Measurement of O+ in the Earth's magnetosphere is important for monitoring and understanding the initiation and evolution of geomagnetic activity. During active times, O+ can be the most abundant ion in the magnetosphere. Furthermore, because O+ and H+ damage exposed spacecraft materials through different processes, measurement and prediction of O+ and H+ fluxes is critical for understanding cumulative damage effects to these materials resulting from the ambient plasma environment of a spacecraft. We describe a simple technique for quantitative, in situ measurement of O+ and H+ fluxes using ultrathin foils. This technique is a low‐resource addition to a standard electrostatic energy‐per‐charge analyzer followed by an array of detectors. H+ and O+ abundances up to a few tens of keV can be determined by comparison of counts in detectors having no ultrathin foil at the detector aperture, in which both H+ and O+ are detected, and adjacent detectors having a foil over the aperture of the appropriate thickness to stop the transmission of O+ but through which H+ can transit. We describe three techniques for implementing this method enabling differentiation of O+ and H+ in an instrument package significantly simpler than traditional mass spectrometers.
We present a fundamentally new type of space plasma spectrometer, the wide field of view plasma spectrometer, whose field of view is >1.25 ster using fewer resources than traditional methods. The enabling component is analogous to a pinhole camera with an electrostatic energy-angle filter at the image plane. Particle energy-per-charge is selected with a tunable bias voltage applied to the filter plate relative to the pinhole aperture plate. For a given bias voltage, charged particles from different directions are focused by different angles to different locations. Particles with appropriate locations and angles can transit the filter plate and are measured using a microchannel plate detector with a position-sensitive anode. Full energy and angle coverage are obtained using a single high-voltage power supply, resulting in considerable resource savings and allowing measurements at fast timescales. We present laboratory prototype measurements and simulations demonstrating the instrument concept and discuss optimizations of the instrument design for application to space measurements.
Channel electron multiplier (CEM) and microchannel plate (MCP) detectors are routinely used in space instrumentation for measurement of space plasmas. Our goal is to understand the relative sensitivities of these detectors to penetrating radiation in space, which can generate background counts and shorten detector lifetime. We use 662 keV γ-rays as a proxy for penetrating radiation such as γ-rays, cosmic rays, and high-energy electrons and protons that are ubiquitous in the space environment. We find that MCP detectors are ~ 20 times more sensitive to 662 keV γ-rays than CEM detectors. This is attributed to the larger total area of multiplication channels in an MCP detector that is sensitive to electronic excitation and ionization resulting from the interaction of penetrating radiation with the detector material. In contrast to the CEM detector, whose quantum efficiency εγ for 662 keV γ-rays is found to be 0.00175 and largely independent of detector bias, the quantum efficiency of the MCP detector is strongly dependent on the detector bias, with a power law index of 5.5. Background counts in MCP detectors from penetrating radiation can be reduced using MCP geometries with higher pitch and smaller channel diameter.
The HOPE mass spectrometer of the Radiation Belt Storm Probes (RBSP) mission (renamed the Van Allen Probes) is designed to measure the in situ plasma ion and electron fluxes over 4π sr at each RBSP spacecraft within the terrestrial radiation belts. The scientific goal is to understand the underlying physical processes that govern the radiation belt structure and dynamics. Spectral measurements for both ions and electrons are acquired over 1 eV to 50 keV in 36 log-spaced steps at an energy resolution ΔE FWHM/E≈15 %. The dominant ion species (H+, He+, and O+) of the magnetosphere are identified using foil-based time-of-flight (TOF) mass spectrometry with channel electron multiplier (CEM) detectors. Angular measurements are derived using five polar pixels coplanar with the spacecraft spin axis, and up to 16 azimuthal bins are acquired for each polar pixel over time as the spacecraft spins. Ion and electron measurements are acquired on alternate spacecraft spins. HOPE incorporates several new methods to minimize and monitor the background induced by penetrating particles in the harsh environment of the radiation belts. The absolute efficiencies of detection are continuously monitored, enabling precise, quantitative measurements of electron and ion fluxes and ion species abundances throughout the mission. We describe the engineering approaches for plasma measurements in the radiation belts and present summaries of HOPE measurement strategy and performance.
