A new strategy of three-electrode system fabrication in polymer-based microfluidic systems is described here. Standard lithography, hot embossing and UV-assisted thermal bonding were employed for fabrication and assembly of the microfluidic chip. For the electrode design the gold working (WE) and counter electrodes (CE) are placed inside a main channel through which the sample solution passes. A silver reference electrode (RE) is embedded in a small side channel containing KCl solution that is continuously pushed into the main channel. In the present work, the overall electrochemical set up and its microfabrication is described. Conditions including silver ion concentration, cyclic voltammetry (CV) settings, and the flow rate of KCl solution in the RE channel were optimized. The electrochemical performance of the three-electrode system was evaluated by CV and also by amperometric oxidation of ferro hexacyanide ([Fe(CN)6]4-) and ruthenium bipyridyl ([Ru(bipy)3]2+) at 400 mV and 1200 mV, respectively. CV analysis using ferri/ferro hexacyanide showed a stable, quasi-reversible redox reaction at the electrodes with 96 mV peak separation and an anodic/cathodic peak ratio of 1. Amperometric analysis of the electrochemical species resulted in linear correlation between analyte concentration and current response in the range of 0.515 mu M for [Fe(CN)6]4-, and 01000 mu M for [Ru(bipy)3]2+. Upon the given experimental conditions, the limit of detection was found to be 3.15 mu M and 24.83 mu M for [Fe(CN)6]4- and [Ru(bipy)3]2+, respectively. As a fully integrated three-electrode system that is fabricated on polymer substrates, it has great applications in microfluidic-based systems requiring stable electrochemical detection.
As we near the 50th anniversary of the development of modern ion-selective electrodes (ISEs), the Matrafured Conference seemed to be the ideal venue to reminisce about the early years, since Hungary is generally regarded as the birthplace of these new electrodes. Those of us, who worked with ISEs in the 1960s and '70s, can recall the excitement of discovery existing at the time. In this reminiscence, I shall first provide a few vignettes of the leaders in the early years followed by a description of some of my personal research to demonstrate the variety of novel approaches open to investigators of that era.
The use of nucleic acid sequence-based amplification (NASBA), a continuous and isothermal method of in vitro nucleic acid amplification, was investigated for the specific identification of Escherichia coli (E. coli). A set of primers was selected from a highly conserved region of the 16S rRNA sequence of E. coli sandwiching a variable sequence to perform the amplification of bacterial RNA using NASBA. A probe was identified and shown to hybridize specifically to the amplified single-stranded RNA products of all tested E. coli isolates, including enterohemorrhagic serotype O157:H7. The high sensitivity of this assay system is most likely due to the large amplification power of NASBA and the high copy number of 16S rRNA.
20.
A bioanalytical detection method for specific detection of viable human pathogenic Cryptosporidium species, C. parvum, C. hominis, and C. meleagridis is described. Oocysts were isolated from water samples via immunomagnetic separation, and mRNA was extracted with oligo-dT magnetic beads, amplified using nucleic acid sequence-based amplification (NASBA), and then detected in a nucleic acid hybridization lateral flow assay. The amplified target sequence employed was hsp70 mRNA, production of which is stimulated via a brief heat shock. The described method was capable of detecting one oocyst in 10 μL using flow-cytometer-counted samples. Only viable oocysts were detected, as confirmed using 4′,6-diamidino-2-phenylindole and propidium iodide (DAPI/PI) staining. The detection system was challenged by detecting oocysts in the presence of large numbers of common waterborne microorganisms and packed pellet material filtered from environmental water samples. When the method was compared with EPA Method 1622 for C. parvum detection, highly comparable results were obtained. Since the described detection system yields unambiguous results within 4.5 h, it is an ideal method for monitoring the safety of drinking water.
Microbiological contamination of foods continues to be a major concern in public health. Biological toxins are one class of important contaminants that can cause various human diseases. Outbreaks related to contamination by biological toxins or toxin-producing microorganisms have made it extremely important to develop rapid (approximately 20 min), sensitive and cost-effective analytical methods. This paper describes the development of a sensitive bioassay for the detection of cholera toxin (CT) in selected seafood samples, using ganglioside-incorporated liposomes. In this study, the assays were run with food samples spiked with various concentrations of CT. The limit of detection (LOD) increased by a factor of about 10–20 in most food samples, compared with the LOD in the buffer system previously reported. However, the LOD of toxins in food samples (8 × 10–3 × 103 fg/mL for CT) was still comparable to, or lower than, that previously reported for other assays. The results from this study demonstrate that the bioassays using ganglioside-liposomes can detect the toxin directly in the field screening of food samples rapidly, simply and reliably, without the need for complex instrumentation.
