Metal wear and corrosion debris remain a limiting factor for long-term durability of total hip replacement (THR). Common wear particle production techniques for research differ from the actual tribocorrosion processes at the implant site, potentially causing loss of valuable information. The aim of this study was to investigate reactions to freshly generated and time-stabilized particles and ions released from CoCrMo-alloy using a bio-tribometer, which mimics conditions of the periprosthetic environment. THP-1 macrophages were challenged with freshly produced or time-stabilized wear debris. Wear generation took place in a custom-built bio-tribometer inside a CO2 incubator operating with a reciprocating rotation of an Al2O3 ball against a CoCrMo disc. Two different electrochemical conditions with increasingly forced corrosion rates were tested: +0.45 V (passive domain) and +0.67 V (transition to transpassive domain). Cell viability, proinflammatory cytokines, electrochemical measurements and ICP-MS metal ion content analyses were performed. Cobalt/ chromium concentrations were 6.6/ 1.6 ppm in the passive domain and almost doubled to 11.4/ 3.0 ppm in the passive-transpassive domain. Under those electrochemical conditions, freshly produced and time-stabilized CoCrMo wear decreased cell viability to the same extent. Secretion of proinflammatory cytokines were not significantly different for freshly produced and time-stabilized debris. This study suggests that freshly generated and time-stabilized metal particles/ions cause similar toxicity and inflammatory reactions in macrophages, indicating that standard practices for generating wear debris are valid methods to evaluate wear particle disease. Other cell types, materials, and corrosion potentials need to be studied in the future to solidify the conclusion.
Polyethylene wear has been a concern for the longevity of total knee replacements (TKR). A characteristic wear feature often observed on the articular surfaces of retrieved polyethylene tibial inserts is a striated pattern of hills and troughs. This pattern is of interest because its surface area has been found to correlate with increased tibial insert wear. We therefore addressed the following two research questions: (1) What is the prevalence of the striated pattern on a contemporary tibial insert design made from conventional ultra-high-molecular-weight polyethylene (UHMWPE)? (2) Are the peaks and troughs of the striated pattern connected with differences in crystallinity developed during the wear process? The prevalence and area coverage of the striated patterns were determined on a set of 81 retrieved tibial inserts of a cruciate-retaining TKR design. The striated areas were mapped using an optical coordinate measuring machine. Differences in crystallinity between troughs and hills were determined on a representative tibial insert using Raman spectroscopy. The striated pattern was observed on 61 out of 81 (75%) of the retrieved tibial inserts, covering an average of 32% of the total articular area. In the representative insert that was evaluated, the hills exhibited higher crystallinity (68%) than the troughs (54%) (p = 0.001). Conversely, the troughs exhibited higher amorphous phase content (22%) than the hills (19%) (p = 0.04). In conclusion, this pattern of hills and troughs is another example of microstructural changes in UHMWPE stemming from tribological stresses.
Biomechanical influences play a fundamental role in the structural, functional, and biosynthetic properties of articular cartilage. During physiologic joint loading, the contact area between two surfaces migrates due to the primary and secondary motions of the joint. It has been demonstrated that a migratory contact area plays a critical role in reducing the coefficient of friction at the cartilage surface. However, a detailed analysis of the influences that a migratory contact area plays on the structural, functional, and biosynthetic properties remain to be explored. In this study, bovine cartilage explants were placed in a biotribometer. Explants were subjected to compression and shear forces of migratory contact area, namely moving contact (MC) articulation, or stationary contact area, namely stationary contact (SC) articulation. Free swelling explants were used as control. In a separate study, bovine cartilage-bone grafts were used for frictional testing. On histologic analysis, the SC group had evidence of surface fibrillations, which was not evident in the MC group. Compared to the SC group, the MC group cartilage explants had increased chondrocyte viability, increased lubricin synthesis, and comparable proteoglycan synthesis and release. MC articulation had reduced coefficient of friction as compared to SC articulation. MC articulation led to reduced surface roughness as compared to SC articulation. In conclusion, a migratory contact area can play an important role in maintaining the structural, function, and biosynthetic properties of articular cartilage. This study provides further evidence of the importance of migratory contact area and in vitro assessment of natural joint movement, which can be further evaluated in the context of cartilage homeostasis and disease.
Biotribology is one of the key branches in the field of artificial joint development. Wear and corrosion are among fundamental processes which cause material loss in a joint biotribological system; the characteristics of wear and corrosion debris are central to determining the in vivo bioreactivity. Much effort has been made elucidating the debris-induced tissue responses. However, due to the complexity of the biological environment of the artificial joint, as well as a lack of effective imaging tools, there is still very little understanding of the size, composition, and concentration of the particles needed to trigger adverse local tissue reactions, including periprosthetic osteolysis. Fourier transform infrared spectroscopic imaging (FTIR-I) provides fast biochemical composition analysis in the direct context of underlying physiological conditions with micron-level spatial resolution, and minimal additional sample preparation in conjunction with the standard histopathological analysis workflow. In this study, we have demonstrated that FTIR-I can be utilized to accurately identify fine polyethylene debris accumulation in macrophages that is not achievable using conventional or polarized light microscope with histological staining. Further, a major tribocorrosion product, chromium phosphate, can be characterized within its histological milieu, while simultaneously identifying the involved immune cell such as macrophages and lymphocytes. In addition, we have shown the different spectral features of particle-laden macrophages through image clustering analysis. The presence of particle composition variance inside macrophages could shed light on debris evolution after detachment from the implant surface. The success of applying FTIR-I in the characterization of prosthetic debris within their biological context may very well open a new avenue of research in the orthopedics community.
Articular cartilage is a robust tissue that facilitates load distribution and wear-free articulation in diarthrodial joints. These biomechanical capabilities are fundamentally tied to tissue hydration, whereby high interstitial fluid pressures and fluid load support facilitate the maintenance of low tissue strains and frictions. Our recent ex vivo studies of cartilage sliding biomechanics using the convergent stationary contact area (cSCA) configuration, first introduced by Dowson and colleagues, unexpectedly demonstrated that sliding alone can promote recovery of interstitial pressure and lubrication lost to static compression through a mechanism termed 'tribological rehydration.' Although exclusively examined in bovine stifle cartilage to date, we hypothesized that tribological rehydration, i.e., the ability to recover/modulate tissue strains and lubrication through sliding, is a universal behavior of articular cartilage. This study aimed to establish if, and to what extent, sliding-induced tribological rehydration is conserved in articular cartilage across a number of preclinical animal species/models and diarthrodial joints. Using a comparative approach, we found that articular cartilage from equine, bovine, ovine, and caprine stifles, and porcine stifle, hip, and tarsal joints all exhibited remarkably consistent sliding speed-dependent compression/strain recovery and lubrication behaviors under matched contact stresses (0.25 MPa). All cartilage specimens tested supported robust, tribological rehydration during high-speed sliding (>30 mm/s), which as a result of competitive recovery of interstitial lubrication, promoted remarkable decreases in kinetic friction during continuous sliding. The conservation of tribological rehydration across mammalian quadruped articular cartilage suggests that sliding-induced recovery of interstitial hydration represents an important tissue adaptation and largely understudied contributor to the biomechanics of cartilage and joints.