Existing mass spectrometric assays used for sensitive and specific measurements of target proteins across multiple samples, such as selected/multiple reaction monitoring (SRM/MRM) or parallel reaction monitoring (PRM), are peptide-based methods for bottom-up proteomics. Here, we describe an approach based on the principle of PRM for the measurement of intact proteoforms by targeted top-down proteomics, termed proteoform reaction monitoring (PfRM). We explore the ability of our method to circumvent traditional limitations of top-down proteomics, such as sensitivity and reproducibility. We also introduce a new software program, Proteoform Finder (part of ProSight Native), specifically designed for the easy analysis of PfRM data. PfRM was initially benchmarked by quantifying three standard proteins. The linearity of the assay was shown over almost 3 orders of magnitude in the femtomole range, with limits of detection and quantification in the low femtomolar range. We later applied our multiplexed PfRM assay to complex samples to quantify biomarker candidates in peripheral blood mononuclear cells (PBMCs) from liver-transplanted patients, suggesting their possible translational applications. These results demonstrate that PfRM has the potential to contribute to the accurate quantification of protein biomarkers for diagnostic purposes and to improve our understanding of disease etiology at the proteoform level.
Theoretically, the gas-phase interrogation of whole proteoforms via mass spectrometry, known as top-down proteomics, bypasses the protein inference problem that afflicts peptide-centric proteomic approaches. Despite this obvious advantage, the application of top-down proteomics remains rare, mainly due to limited throughput and difficulty of analyzing proteins >30 kDa. Here we will discuss some of the problems encountered during the characterization of large proteoforms, and guided by a combination of theoretical background and experimental evidence we will describe some innovative data acquisition strategies and novel mass spectrometry technologies that can at least partially overcome such limitations.
Human biology is tightly linked to proteins, yet most measurements do not precisely determine alternatively spliced sequences or posttranslational modifications. Here, we present the primary structures of ~30,000 unique proteoforms, nearly 10 times more than in previous studies, expressed from 1690 human genes across 21 cell types and plasma from human blood and bone marrow. The results, compiled in the Blood Proteoform Atlas (BPA), indicate that proteoforms better describe protein-level biology and are more specific indicators of differentiation than their corresponding proteins, which are more broadly expressed across cell types. We demonstrate the potential for clinical application, by interrogating the BPA in the context of liver transplantation and identifying cell and proteoform signatures that distinguish normal graft function from acute rejection and other causes of graft dysfunction.
The development and application of electron-based ion dissociation methods as a counterpart to vibrational excitation dissociation techniques has expanded the capabilities of biomolecular mass spectrometry. Electron capture dissociation and electron transfer dissociation are powerful tandem mass spectrometry tools for sequencing multiply protonated peptide and protein cations resulting from ionization under denaturing conditions. We will discuss the basics of these fragmentation methods as applied to targeted and global proteome analyses, for bottom-up techniques that analyze peptides as well as top-down techniques that interrogate intact proteins. The unique features of electron capture/transfer dissociation that differentiate it from more common fragmentation methods will be discussed, as well as the challenges faced by researchers looking to exploit these techniques for proteomics endeavors. A growing practice in the field of biomolecular mass spectrometry is combining tandem mass spectrometry approaches to increase the depth and breadth of analyses. Therefore, we will discuss efforts to develop supplemental activation workflows that combine electron-based dissociation methods with “slow heating” activation techniques. One of the value propositions of electron-based dissociation methods is the preservation of labile post-translational modifications. Therefore, we conclude this chapter by digging deeper into the characterization and localization of chemical modifications to a polypeptide chain.
Top-down proteomics studies intact proteoform mixtures and offers important advantages over more common bottom-up proteomics technologies, as it avoids the protein inference problem. However, achieving complete molecular characterization of investigated proteoforms using existing technologies remains a fundamental challenge for top-down proteomics. Here, we benchmark the performance of ultraviolet photodissociation (UVPD) using 213 nm photons generated by a solid-state laser applied to the study of intact proteoforms from three organisms. Notably, the described UVPD setup applies multiple laser pulses to induce ion dissociation, and this feature can be used to optimize the fragmentation outcome based on the molecular weight of the analyzed biomolecule. When applied to complex proteoform mixtures in high-throughput top-down proteomics, 213 nm UVPD demonstrated a high degree of complementarity with the most employed fragmentation method in proteomics studies, higher-energy collisional dissociation (HCD). UVPD at 213 nm offered higher average proteoform sequence coverage and degree of proteoform characterization (including localization of post-translational modifications) than HCD. However, previous studies have shown limitations in applying database search strategies developed for HCD fragmentation to UVPD spectra which contains up to nine fragment ion types. We therefore performed an analysis of the different UVPD product ion type frequencies. From these data, we developed an ad hoc fragment matching strategy and determined the influence of each possible ion type on search outcomes. By paring down the number of ion types considered in high-throughput UVPD searches from all types down to the four most abundant, we were ultimately able to achieve deeper proteome characterization with UVPD. Lastly, our detailed product ion analysis also revealed UVPD cleavage propensities and determined the presence of a product ion produced specifically by 213 nm photons. All together, these observations could be used to better elucidate UVPD dissociation mechanisms and improve the utility of the technique for proteomic applications.
