A new method to segment MR volumes has been developed. The method matches elastically a 3D deformable prior model, describing the structures of interest, to the MR volume of a patient. The deformation is done using a deformation grid. Oriented distance maps are utilized to guide the deformation process. Two alternative restrictions are used to preserve the geometrical prior knowledge of the model. The method is applied to extract the body, the lungs and the heart. The segmentation is needed to build individualized boundary element models for bioelectromagnetic inverse problem. The method is fast, automatic and accurate. Good results have been achieved for four MR volumes tested so far.
BACKGROUND:We evaluated the capability of multichannel magnetocardiography (MCG) to detect healed myocardial infarction (MI).METHODS:Multichannel MCG over frontal chest was recorded at rest in 21 patients with healed MI, detected by cine- and contrast-enhanced magnetic resonance imaging, and in 26 healthy controls. Of the 21 MI patients, 11 had non-Q wave and 10 Q wave MIs. QRS, ST-segment, T wave and ST-T wave integrals, ST-segment and T wave amplitudes, and QRS and ST-T wave magnetic field map orientations were measured.RESULTS:The MCG repolarization indexes, such as ST segment and ST-T wave integrals, separated the MI group from the controls (ST-T wave integral -1.4 +/- 5.3 vs 1.5 +/- 4.7 pTs, P = 0.034). The abnormalities were more distinct in the Q wave-MI than in the non-Q wave MI subgroup. In the latter, however, a trend similar to the Q wave MI group was found. The relation of QRS area to ST segment and T wave integral improved the detection of healed MIs compared to the ST-T wave indexes alone (QRS-ST-T discordance 14 +/- 10 vs 5.0 +/- 7.1 pTs, P = 0.003). When comparing the MI group to the controls, the orientation of the magnetic field maps differed in the ST-T wave maps (163 +/- 119 degrees vs 58 +/- 17 degrees, P < 0.001) but not in the QRS maps (111 +/- 95 degrees vs 106 +/-93 degrees, P = 0.646).CONCLUSIONS:The MCG repolarization variables can detect healed MI. These ST-T wave abnormalities are more pronounced in patients with Q wave MI than in patients with non-Q wave MIs. Relating the signals of depolarization and repolarization phases improves the detection of healed MI. Repolarization abnormalities are common in healed MI and thus should not always be interpreted as present ongoing ischemia.
The quality of phase and amplitude data from two medical optical tomography systems were compared. The two systems are a 32-channel time-domain system developed at University College London (UCL) and a 16-channel frequency-domain system developed at Helsinki University of Technology (HUT). Difference data measured from an inhomogeneous and a homogeneous phantom were compared with a finite-element method (diffusion equation) and images of scattering and absorption were reconstructed based on it. The measurements were performed at measurement times between 1 and 30 s per source. The mean rms errors in the data measured by the HUT system were 3.4% for amplitude and 0.51 deg for phase, while the corresponding values for the UCL data were 6.0% and 0.46 deg, respectively. The reproducibility of the data measured with the two systems was tested with a measurement time of 5 s per source. It was 0.4% in amplitude for the HUT system and 4% for the UCL system, and 0.08 deg in phase for both systems. The image quality of the reconstructions from the data measured with the two systems were compared with several quantitative criteria. In general a higher contrast was observed in the images calculated from the HUT data.
Background: Prolonged QRS duration (QRSd) is associated with increased mortality after myocardial infarction (MI). Only little data exist about its predictive ability and relationships to clinical variables in the present era of active treatment of myocardial ischemia and cardiac dysfunction. We investigated whether QRSd in high-resolution methods and standard ECG predict arrhythmic events and cardiac death in post-infarction patients with cardiac dysfunction and how it relates to clinical variables, with a special emphasis on history of previous MI.Methods and Results: Patients (n = 158) with acute MI and cardiac dysfunction had magnetocardiography (MCG), signal-averaged ECG (SAECG), and ECG registered at discharge. Patients with a previous MI had significantly longer QRSd although their left ventricular function was almost similarly impaired. During the mean follow-up of 50 +/- 15 (range 1-72) months, 32 patients died and 17 (53%) of the deaths were classified as cardiac. Eighteen patients had an arrhythmic event. QRSd >121 ms in MCG and >114 ms in SAECG were significant predictors of arrhythmic events and cardiac death, whereas QRSd in ECG predicted only cardiac death. In multivariate analysis, QRSd in MCG (hazard ratio (HR) = 3.6, P = 0.007) and SAECG (HR = 4.6, P = 0.016) predicted only arrhythmic events, whereas QRSd in ECG was an independent predictor of cardiac death.Conclusions: Prolonged QRSd in MCG and SAECG are powerful indicators of the arrhythmia substrate in post-infarction patients with cardiac dysfunction, whereas prolonged QRSd in standard ECG associates with increased risk of cardiac death.
