Tenaga Nasional Berhad (English: National Energy Limited, abbreviated as TNB; TENA, MYX: 5347), also known as Tenaga Nasional or simply Tenaga, is the Malaysian multinational electricity company and is the only electric utility company in Peninsular Malaysia and also the largest publicly-listed power company in Southeast Asia with MYR 99.03 billion worth of assets. It serves over 8.4 million customers throughout Peninsular Malaysia (except Sarawak)[a] and the East Malaysian state of Sabah through Sabah Electricity Sdn Bhd. TNB's core activities are in the generation, transmission and distribution of electricity. Other activities include repairing, testing and maintaining power plants, providing engineering, procurement and construction services for power plants related products, assembling and manufacturing high voltage switchgears, coal mining and trading. Operations are carried out in Malaysia, Mauritius, Pakistan, India and Indonesia.TNB is one of the 10 companies under Khazanah Nasional, Malaysian sovereign wealth fund and also one of the 13 Malaysian companies listed on the Forbes Global 2000 in 2018.TNB is ranked 16th globally in Brand Finance: Utilities 50 2021 Ranking and 226th globally in 2020 Bentley Infrastructure 500.
Research on waste electrical and electronic equipment (WEEE) management has persistent gaps in environmental, social, and economic aspects. This paper systematically analyzes emerging indicator information, contrasting implicit (less tangible) aspects, such as governance and socio-economic issues, with explicit (more tangible) aspects, including environmental and technical issues using the Multi-level Perspective (MLP) framework. This study aims to provide a comprehensive review of 62 articles related to e-waste in Malaysia, focusing exclusively on journal publications and proceedings from 2010 to 2024. This finding highlights a significant imbalance in e-waste research in Malaysia, based on an analysis of 62 selected articles. The study revealed that research on social aspects accounts for 72% of the total, while studies focusing on economic aspects represent only 3%. This oversight has resulted in ’regime resistance’ and has revealed weaknesses in the current policy framework. Furthermore, the findings indicate challenges in integrating informal actors and systems into the formal e-waste management framework for households, as evidenced by the alarmingly low reported recycling rate of just 1%. Finally, this paper suggests five key recommendations for achieving optimal e-waste management performance: (1) Linking local solutions with global strategies; (2) Developing a circular economy (CE) framework and extended producer responsibility (EPR) model; (3) Implementing basic design principles; (4) Enhancing governance and social awareness; and (5) Adopting a systems analysis approach.
Lightning surge interaction in distribution networks can produce severe fast-front transient overvoltages, insulation stress, back-flashover, and transformer terminal voltage escalation. This study evaluates the effectiveness of surge arrester placement in a 33 kV radial distribution network using PSCAD/EMTDC electromagnetic transient simulation. A total of 27 operating scenarios were analysed by varying three key parameters: lightning strike type, namely direct strike and lightning-induced electromagnetic coupling; insulation condition, namely normal operation and back-flashover operation; and surge arrester configuration, namely unprotected network, substation-based arrester placement at Site A, and line-corridor arrester placement at Site B. The simulation results show that the unprotected network is highly vulnerable, with direct lightning strikes producing voltage spikes up to 8.65 MV. Conventional arrester placement at the substation entrance effectively reduces the transformer terminal overvoltage to 464.792 kV under normal operation; however, during back-flashover, this configuration causes a ground potential rise (GPR) anomaly, increasing the transformer terminal voltage to 997.164 kV. In comparison, the proposed Site B placement provides better overall performance by eliminating the substation GPR effect, reducing the peak voltage to 719.910 kV, and achieving the fastest transient recovery with a settling time of $40.870 \mu \mathrm{s}$. The findings indicate that corridor-based surge arrester placement offers a more effective protection strategy than conventional substation-only placement by improving voltage clamping, reducing insulation stress, and enhancing the transient stability of the distribution network.
This study aims to examine whether demographic factor as control variables influence the relationship between green human resource management (GHRM), perceived organizational support (POS) and workplace deviance. The effects of age, gender, marital status, religion, and employment category on deviant behaviour were examined. A quantitative, cross-sectional survey design was employed, using a self-administered questionnaire distributed to human resource personnel in a utility company. A total of 74 responses were obtained through simple random sampling and analyzed using hierarchical multiple regression to assess the effects of GHRM, POS, and demographic factors on deviant behaviour. The findings reveal a significant negative relationship between POS and deviant behavior, indicating that stronger organizational support reduces employee misconduct. Conversely, GHRM demonstrated no significant relationship with deviance, suggesting its role is more closely tied to sustainability initiatives than to shaping employee behavior. Demographic control variables showed only weak associations with deviant behavior, emphasizing that workplace deviance is influenced more by organizational factors than by personal characteristics. The study is limited by its focus on a single organization and reliance on self-reported data. Nonetheless, it provides practical insights for utility companies and similar organizations, highlighting the importance of strengthening organizational support to foster ethical conduct and reduce workplace deviance while reinforcing sustainable human resource practices.
The increasing digitalisation of critical energy infrastructure has elevated cybersecurity from a traditional information technology concern to a broader software engineering and risk governance challenge. While previous studies have examined cyber threats, regulatory requirements, and operational resilience independently, limited attention has been given to integrating secure software engineering practices with cyber risk governance in the energy sector. This study addresses that gap through a PRISMA 2020-based systematic literature review. A total of 1,092 records were identified from Scopus, Web of Science, Google Scholar, and authoritative institutional sources, of which 70 studies met the final inclusion criteria. The review synthesises evidence on IT/OT convergence, ransomware, supply-chain vulnerabilities, artificial intelligence, and emerging cybersecurity regulations affecting critical energy systems. The findings indicate that effective cyber resilience requires security to be embedded throughout the software development lifecycle rather than treated solely as a compliance activity. Based on the reviewed literature, a four-pillar framework encompassing regulatory compliance, operational technology security, third-party risk management, and AI governance is proposed and aligned with SSDLC and DevSecOps principles. The framework promotes secure-by-design architectures, continuous security validation, and lifecycle-oriented risk management for critical infrastructure applications. This study contributes an integrated software engineering perspective that connects cyber risk governance with secure software development practices. The proposed framework offers practical guidance for software engineers, cybersecurity practitioners, and policymakers seeking to strengthen resilience, improve compliance readiness, and support the secure evolution of critical energy infrastructure.
Reliable communication is essential for the modernization and smart operation of medium voltage networks. However, selecting the optimal communication technology between Narrowband Power Line Communication (NBPLC) and fiber optic communication involves trade-offs in technical performance, service, and economic factors. This study presents a comparative evaluation of these two communication technologies using a Multi-Criteria Decision-Making approach based on the Analytic Hierarchy Process. The evaluation considers technical criteria (mobility, future expansion, and data rate), service standard criteria (installation and maintenance complexity), and economic criteria (capital and operational expenditures). The results indicate that fiber optic achieves a slightly higher overall priority score than NBPLC. While NBPLC offers advantages in installation complexity, maintenance complexity, and capital cost due to the use of existing infrastructure, fiber optic demonstrates superior scalability, bandwidth, and operational cost efficiency. Overall, fiber optic is identified as a more balanced and future-ready communication solution for enhancing reliability and supporting smart grid development in 11 kV distribution networks.