Aim: The aim of this study was to measure and compare the output factor (OF) of a CyberKnife Robotic Radiosurgery System with eight different small field detectors and validate with Technical Report Series (TRS) report 483. Background: Accurate dosimetry of CyberKnife system is limited due to the challenges in small field dosimetry. OF is a vital dosimetric parameter used in the photon beam modeling and any error would affect the dose calculation accuracy. Materials and Methods: In this study, the OF was measured with eight different small-field detectors for the 12 IRIS collimators at 800 mm SAD setup at 15 mm depth. The detectors used were PTW 31016 PinPoint 3D, IBA PFD shielded diode, IBA EFD unshielded diode, IBA SFD unshielded diode (stereotactic), PTW 60008 shielded diode, PTW 60012 unshielded diode, PTW 60018 unshielded diode (stereotactic), and PTW 60019 CVD diamond detector. OF was obtained after correcting for field output correction factors from IAEA TRS No. 483. Results: The field OFs in CyberKnife are derived from the measured data by applying the correction factors from Table 23 in TRS 483 for the eight small field detectors. These field OFs matched within 2% of peer-reviewed published values. The range and standard deviation showed a decreasing trend with collimator diameter. Conclusion: The field OF obtained after applying the appropriate correction factor from TRS 483 matched well with the peer-reviewed published OFs. The inter-detector variation showed a decreasing trend with increasing collimator field size. This study gives physicists confidence in measuring field OFs while using small field detectors mentioned in this work.
AbstractThe main objectives of this study are to (1) analyze the sensitivity of various gamma index passing rates using different types of detectors having different resolutions and (2) investigate the sensitivity of various gamma criteria in intensity‐modulated radiation therapy (IMRT) and volumetrically modulated arc therapy (VMAT) quality assurance (QA) for the detection of systematic multileaf collimator (MLC) errors using an electronic portal imaging device (EPID) and planar (MapCheck2) and cylindrical (ArcCheck) diode arrays. We also evaluated whether the correlation between the gamma passing rate (%GP) and the percentage dose error (%DE) of the dose–volume histogram (DVH) metrics was affected by the finite spatial resolution of the array detectors. We deliberately simulated systematic MLC errors of 0.25 mm, 0.50 mm, 0.75 mm, and 1 mm in five clinical nasopharyngeal carcinoma cases, thus creating 40 plans with systematic MLC errors. All measurements were analyzed field by field using gamma criteria of 3%/3 mm, 3%/2 mm, 3%/1 mm, and 2%/2 mm, with a passing rate of 90% applied as the action level. Our results showed that 3%/1 mm is the most sensitive criterion for the detection of systematic MLC errors when using EPID, with the steepest slope from the best‐fit line and an area under the receiver operating characteristic (ROC) curve >0.95. With respect to the 3%/1 mm criterion, a strong correlation between %GP and %DE of the DVH metrics was observed only when using the EPID. However, with respect to the same criteria, a 0.75 mm systematic MLC error can go undetected when using MapCheck2 and ArcCheck, with an area under the ROC curve <0.75. Furthermore, a lack of correlation between %GP and %DE of the DVH metrics was observed in MapCheck2 and ArcCheck. In conclusion, low‐spatial resolution detectors can affect the results of a per‐field gamma analysis and render the analysis unable to accurately separate erroneous and non‐erroneous plans. Meeting these new sensitive criteria is expected to ensure clinically acceptable dose errors.
AIM:The aim of this study was to investigate the sensitivity of the trajectory log file based quality assurance to detect potential errors such as MLC positioning and gantry positioning by comparing it with EPID measurement using the most commonly used criteria of 3%/3 mm. MATERIALS AND METHODS:An in-house program was used to modified plans using information from log files, which can then be used to recalculate a new dose distribution. The recalculated dose volume histograms (DVH) were compared with the originals to assess differences in target and critical organ dose. The dose according to the differences in DVH was also compared with dosimetry from an electronic portal imaging device. RESULTS:In all organs at risk (OARs) and planning target volumes (PTVs), there was a strong positive linear relationship between MLC positioning and dose error, in both IMRT and VMAT plans. However, gantry positioning errors exhibited little impact in VMAT delivery. For the ten clinical cases, no significant correlations were found between gamma passing rates under the criteria of 3%/3 mm for the composite dose and the mean dose error in DVH (r < 0.3, P > 0.05); however, a significant positive correlation was found between the gamma passing rate of 3%/3 mm (%) averaged over all fields and the mean dose error in the DVH of the VMAT plans (r = 0.59, P < 0.001). CONCLUSIONS:This study has successfully shown the sensitivity of the trajectory log file to detect the impact of systematic MLC errors and random errors in dose delivery and analyzed the correlation of gamma passing rates with DVH.
