Background: Although 95% of fish-allergic patients are sensitized to the major fish allergen parvalbumin, clinical reactions to different fish species vary considerably in symptoms, intensity and frequency in allergic subjects. This study aimed at the quantification of parvalbumin levels in salmon, trout, cod, carp, mackerel, herring, redfish and tuna. Methods: Fish muscle extracts were separated by SDS-PAGE and parvalbumin content was estimated by densitometric band quantification. Individual antisera were raised in BALB/c mice against parvalbumins purified from seven fish species. Parvalbumin content was quantified in fish (raw/processed) and skin prick test (SPT) solutions by ELISA using the corresponding anti-serum for detection and the purified parvalbumins as standards. Results: Using SDS-PAGE scanning, parvalbumin contents were <0.5 mg per gram tissue for mackerel, 0.5–2 mg for salmon and trout, and >2 mg for cod, carp, redfish and herring. Using ELISA, parvalbumin content ranged from <0.05 mg for tuna, 0.3–0.7 mg for mackerel, 1–2.5 mg for salmon, trout and cod to >2.5 mg per gram raw muscle for carp, herring and redfish. The parvalbumin content of processed samples (cooked/commercial) was 20–60% lower. Allergen content in SPT samples ranged from 20 to 70 µg parvalbumin/ml of extract. No parvalbumin was found in tuna SPT solution. Conclusion: The parvalbumin content of most commonly consumed fish species varies considerably. Differences range from severalfold to one hundredfold. This has to be taken into account when designing food challenge tests and advising fish-allergic patients.
Background: Stent implantation is the predominant therapy for non-surgical myocardial revascularization in patients with coronary artery disease. However, despite substantial advances in multidetector computed tomography (MDCT) coronary imaging, a reliable detection of coronary in-stent restenosis is currently not possible. Purpose: To examine the ability of 64-detector-row CT to detect and to grade in-stent stenosis in coronary stents using a newly developed ex-vivo vessel phantom with a realistic CT density pattern, artificial stenosis, and a thorax phantom. Material and Methods: Four different stents (Liberté and Lunar ROX, Boston Scientific; Driver, Medtronic; Multi-Link Vision, Guidant) were examined. The stents were placed on a polymer tube with a diameter of 2.5, 3.0, 3.5, or 4.0 mm. Different degrees of stenosis (0%, 30%, 50%, 70–80%) were created inside the tube. For quantitative analysis, attenuation values were measured in the non-stenotic vessel outside the stent, in the non-stenotic vessel inside the stent, and in the stenotic area inside the stent. The grade of stenosis was visually assessed by two observers. Results: All stents led to artificial reduction of attenuation, the least degree of which was found in the Liberté stent (11.3±10.2 HU) and the Multi-Link Vision stent (17.6±17.9 HU; P = 0.25). Overall, the non-stenotic vessel was correctly diagnosed in 55.5%, the low-grade stenosis in 58.3%, the intermediate stenosis in 63.8%, and the high-grade stenosis in 80.5%. In the 3.0-, 3.5-, and 4.0-mm vessels, in none of the cases was a non-stenotic or low-grade stenotic vessel misdiagnosed as intermediate or high-grade stenosis. The average deviation from the real grade of stenosis was 0.40 for the Liberté stent, 0.46 for the Lunar ROX stent, 0.45 for the Driver stent, and 0.58 for the Multi-Link Vision stent. Conclusion: Our ex-vivo data show that non-stenotic stents and low-grade in-stent stenosis can be reliably differentiated from intermediate and high-grade in-stent stenosis in vessels with a diameter of 3 to 4 mm. With regard to artifacts and the grading of stenoses, the Liberté stent was best suited for CT coronary angiography.
The accuracy of the conventional Transmission Line Method (TLM) which is used for measuring specific contact resistivity is sensitive to the sheet resistance of the contact metallisation and to variations in probe placement positions. Furthermore if end-resistance measurements are used to determine the modified sheet resistance (R(sk) under the contact pad these problems may be exacerbated. We propose an alternative TLM structure that avoids these difficulties. Both metallisation sheet resistance and modified sheet resistance are included in the model. The validity of this approach is verified by examining experimental results for AuGeNi contacts on n+ GaAs, using both the conventional and alternative TLM techniques and demonstrating improvements in accuracy and consistency.