis of multiple detector systems and the results of both neutron and gamma noise measurements. In this work we focus on experimentally comparing the results from neutron and gamma noise measurements. We note good agreement between estimations of the prompt neutron decay constant and demonstrate the effects of changing reactor geometry on the efficiency of the differing methods.
In addition to nuclear data validation and criticality safety research, criticality experiments offer unique opportunities for investigations into fundamental reactor physics phenomena and measurement techniques. Unlike conventional light water research reactors where kinetics parameters do not significantly deviate from one reactor to another, critical experiments with neutron lifetimes from tens of nanoseconds to tens of microseconds can be constructed on vertical lift machines. Kinetics measurements of new fast reactors will be crucial for the validation of computational methods. In this work, we present the results of neutron noise measurements of a fast highly enriched uranium-fueled copper-reflected critical system constructed on the Comet vertical lift assembly at the National Criticality Experiments Research Center. Fluctuations in the system's neutron population were analyzed in the frequency domain by 3He proportional counters and organic scintillators in order to measure the prompt neutron decay constant alpha at delayed critical and four subcritical states. Agreement between the extrapolated alpha DC values of the two detector systems was within 4%. Additionally, alpha values at delayed critical were examined as a function of time in the presence of small power drifts. By comparing to the linear channel, it is shown that these drifts did not cause a noticeable effect on alpha but did inversely vary with the signal amplitude. A consistent bias between the 3He and scintillator measurements of alpha and signal amplitude was observed and is believed to be caused by electronic noise or spacial effects. These measurement techniques will be essential in supporting the development and deployment of advanced fast reactor types through their ability to verify and validate computational methods.
Special nuclear material in sub-critical and critical configurations measured in integral experiments are important for validation and adjustment of nuclear data. Many different evaluations of nuclear data exist, and these different evaluations can provide different values for individual cross sections that vary due to the uncertainties in differential experiments or lack of such data. For integral experiments, differences in these individual cross sections can have compensating errors, which lead to the same answer. One example of this is the Jezebel critical assembly, where k(eff) of the system is correctly computed by both ENDF/B-VIII.0 and JEFF-3.3, despite having substantially different underlying evaluated values for specific reactions (such as elastic and inelastic cross sections). To reduce compensating errors in nuclear data, the Experiments Underpinned by Computational Learning for Improvements in Nuclear Data (EUCLID) project has utilized machine learning to design a set of sub-critical and critical experiments. These experiments include slab- and cube-like configurations of 239 Pu in the form of the ZPPR plates. Six different responses were measured on a total of thirteen different configurations. One of these responses, the neutron leakage spectrum, was measured using an EJ301D detector. The results of the neutron leakage spectra show good agreement (within 1-2 sigma) with the expected spectrum from simulations and will be used in the subsequent nuclear data adjustment done by the EUCLID team.
Reaction rate ratios are integral responses that are used within the criticality experiments field because they contain spectral information. While these types of measurements have been utilized for nuclear data validation with historic experiments, few experiments of this type have been utilized for recent experiments, as few exist. This work focuses on measured reaction rate ratios for two nearly bare plutonium critical assemblies with different geometries: one that is cube like (with a Pu mass of 40 kg) and one that is slab like (with a Pu mass of 109 kg). Irradiations were performed with both configurations in which foils were placed near the center of the assembly. Plutonium, highly enriched uranium, depleted uranium, and Au foils were included in the irradiation and counted via high-purity germanium detectors. From these measurements, reaction rate ratios were calculated.Measured and simulated values and uncertainties are presented for the reaction rate ratios. Ratios utilizing the following reactions are given in this work: 197Au(n, $$\gamma $$gamma), 197Au(n,2n), 235U(n,fission), 238U(n,fission), 238U(n,2n), 238U(n,$$\gamma $$gamma), and 239Pu(n,fission). Uncertainties for the measured reaction rate ratios ranged from 4% to 7%, and the contribution of various parameters to this uncertainty was investigated. The results are compared to historical experiments and should be used for nuclear data validation for future nuclear data library releases. These measurements are part of the EUCLID (Experiments Underpinned by Computational Learning for Improvements in Nuclear Data) project, which utilizes measurement responses in addition to keff (such as these reaction rate ratios) to help reduce uncertainties in 239Pu nuclear data.