PURPOSEThe purpose of this study was to assess the potential of 3D dosimetry for flattened and flattened filter free stereotactic rotational delivery in high definition MLC using 729-detector array with Octavius 4D phantom METHODS: Twenty rapid arc plans were assessed for this study. For each patient two plans for 6X and 6FFF photon beams were generated with same prescription and critical organ constraints in Eclipse TPS version 13.0 using high definition MLC. Verification plans were generated in scanned Octavius 4D phantom in TPS. 3D dose measurements were collected from 729-ion chamber detector array in Octavius 4D phantom using verisoft software v 6.0. TPS calculated dose was compared with measured 3D dose in verisoft using the following gamma analysis parameters such as 3D volumetric, 3D planar and 2D global gamma in transverse, sagittal and coronal planes for 3mm/3% and 2mm/2% distance to agreement criteria.Passing rate and arithmetic mean of global gamma were analysed for 2D and 3D global gamma in all planes.RESULTSThe average number of dose points passing rate for 2D global gamma with 3mm/3% criteria in transverse, sagittal and coronal planes was 99.06%±2.89%, 98.8%±0.88% and 99.06%±91%, respectively. For 2mm/2% criteria 97.86%±2.26%, 94.49± 2.64% and 94.34%±2.9% was observed. In 3D planar global gamma with 3mm/3% was 99.53%±0.49%, 98.93%±1.03% and 99.29%±1.29%, for 2mm 2% criteria was 97.50%±2.24%, 94.5%±2.5% and 95.38%±4.5%. The maximum arithmetic mean gamma deviation of 0.505%±0.13% was observed in coronal plane for 2D global gamma with 2mm/2% criteria. The 3D volumetric gamma passing rate was observed as 99.61%±0.433% for 3mm /3% and 95.91%±2.51% for 2mm/2%.CONCLUSIONThe objective assessment of 3D dosimetry have demonstrated that the rotational delivery accuracy for flattened and flattened filter free stereotactic plans can be verified by using Octavius system comprising with 729 ion chamber array and Octavius 4D phantom.
Purpose:To study and compare the penumbra of 6 MV and 15 MV photon beam profiles after deconvoluting different volume ionization chambers.Methods:0.125cc Semi‐Flex chamber, Markus Chamber and PTW Farmer chamber were used to measure the in‐plane and cross‐plane profiles at 5 cm depth for 6 MV and 15 MV photons. The profiles were measured for various field sizes starting from 2×2 cm till 30×30 cm. PTW TBA scan software was used for the measurements and the “deconvolution” functionality in the software was used to remove the volume averaging effect due to finite volume of the chamber along lateral and longitudinal directions for all the ionization chambers. The predicted true profile was compared and the change in penumbra before and after deconvolution was studied.Results:After deconvoluting the penumbra decreased by 1 mm for field sizes ranging from 2 × 2 cm till 20 x20 cm. This is observed for along both lateral and longitudinal directions. However for field sizes from 20 × 20 till 30 ×30 cm the difference in penumbra was around 1.2 till 1.8 mm. This was observed for both 6 MV and 15 MV photon beams. The penumbra was always lesser in the deconvoluted profiles for all the ionization chambers involved in the study. The variation in difference in penumbral values were in the order of 0.1 till 0.3 mm between the deconvoluted profile along lateral and longitudinal directions for all the chambers under study. Deconvolution of the profiles along longitudinal direction for Farmer chamber was not good and is not comparable with other deconvoluted profiles.Conclusion:The results of the deconvoluted profiles for 0.125cc and Markus chamber was comparable and the deconvolution functionality can be used to overcome the volume averaging effect.
