
This study presents a comprehensive assessment of natural and anthropogenic radioactivity in industrialized soils from two key zones in Bordj Bou Arreridj and M'sila, eastern Algeria. Utilizing high-resolution gamma-ray spectrometry with a high-purity germanium (HPGe) detector, the investigation determined the activity concentrations of 226Ra, 232Th, and 40K radionuclides. The obtained mean activity concentrations were 20.6 +/- 1.4, 27.3 +/- 0.7, and 464 +/- 9 Bq & centerdot;kg-1, respectively. Notably, 137Cs was detected only in the Bordj Bou Arreridj zone at trace levels, attributed to historical radioactive fallout. The air absorbed dose rates yielded a mean value of 45.6 +/- 1.4 nGy & centerdot;h-1, while the outdoor annual effective doses remained significantly below the International Commission on Radiological Protection (ICRP) limit of 1 mSv & centerdot;y-1. All calculated radiological indices were within safety limits, indicating no significant public health hazards. These results provide a critical radiological characterization of Algerian industrial soils, offering essential baseline data for environmental monitoring and the development of radiation protection standards in Algeria.
BackgroundScattered and random coincidences in brain PET imaging introduce significant noise and degrade resolution. Current correction algorithms for these effects are complex and computationally intensive. Fully connected neural network (FCNN) offers strong feature learning capabilities, versatility, and flexibility. Given that the coincidence data in brain PET imaging has relatively few features, FCNNs are well-suited to rapidly establish the relationship between coincidence data information and coincidence event types.MethodsEleven digital brain models were simulated using the Geant4 application for tomographic emission (GATE) [1]. Features extracted from the resulting data were used as inputs, with coincidence type as the target. FCNN was trained on this dataset. Quantitative evaluation was performed using contrast recovery coefficient (CRC), signal-to-noise ratio (SNR), and contrast-to-noise ratio (CNR) metrics.ResultsFCNN enables rapid filtering of coincidence data outside the brain region and efficiently corrects both random and scattered coincidences within the brain region. After valid coincidence discrimination, the valid coincidence rate remained at 95.60%, while the scatter fraction decreased from 40.60% to 29.01% and the random fraction dropped from 44.65% to 33.85%. Quantitative evaluation demonstrates that the random and scatter coincidence correction (RSC) method significantly enhances image quality when combined with attenuation-corrected (AC), improving the CRC from 0.946 to 0.969, SNR from 10.24 to 19.13, and CNR from 0.402 to 0.496. Conversely, under non-attenuation-corrected (NAC) conditions, RSC improves CRC (0.945 to 0.971) but reduces SNR (11.53 to 9.73) and CNR (0.569 to 0.521), indicating a trade-off between signal purity and statistical noise.ConclusionFCNN effectively reconstructs the true activity distribution of the radioactive source and enhances image contrast, demonstrating promise for clinical real-time brain PET imaging.
Monte Carlo calculations were performed to optimise the neutron flux from a spherical tungsten conversion target for a 30 MeV electron accelerator, assuming an average beam current of 120 mu A, which requires the conversion target to absorb approximately 4.2 kW of power. The results demonstrate that the backward direction is optimal for neutron production, yielding a neutron flux of 2.4286(3)& centerdot;108 n/cm2/s at a distance of 60 cm from the centre of the conversion target, measured at an angle of 145 degrees for a spherical conversion target with a diameter of 10 cm.
Accelerator-based neutron sources offer an attractive alternative to nuclear reactors for boron neutron capture therapy (BNCT) due to their unique advantages, including low cost, safety, and the feasibility of hospital installation. In this study, a series of simulations were performed based on a 3.5 MeV proton beam with a current of approximately 10 mA. This paper proposes an optimized beam shaping assembly (BSA) based on the Li37(p,n)Be47 {}_3<^>7{ m{Li}}({ m{p}},{ m{n}}){}_4<^>7{ m{Be}} neutron production reaction. The optimal target thickness was determined by considering both the neutron yield and the proton Bragg peak. The basic standards of the International Atomic Energy Agency (IAEA) were adopted as guidelines for the BSA design, and various neutron moderating materials as well as different gamma filter materials were evaluated. The performance of the designed neutron beam was further evaluated using a modified Snyder head phantom, taking into account the relevant parameters and dose profiles in irradiated tissues. In the simulations, boron concentrations of 30 ppm in tumor tissue and 10 ppm in healthy tissue were set. The results show that the same conclusion is reached regardless of whether the maximum tolerable dose to the skin (11 RBE-Gy) or that to normal tissue (12.5 RBE-Gy) is considered. A maximum dose can be delivered to the tumor site within 40 minutes of neutron irradiation, and the advantage depth is determined to be 9.2 cm.
Reliable thermodynamic data for cesium compounds are essential to predict fission products behavior during severe nuclear reactor accidents. This study establishes the physicochemical properties of cesium chromate (Cs2CrO4), cesium ferrate (Cs2FeO4), and its decomposition product CsFeO2 through combined experimental and first-principles approaches. High-purity samples were synthesized by solid-state reaction and characterized using powder X-ray diffraction (XRD), thermogravimetric-differential scanning calorimetry (TG-DSC), and in-situ high-temperature XRD measurements up to 1050 degrees C. First-principles DFT and quasi-harmonic phonon calculations provided complementary insights into vibrational and electronic properties. Cs2CrO4 crystallizes in an orthorhombic Pnma structure and undergoes one-step decomposition at temperatures of about 950 degrees C. Cs2FeO4 exhibited a rapid dehydration at about 97 degrees C, transformed to CsFeO2 starting from 170 degrees C, transiently reabsorbed oxygen at a temperature range of 400 degrees C to 800 degrees C, and finally decomposed to Fe2O3 above 1086 degrees C. The computed heat capacities reproduced the experimental Cp up to 750 K (476.85 degrees C), while the imaginary phonon modes reveal dynamic instabilities in ferrate phases. An electronic-structure analysis revealed band gaps of about 3.0 eV for Cs2CrO4 and about 1.2 eV for Cs2FeO4, while CsFeO2 displays metallic behavior. By linking these results to severe accident scenarios, this work clarifies how decomposition thresholds, phase stability ranges, and redox sensitivity of cesium compounds govern their volatility, transport, and deposition in reactor containment. The validated dataset provides critical input for source-term databases (e.g., ECUME - effective chemistry database of fission products under multiphase reaction) and severe accident codes such as MELCOR and ASTEC, thereby improving the predictive accuracy of cesium release and radiological safety assessments.