The Consortium for Top-Down Proteomics (www.topdownproteomics.org) launched the present study to assess the current state of top-down mass spectrometry (TD MS) and middle-down mass spectrometry (MD MS) for characterizing monoclonal antibody (mAb) primary structures, including their modifications. To meet the needs of the rapidly growing therapeutic antibody market, it is important to develop analytical strategies to characterize the heterogeneity of a therapeutic product's primary structure accurately and reproducibly. The major objective of the present study is to determine whether current TD/MD MS technologies and protocols can add value to the more commonly employed bottom-up (BU) approaches with regard to confirming protein integrity, sequencing variable domains, avoiding artifacts, and revealing modifications and their locations. We also aim to gather information on the common TD/MD MS methods and practices in the field. A panel of three mAbs was selected and centrally provided to 20 laboratories worldwide for the analysis: Sigma mAb standard (SiLuLite), NIST mAb standard, and the therapeutic mAb Herceptin (trastuzumab). Various MS instrument platforms and ion dissociation techniques were employed. The present study confirms that TD/MD MS tools are available in laboratories worldwide and provide complementary information to the BU approach that can be crucial for comprehensive mAb characterization. The current limitations, as well as possible solutions to overcome them, are also outlined. A primary limitation revealed by the results of the present study is that the expert knowledge in both experiment and data analysis is indispensable to practice TD/MD MS.
The suitability of a liquid chromatography–high-resolution mass spectrometry (LC–HRMS) method for monitoring peptide drug product quality is demonstrated on three case studies using the peptide drugs salmon calcitonin, bivalirudin and exenatide as model systems. LC–HRMS methods were able to provide qualitative information by characterizing the peptide structure and sequence and identifying peptide-related impurities. In addition, LC–HRMS methods can be used to obtain quantitative results with high selectivity, sensitivity, accuracy and precision and suitable linearity. Furthermore, LC–HRMS methods are advantageous because they have the ability to separate and detect low-level impurities where traditional high-performance liquid chromatography–UV detection (HPLC–UV) methods can lack the necessary specificity and sensitivity. Overall, LC–HRMS is an approach that can be used as part of the analytical framework to ensure proper quality control of peptide drug products including the assessment of peptide-related impurities.
Top-down proteomics (TDP) by mass spectrometry (MS) is a technique by which intact proteins are analyzed. It has become increasingly popDesalting and concentrating GELFrEEular in translational research because of the value of characterizing distinct proteoforms of intact proteins. Compared to bottom-up proteomics (BUP) strategies, which measure digested peptide mixtures, TDP provides highly specific molecular information that avoids the bioinformatic challenge of protein inference. However, the technique has been difficult to implement widely because of inherent limitations of existing sample preparation methods and instrumentation. Recent improvements in proteoform pre-fractionation and the availability of high-resolution benchtop mass spectrometers have made it possible to use high-throughput TDP for the analysis of complex clinical samples. Here, we provide a comprehensive protocol for analysis of a common sample type in translational research: human peripheral blood mononuclear cells (PBMCs). The pipeline comprises multiple workflows that can be treated as modular by the reader and used for various applications. First, sample collection and cell preservation are described for two clinical biorepository storage schemes. Cell lysis and proteoform pre-fractionation by gel-eluted liquid fractionation entrapment electrophoresis are then described. Importantly, instrument setup and liquid chromatography-tandem MS are described for TDP analyses, which rely on high-resolution Fourier-transform MS. Finally, data processing and analysis are described using two different, application-dependent software tools: ProSight Lite for targeted analyses of one or a few proteoforms and TDPortal for high-throughput TDP in discovery mode. For a single sample, the minimum completion time of the entire experiment is 72 h.