Purpose: The aim of the study is to characterize a two dimensional liquid filled detector array SRS 1000 for routine QA in Cyberknife Robotic Radiosurgery system. Methods: SRS 1000 consists of 977 liquid filled ionization chambers and is designed to be used in small field SRS/SBRT techniques. The detector array has got two different spacial resolutions. Till field size of 5.5×5.5 cm the spacial resolution is 2.5mm (center to center) and after that till field size of 11 × 11 cm the spacial resolution is 5mm. The size of the detector is 2.3 × 2.3 0.5 mm with a volume of .003 cc. The CyberKnife Robotic Radiosurgery System is a frameless stereotactic radiosurgery system in which a LINAC is mounted on a robotic manipulator to deliver beams with a high sub millimeter accuracy. The SRS 1000's MU linearity, stability, reproducibility in Cyberknife Robotic Radiosurgery system was measured and investigated. The output factors for fixed and IRIS collimators for all available collimators (5mm till 60 mm) was measured and compared with the measurement done with PTW pin-point ionization chamber. Results: The MU linearity was measured from 2 MU till 1000 MU for doserates in the range of 700cGy/min – 780 cGy/min and compared with the measurement done with pin point chamber The MU linearity was with in 3%. The detector arrays stability and reproducibility was excellent and was withinin 0.5% The measured output factors showed an agreement of better than 2% when compared with the measurements with pinpoint chamber for both fixed and IRIS collimators with all available field sizes. Conclusion: We have characterised PTW 1000 SRS as a precise and accurate measurement tool for routine QA of Cyberknife Robotic radiosurgery system.
Organ motions during inter-fraction and intra-fraction radiotherapy introduce errors in dose delivery, irradiating excess of normal tissue, and missing target volume. Lung and heart involuntary motions cause above inaccuracies and gated dose delivery try to overcome above effects. Present work attempts a novel method to verify dynamic dose delivery using a four-dimensional (4D) phantom. Three patients with mobile target are coached to maintain regular and reproducible breathing pattern. Appropriate intensity projection image set generated from 4D-computed tomography (4D-CT) is used for target delineation. Intensity modulated radiotherapy plans were generated on selected phase using CT simulator (Siemens AG, Germany) in conjunction with "Real-time position management" (Varian, USA) to acquire 4D-CT images. Verification plans were generated for both ion chamber and Gafchromic (EBT) film image sets. Gated verification plans were delivered on the phantom moving with patient respiratory pattern. We developed a MATLAB-based software to generate maximum intensity projection, minimum intensity projections, and average intensity projections, also a program to convert patient breathing pattern to phantom compatible format. Dynamic thorax quality assurance (QA) phantom (Computerized Imaging Reference Systems type) is used to perform the patient specific QA, which holds an ion chamber and film to measure delivered radiation intensity. Exposed EBT films are analyzed and compared with treatment planning system calculated dose. The ion chamber measured dose shows good agreement with planned dose within ± 0.5% (0.203 ± 0.57%). Gamma value evaluated from EBT film shows passing rates 92-99% (96.63 ± 3.84%) for 3% dose and 3 mm distance criteria. Respiratory gated treatment delivery accuracy is found to be within clinically acceptable level.
Purpose: The purpose of this study was to compare dosimetric indices of Cyberknife versus Linac for localised prostate cancer Methods: In this study, twenty patients were taken from Cyberknife Multiplan TPS v 4.6.0. All these patients underwent hypo fractionated boost treatment for localised prostate cancer in Cyberknife with the prescription dose of 18Gy in 3 fractions. For each patient VMAT stereotactic plans were generated in Monaco TPS v 5.0 using Elekta beam modulator MLC machine for 6MV photon beam. The plans quality were evaluated by comparing dosimetry indices such that D95, D90, D5 for target volume and V100, V80, V50, V30 for critical organs. The p values were calculated for target and OAR to ascertain the significant differences. Results: For each case, D95 of target coverage was achieved with 100% prescription dose with p value of 0.9998. The p value for D90, D5 and V100 for linac and Cyberknife plans was 0.9938, 0.9918 and 0.9838 respectively. For rectum, rectum-PTV and bladder doses were significantly less in Cyberknife compared to linac plans. For rectum, rectum-PTV and bladder at V100 the p value is 0.2402, 0.002, and 0.1615 respectively. Other indices V80, V50 and V30 were comparable in both plans. Conclusion: This study demonstrated that both linac and Cyberknife plans were shown adequate target coverage, while in Cyberknife the treatment time is longer and more MUs to be delivered. However, better conformity, lesser doses to the critical organs and dose gradient outside target for localised prostate treatment were achieved in Cyberknife plans due to multiple non coplanar beam arrangements.