Background: Although magnetocardiographic (MCG) parameters describing fragmented and slow conduction can identify patients with post-infarction ventricular arrhythmias, prospective data is lacking.
Recent studies reported differential information in human magnetocardiogram and in electrocardiogram. Vortex currents have been discussed as a possible source of this divergence. With the help of physical phantom experiments, we quantified the influence of active vortex currents on the strength of electric and magnetic signals, and we tested the ability of standard source localization algorithms to reconstruct vortex currents. The active vortex currents were modeled by a set of twelve single current dipoles arranged in a circle and mounted inside a phantom that resembles a human torso. Magnetic and electric data were recorded simultaneously while the dipoles were switched on stepwise one after the other. The magnetic signal strength increased continuously for an increasing number of dipoles switched on. The electric signal strength increased up to a semicircle and decreased thereafter. Source reconstruction with unconstrained focal source models performed well for a single dipole only (less than 3-mm localization error). Minimum norm source reconstruction yielded reasonable results only for a few of the dipole configurations. In conclusion active vortex currents might explain, at least in part, the difference between magnetically and electrically acquired data, but improved source models are required for their reconstruction.
Diffuse optical imaging is a functional medical imaging modality which takes advantage of the relatively low attenuation of near-infrared light to probe the internal optical properties of tissue. The optical properties are affected by parameters related to physiology such as the concentrations of oxy- and deoxyhemoglobin. Instrumentation that is used for optical imaging is generally able to measure changes in the attenuation of light at several wavelengths, and in the case of time- and frequency-domain instrumentation, the time-of-flight of the photons in tissue. Light propagation in tissue is generally dominated by scattering. Models for photon transport in tissue are generally based on either stochastic approaches or approximations derived from the radiative transfer equation. If a numerical forward model which describes the physical situation with sufficient accuracy exists, inversion methods may be used to determine the internal optical properties based on boundary measurements. Optical imaging has applications in, e.g., functional brain imaging, breast cancer detection, and muscle imaging. It has the important advantages of transportable instrumentation, relatively high tolerance for external electromagnetic interference, non-invasiveness, and applicability for neonatal studies. The methods are not yet in clinical use, and further research is needed to improve the reliability of the experimental techniques, and the accuracy of the models used.
In the context of motion estimation of the heart and thoracic structures from tomographic imaging, we investigated two free form deformations (FFD) based non linear registration methods as motion estimators. Standard and cylindrical FFD (CFFD) methods are evaluated in 2D, both on simulated and in vivo cardiac and thoracic images. Results tend to show that CFFD based method achieves the same accuracy with less parameters. However, the fast convergence of this model is hamped by a higher computing time with a straightforward implantation.
Background: Prolonged QRS durations (QRSd) in high resolution magnetocardiography (MCG) and signal averaged ECG (SAECG) predict arrhythmia risk after myocardial infarction (MI). We examined how history of previous MI influences QRSd and its predictive value after acute MI.
Cerebral blood flow and oxygenation changes during different levels of hypo- and hypercapnia were successfully monitored on the human forehead using a multi-channel frequency-domain near-infrared spectroscopy. Optical signals correlate well with simultaneously recorded gas measurements.