Biomarker profiles of acute rejection in liver transplant recipients could enhance the diagnosis and management of recipients. Our aim was to identify diagnostic proteoform signatures of acute rejection in circulating immune cells, using an emergent "top-down" proteomics methodology. We prepared differentially processed and cryopreserved cell lysates from 26 nonviral liver transplant recipients by molecular weight-based fractionation and analyzed them by mass spectrometry of whole proteins in three steps: (i) Nanocapillary liquid chromatography coupled with high-resolution tandem mass spectrometry; (ii) database searching to identify and characterize intact proteoforms; (iii) data processing through a hierarchical linear model matching the study design to quantify proteoform fold changes in patients with rejection versus normal liver function versus acute dysfunction without rejection. Differentially expressed proteoforms were seen in patients with rejection versus normal and nonspecific controls, most evidently in the cell preparations stored in traditional serum-rich media. Mapping analysis of these proteins back to genes through gene ontology and pathway analysis tools revealed multiple signaling pathways, including inflammation mediated by cytokines and chemokines. Larger studies are needed to validate these novel rejection signatures and test their predictive value for use in clinical management.
Mass spectrometry (MS) is widely recognized as a powerful analytical tool for molecular research. MS is used by researchers around the globe to identify, quantify, and characterize biomolecules like proteins from any number of biological conditions or sample types. As instrumentation has advanced, and with the coupling of liquid chromatography (LC) for high‐throughput LC‐MS/MS, a proteomics experiment measuring hundreds to thousands of proteins/protein groups is now commonplace. While expert practitioners who best understand the operation of LC‐MS systems tend to have strong backgrounds in physics and engineering, consumers of proteomics data and technology are not exposed to the physio‐chemical principles underlying the information they seek. Since articles and reviews tend not to focus on bridging this divide, our goal here is to span this gap and translate MS ion physics into language intuitive to the general reader active in basic or applied biomedical research. Here, we visually describe what happens to ions as they enter and move around inside a mass spectrometer. We describe basic MS principles, including electric current, ion optics, ion traps, quadrupole mass filters, and Orbitrap FT‐analyzers.
Biomarker discovery in the translational research has heavily relied on labeled and label-free quantitative bottom-up proteomics. Here, we describe a new approach to biomarker studies that utilizes high throughput top-down proteomics and is the first to offer whole protein characterization and relative quantitation within the same experiment. Using yeast as a model, we report procedures for a label-free approach to quantify the relative abundance of intact proteins ranging from 0 to 30 kDa in two different states. In this chapter, we describe the integrated methodology for the large-scale profiling and quantitation of the intact proteome by liquid chromatography-mass spectrometry (LC-MS) without the need for metabolic or chemical labeling. This recent advance for quantitative top-down proteomics is best implemented with a robust and highly controlled sample preparation workflow before data acquisition on a high-resolution mass spectrometer, and the application of a hierarchical linear statistical model to account for the multiple levels of variance contained in quantitative proteomic comparisons of samples for basic and clinical research.
From a molecular perspective, enactors of function in biology are intact proteins that can be variably modified at the genetic, transcriptional, or post-translational level. Over the past 30 years, mass spectrometry (MS) has become a powerful method for the analysis of proteomes. Prevailing bottom-up proteomics operates at the level of the peptide, leading to issues with protein inference, connectivity, and incomplete sequence/modification information. Top-down proteomics (TDP), alternatively, applies MS at the proteoform level to analyze intact proteins with diverse sources of intramolecular complexity preserved during analysis. Fortunately, advances in prefractionation workflows, MS instrumentation, and dissociation methods for whole-protein ions have helped TDP emerge as an accessible and potentially disruptive modality with increasingly translational value. In this review, we discuss technical and conceptual advances in TDP, along with the growing power of proteoform-resolved measurements in clinical and translational research.
Recent studies utilizing transcriptomics, metabolomics, and bottom up proteomics have identified molecular signatures of kidney allograft pathology. Although these results make significant progress toward non-invasive differential diagnostics of dysfunction of a transplanted kidney, they provide little information on the intact, often modified, protein molecules present during progression of this pathology. Because intact proteins underpin diverse biological processes, measuring the relative abundance of their modified forms promises to advance mechanistic understanding, and might provide a new class of biomarker candidates. Here, we used top down proteomics to inventory the modified forms of whole proteins in peripheral blood mononuclear cells (PBMCs) taken at the time of kidney biopsy for 40 kidney allograft recipients either with healthy transplants or those suffering acute rejection. Supported by gas-phase fragmentation of whole protein ions during tandem mass spectrometry, we identified 344 proteins mapping to 2905 distinct molecular forms (proteoforms). Using an initial implementation of a label-free approach to quantitative top down proteomics, we obtained evidence suggesting relative abundance changes in 111 proteoforms between the two patient groups. Collectively, our work is the first to catalog intact protein molecules in PBMCs and suggests differentially abundant proteoforms for further analysis.