Purpose:To evaluate the impact of dose calculation algorithm on the dose distribution of biologically optimized Volumatric Modulated Arc Therapy (VMAT) plans for Esophgeal cancer.Methods:Eighteen retrospectively treated patients with carcinoma esophagus were studied. VMAT plans were optimized using biological objectives in Monaco (5.0) TPS for 6MV photon beam (Elekta Infinity). These plans were calculated for final dose using Monte Carlo (MC), Collapsed Cone Convolution (CCC) & Pencil Beam Convolution (PBC) algorithms from Monaco and Oncentra Masterplan TPS. A dose grid of 2mm was used for all algorithms and 1% per plan uncertainty maintained for MC calculation. MC based calculations were considered as the reference for CCC & PBC. Dose volume histogram (DVH) indices (D95, D98, D50 etc) of Target (PTV) and critical structures were compared to study the impact of all three algorithms.Results:Beam models were consistent with measured data. The mean difference observed in reference with MC calculation for D98, D95, D50 & D2 of PTV were 0.37%, −0.21%, 1.51% & 1.18% respectively for CCC and 3.28%, 2.75%, 3.61% & 3.08% for PBC. Heart D25 mean difference was 4.94% & 11.21% for CCC and PBC respectively. Lung Dmean mean difference was 1.5% (CCC) and 4.1% (PBC). Spinal cord D2 mean difference was 2.35% (CCC) and 3.98% (PBC). Similar differences were observed for liver and kidneys. The overall mean difference found for target and critical structures was 0.71±1.52%, 2.71±3.10% for CCC and 3.18±1.55%, 6.61±5.1% for PBC respectively.Conclusion:We observed a significant overestimate of dose distribution by CCC and PBC as compared to MC. The dose prediction of CCC is closer (<3%) to MC than that of PBC. This can be attributed to poor performance of CCC and PBC in inhomogeneous regions around esophagus. CCC can be considered as an alternate in the absence of MC algorithm.
Purpose:To quantify the dosimetric accuracy of respiratory gated stereotactic body radiation therapy delivery using dynamic thorax phantom.Methods:Three patients with mobile target (2 lung, 1liver) were chosen. Retrospective 4DCT image sets were acquired for using Varian RPM system. An in‐house MATLAB program was designed for MIP, MinIP and AvgIP generation. ITV was contoured on MIP image set for lung patients and on MinIP for liver patient. Dynamic IMRT plans were generated on selected phase bin image set in Eclipse (v10.0) planning system. CIRS dynamic thorax phantom was used to perform the dosimetric quality assurance. Patient breathing pattern file from RPM system was converted to phantom compatible file by an in‐house MATLAB program. This respiratory pattern fed to the CIRS dynamic thorax phantom. 4DCT image set was acquired for this phantom using patient breathing pattern. Verification plans were generated using patient gating window and delivered on the phantom. Measurements were carried out using with ion chamber and EBT2 film. Exposed films were analyzed and evaluated in FilmQA software.Results:The stability of gated output in comparison with un‐gated output was within 0.5%. The Ion chamber measured and TPS calculated dose compared for all the patients. The difference observed was 0.45%, −0.52% and −0.54 for Patient 1, Patient2 and Patient 3 respectively.Gamma value evaluated from EBT film shows pass rates from 92.41% to 99.93% for 3% dose difference and 3mm distance to agreement criteria.Conclusion:Dosimetric accuracy of respiratory gated SBRT delivery for lung and liver was dosimetrically acceptable. The Ion chamber measured dose was within 0.203±0.5659% of the expected dose. Gamma pass rates were within 96.63±3.84% of the expected dose.