The IBEX-Hi Neutral Atom Imager of the Interstellar Boundary Explorer (IBEX) mission is designed to measure energetic neutral atoms (ENAs) originating from the interaction region between the heliosphere and the local interstellar medium (LISM). These ENAs are plasma ions that have been heated in the interaction region and neutralized by charge exchange with the cold neutral atoms of the LISM that freely flow through the interaction region. IBEX-Hi is a single pixel ENA imager that covers the ENA spectral range from 0.38 to 6 keV and shares significant energy overlap and overall design philosophy with the IBEX-Lo sensor. Because of the anticipated low flux of these ENAs at 1 AU, the sensor has a large geometric factor and incorporates numerous techniques to minimize noise and backgrounds. The IBEX-Hi sensor has a field-of-view (FOV) of 6.5°×6.5° FWHM, and a 6.5°×360° swath of the sky is imaged over each spacecraft spin. IBEX-Hi utilizes an ultrathin carbon foil to ionize ENAs in order to measure their energy by subsequent electrostatic analysis. A multiple coincidence detection scheme using channel electron multiplier (CEM) detectors enables reliable detection of ENAs in the presence of substantial noise. During normal operation, the sensor steps through six energy steps every 12 spacecraft spins. Over a single IBEX orbit of about 8 days, a single 6.5°×360° swath of the sky is viewed, and re-pointing of the spin axis toward the Sun near perigee of each IBEX orbit moves the ecliptic longitude by about 8° every orbit such that a full sky map is acquired every six months. These global maps, covering the spectral range of IBEX-Hi and coupled to the IBEX-Lo maps at lower and overlapping energies, will answer fundamental questions about the structure and dynamics of the interaction region between the heliosphere and the LISM.
Thin foils are used extensively in space plasma spectrometers, for example, for generation of a coincidence measurement via secondary electron emission in time-of-flight mass spectrometers and charge conversion of energetic neutral atoms (ENAs) in ENA imagers. An ion or neutral atom passing through the carbon foil experiences energy loss and straggling that can degrade the energy resolution or mass resolution. These effects need to be quantified in order to permit efficient instrument development and modeling. We present measurements of energy loss and energy loss straggling for H, He, C, N, O, Ne, and Ar ions between 1 and 50keV passing through carbon foils of different thicknesses (nominally between 0.5 and 3.0μg∕cm2). We derive empirical relationships for the energy loss and energy loss straggling as a function of foil thickness, ion species, and ion energy. In particular, below ∼10keV the energy loss of hydrogen seems to vary with foil thickness and the energy loss straggling seems to vary with the square root of the thickness. Our results apply equally well to ions and neutral atoms.
The Medium Energy Neutral Atom (MENA) instrument flown on the NASA IMAGE spacecraft is a time-of-flight neutral particle imager designed to image energetic neutral atom emissions from the Earth’s inner magnetosphere over an energy per mass range of 1–60keV∕amu. Images are generated by combining data from three separate heads and have a nominal angular resolution of 4°×4°. Here, we present a first-principles calculation of the geometric factors for each of the start-byte/stop-byte combinations for each of the three heads in the IMAGE/MENA instrument based on a detailed understanding of the its physical construction. The geometric factors are used to compute combined integral flux images and it is demonstrated that they result in head-to-head matching of the data that are both continuous and physically reasonable. We also discuss several issues associated with energy binning as a means for constructing differential flux images and present a powerful and robust approach that solves several critical problems inherent with this type of instrument.
Space-based ion mass spectrometers and neutral atom imagers often utilize a thin foil for generation of secondary electrons and employ a coincidence measurement between detection of the secondary electrons and detection of the primary ion or neutral atom, allowing unambiguous detection of the particle in a large noise background and determination of properties of the particle using time-of-flight measurement. We demonstrate a simple and straightforward method for laboratory calibration and in situ quantification and monitoring of the absolute detection probabilities of the detectors and the absolute detection efficiency of the detector subsystem without knowledge of the incident particle flux.
Recent advances in solid-state detector (SSD) technology have demonstrated the detection of ions and electrons down to 1 keV. However, ions at keV energies lose a substantial amount of energy ΔN in a SSD through Coulombic interactions with target nuclei rather than through interactions that contribute to the SSD output pulse, whose magnitude is a measure of the ion’s incident energy. Because ΔN depends on the ion species, detector material, and interaction physics, it represents a fundamental limitation of the output pulse magnitude of the detector. Using 100% quantum collection efficiency silicon photodiodes with a thin (40–60 Å) SiO2 passivation layer, we accurately quantify ΔN for incident 1–120 keV ions and, therefore, evaluate the detection limits of keV ions using silicon detectors.
Using silicon photodiodes with an ultrathin passivation layer, the average total energy lost to silicon target electrons (electronic stopping) by incident low energy ions and the recoil target atoms they generate is directly measured. We find that the total electronic energy deposition and the ratio of the total nuclear to electronic stopping powers for the incident ions and their recoils each follow a simple, universal representation, thus enabling systematic prediction of ion-induced effects in silicon. We also observe a velocity threshold at 0.05 a.u. for the onset of electronic stopping.