Purpose: Menisci transfer axial loads, while increasing the load-bearing tibiofemoral contact area and decreasing tibiofemoral contact pressure (CP). Numerous clinical and experimental studies agree that an increased CP is one predominant indicator for post-traumatic osteoarthritis (PTOA) of the knee joint. However, due to the immense variability in experimental test setups and wide range of treatment possibilities in meniscus surgery, it is difficult to objectively assess their impact on the CP determination, which is clearly crucial for knee joint health. Therefore, the aim of this systematic review is to investigate the influence of different meniscal injuries and their associated surgical treatments on the CP. Secondly, the influence of different test setups on CP measurements is assessed. On the basis of these results, we established the basis for recommendations for future investigations with the aim to determine CPs under different meniscal states. Methods: This review was conducted in accordance with the PRISMA guidelines. Studies were identified through a systematic literature search in Cochrane, PubMed and Web of Science databases. Literature was searched through pre-defined keywords and medical subject headings. Results: This review indicates a significant increase of up to 235% in peak CP when comparing healthy joints and intact menisci with impaired knee joints, injured or resected menisci. In addition, different test setups were indicated to have major influences on CP: The variety of test setups ranged from standard material testing machines, including customized setups via horizontal and vertical knee joint simulators, through to robotic systems. Differences in applied axial knee joint loads ranged from 0 N up to 2,700 N and resulted unsurprisingly in significantly different peak CPs of between 0.1 and 12.06 MPa. Conclusion: It was shown that untreated traumatic meniscal tears result in an increased CP. Surgical repair intervention were able to restore the CP comparable to the healthy, native condition. Test setup differences and particularly axial joint loading variability also led to major CP differences. In conclusion, when focusing on CP measurements in the knee joint, transparent and traceable in vitro testing conditions are essential to allow researchers to make a direct comparison between future biomechanical investigations.
Background: Protective knee braces are used for rehabilitation or prevention. Due to poor patient compliance or slippage, the brace might be misaligned with the knee axis. Objectives: Does a misaligned knee brace stress the anterior cruciate ligament? Study design: It is an experimental study. Methods: A strain sensor was implanted on the anterior cruciate ligament in eight limbs. The limbs were mounted in a knee simulator, muscle forces were applied and a cyclic motion from 10° to 60° flexion was performed under three conditions: unbraced, braced and with a misaligned brace. Outcome measures: The outcome measures were anterior cruciate ligament strain and three-dimensional kinematics of the knee joint. Results: The correctly aligned brace significantly reduced the anterior cruciate ligament strain at 10° compared to the unbraced condition from 0% to −1.54% (standard deviation = 1.4). The misaligned brace neutralised the effect of bracing to −0.06% (standard deviation = 1.1) anterior cruciate ligament strain. At 60° flexion angle, bracing had no statistically significant effect on the anterior cruciate ligament strain compared to the unbraced knee: −2.58% (standard deviation = 0.8) versus −1.64% (standard deviation = 1.0). The anterior cruciate ligament in the misaligned braced knee at 60° flexion with a strain of −1.1% (standard deviation = 0.9) was significantly more stressed than in the correctly aligned condition. An effect of bracing on knee kinematics was not detected. Conclusion: A correctly aligned knee brace reduced anterior cruciate ligament strain. By contrast, a misaligned brace tended to increase the anterior cruciate ligament strain compared to the unbraced knee. Clinical relevance The correct alignment of the brace was identified as a key factor decisively influencing the effectiveness of bracing.