BACKGROUND:We studied the ability of different time segments of the depolarization wave recorded with body surface potential mapping (BSPM) to detect and localize myocardial infarction (MI).METHODS:BSPM was recorded in 24 patients with remote MI and in 24 healthy controls. Cine and contrast-enhanced magnetic resonance imaging (MRI) was used as a reference method. Patients were grouped according to anatomical location of their MI. The QRS complex was divided into six temporally equal segments, for which time integrals were calculated.RESULTS:The time segments of the QRS complex showed different MI detection capability depending on MI location. For anterior infarction the second segment of the QRS complex was the best in MI detection and the optimal area was on the right inferior quadrant of the thorax (time integral average -1.5 +/- 1.8 mVms patients, 1.0 +/- 1.6 mVms controls, P = 0.002). For lateral infarction the first segment of the QRS complex performed best and the optimal area for MI detection was the left fourth intercostal area (time integral average 1.8 +/- 1.0 mVms patients, 0.7 +/- 0.5 mVms controls, P = 0.024). For inferior and posterior MI the mid-phases of the QRS complex were the best and the optimal area was the mid-inferior area of the thorax (time integral average -6.2 +/- 8.3 mVms patients, 3.3 +/- 4.3 mVms controls, P = 0.002; -9.1 +/- 6.1 mVms patients, 0.6 +/- 7.1 mVms controls, P = 0.001, respectively).CONCLUSIONS:Time segment analysis of the depolarization wave offers potential for improving the detection and localization of healed MI.
In this paper an evaluation and a comparison of surface and image intensity based (mutual information, normalized mutual information and correlation ratio) rigid registration methods for cardiac magnetic resonance and positron emission tomography images are presented. In both types of rigid image registration methods, PET transmission image was used as a linking mediator to register corresponding PET emission image to MR image coordinates. Also direct rigid registration of PET emission image to MR image coordinates was tested. Methods were evaluated with simulated and ten patient MR-PET images and with three optimization methods. Results indicated that NMI and CR methods with simplex optimization provided the most robust and accurate results.
An instrument and matching calibration method were developed for the measurement of phase with minimal systematic errors over a wide range of intensities. The instrument, method and factors affecting the quality of data are described.
KORHONEN, P., et al. : Relation of Magnetocardiographic Arrhythmia Risk Parameters to Delayed Ventricular Conduction in Postinfarction Ventricular Tachycardia. Time‐domain late field and intra‐QRS fragmentation parameters in magnetocardiography (MCG) identify patients prone to VT after myocardial infarction. This study investigated if they are related to slow ventricular conduction and affected by arrhythmia surgery. Twenty‐two patients with old myocardial infarction undergoing map‐guided subendocardial resection to treat sustained VT were included. Bipolar electrograms were recorded during operation using an epicardial jacket and endocardial balloon electrode array. The time from the QRS onset to the end of local ventricular excitation in each electrogram was measured during sinus rhythm. Multichannel MCG was recorded before and after operation and filtered QRS duration (QRSd), root mean square amplitude of the magnetic field strength during the last 40 ms of the QRS complex (RMS 40 ), duration of the low amplitude signal < 300 fT (LAS 300 ), fragmentation index M (M), and fragmentation score S (S) were determined. All patients had one or two VT foci localized and resected. MCG parameters correlated with time to the latest end of ventricular excitation; r = 0.45 for QRSd ( P = 0.035 ), r = 0.64 for M ( P = 0.001 ), and r = 0.73 for S ( P < 0.001 ). The correlations were even better in patients with anterior infarction ( e.g., r = 0.87 for QRSd, P < 0.001; r = 0.91 for M, P < 0.001 ). The operation reduced the abnormalities in MCG parameters and 20 of the 21 patients tested postoperatively became noninducible. MCG parameters indicating postinfarction arrhythmia propensity are related to delayed ventricular conduction. Abolition of the arrhythmia substrate reverses the abnormality of these parameters.
In this paper, an approach for the assessment of 3-D functional maps of the heart is proposed. It relies on the model-based coregistration of MR anatomical and PET metabolic images and the extraction of an individualized anatomical heart model from MR images. This results in a 3-D geometrical model of the heart for which functional parameters such as FDG uptake can be attributed and visualized.