Integral Experiment Request (IER) 538 is part of a series of dose characterization and nuclear accident dosimetry (NAD) exercises performed under the Department of Energy (DOE) Nuclear Criticality Safety Program (NCSP). This is the second NAD exercise using the Godiva-IV critical assembly and the third NAD exercise overall. The participating laboratories provided their own dosimeters that were mounted on the Lawrence Livermore National Laboratory (LLNL) BOttle Manikin ABsorption (BOMAB) phantoms and aluminum plates. The BOMABs and plates were placed at two, three, and four meters away from the center of Godiva. Alongside the NADs, there was a LLNL Passive Neutron Spectrometer (PNS), Atomic Weapons Establishment (AWE) PNS, and Y-12 Sphere present to measure the neutron dose from Godiva-IV. Two irradiations were conducted to test the NAD performance from each laboratory and assesses their performance to the DOE-STD-1098-2017 part 515 criteria. Neutron and gamma doses were measured prior to this exercise. This work presents a model for the neutron and gamma dose respectively to serve as the reference value. A code written in C/C++/ROOT was used to fit the measured neutron and gamma dose with the new models. It was assumed that the neutron and gamma doses are proportional to the change in temperature of Godiva after a burst irradiation. Uncertainties for the reference values were calculated using error propagation of the model’s parameters. Preliminary results (within twenty-four hours) and final results were compared for each laboratory. On average of all the participating laboratories, 32% of neutron doses and 78% of gamma doses were outside the DOE standards. One laboratory did not report their dose readings and were not included in this average. There is a bias for a lower neutron dose and a higher gamma dose based on the distribution of results. In comparison with the past Godiva-IV NAD exercise, there is an improvement in neutron dose readings by 20%.
Godiva IV is a cylindrical fast burst reactor comprised of approximately 65 kg of highly enriched uranium that is operated by Los Alamos National Laboratory and sited at the National Criticality Experiments Research Center at the Nevada National Security Site in Nevada in the United States. Godiva IV is typically operated at delayed critical and in the regime spanning from sub-prompt to super-prompt bursts. Godiva IV is used for sample irradiations, criticality safety demonstrations, dosimetry studies, and for studying super-prompt behavior. In preparation for both an upcoming experiment to reduce uncertainties in the prompt fission spectrum for 235U using threshold neutron detectors, and for future research using Godiva IV, it was desired to exercise the process of the selection of threshold neutron detectors/activation foils, radiation metrology, and the subsequent adjustment of the neutron spectrum. For this exercise, nine high purity threshold neutron detectors/activation foils were irradiated in a Godiva IV burst. The foils were then analyzed using a high-purity germanium detector in the NCERC counting laboratory to determine end of irradiation specific activities for available IRDFF-II reactions. This work summarizes the Godiva IV foil irradiation, radiation metrology results, and adjusted neutron spectrum. The results of this exercise ultimately characterized the neutron environment inside the sample irradiation cavity inside Godiva IV to a higher degree than previously performed, informed decisions for the upcoming larger scale experiment, and will inform future neutron spectrum characterizations at NCERC.
operations with fissionable materials. The benchmarks in the handbook are categorized by their fissile material composition, material form (oxide, solution, or metal), and fission energy spectra. This is especially useful for those looking for benchmarks similar to a system they are working on to compare methods and identify trends. The ICSBEP Handbook Uncertainty Guide is document outlining recommended practices and methods for determining uncertainties in these benchmarks. Quantifying these uncertainties thoroughly is crucial as it allows a higher degree of confidence that data used from them is valid and relevant. The guide stresses the importance of a thorough and well documented uncertainty analysis when evaluating an experiment. All measured values of a system, whether they be dimensions or material compositions, have a certain amount of uncertainty associated with them and can be analyzed one by one to determine their effects on the system. Many evaluated benchmarks in the handbook present this in detail, however some do not, mostly earlier evaluations performed in the 1990's and early 2000's. Recently at Los Alamos National Laboratory (LANL), the Nuclear Criticality Safety Division (NCSD) of LANL has been validating MCNP6.2® input files of criticality benchmarks for use by Whisper, a criticality safety code developed at LANL. This effort is also part of the OECD NEA Working Party on International Nuclear Data Evaluation Co-operation (WPEC) Subgroup 45, also known as Validation of Nuclear Data Libraries (VaNDaL). The goal of VaNDaL is to compile a set of validated simulation inputs for use in validating nuclear data and simulation codes. As part of these efforts, one of the benchmarks reviewed was the MIX SOL-THERM-003 ICSBEP benchmark. This paper provides an independent uncertainty analysis of this benchmark experiment.