The in vitro determination of realistic loads acting in knee ligaments, articular cartilage, menisci and their attachments during daily activities require the creation of physiological muscle forces, ground reaction force and unconstrained kinematics. However, no in vitro test setup is currently available that is able to simulate such physiological loads during squatting and jump landing exercises. Therefore, a novel knee joint simulator allowing such physiological loads in combination with realistic, rapid movements is presented. To gain realistic joint positions and muscle forces serving as input parameters for the simulator, a combined in vivo motion analysis and inverse dynamics (MAID) study was undertaken with 11 volunteers performing squatting and jump landing exercises. Subsequently, an in vitro study using nine human knee joint specimens was conducted to prove the functionality of the simulator. To do so, slow squatting without muscle force simulation representing quasi-static loading conditions and slow squatting and jump landing with physiological muscle force simulation were carried out. During all tests ground reaction force, tibiofemoral contact pressure, and tibial rotation characteristics were simultaneously recorded. The simulated muscle forces obtained were in good correlation (0.48 ≤ R ≤ 0.92) with those from the in vivo MAID study. The resulting vertical ground reaction force showed a correlation of R = 0.93. On the basis of the target parameters of ground reaction force, tibiofemoral contact pressure and tibial rotation, it could be concluded that the knee joint load was loaded physiologically. Therefore, this is the first in vitro knee joint simulator allowing squatting and jump landing exercises in combination with physiological muscle forces that finally result in realistic ground reaction forces and physiological joint loading conditions.
Mechanostimulation by low-magnitude high frequency vibration (LMHFV) has been shown to provoke anabolic effects on the intact skeleton in both mice and humans. However, experimental studies revealed that, during bone fracture healing, the effect of whole-body vibration is profoundly influenced by the estrogen status. LMHFV significantly improved fracture healing in ovariectomized (OVX) mice being estrogen deficient, whereas bone regeneration was significantly reduced in non-OVX, estrogen-competent mice. Furthermore, estrogen receptors a (ER alpha) and beta (ER beta) were differentially expressed in the fracture callus after whole-body vibration, depending on the estrogen status. Based on these data, we hypothesized that ERs may mediate vibration-induced effects on fracture healing. To prove this hypothesis, we investigated the effects of LMHFV on bone healing in mice lacking ER alpha or ER beta. To study the influence of the ER ligand estrogen, both non-OVX and OVX mice were used. All mice received a femur osteotomy stabilized by an external fixator. Half of the mice were sham-operated or subjected to OVX 4 weeks before osteotomy. Half of each group received LMHFV with 03 g and 45 Hz for 20 min per day, 5 days per week. After 21 days, fracture healing was evaluated by biomechanical testing, mu CT analysis, histomorphometry and immunohistochemistry. Absence of ER alpha or ER beta did not affect fracture healing in sham-treated mice. Wildtype (Wt) and ER beta-knockout mice similarly displayed impaired bone regeneration after OVX, whereas ER alpha-knockout mice did not. Confirming previous data, in WT mice, LMHFV negatively affected bone repair in non-OVX mice, whereas OVX-induced compromised healing was significantly improved by vibration. In contrast, vibrated ER alpha-knockout mice did not display significant differences in fracture healing compared to non-vibrated animals, both in non-OVX and OVX mice. Fracture healing in ER beta-knockout mice was similarly affected by LMHFV as in WT mice. These results suggest that ER alpha-signaling may be crucial for vibration-induced effects on fracture healing, whereas ER beta-signaling may play a minor role. (C) 2018 Elsevier Inc. All rights reserved.
BACKGROUND CONTEXT: The range of motion is a well-accepted parameter for the assessment and evaluation of cervical motion. However, more qualitative data of the kinematics of the cervical spine are needed for the development and success of cervical disc arthroplasty. PURPOSE: The aim of this study was to provide basic information about helical axes of human cervical spine under in vitro conditions. Furthermore, it should clarify whether the three-dimensional helical axes of cervical motion gained from in vitro experiments are in agreement with those gained from in vivo experiments, and therefore to prove its reliability. STUDY DESIGN/SETTING: An in vitro test with pure moments and mono-segmental specimens was designed to investigate and compare the helical axes of the cervical spine. METHODS: Six human cadaveric specimens (three male and three female) with an average age of 47.5 years (range: 34-58 years) were carefully selected. Each specimen was divided into three motion segments: C2-C3, C4-C5, and C6-C7. We performed 3.5 full cycles of rotation about all axes, flexion-extension, lateral bending, and axial rotation, by applying pure moments of 1.5 Nm without any preload. Following the in vitro tests, the three-dimensional helical axes were calculated and projected into the x-ray images. RESULTS: Rotation analysis of all three directions revealed similar results for all six specimens. All calculated helical axes were similar to the published in vivo data. Furthermore, the instantaneous centers of rotation were in agreement with in vivo data. CONCLUSIONS: The data gained from this study verify cervical kinematics during in vitro testing using pure moments. It can be assumed that other soft tissue such as muscles are not necessarily needed to simulate cervical kinematics in vitro. (C) 2017 Elsevier Inc. All rights reserved.