Attention to peanut allergy has been rising rapidly for the last 5 y, because it accounts for the majority of severe food-related anaphylaxis, it tends to appear early in life, and it usually is not resolved. Low milligram amounts of peanut allergens can induce severe allergic reactions in highly sensitized individuals, and no cure is available for peanut allergy. This review presents updated information on peanut allergy, peanut allergens (Ara h1 to h8), and available methods for detecting peanuts in foods. These methods are based on the detection of either peanut proteins or a specific DNA fragment of peanut allergens. A summary of published methods for detecting peanut in foods is given with a comparison of assay formats, target analyte, and assay sensitivity. Moreover, a summary of the current availability of commercial peanut allergen kits is presented with information about assay format, target analyte, sensitivity, testing time, company/kit name, and AOAC validation.
Cholera, an acute infectious disease associated with water and seafood contamination, is caused by the bacterium Vibrio cholerae, which lives and colonizes in the small intestine and secretes cholera toxin (CT), a causative agent for diarrhea in humans. Based on earlier lateral flow assays, a flow injection liposome immunoanalysis (FILIA) system with excellent sensitivity was developed in this study for the determination of CT at zeptomole levels. Ganglioside (GM1), found to have specific affinity toward CT, was inserted into the phospholipid bilayer during the liposome synthesis. These GM1-sensitized, sulforhodamine B (SRB) dye-entrapping liposomes were used as probes in the FILIA system. Anti-CT antibodies were immobilized in its microcapillary. CT was detected by the formation of a sandwich complex between the immobilized antibody and GM1 liposomes. During the assay, the sample was introduced first into the column, and then liposomes were injected to bind to all CT captured by the antibody in the microcapillary. Subsequently, the SRB dye molecules were released from the bound liposomes via the addition of the detergent octyl glucopyranoside. The released dye molecules were transported to a flow-through fluorescence detector for quantification. The FILIA system was optimized with respect to flow rate, antibody concentration, liposome concentration, and injected sample volume. The calibration curve for CT had a linear range of 10-16 to 10-14 g mL-1. The detection limit of this immunosensor was 6.6 x 10(-17) g mL-1 in 200-microL samples (equivalent to 13 ag or 1.1 zmol).
Quantum dots (QDs) and silica nanoparticles (SNs) are relatively new classes of fluorescent probes that overcome the limitations encountered by organic fluorophores in bioassay and biological imaging applications. We encapsulated QDs and SNs in liposomes and separated nanoparticle-loaded liposomes from unencapsulated nanoparticles by size exclusion chromatography. Fluorescence correlation spectroscopy was used to measure the average number of nanoparticles inside each liposome. Results indicated that nanoparticle-loaded liposomes were formed and separated from unencapsulated nanoparticles by using a Sepharose gel. As expected, fluorescence self-quenching of nanoparticles inside liposomes was not observed. Each liposome encapsulated an average of three QDs. These studies demonstrated that nanoparticles could be successfully encapsulated into liposomes and provided a methodology to quantify the number of nanoparticles inside each liposome by fluorescence correlation spectroscopy.
A novel universal reagent for immunoassays, protein G-liposomal nanovesicles has been developed and successfully used in an immunomagnetic bead sandwich assay for the detection of Escherichia coli O157:H7 [C.-S. Chen, A.J. Baeumner, R.A. Durst, Talanta 67 (2005) 205]. To demonstrate the universal capability of protein G-liposomal nanovesicles, this reagent was used to develop an array-based immunosorbent assay for the simultaneous detection of E. coli O157:H7, Salmonella, and Listeria monocytogenes. Both direct and competitive immunoassay formats were used to demonstrate the feasibility of detecting multiple analytes in a single test by using universal protein G-liposomal nanovesicles. Both pure and mixed cultures were examined in the direct immunoassay format. Results indicate that the limits of detection (LODs) of the direct assay for E. coli O157:H7, Salmonella enterica serovar Typhimurium and L. monocytogenes in pure cultures were approximately 100, 500 and 1.5 × 104 CFU/ml, respectively. In mixed cultures, the LODs were approximately 3.1 × 103, 7.8 × 104, and 7.9 × 105 CFU/ml. In the competitive assay format, the LODs for E. coli O157:H7, S. enterica serovar Typhimurium, and L. monocytogenes were approximately 1.5 × 104, 5 × 104, and 1.2 × 105 CFU/ml for the pure cultures. These results showed that protein G-liposomal nanovesicles can be successfully used in a simultaneous immunoassay for several food-borne pathogens, thereby demonstrating that they are effective universal reagents for use in immunoassays.