Enabling the implementation of top down proteomic techniques within clinical workflows requires a dramatic increase in sensitivity. It has been previously demonstrated that electrospray ionization (ESI) becomes more efficient with decreasing volumetric flow rates at the emitter. Therefore, narrow inner diameter (I.D.) columns used in front-end chromatographic separations yield increased sensitivity. However, the smaller cross-sectional area of a narrow I.D. column places a larger fraction of the eluent in fluid communication with the electrode within the high voltage union that facilitates electrospray ionization (ESI), leading to increased oxidation of solution-phase proteins. Oxidation of proteins alters their chemical state of the protein, complicates data analysis, and reduces the depth of proteome coverage attained in a typical top-down proteomics experiment. Excessive protein oxidation results in poor deconvolution and exact mass calculations from MS1 spectra, interferes with peak isolation for MS/MS fragmentation, and effectively reduces sensitivity by splitting ion current. All of these factors deteriorate top down mass spectral data quality, an effect that becomes more pronounced as column diameter decreases. Artificial protein oxidation can also mislead investigations of in vivo protein oxidation. All of these effects are accentuated in comparison to bottom up proteomics due to the increased probability of having oxidizable residues within a particular species with increasing mass. Herein, we describe a configuration (which we term “Low Protein Oxidation (LPOx)”) for proteomics experiments created by re-arranging liquid chromatography (LC) plumbing and present its application to artificial protein oxidation and show a marked improvement in detection sensitivity. Using a standard mixture of five intact proteins, we demonstrate that the LPOx configuration reduces protein oxidation up to 90% using 50 μm I.D. columns when compared to a conventional LC plumbing configuration with 50 μm I.D. column. As a proof-of-concept study, at least 11 distinct proteoforms of serum Apolipoprotein A1 were detected with the LPOx configuration. This innovative LC configuration can be applied to the top down identification and characterization of proteoforms obscured by abundant artificial protein oxidation at low flowrates, all while using reduced amounts of valuable protein samples.
We have recently described a 96-well plate format assay for visually detecting oversulfated chondroitin sulfate A (OSCS) in heparin that uses a water soluble cationic polythiophene polymer (3-(2-(N-(N′-methylimidazole))ethoxy)-4-methylthiophene (LPTP)) and heparinase digestion. Because dermatan sulfate (DS, a.k.a. chondroitin sulfate B (CSB)) and, to a lesser degree, chondroitin sulfate A (CSA) are the most common native impurities of heparin active pharmaceutical ingredients (APIs) we adapted the previously established micro-plate assay for the visual detection of DS and CSA in heparin sodium. We describe a naked-eye detection test of these common heparin impurities with sensitivity appropriate for the United States Pharmacopeia (USP) 1% percent galactosamine in total hexosamine specification. For example, the test detects DS ≥ 1.0% w/w visually and 0.5% using a plate reader, or CSA ≥ 1.0 to 2.0% w/w visually and at ≥1.0% with a plate reader. In contrast to the test developed for oversulfated glycosaminoglycans such as OSCS, the LPTP–chondroitinase test developed here utilizes chondroitinase ABC instead of heparinases and requires a centrifugal filtration step to remove un-digested heparin. The test takes advantage of the sensitivity of the LPTP chemosensor to low molecular weight glycosaminoglycan (GAG) fragments formed by digesting DS or CSA. Importantly, the LPTP–chondroitinase method detects DS and CSA in heparin sodium in a format potentially amenable to high throughput screening.
The existence of interactions between sequential enzymes of metabolic pathways has been explored extensively throughout the field of biochemistry. These closely coupled pathways, termed metabolons, have been demonstrated to induce substrate channeling that results in increased efficiency by enhancing local substrate concentrations, protecting liable intermediates, and limiting distance between enzyme active sites. This phenomenon may have direct implication in the advancement of multi‐enzyme enzymatic biofuel cells through the use of super‐complex formations as bioanode catalysts. This will result in an efficient means of a more complete oxidation of a fuel, while optimizing the flux of the system through the recreation of a phenomenon that is conserved throughout biology.
Living cells oxidize a wide variety of fuels by employing enzymes as catalysts for energy conversion. It has been shown that many of these cellular metabolic enzymes exist in sequential and proximal organization within living organisms. This organization, called a metabolon, results in channeling of substrates between enzymes. Biofuel cell researchers have studied multienzyme systems, but they have not investigated the need for proximal three-dimension organization in efficient energy conversion. This work outlines the use of a Krebs cycle metabolon catalyst obtained through the in situ cross-linking of protein within the mitochondria of Saccharomyces cervisea. This cross-linking maintains the integrity of the sequential complexation that exists naturally in the intact biological system. These complexes channel substrate through the enzyme cascade and improve mass transport, thus increasing the current and power density of pyruvate/air enzymatic biofuel cells.