In advanced, intensity-modulated external radiotherapy facility, the multileaf collimator has a decisive role in the beam modulation by creating multiple segments or dynamically varying field shapes to deliver a uniform dose distribution to the target with maximum sparing of normal tissues. The position of each MLC leaf has become more critical for intensity-modulated delivery (step-and-shoot IMRT, dynamic IMRT, and VMAT) compared to 3D CRT, where it defines only field boundaries. We analyzed the impact of the MLC positional errors on the dose distribution for volumetric-modulated arc therapy, using a 3D dosimetry system. A total of 15 VMAT cases, five each for brain, head and neck, and prostate cases, were retrospectively selected for the study. All the plans were generated in Monaco 3.0.0v TPS (Elekta Corporation, Atlanta, GA) and delivered using Elekta Synergy linear accelerator. Systematic errors of +1, +0.5, +0.3, 0, -1, -0.5, -0.3 mm were introduced in the MLC bank of the linear accelerator and the impact on the dose distribution of VMAT delivery was measured using the COMPASS 3D dosimetry system. All the plans were created using single modulated arcs and the dose calculation was performed using a Monte Carlo algorithm in a grid size of 3 mm. The clinical endpoints D-95%, D-50%, D-2%, and D-max,D-20%, D50% were taken for the evaluation of the target and critical organs doses, respectively. A significant dosimetric effect was found for many cases even with 0.5 mm of MLC positional errors. The average change of dose D95% to PTV for +/- 1 mm, +/- 0.5 mm, and +/- 0.3 mm was 5.15%, 2.58%, and 0.96% for brain cases; 7.19%, 3.67%, and 1.56% for head and neck cases; and 8.39%, 4.5%, and 1.86% for prostate cases, respectively. The average deviation of dose Dmax was 5.4%, 2.8%, and 0.83% for brainstem in brain cases; 8.2%, 4.4%, and 1.9% for spinal cord in H & N; and 10.8%, 6.2%, and 2.1% for rectum in prostate cases, respectively. The average changes in dose followed a linear relationship with the amount of MLC positional error, as can be expected. MLC positional errors beyond +/- 0.3 mm showed a significant influence on the intensity-modulated dose distributions. It is, therefore, recommended to have a cautious MLC calibration procedure to sufficiently meet the accuracy in dose delivery.
Aim: The aim of this study is to evaluate performance of ArcCHECK diode array detector for the volumetric modulated arc therapy (VMAT) patient specific quality assurance (QA). VMAT patient specific QA results were correlated with ion chamber measurement. Dose response of the ArcCHECK detector was studied.Background: VMAT delivery technique improves the dose distribution. It is complex in nature and requires proper QA before its clinical implementation. ArcCHECK is a novel three dimensional dosimetry system.Materials and methods: Twelve retrospective VMAT plans were calculated on ArcCHECK phantom. Point dose and dose map were measured simultaneously with ion chamber (IC-15) and ArcCHECK diode array detector, respectively. These measurements were compared with their respective TPS calculated values.Results: The ion chamber measurements are in good agreement with TPS calculated doses. Mean difference between them is 0.50% with standard deviation of 0.51%. Concordance correlation coefficient (CCC) obtained for ion chamber measurements is 0.9996. These results demonstrate a strong correlation between the absolute dose predicted by our TPS and the measured dose. The CCC between ArcCHECK doses and TPS predictions on the CAX was found to be 0.9978. In gamma analysis of dose map, the mean passing rate was 98.53% for 3% dose difference and 3 mm distance to agreement.Conclusions: The VMAT patient specific QA with an ion chamber and ArcCHECK phantom are consistent with the TPS calculated dose. Statistically good agreement was observed between ArcCHECK measured and TPS calculated. Hence, it can be used for routine VMAT QA. (C) 2015 Greater Poland Cancer Centre. Published by Elsevier Sp. z o.o. All rights reserved.
Aim: To analyse the preliminary results of CyberKnife stereotactic radiotherapy (SBRT) boost in primary head and neck cancer patients among Indian population.Methods and materials: A total of nine patients of primary head and neck cancer were treated with CyberKnife SBRT boost after intensity-modulated radiation therapy (IMRT). The median phase 1 IMRT dose was 54 Gy/27 fractions. Histological types included squamous cell carcinoma (n = 7) and adenoid cystic carcinoma (n = 2). Response was evaluated using positron emission tomography/computed tomography and detailed clinical examination.Results: As a preliminary analysis with median follow up of 8 months (range: 6-19 months), phase 2 median tumour volume of 16 center dot 3 cc and a median dose of 5 Gy per fraction, eight patients had loco-regionally stable disease and one had distant metastasis. With objective assessment five patients had complete response. Treatment was well tolerated with no grade 3 or more acute toxicities directly related to CyberKnife boost.Conclusion: CyberKnife SBRT boost is an attractive option for primary head and neck cancers especially where disease is in close proximity to critical structures hindering radical dose delivery. Future prospective analysis and optimum assessment of total biological effective dose (BED) in a properly selected case might actually benefit the use of CyberKnife SBRT boost.