To offer a functionality that could not be found in traditional rigid robots, compliant actuators are in development worldwide for a variety of applications and especially for human–robot interaction. Pneumatic bending actuators are a special kind of such actuators. Due to the absence of fixed mechanical axes and their soft behavior, these actuators generally possess a polycentric motion ability. This can be very useful to provide an implicit self-alignment to human joint axes in exoskeleton-like rehabilitation devices. As a possible realization, a novel bending actuator (BA) was developed using patented pneumatic skewed rotary elastic chambers (sREC). To analyze the actuator self-alignment properties, knowledge about the motion of this bending actuator type, the so-called skewed rotary elastic chambers bending actuator (sRECBA), is of high interest and this paper presents experimental and simulation-based kinematic investigations. First, to describe actuator motion, the finite helical axes (FHA) of basic actuator elements are determined using a three-dimensional (3D) camera system. Afterwards, a simplified two-dimensional (2D) kinematic simulation model based on a four-bar linkage was developed and the motion was compared to the experimental data by calculating the instantaneous center of rotation (ICR). The equivalent kinematic model of the sRECBA was realized using a series of four-bar linkages and the resulting ICR was analyzed in simulation. Finally, the FHA of the sRECBA were determined and analyzed for three different specific motions. The results show that the actuator’s FHA adapt to different motions performed and it can be assumed that implicit self-alignment to the polycentric motion of the human joint axis will be provided.
The human knee is one of the most investigated joints in the human body. Various test setups exist to measure and analyse knee kinematics in vitro which differ in a wide range of parameters. The purpose of this article is to find an answer to the question if the test setup influences the kinematic outcome of studies and to what extend the results can be compared. To answer this question, we compared the tibial rotation as a function of flexion angle presented in 19 published studies. Raw data was extracted via image segmentation from the graphs depicted in these publications and the differences between the publications was analysed. Additionally, all test setups were compared regarding four aspects: method for angle calculation, system for data acquisition, loading condition and testing rig design. The resulting correlation matrix shows the influence of the test setup on the study outcome. Our results indicate that each study needs to collect its own reference data. Finally, we provide a mean internal rotation as a function of flexion angle based on more than 140 specimens tested in 14 different studies.
This paper presents an approach for the tracking of limb movements using orientation information acquired from Inertial Measurement Units (IMUs) and optical information from a Kinect sensor. A new algorithm that uses a Kalman filter to fuse the Kinect and IMU data is presented. By fusing optical and orientation information we are able to track the movement of limb joints precisely, and almost drift-free. First, the IMU data is processed using the gradient descent algorithm proposed in (Madgwick et al., 2011) which calculates the orientation information of the IMU using acceleration and velocity data. Measurements made with IMUs tend to drift over time, so in a second stage we compensate for the drift using absolute position information obtained from a Microsoft Kinect sensor. The fusion of sensor data also allows to compensate for faulty or missing measurements. We have carried out some initial experiments on arm tracking. The first results show that our technique for data fusion has the potential to be used to record common medical exercises for clinical movement analysis.
In this paper we present an application for the analysis and characterisation of gait motion. Using motion data from Inertial Measurement Units (IMUs), seven relevant parameters are measured that extensively charaterize the gait of individuals. Our application uses raw and processed IMU data, where the processed data is the result of filtering the IMU data with a Magdwick filter. The filtered data offers orientation information and is relatively drift free. The IMU data is used to train a three layer neural network that can then extract individual footsteps from an IMU dataset. Results with different test persons show that our application can successfully characterize gait motion on an individual basis and can serve for the clinical assesment and evaluation of abnormal or pathological gait.