The National Measurement Institute (NMI) is Australia's peak measurement body responsible for biological, chemical, legal and physical measurement and is currently administered within the Australian Government's Department of Industry, Innovation and Science.
Bees are threatened by multiple stressors, including environmental contaminants such as perfluorooctanesulfonate (PFOS). In this exposure-effect study, small whole colonies of the western honey bee (A. mellifera) (2500 individual bees) were exposed to sublethal PFOS concentrations (5 to 20 μg L-1 in sugar syrup) over a 25-day period using a purpose-built cage system. The PFOS was transferred to honey, accumulated in bee tissue, and was detected in feces at all exposure concentrations. At the sublethal exposures, adult bee colonies in all treatments appeared healthy, colonies were sustained, brood was produced, and resources were stored, but adverse life stage development and intergenerational effects were evident even at the lowest exposure concentration of 5 μg L-1. Analysis of bee heads indicated no oxidative damage based on protein carbonyl and malondialdehyde (MDA) biomarkers, but significant differential expression of some proteins important for bee health was observed in the 10 μg L-1 (proteins n = 2) and 20 μg L-1 (proteins n = 15) exposure treatments. This study provides the first confirmation that sublethal PFOS exposure may adversely influence the long-term viability of honey bee colonies and that PFOS will accumulate in exposed bees and transfer to honey, presenting a potential threat to food security and human health.
This paper presents a clean-up method to remove the Multiple Reaction Monitoring (MRM) isobaric interference from taurine conjugated bile acid isomers to the primary transition ion m/z = 499 > 80 for PFOS analysis in biological samples. Upon the identification of taurodeoxycholate (TDCA) isomers interference, the sample was evaporated to dryness under nitrogen, reconstituted with 1% formic acid in acetonitrile, then passed through an Agilent EMR-lip Solid-Phase-Extraction (SPE) cartridge. The eluent was concentrated and re-analysed. The method has been successfully applied in PFOS analysis of serum, liver, egg, shrimp, and fish samples with comparable values between two transition ions m/z = 499 > 80 & 99 and spike recoveries from 70% to 125%. Another interference to m/z = 499 > 80 in shrimp samples was investigated and tentatively speculated as taurine conjugate with unsaturated fatty acid. In addition, the method could remove the steroid sulfates interference to PFHxS transitions m/z = 399 > 80 and m/z = 399 > 99 in human serum samples. The Perfluoro-1-methylheptanesulfonate (P1MHpS), a branched PFOS isomer (br-PFOS), was identified to interfere with PFOS quantification in serum samples, causing either over- or under-estimation of PFOS values due to its response factors being 250% for the m/z = 499 > 99 transition and 5% for 499 > 80 transition. A calculation formula was proposed for quantification of P1MHpS and total PFOS values. About 20% of serum samples contained significant P1MHpS at 12-27% of total PFOS, indicating its high accumulation behaviour in human serum.
We report the development of a high-precision optical interferometer for the next-generation calculable cross-capacitor at the National Measurement Institute, Australia (NMIA). Dual-frequency locking is achieved using acousto-optic modulation, with carriers locked to TEM00 and TEM1 cavity mode resonances. Beat frequency measurements between TEM00 and TEM1 modes over an hour period yielded ( 118.20 +/- 0.24 ) MHz ( 2 sigma ), corresponding to the Gouy phase of ( 907 +/- 2 ) mrad ( 2 sigma ) and a phase caustic length correction of ( 76.77 +/- 0.16 ) nm ( 2 sigma ). The dual-mode locking stability of 110 kHz was well below the maximum 280 kHz uncertainty requirement for phase caustic correction. Interferometer alignment using an external reference cavity minimized the cosine error contribution to below 1 & times;10(-10) F/F relative uncertainty. The measurement results demonstrate the system is on track to achieve its targeted relative capacitance measurement uncertainty of 3 & times;10(-9 )F/F.
The utilisation of edible seafood processing waste could be beneficial for environmental, economic and health outcomes. We developed a method to rapidly enhance the vitamin D content of shelf-stable snacks made from salmon (Salmo salar) processing offcuts. Raw salmon skin, crispy salmon skin snacks and salmon jerky were treated with pulsed ultraviolet light, and vitamin D3, 25-hydroxyvitamin D3 (25(OH)D3), vitamin D2 and 25(OH)D2 concentrations were measured before and after treatment. Ultraviolet light treatment increased vitamin D3 in raw salmon skin and crispy salmon skin snacks by a mean (SD) of 53.6 (12.3) and 48.7 (1.8) mu g/100 g, respectively. Crispy salmon skin snacks and salmon jerky contained 1.1 (0.1) and 1.6 (0.02) g/100 g omega-3 long-chain polyunsaturated fatty acids, respectively. Pulsed ultraviolet light could be a commercially viable method for producing nutrient-dense, novel foods that can be made from seafood processing offcuts.