Purpose:The purpose of this study was to validate the advent of COMPASS 3D dosimetry as a routine pre treatment verification tool with commercially available CMS Monaco and Oncentra Masterplan planning system.Methods:Twenty esophagus patients were selected for this study. All these patients underwent radical VMAT treatment in Elekta Linac and plans were generated in Monaco v5.0 with MonteCarlo(MC) dose calculation algorithm. COMPASS 3D dosimetry comprises an advanced dose calculation algorithm of collapsed cone convolution(CCC). To validate CCC algorithm in COMPASS, The DICOM RT Plans generated using Monaco MC algorithm were transferred to Oncentra Masterplan v4.3 TPS. Only final dose calculations were performed using CCC algorithm with out optimization in Masterplan planning system. It is proven that MC algorithm is an accurate algorithm and obvious that there will be a difference with MC and CCC algorithms. Hence CCC in COMPASS should be validated with other commercially available CCC algorithm. To use the CCC as pretreatment verification tool with reference to MC generated treatment plans, CCC in OMP and CCC in COMPASS were validated using dose volume based indices such as D98, D95 for target volumes and OAR doses.Results:The point doses for open beams were observed <1% with reference to Monaco MC algorithms. Comparisons of CCC(OMP) Vs CCC(COMPASS) showed a mean difference of 1.82%±1.12SD and 1.65%±0.67SD for D98 and D95 respectively for Target coverage. Maximum point dose of −2.15%±0.60SD difference was observed in target volume. The mean lung dose of −2.68%±1.67SD was noticed between OMP and COMPASS. The maximum point doses for spinal cord were −1.82%±0.287SD.Conclusion:In this study, the accuracy of CCC algorithm in COMPASS 3D dosimetry was validated by compared with CCC algorithm in OMP TPS. Dose calculation in COMPASS is feasible within < 2% in comparison with commercially available TPS algorithms.
Purpose: The purpose of this study was to evaluate multiple brain metastases stereotactic treatment planning of Cyberknife versus linac using dose volume based indices. Methods: Fifteen multiple brain metastases patients were taken for this study from Cyberknife Multiplan TPSv4.6.0. All these patients underwent stereotactic treatment in Cyberknife. For each patient VMAT stereotactic treatment plan was generated in MONACO TPSv5.0 using Elekta beam modulator MLC and matched the delivered plan. A median dose of 8.5Gy(range 7–12Gy) per fraction was prescribed. Tumor volume was in the range of 0.06–4.33cc. Treatment plan quality was critically evaluated by comparing DVH indices such as D98, D95, CI, and HI for target volumes. Maximum point doses and volume doses were evaluated for critical organs. Results: For each case, target coverage of D98 was achieved with 100% prescription dose with SD of 0.29% and 0.41% in Linac and Cyberknife respectively. The average conformity index(CI) of 1.26±0.0796 SD for Cyberknife and 1.92±0.60SD for linac were observed. Better homogeneity Index (HI) of 1.17±0.09SD was observed in linac as compared to Cyberknife HI of 1.24±0.05SD.All the critical organ doses were well within tolerance limit in both linac and Cyberknife plans. There is no significant difference of maximum point doses for brainstem and optic chiasm. Treatment time and number of monitor units are more in Cyberknife compared to linac. The average volume receiving 12Gy in whole brain was 6% and 12% for Cyberknife and linac respectively. 1000cc of whole brain received 60% lesser dose in Linac compared to Cyberknife in all cases. Conclusion: The study shows that dosimetrically comparable plans are achievable Cyberknife and Linac. However, a better conformity, target coverage, lesser OAR dose is achieved with Cyberknife due to greater degrees of freedom with robotic gantry and smaller collimator for multiple targets.