Forty-two patients (28 men and 14 women) with acute myocardial infarction (35 Q, seven non-Q wave) were injected with 2.0 mCi indium 111-labeled antimyosin (AM) monoclonal antibody (111In AM) within 48 hours of the onset of chest pain. Forty-eight hours later (72-96 hours after onset of chest pain), patients were injected with 2.2 mCi thallium 201, and two sets of single-photon emission computed tomography (SPECT) images were obtained simultaneously using dual energy windows set for the 247 keV indium photopeak and the 70 keV thallium peak. Seventeen patients had repeat scans at 4 hours. 111In AM uptake and 201Tl defects were localized to one or more of 24 coronal and sagittal segments. Scans with only 201Tl defects and corresponding 111In AM uptake were classified as matches; scans with unmatched 201Tl defects in addition to matching regions corresponding to electrocardiographic infarct location were classified as mismatches; and scans with 201Tl and 111In AM uptake in the same segments were classified as overlap. Scan patterns were correlated with clinical evidence for residual ischemia occurring within 6 weeks of infarct and including infarct extension, recurrent angina, and positive predischarge low-level or 6-week symptom-limited stress tests and with coronary anatomy. Fourteen patients had only matching patterns (group 1), 23 had mismatches (group 2), and five had 201Tl-111In overlap as the predominant pattern. None of the patients in group 1 had previous myocardial infarction; in each, the matched area corresponded to the Q wave location on electrocardiogram, and none had further in-hospital ischemic events or positive stress tests.(ABSTRACT TRUNCATED AT 250 WORDS)
Myocardial infarct size was measured by single photon emission computed tomography (SPECT) following injection of indium-111 antimyosin in 27 patients (18 male and 9 female; mean age 57.4 +/- 10.5 years, range 37 to 75) who had acute transmural myocardial infarction (MI). These 27 patients represent 27 of 35 (77%) consecutive patients with acute Q-wave infarctions who were injected with indium-111 antimyosin. In the remaining 8 patients either tracer uptake was too faint or the scans were technically inadequate to permit infarct sizing from SPECT reconstructions. In the 27 patients studied, infarct location by electrocardiogram was anterior in 15 and inferoposterior in 12. Nine patients had a history of prior infarction. Each patient received 2 mCi of indium-111 antimyosin followed by SPECT imaging 48 hours later. Infarct mass was determined from coronal slices using a threshold value obtained from a human torso/cardiac phantom. Infarct size ranged from 11 to 87 g mean 48.5 +/- 24). Anterior infarcts were significantly (p less than 0.01) larger (60 +/- 20 g) than inferoposterior infarcts (34 +/- 21 g). For patients without prior MI, there were significant inverse correlations between infarct size and ejection fraction (r = 0.71, p less than 0.01) and wall motion score (r = 0.58, p less than 0.01) obtained from predischarge gated blood pool scans. Peak creatine kinase-MB correlated significantly with infarct size for patients without either reperfusion or right ventricular infarction (r = 0.66). Seven patients without prior infarcts had additional simultaneous indium-111/thallium-201 SPECT studies using dual energy windows.(ABSTRACT TRUNCATED AT 250 WORDS)
Myocardial perfusion in ten normal volunteers and 20 patients with coronary artery disease documented by recent coronary arteriography was studied with 99mTc-labeled SQ30217 and 201TI. Plantar 201TI imaging followed standard treadmill exercise and planar SQ30217 imaging followed upright bicycle exercise, performed to angina, or the same double product achieved on the treadmill test. Upright anterior, 30 degrees left anterior oblique, and 60 degrees left anterior oblique images were obtained for 3, 6, and 9 min, respectively, starting 2 min after injection of 15 mCi of 99mTc SQ30217. A second 15-mCi dose was injected at rest approximately 2 hr later, and the same imaging protocol was followed. No adverse reactions or laboratory abnormalities attributable to SQ30217 were observed. All scans on the normal volunteers were interpreted as normal. Qualitative readings of both tests were equally sensitive for detecting patients with coronary disease (SQ30217 - 16/20, TI - 17/20, p = NS) and identifying abnormal vessels (SQ30217 - 19/45, TI - 21/45, p = NS). Both agents were falsely positive in 1/15 vessels. Ten vascular regions showed persistent abnormalities on resting SQ30217 scans; eight of these were distal to stenoses of at least 90% and three were also abnormal on thallium redistribution images. Hepatic uptake of SQ30217 obscured inferoapical segments in some views in 14/20 patients but did not interfere with abnormal vessel identification.